13.07.2015 Views

V3 Symbols Sheet - Actionair

V3 Symbols Sheet - Actionair

V3 Symbols Sheet - Actionair

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>V3</strong> <strong>Symbols</strong>Smoke Fire Damper (Red & Grey squareswithin damper icon), fully open (Top rightdamper icon) and healthy (Green circularindicator)Motor open/Spring closed (Blue & Red Arrowsin top left corner) Smoke Fire Damper travellingand healthySmoke Fire Damper fully closed and healthySmoke Fire Damper fully closed, healthy but notat its ‘normal’ position (Warning Triangle)Smoke Fire Damper faulty(Feedback failure)Smoke Fire Damper missing. Position unknown.(Either loss of power or communications to theSFDI)Smoke Fire Damper fully closed and under thedictates of an environmental input (Greensquare)For further explanation or assistance please contact Technical SupportIssue 06 100722Page 1


<strong>V3</strong> <strong>Symbols</strong>Smoke Fire Damper fully closed and under thedictates of a Fire Alarm input (Red square)Smoke Fire Damper fully closed and under thedictates of a Fire Fighter Override input (Yellowsquare)Group Healthy (Green icon) and all dampers ingroup open (Bottom left damper icon)Group Faulty (One or more dampers in group isfaulty)Group Healthy and dampers in group under thedictates of an Environmental input (Greensquare)Group Healthy and dampers in group under thedictates of a Fire Alarm input (Red square)Group Healthy and dampers in group under thedictates of a Fire Fighter input (Yellow square)For further explanation or assistance please contact Technical SupportIssue 06 100722Page 2


<strong>V3</strong> <strong>Symbols</strong>3PSFDI-BMS Healthy (Green circle) and underthe control of a BMS signal (PC Icon). Normalposition unknown (Warning triangle)3PSFDI-BMS fully closed and under thedictates of a Fire Alarm input (Red square). PCIcon turned light grey as Fire Alarm has control.3PSFDI-LNS Under control of the Actionpacsystem and in balanced position (arrows ondamper icon)3PSFDI is missing (Yellow Circle) deviceattempting to failsafe (Arrow), actual damperposition unknown (question mark).VAVI Healthy (Green circle) and under localcontrol by others (PC Icon). Normal signalunknown (Warning triangle)VAVI open and under the dictates of a Firefighter override (Yellow square) PC Icon turnedlight grey as Fire fighter has controlSDI Healthy (Green circle) and fully open. SDIIcon is represented by straight red and bluearrows (Drive Open / Drive Closed).For further explanation or assistance please contact Technical SupportIssue 06 100722South Street, Whitstable, KentCT5 3DU England.Tel: 01227 276100Fax: 01227 264262Email: sales@actionair.co.ukWebsite: www.actionair.co.ukPage 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!