13.07.2015 Views

Modbus Register Map 2011-04-18 Rev3 - APRS World, LLC

Modbus Register Map 2011-04-18 Rev3 - APRS World, LLC

Modbus Register Map 2011-04-18 Rev3 - APRS World, LLC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

evised <strong>2011</strong>-<strong>04</strong>-<strong>18</strong> by JJJXRW2G <strong>Modbus</strong> <strong>Register</strong> <strong>Map</strong>Notes:Addresses are actual addresses as sent "over the wire". For PDU address, add 1.All registers on this page are read only. Some status register reads trigger events.Counter ChannelsValue RangeNotesAddress Channel Description Low High0pulse count 0 65535 rolls over1 pulse time 0 655352 pulse min time 0 6553503 standard deviation ? ? not implemented4 pulse sum, low wordmust read low word first0 42949672965 pulse sum, high word6pulse count 0 65535 rolls over7 pulse time 0 655358 pulse min time 0 6553519 standard deviation ? ? not implementedmust read low word first0 429496729612pulse count 0 65535 rolls over13 pulse time 0 6553514 pulse min time 0 65535215 standard deviation ? ? not implementedmust read low word first0 42949672961016pulse sum, low wordpulse sum, low word1117pulse sum, high wordpulse sum, high wordAnalog ChannelsValue RangeAddress Channel Description Low HighNotes<strong>18</strong>current value 0 409519 0 averaged value 0 409520 standard deviation ? ? not implemented21current value 0 409522 1 averaged value 0 409523 standard deviation ? ? not implemented24current value 0 409525 2 averaged value 0 409526 standard deviation ? ? not implemented27current value 0 409528 3 averaged value 0 409529 standard deviation ? ? not implemented30current value 0 409531 4 averaged value 0 409532 standard deviation ? ? not implemented33current value 0 409534 5 averaged value 0 409535 standard deviation ? ? not implemented36current value 0 409537 6 averaged value 0 409538 standard deviation ? ? not implemented39current value 0 409540 7 averaged value 0 409541 standard deviation ? ? not implementedStatus and Sample ControlValue RangeAddress Description Low HighNotes42 sequence number (increments when read) 0 65535 rolls over43 ticks, 10 millisecond since last measurement 0 65535 stops counting at 6553544 uptime minutes 0 65535 stops counting at 6553545 read to trigger new measurement 0 <strong>04</strong>6 read to trigger reset of pulse sum 0 <strong>04</strong>7 <strong>Modbus</strong> packets for us0 6553548 <strong>Modbus</strong> packets for others0 6553549 <strong>Modbus</strong> last error0 3 0=NO ERROR1=ILLEGAL FUNCTION2=ILLEGAL DATA ADDRESS3=ILLEGAL DATA VALUEALL OTHERS UNDEFINED50 read to clear <strong>Modbus</strong> counters and last error0 051 XBEE_SLEEP State of line if in I/O mode 0 1 Only defined when USE FOR I/O52 XBEE_RTS is select. 0=input or output53 XBEE_CTS Can be read from or written to low, 1=input or output high


evised <strong>2011</strong>-<strong>04</strong>-<strong>18</strong> by JJJXRW2G <strong>Modbus</strong> <strong>Register</strong> <strong>Map</strong>Notes:Addresses are actual addresses as sent "over the wire". For PDU address, add 1.Read Configuration Value RangeRead / Write LegendNotesWrite Address Channel Description Low High R ReadableR/(FW) 1000 Serial number prefix 'A' 'Z' Must Write EEPROM to save W WriteR/(FW) 1001 Serial number 0 65535 (FW)R 1002 Hardware Model R/WR 1003 Hardware Version R/(FW)R 10<strong>04</strong> Software ModelR 1005 Software VersionR/W 1006 <strong>Modbus</strong> Address0 127 Default is 24R/W 1007 <strong>Modbus</strong> Speed0 1 0=9600, 1=19200 Immediate change. Only applied in<strong>Modbus</strong> mode.R/W 1008 <strong>Modbus</strong> Mode0 1 0=RTU, 1=TCP-RTUR/W 1009 Transmit <strong>World</strong>Data every n seconds1 65535 Will transmit <strong>World</strong>Data only if JP3 jumpered duringboot.R/W 1010 Serial number prefix to trigger transmit 'A' Z' Set to 0 to disableR/W 1011 Serial number to trigger transmit 0 65535R/W 1012 Discrete I/O on status lines 0 1 0=STATUS LINES NORMAL, 1=USE FOR I/OR/W 1013 XBEE_SLEEP Status line input or output select 0 1 0=OUTPUT, 1=INPUT (when USE FOR I/O selected)R/W 1014 XBEE_RTS Status line input or output select 0 1R/W 1015 XBEE_CTS Status line input or output select 0 1R/W 1100 AN0 Averaging mode 0=Normal averagingR/W 1101 AN1 Averaging mode 1=Vector averageR/W 1102 AN2 Averaging modeR/W 1103 AN3 Averaging modeR/W 11<strong>04</strong> AN4 Averaging modeR/W 1105 AN5 Averaging modeR/W 1106 AN6 Averaging modeR/W 1107 AN7 Averaging modeR/W 1108 Sample analog every n*10 milliseconds 1 65535 Filtered in 16 element per channel FIRW 1999 Write EEPROM 1 1 1 causes settings writeW 19999 Passcode for factory programming Write onlyFactory WriteableRead and writeableRead and factory writeable

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!