13.07.2015 Views

Split case pump brochure - Wastecorp Pumps

Split case pump brochure - Wastecorp Pumps

Split case pump brochure - Wastecorp Pumps

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TheLatestTechnologyforEnergySavingsandPumpProtection.TurboFlow ControlOptions<strong>Wastecorp</strong>’sTurboFlow split<strong>case</strong><strong>pump</strong>sareavailablewithawideselectionof<strong>pump</strong>controlsandmonitoringunitstohelpprotectyour<strong>pump</strong>andpromotesaneasierwaytomaintainyourequipment.MonitoringunitsprovidedependabledatatohelpdeterminetheidealrangeforeficiencyandreducedenergyconsumptionSoftware,powerconsumptiontoolsandavarietyofpanelsareavailableforfacilitiesofalsizes.Cala<strong>Wastecorp</strong>PumpExperttodaytolearnmore.RecordingPumpDataMadeEasySelecttherightpackageforyourneeds.•Shockpulsemeasurement•Speedortemperaturemeasurement•VibrationmeasurementEasy-to-readdisplaycommunicatesstatusinformation•RealTimeClock— time-of-Dayfunctionality•Datacapture,eventlogs,reminderwarningsWASTECORPTURBOFLOW SPLITCASE PUMPS |8


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesDouble Suction <strong>Split</strong> Case, Centrifugal <strong>Pumps</strong>Overview of Performance Range Using 50 Hz Motors²WSD Series <strong>Split</strong> Case <strong>Pumps</strong>Pump Performance Chart (Utilizing 50 Hz / 2900 RPM Motors)WSD SERIESMODELDischarge Suction FlangeMax. Impeller ODPump Size¹ Flange Conn. Conn. Max. Capacity Max. Head Size³ Max. Power Approx. Weight(mm) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)WSD-300 80 x 125 x 350 80 3 125 5 240 1,057 107 351 350 14 75 101 204 450WSD-400 100 x 150 x 320 100 4 150 6 450 1,981 148 486 320 13 200 268 223 492WSD-500 125 x 200 x 300 125 5 200 8 650 2,862 122 400 300 12 200 268 350 772WSD Series <strong>Split</strong> Case <strong>Pumps</strong> Pump Performance Chart (Utilizing 50 Hz / 1450 RPM Motors)WSD SERIESMODELDischarge Suction FlangeMax. Impeller ODPump Size¹ Flange Conn. Conn. Max. Capacity Max. HeadSize³ Max. Power Approx. Weight(mm) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)WSD-300 80 x 125 x 350 80 3 125 5 150 660 44 143 350 14 22 30 204 450WSD-400 100 x 150 x 400 100 4 150 6 242 1,063 63 207 400 16 45 60 241 531WSD-500 125 x 200 x 480 125 5 200 8 435 1,915 86 282 480 19 110 148 500 1,102WSD-600 150 x 200 x 570 150 6 200 8 730 3,214 121 397 570 22 250 335 740 1,631WSD-800 200 x 250 x 660 200 8 250 10 1,080 4,755 167 548 660 26 450 603 1,000 2,205WSD-1000 250 x 300 x 610 250 10 300 12 1,640 7,221 131 430 610 24 560 751 1,400 3,086WSD-1200 300 x 400 x 710 300 12 350 14 2,380 10,479 183 600 710 28 1,120 1,502 2,600 5,732WSD-1400 350 x 400 x 640 350 14 400 16 3,700 16,291 139 454 640 25 1,000 1,341 2,570 5,666WSD-1600 400 x 500 x 600 400 16 500 18 4,100 18,052 130 426 600 24 1,250 1,676 3,200 7,055WSD Series <strong>Split</strong> Case <strong>Pumps</strong>Pump Performance Chart (Utilizing 50 Hz / 980 RPM Motors)WSD SERIESMODELPump Size¹DischargeFlange Conn.Suction FlangeConn.Max. CapacityMax. HeadMax. Impeller ODSize³Max. PowerApprox. Weight(mm) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)WSD-2000 500 x 600 x 1050 500 20 600 24 5,440 23,952 173 568 1,050 41 2,000 2,682 6,300 13,889WSD-2400 600 x 700 x 860 600 24 700 28 6,910 30,424 102 335 860 34 1,600 2,146 5,300 11,684WSD-2800 700 x 800 x 830 700 28 800 32 9,850 43,368 93 305 830 33 2,000 2,682 6,700 14,771The following <strong>pump</strong> operates at 730 RPMWSD-3200 800 x 900 x 980 800 32 900 36 11,620 51,161 74 242 980 39 2,000 2,682 9,130 20,128NOTES:1. Please contact the factory for proper model selection for your application.2. This is a general overview of the performance for this series of Turbo-Flow <strong>pump</strong>s.3. Optional impeller sizes are available, including trimmed impeller sizes. Contact factory for additional information.4. <strong>Wastecorp</strong>. <strong>Pumps</strong> reserves the right to make revisions to its products, performance, dimensions and specifications,and related information, without notice.WASTECORP TURBO FLOW SPLIT CASE PUMPS | 12


