13.07.2015 Views

KLEENGUARD* Safety Products Catalog - KIMBERLY-CLARK ...

KLEENGUARD* Safety Products Catalog - KIMBERLY-CLARK ...

KLEENGUARD* Safety Products Catalog - KIMBERLY-CLARK ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Liquid & Gas Chemical Kimberly-Clark Resistance Professional* Test / <strong>KLEENGUARD*</strong> www.kc-safety.comA80 Apparel FabricChemicals Liquid Penetration Liquid PermeationASTM F1001 asTM F903 asTM F739Test Duration: 60 mins. NormalizedSaturation Exposure Breakthrough (min.) Rate (µg/cm 2 /min)Acetone Pass 22 HighAcetonitrile Pass 35 0.8Ammonia not applicable >480 nDCarbon Disulfide Pass Immediate HighChlorine not applicable >480 nDDichloromethane Pass Immediate HighDiethylamine Pass 20 Highn,n-Dimethylformamide Pass 109 0.45Ethyl Acetate Pass 18 0.8n-Hexane Pass >480 Not detectedMethanol Pass >480 Not detectedNitrobenzene Pass 77 3.8Sodium Hydroxide (50%) Pass >480 Not detectedSulfuric Acid (98%) Pass >480 Not detectedTetrachloroethylene Pass 50 8.2Tetrahydrofuran Pass Immediate HighToluene Pass 6 HighAdditional chemical test data is available at www.kc-safety.com/chemicalbarrierdata?Did you know?When selecting chemicalprotective clothing, it’simportant to be sure thatthe garment offersadequate resistance tothe chemicals beinghandled in yourworkplace.AccessoriesApronSleeve Protector - Elastic top, taped seamsStock Code Size Case Count Stock Code Case Count45748 29”x 44” 5045749 100Properties of Kleenguard* A80 Apparel FabricPhysical Properties Test Method resultsTensile Strength (MD) ASTM D5034 52.8 lbs(CD)40 lbsTrapezoidal Tear (MD) inda ist 100.2 19.6 lbs(CD)9.5 lbsMullen Burst iso 13938-1 54.3 psiHydrohead AATCC 127-1998 625 cmFlammability CPSC 1610 Class 1Blood Penetration ASTM F1670 PassBloodborne Pathogens ASTM F1671‡ Pass‡ Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetrationby Bloodborne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System.Kleenguard* A80 Taped SeamsChemicalsASTM F1001AcetoneAcetonitrileCarbon DisulfideDichloromethaneDiethylaminen,n-DimethylformamideEthyl Acetaten-HexaneMethanolNitrobenzeneSodium Hydroxide (50%)Sulfuric Acid (98%)TetrachloroethyleneTetrahydrofuranToluenePenetrationasTM F903Test Duration: 60 mins.Saturation ExposurePassPassPassPassPassPassPassPassPassPassPassPassPassPassPasswarning: Fabric passes penetration testing; however,the chemical is a known or suspected carcinogen or skinabsorbed toxin.39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!