13.07.2015 Views

EEP201 Fundamentals of Power System Earthing - QUT

EEP201 Fundamentals of Power System Earthing - QUT

EEP201 Fundamentals of Power System Earthing - QUT

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• Cost benefit analysis for engineering decision making: econometric models forESI, maintenance, refurbishment and replacement.• Budgeting and cost control, budget preparation with spreadsheets, cash flows,monitoring expenditure and budget review, pr<strong>of</strong>it and loss and balance sheets.• Risk analysis including WACC calculations, stochastic simulation and sensitivity.Student Comments"Excellent course in terms <strong>of</strong> both material and presentation." <strong>Power</strong>link Queensland"I rate this as one <strong>of</strong> the best courses I have attended for content and presentation"Energex"The most enjoyable and informative course I have attended. Well done." <strong>Power</strong>linkQueensland"Enjoyable course. Suggest all engineers do it." Energex"The type <strong>of</strong> course I should have undertaken 2 years ago." Capricornia ElectricityEEP209 <strong>Power</strong> <strong>System</strong> Harmonics• Generation <strong>of</strong> harmonics: converters, arc furnaces, SVC, inverters, electroniccontrol.• <strong>System</strong> response characteristics: resonance conditions, effect <strong>of</strong> load, typicalsystem responses.• Effects <strong>of</strong> harmonics: motors, generators, power cables, capacitors, electronicequipment, metering, relaying, telephone interference.• Reactive power compensation and harmonic control: converter power factor,reactive power compensation, control <strong>of</strong> harmonic currents.• Measurement <strong>of</strong> harmonics.• Recommended practices including AS2279.Recommended Prior Study: EEP205EEP210 Abnormal <strong>System</strong> Voltages• Supply quality standards: review <strong>of</strong> criteria, statutory requirements, emergencyand short term limits.• 50 Hz voltage: cause <strong>of</strong> voltage deviations, voltages during faults, motor starting.• Negative phase sequence voltages: AS1359 requirements, voltage unbalancestudies, modelling, measurement.• Voltage Transients and flicker: AS2279 requirements, disturbing loads, remedialmeasures, transient disturbances and power system plant.• <strong>Power</strong> system transient analysis: ATP studies.Recommended Prior Study: EEP205EEP211 Basic <strong>Power</strong> <strong>System</strong> Protection• Protection system reliability and security.• Methods <strong>of</strong> grading protection relays.• Speed/sensitivity considerations. Comparison <strong>of</strong> "unit" and "non-unit" protection.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!