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesHorizontal <strong>Split</strong> Case Centrifugal <strong>Pumps</strong>Dimensional ChartWSDH Series <strong>Split</strong> Case <strong>Pumps</strong>Dimensional Chart - Pump With Steel BaseWSDH TYPE MAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONSMAX.PUMPWEIGHTInlet DN 1 Outlet DN 2 b 1 b 2B1 B2 L4 H≤ L3(mm) (mm) (kg)WSDH-300 125 80 26 24 330 330 415 600 300 204WSDH-400 150 100 28 24 370 370 415 760 300 241WSDH-500 200 125 30 26 450 450 515 825 366 500WSDH-600 200 150 30 28 600 500 590 1050 399 740WSDH-800 250 200 32 30 650 550 655 1240 464 1000WSDH-1000 300 250 36 32 650 550 730 1275 515 1400WSDH-1200 400 300 48 40 750 650 935 1430 748 2600WSDH-1400 450 350 44 40 750 670 910 1550 710 2570For <strong>pump</strong>s larger than 350 mm outlet, see <strong>pump</strong> dimensions mounted directly on a concrete pad.WSDH Series <strong>Split</strong> Case Sewage <strong>Pumps</strong>Dimensional Chart - Pump With Steel BaseWSDH TYPE MAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONSMAX.PUMPWEIGHTInlet DN 1 Outlet DN 2 b 1 b 2B1 B2 L4 H≤ L3(inches) (inches) (lb)WSDH-300 5 3 1.02 0.94 12.99 12.99 16.34 23.62 11.81 450WSDH-400 6 4 1.10 0.94 14.57 14.57 16.34 29.92 11.81 531WSDH-500 8 5 1.18 1.02 17.72 17.72 20.28 32.48 14.41 1102WSDH-600 8 6 1.18 1.10 23.62 19.69 23.23 41.34 15.71 1631WSDH-800 10 8 1.26 1.18 25.59 21.65 25.79 48.82 18.27 2205WSDH-1000 12 10 1.42 1.26 25.59 21.65 28.74 50.20 20.28 3086WSDH-1200 16 12 1.89 1.57 29.53 25.59 36.81 56.30 29.45 5732WSDH-1400 18 14 1.73 1.57 29.53 26.38 35.83 61.02 27.95 5666For <strong>pump</strong>s larger than 16" outlet, see <strong>pump</strong> dimensions mounted directly on a concrete pad.13 | WASTECORP TURBO FLOW SPLIT CASE PUMPS


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesHorizontal <strong>Split</strong> Case, Centrifugal <strong>Pumps</strong>Concrete Foundation MountWSDH Horizontal <strong>Split</strong> Case DrawingWASTECORP TURBO FLOW SPLIT CASE PUMPS | 14


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesHorizontal <strong>Split</strong> Case, Centrifugal <strong>Pumps</strong>Dimensional DrawingWSD Series Horizontal <strong>Split</strong> Case <strong>Pumps</strong> Dimensional DrawingSuction FlangeDischarge FlangeRefer to the WSDH Seriesdimensional chart formore information.NOTES:1. Pump dimensions vary. Contact factory for your project specific dimensions.2. Installation dimensions vary depending on motor and impeller size. Contactfactory for actual dimensions.3. Pad dimensions, if any, vary. Contact factory for actual dimensions for your <strong>pump</strong>.15 | WASTECORP TURBO FLOW SPLIT CASE PUMPS


