Sieger Digi-Cat<strong>Combustible</strong> <strong>Gas</strong> <strong>Transmitter</strong>


Sieger Digi-Cat<strong>Combustible</strong> <strong>Gas</strong> <strong>Transmitter</strong>Features• Non-intrusive one person calibration– reducing downtime and maintenancecosts.• Linear 4 – 20mA output signal – industrystandard compatible with dedicatedcontrol equipment or plant controlsystems.• LED display – local indication of gasconcentration.• CENELEC and other certification– suitable for hazardous area installation.• Remote sensor mounting – ease ofcalibration for inaccessible areas.Applications• Petrochemical.• Pharmaceutical.• Chemical.• Manufacturing.• Aerosol Filling..The Digi-Cat is designed to interface witha catalytic sensor and has a conventional4 – 20mA output. The output may be selectedby means of a link to be floating, currentsource or current sink. The input to the unitis a resistive bridge input.


General specificationGeneral Specification*Input SignalRangesOutput SignalInhibit OutputRepeatabilityZero DriftSpan DriftResponse TimeOperating TemperatureStorage TemperatureOperating VoltagePower ConsumptionLoop ResistanceDisplayEnclosure MaterialEnclosure EntriesMounting EntriesWeightIngress ProtectionBridge signal from catalytic sensor0 – 100% LEL4 – 20mA floating, current source or current sink2mA±0.1% fsd< ±0.2% fsd< ±0.2% fsd< 0.5 seconds-20 to +40°C (higher temperature version available+55°C depending on certification)-60 to +80°C18 to 32V dc2W800 ohms3 digit LEDAluminium1 off sensor entry, 1 off 3⁄4" NPT cable entryWith mounting strap see dimensions below1.7kgNEMA 4X equivalent to IP66CE Standards BS EN 50081-1:1992BS EN 50082-1:1992Certification* General specification is for Digi-Cat transmitter only, no sensor attachedEExd IIC T5 (Tamb -20°C to +40°C)Higher temperature option available EExd IIB T5(Tamb -20°C to +55°C)


As World leaders in gas detection solutions, Honeywell Analytics’Sieger systems provide the most efficient, practical andcost-effective fixed-point equipment. Wherever protection isrequired from flammable or toxic gases, you can rely on ourequipment to provide practical solutions and to help keepyour business running safely and profitably.The Sieger range of fixed gas detectionSearchpointApex Searchline Excel Optima Plus Signalpoint System 57Typically used in the oil andgas distribution, petroleumextraction and chemicalmanufacturing industries,the Apex gas detector andtransmitter functions acrossa wide range of detectableflammable and toxic gases.With its rugged 316 stainlesssteel enclosure, it is especiallysuited for extreme conditions,and provides a cost-effectivegas detection solution for awide range of applications.Searchline Excel Cross Duct TMis an open path infrared gasdetector for the detection ofHydrocarbons within HVAC airintakes and ventilation ductingsystems up to 5 metersin width.It is based on the provenSearchline Excel, whichcovers ranges up to 200m.ClearShield TM glass coating,infrared beam and heatedoptical surfaces all combineto reduce downtime andincrease system availability.Designed for use in potentiallyexplosive atmospheresin harsh environmentalconditions, SearchPointOptima Plus is ideal wherespeed of response, reducedmaintenance and failsafeoperation is essential.Common applications includeoffshore platforms, productionstorage and offloadingvessels, and oil and gasterminals.Signalpoint is a self-containedgas sensor system for eithercombustible or toxic gases,designed to make installationsimple and maintenanceminimal. Constructedin strong plastic, it isparticularly suited for indoorapplications in light industrialenvironments.The System 57 controllerprovides display and alarmfacilities for the full range ofgas detectors. It comprisesa rack unit with mountingoptions for channel controlcards and interface cards.Find out morewww.honeywellanalytics.comCustomer business centreEurope and the rest of the worldHoneywell Analytics AGWilstrasse 11-U11CH-8610 UsterSwitzerlandTel: +41 (0)44 943 4300Fax: +41 (0)44 943 4398sales@zelana.co.ukSearchflame 16Searchflame 16 is a rangeof optical flame detectors fordetection of Hydrocarbon andnon-Hydrocarbon flamingfires in designated hazardousareas. Operating on UV orUV/IR principles, they havea 120-degree field of view,providing the widest coverageavailable by any product.705 HT SensorThe 705 High TemperatureSensor is a hazardousarea certified sensor forthe detection ofcombustible gases.Customer business centerAmericasHoneywell Analytics Distribution, Inc.400 Sawgrass Corporate PkwySuite 100Sunrise, FL 33325USATel: +1 954 514 2700Toll free: +1 800 538 0363Fax: +1 954 514 2784sales@zelana.comwww.honeywell.comPlease Note:While every effort has been made to ensureaccuracy in this publication, no responsibilitycan be accepted for errors or omissions.Data may change, as well as legislation, and youare strongly advised to obtain copies of the mostrecently issued regulations, standards, and guidelines.This publication is not intended to form thebasis of a contract.© 2005 Honeywell AnalyticsH_Sieger Digi-Cat_DS0172_V112/05© 2005 Honeywell Analytics11130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!