13.07.2015 Views

HDL Ultra Cholesterol Calibrator - Sekisui Diagnostics

HDL Ultra Cholesterol Calibrator - Sekisui Diagnostics

HDL Ultra Cholesterol Calibrator - Sekisui Diagnostics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong><strong>Calibrator</strong>INTENDED USEFor the calibration of the <strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> assay.SUMMARYRefer to the <strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> Reagent package insert.REAGENTSThe <strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> <strong>Calibrator</strong> is a preparation oflyophilized human serum containing lipoproteins from thevarious lipoprotein classes including high-density lipoproteins.Note: The value of the <strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> <strong>Calibrator</strong> wasassigned by procedures traceable to the CDC <strong>HDL</strong> cholesterolreference method. 1, 2Precautions and Warnings1. For In Vitro Diagnostic Use.2. Do not pipette by mouth.3. Do not use the calibrator after the expiration date printed on thebox.4. Warning: Human source material. Treat as potentiallyinfectious. Each plasma donor unit used in the preparationof this product has been tested by an FDA-approved methodand found nonreactive for HBsAg, HCV, HIV 1 & 2 andHIV-1 Antigen. Because no known test method can offercomplete assurance that hepatitis B virus, HumanImmunodeficiency Virus (HIV) or other infectious agentsare absent, all human-based products should be handledin accordance with good laboratory practices usingappropriate precautions.5. Caution: Contains sodium azide, which may react withlead and copper plumbing to form potentially explosive metalazides. On disposal, flush drain with a large volume ofwater to prevent buildup.6. <strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> Reagent must be used with <strong>HDL</strong><strong>Ultra</strong> <strong>Cholesterol</strong> <strong>Calibrator</strong>.PreparationAllow the vial of calibrator to equilibrate to room temperaturebefore reconstitution. Lyophilized serum calibrator should bereconstituted by adding 1.0 mL of distilled or deionized water.Close the vial and let stand for 20 minutes. Dissolve the contentsof the vial by swirling gently to avoid the formation of foam.DO NOT SHAKEStorage and StabilityUnopened calibrator is stable at 2-8°C until the expiration dateprinted on the vial.After reconstitution, calibrator is stable for 14 days at 2-8°C.Reconstitution stability of the calibrator may be extended byaliquotting and freezing the reconstituted calibrator preparationat less than -70°C for up to 4 weeks.PROCEDUREMaterials ProvidedDescription Configuration Catalog Number<strong>HDL</strong> <strong>Ultra</strong><strong>Cholesterol</strong><strong>Calibrator</strong>3 x 1 mL 6272-3Materials Required but not ProvidedDescription Configuration Catalog Number<strong>HDL</strong> <strong>Ultra</strong><strong>Cholesterol</strong>ReagentR1 1 x 60 mLR2 1 x 20 mL6121<strong>HDL</strong> <strong>Ultra</strong><strong>Cholesterol</strong>Reagent<strong>HDL</strong> <strong>Ultra</strong><strong>Cholesterol</strong>Reagent R1<strong>HDL</strong> <strong>Ultra</strong><strong>Cholesterol</strong>Reagent R2R1 1 x 250 mLR2 1 x 80 mLR1 1 x 750 mLR2 1 x 250 mL61226123R16123R21. Class A volumetric pipettes.2. Distilled, deionized, Type II water or equivalent.CalibrationThe calibrator should be used to analyze patient samples inaccordance with the instructions outlined in Genzyme’s <strong>HDL</strong><strong>Ultra</strong> <strong>Cholesterol</strong> Reagent package insert. The value of the<strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> <strong>Calibrator</strong>, which can be found on thecalibrator vial label, is assigned by procedures traceable to theCDC <strong>HDL</strong> cholesterol reference method. 1,2 Refer to theinstrument manufacturer’s recommendation for calibrationfrequency. If assistance is required please call GenzymeTechnical Marketing at 800-332-1042. Quality Control valuesshould be within the expected range.REFERENCES1. National Reference System for <strong>Cholesterol</strong>. CRMLN <strong>HDL</strong><strong>Cholesterol</strong> Protocol, November 2002.2. Kimberly MM, Leary ET, Cole TG, Waymack PW.Selection, validation, standardization, and performance ofa designated comparison method for <strong>HDL</strong>cholesterol foruse in the <strong>Cholesterol</strong> Reference Method LaboratoryNetwork. Clinical Chemistry 1999; 45: 1803-12.Refer to the <strong>HDL</strong> <strong>Ultra</strong> <strong>Cholesterol</strong> Reagent package insert foradditional references.Indications of DeteriorationPresence of turbidity.1


Definitions for SymbolsREF Catalog numberFor in vitro diagnostic useTemperature limitationManufactured byUse by Batch codeConsult instructions for use Caution, consult accompanying documentManufactured by:The Americas31 New York AvenueFramingham, MA 01701-9322USAPhone: 800-999-6578Fax: 610-594-8585Email: usdiagcustomerservice@genzyme.comwww.genzymediagnostics.com80-7291-00-00 6/092

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!