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesHorizontal <strong>Split</strong> Case, Centrifugal <strong>Pumps</strong>Concrete Foundation MountWSDH Se ries Horizo ntal <strong>Split</strong> Case <strong>Pumps</strong>Dimensional Chart - Horizontal <strong>Pumps</strong> With No BaseWSDH TYPEMETRICDIMENSIONSInletDN 1MAX. FLANGEDIMENSIONSMAX. PUMP DIMENSIONSOutletDN 2 S 1 S 2 B 1 B 2e f h1 h2 h3 h4 b1 b2 b3 b4No. ofHolesHoleSize d(Φ)MAX.PUMPWEIGHT(mm)(mm)WSDH-1600 500 400 42 38 800 750 758 980 900 557 425 500 400 400 250 250 4 42 3200WSDH-2000 600 500 56 52 1250 1050 1090 1360 1150 800 650 650 780 1050 700 500 4-8 42 6300WSDH-2400 700 600 54 48 1100 1200 1000 1275 1100 760 610 610 750 1050 600 500 4 55 5300WSDH-2800 800 700 58 54 1300 1250 1160 1440 1200 850 630 630 640 940 600 600 4 42 6700WSDH-3200 900 800 62 58 1400 1300 1270 1580 1380 920 770 770 740 1040 600 600 4 55 9130For <strong>pump</strong>s smaller than 400 mm Outlet, see Pump Dimensions with Base(kg)WSDH TYPEIMPERIALDIMENSIONSInletDN 1MAX. FLANGEDIMENSIONSMAX. PUMP DIMENSIONSOutletDN 2 S 1 S 2 B 1 B 2e f h1 h2 h3 h4 b1 b2 b3 b4(inches)(inches)No. ofHolesHoleSize d(Φ)MAX.PUMPWEIGHTWSDH-1600 20 16 1.7 1.5 31.5 29.5 29.8 38.6 35.4 21.9 16.7 19.7 15.7 15.7 9.8 9.8 4 1-21/32 7,055WSDH-2000 24 20 2.2 2.0 49.2 41.3 42.9 53.5 45.3 31.5 25.6 25.6 30.7 41.3 27.6 19.7 4-8 1-21/32 13,889WSDH-2400 28 24 2.1 1.9 43.3 47.2 39.4 50.2 43.3 29.9 24.0 24.0 29.5 41.3 23.6 19.7 4 2-5/32 11,684WSDH-2800 32 28 2.3 2.1 51.2 49.2 45.7 56.7 47.2 33.5 24.8 24.8 25.2 37.0 23.6 23.6 4 1-21/32 14,771WSDH-3200 36 32 2.4 2.3 55.1 51.2 50.0 62.2 54.3 36.2 30.3 30.3 29.1 40.9 23.6 23.6 4 2-5/32 20,128For <strong>pump</strong>s smaller than 16" Outlet, see Pump Dimensions with Base(lb)WASTECORP TURBO FLOW SPLIT CASE PUMPS | 16


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesVertical <strong>Split</strong> Case, Centrifugal <strong>Pumps</strong>Dimensional DrawingWSD Series Vertical <strong>Split</strong> Case <strong>Pumps</strong> Dimensional DrawingSuction FlangeDischarge FlangeRefer to the WSDV Seriesdimensional chart formore information.NOTES:1. Pump dimensions vary. Contact factory for your project specific dimensions.2. Installation dimensions vary depending on motor and impeller size. Contactfactory for actual dimensions.3. Pad dimensions, if any, vary. Contact factory for actual dimensions for your <strong>pump</strong>.17 | WASTECORP TURBO FLOW SPLIT CASE PUMPS


TECHNICAL INFORMATION<strong>Wastecorp</strong> Turbo Flow WSD SeriesVertical <strong>Split</strong> Case, Centrifugal <strong>Pumps</strong>Dimensional ChartWSDV Series <strong>Split</strong> Case <strong>Pumps</strong>Dimensional Chart - Vertical Pump With Steel BaseWSDV TYPEMETRICDIMENSIONSInletDN 1MAX. FLANGEDIMENSIONS MAX. PUMP DIMENSIONS MAX.OutletDN 2 S 1 S 2 B 1 B 2h2 h3 h4 h5 zPUMPWEIGHT(mm) (mm) (kg)WSDV-300 125 80 26 24 330 330 140 225 320 735 450 204WSDV-400 150 100 28 24 370 370 170 260 300 715 520 241WSDV-500 200 125 30 26 450 450 200 305 355 870 610 500WSDV-600 200 150 30 28 600 500 300 370 400 990 740 740WSDV-800 250 200 32 30 650 550 350 430 440 1095 860 1000WSDV-1000 300 250 36 32 650 550 350 415 500 1230 830 1400WSDV-1200 400 300 44 36 700 650 350 430 570 1380 860 2097WSDV-1400 400 350 44 40 750 650 400 465 570 1380 930 1800WSDV TYPEIMPERIALDIMENSIONSInletDN 1MAX. FLANGEDIMENSIONSOutletMAX. PUMP DIMENSIONS MAX.PUMPDN 2 S 1 S 2 B 1 B 2h2 h3 h4 h5 z WEIGHT(inches) (inches) (lb)WSDV-300 5 3 1.02 0.94 12.99 12.99 5.51 8.86 12.60 28.94 17.72 450WSDV-400 6 4 1.10 0.94 14.57 14.57 6.69 10.24 11.81 28.15 20.47 531WSDV-500 8 5 1.18 1.02 17.72 17.72 7.87 12.01 13.98 34.25 24.02 1102WSDV-600 8 6 1.18 1.10 23.62 19.69 11.81 14.57 15.75 38.98 29.13 1631WSDV-800 10 8 1.26 1.18 25.59 21.65 13.78 16.93 17.32 43.11 33.86 2205WSDV-1000 12 10 1.42 1.26 25.59 21.65 13.78 16.34 19.69 48.43 32.68 3086WSDV-1200 16 12 1.73 1.42 27.56 25.59 13.78 16.93 22.44 54.33 33.86 4623WSDV-1400 16 14 1.73 1.57 29.53 25.59 15.75 18.31 22.44 54.33 36.61 3968WASTECORP TURBO FLOW SPLIT CASE PUMPS | 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!