Jesper Staal, Technical Concept Manager, DONG ... - Essent
Jesper Staal, Technical Concept Manager, DONG ... - Essent
Jesper Staal, Technical Concept Manager, DONG ... - Essent
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Experience from Avedøre plant AVV2 1/5Plant data• Tangential fired tower boiler 800 MW thermal• Design parameters 300 bar/580°C• 16 burners in 4 levels• Wood pellets/gas/oil – steam temperature 540°C• Loesche coal mills for wood pellets milling• HD SCR, Elektro precipitator and wet DeSOx• 2001: Commissioning• 2005: Coal ash dosing in burner level 3• 2006: Steam temp. increased from 540 to 560°C10