TECHNICAL DATA<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong>100% SOLIDS <strong>BLOCK</strong> <strong>FILLER</strong> OR PATCHING COMPOUNDDESCRIPTION :USES :TYPICAL COVERAGE :<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong> is a 100% solids, 2-componentepoxy formulated for sealing and filling CMU walls or verticalpoured in place concrete with “bug-holes”; leaving an evensurface to apply a coating. <strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong> canalso be used as a patching material on irregular vertical andhorizontal surfaces by adding a thickener such as fumed silica.<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong> is VOC compliant and meets allUSDA guidelines for use in federally inspected facilities.<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong> is recommended for fillingirregularities in CMU and horizontal or vertical concretesurfaces, under most ROCK-TRED floor or wall systems.<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong> is typically applied at a minimumspread rate of 160 sq. ft. / gal. (3.68 m 2 /L) 10 mils DFT orthicker depending on substrate & project requirements.ADVANTAGES : 100% solids Odorless / solvent-free Excellent adhesion VOC Compliant High impact resistance Excellent fillerTYPICAL PROPERTIES :APPLICATION PROPERTIESVolume mix ratio2 to 1 (Resin to Hardener)Viscosity (mixed)6000-10000 CPS TypicalTensile Elongation2 % (ASTM D-638)Solids Content [%]100 % (ASTM D-2697)Hardness (ASTM D-2240) 70-80 (Shore D)VOC 0 g/l (EPA method 24)Application Temps. 50 0 – 85 0 F (10 0 – 29 0 C)Working time 32 minutes @ 75 0 F (24 0 C)Recoat time 6-8 hours @ 75 0 F (24 0 C)‘Open’ for light service 12-14 hours @ 75 0 F (24 0 C)‘Open’ for normal operation 24+ hours @ 75 0 F (24 0 C)For physical properties on this product, refer to ROCK-TRED’s Data ChartPACKAGING : 3 Gallon Units (11.4 L)ROCK‐TRED 405 N Oakwood Ave, Waukegan, IL 60085 / 888 . ROCK‐TRED rev. 4‐2011 Page 1


<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong>LIMITATIONS & FOR BEST RESULTS : Do not thin this product. Do not apply when Humidity exceeds 70%indoors. Do not allow to puddle during application. Allow each coat to dry to ‘tack-free’ or clearprior to re-coat. When re-coating, always apply the next coatwithin 24 hours of completing the previouscoat. Do not apply this product heavier / thicker thanthe recommended spread rate / mil thickness.PRODUCT APPLICATION :Apply using brush, roller and squeegee. ROCK-TRED product test data is based on environmentaltemperatures of 75 0 F (24 0 C). Viscosity andworking time are always affected by temperaturesabove or below that mark. When applying product– always consider the ambient, surface, andproduct temperature at the time and place ofinstallation.COLOR AND TEXTURES :<strong>CHEM</strong>-<strong>WALL</strong> <strong>BLOCK</strong> <strong>FILLER</strong> is available in offwhitefrom the factory. It can be tinted using RTEColorants to ‘move’ the base coat color to a desiredcolor. Most ROCK-TRED products are available ina wide range of textures using an appropriateaggregate.<strong>CHEM</strong>ICAL RESISTANCE :Always refer to ROCK-TRED’s chemical resistantchart for specific information on each product /system or contact ROCK-TRED directly.PRODUCT STORAGE :DO NOT allow ROCK-TRED products to freeze. AllROCK-TRED products should be properly storedabove the floor on pallets or shelves, and in anarea that has a constant minimum temperature of50 0 F (10 0 C).SURFACE PREPARTION : Always apply ROCK-TRED products to a ‘clean / sound’ substrate that isfree of laitance, grease, oils, debris, and curingcompounds. Concrete substrates should be curedfor a minimum of 28 days prior to application ofproduct [except as otherwise noted on theindividual Product Data Sheet]. Wheneverpossible, remove existing coatings completely; ifcomplete removal is unavoidable always performtests to determine adhesion and compatibility to theexisting substrate. If the substrate is not properlyprepared and the appropriate profile is notachieved, failure of the product to adhere to thesubstrate may occur.CLEAN UP :Application tools and equipment can be cleanedwith soap and water immediately after use, or withsolvent once the product has begun to cure.DISPOSAL :Product containers will contain product residue andmust be disposed of properly. Label warningsmust be observed at all times. All containers mustbe disposed in accordance with federal, state, andlocal regulations.IMPORTANT NOTICE :Always read and acquaint yourself with ROCK-TRED’S Product Data Sheet, MSDS [materialsafety data sheet], and product labels for eachindividual product prior to mixing and prior to use.For further assistance, product questions,additional information and/or unexpected orunusual installation conditions – contact your localrepresentative or ROCK-TRED directly forrecommendations.WARRANTY :Information about ROCK-TRED products is given, to the best of our knowledge, based on tests and experience. Such information supplied about our productsis not a representation or a warranty. It is supplied on the condition that you make your own tests to determine suitability of the product for the particularpurpose. As products are often applied or used under conditions beyond our control, ROCK-TRED cannot guarantee anything except the quality of itsproducts. ROCK-TRED warrants that the products meet the specifications set forth by ROCK-TRED, but we reserve the right to change any givenspecification prior to notice. ROCK-TRED DISCLAIMS ALL WARRANTIES RELATING TO THE PRODUCTS AND THEIR APPLICATION, EXPRESS ORIMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.Receipt of a ROCK-TRED product constitutes acceptance of the terms of this limited warranty and the terms and conditions set out in our invoice, contraryprovisions of buyer’s purchase documents notwithstanding. Upon receipt of the merchandise, purchaser has 30 days to notify ROCK-TRED, in writing, thatmaterials are defective. In the event ROCK-TRED finds that the product delivered is off specification, ROCK-TRED will, at its sole discretion, either replace theproduct(s) or refund the purchase price thereof, and ROCK-TRED’s choice of one of these remedies is the buyer’s sole remedy. In no event shall the liability ofROCK-TRED exceed the purchase price of shipped merchandise. Claims must be in writing. Claims after 30 days are void. ROCK-TRED will, under nocircumstances, be liable for special, incidental, or consequential damages. This warranty supersedes all other guaranties, whether oral or written, and whetherexpressed, implied, or statutory. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with anysale of our products. Certain products may contain chemicals that may cause serious physical injury. Before using, please read the Material Safety DataSheet and follow all precautions to prevent bodily harm.ROCK‐TRED 405 N Oakwood Ave, Waukegan, IL 60085 / 888 . ROCK‐TRED rev. 4‐2011 Page 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!