13.07.2015 Views

Sunrise C18 Sunrise C18-SAC

Sunrise C18 Sunrise C18-SAC

Sunrise C18 Sunrise C18-SAC

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Sunrise</strong> <strong>C18</strong> and <strong>C18</strong>-<strong>SAC</strong>Silanol Activity Controlled <strong>C18</strong> HPLC Column◆ New generation reversed-phase utilized silanol groups■ Silanol group and peak tailingIt is generally said that residual silanol groups ona stationary phase such as <strong>C18</strong> (ODS) causesabsorption or peak tailing for a sample.Especially silanol groups near a hydrophobicsite don’t solvate with water completely, so thatthey show high absorption for basic compounds.Its peak shows terribly tailing. Several endcappingtechniques have been developed tosolve these problems for many years.■ Silanol activity control technology1st generation2nd generationPellicular type3rd generationBonded type4th generationHighly endcappedtypeHigh carbon andend-capped type5th generationHybrid typeSilanol ActivityControlTechnology(Post-X2)<strong>Sunrise</strong> <strong>C18</strong><strong>Sunrise</strong><strong>C18</strong>-<strong>SAC</strong>ChromaNik developed the technique thatdecreased only silanol groups with highabsorption activity to a basic compound andremained effective sailnol groups on thestationary phase. Silanol activity control and noend-capping led the existence of silanol groupswith high hydration which created a new andunique reversed-phase separation modeincluding hydrogen bond and ion-exchangeinteraction. Furthermore, silanol activitycontrolling, then end-capping techniqueimproved a peak shape of a basic compoundexceedingly.OSiOSiOSilanol groupswith highabsorption activitySiHOSiHOSiHSilanol ActivityControlTechnologyOSiSiOSiChangeover tosiloxane bondOSiOSiHSilanol activity control◆ Feature of <strong>Sunrise</strong> series<strong>Sunrise</strong> <strong>C18</strong>•The“1st Choice” column as a fully end-capped <strong>C18</strong> column•Full end-cappingafter silanol activity control•Reducingadsorption of a basic compound extremelyely•A good peak shape for a metal cheleting compoundound•Widely available for general reversed-phaseseparation<strong>Sunrise</strong> <strong>C18</strong>-<strong>SAC</strong>•The "2nd Choice" column which takes advantage ofeffective silanol groups interaction•Reducingsilanol groups with high adsorption activityity•The new separation mechanism including hydrogen bondand ion-exchange interaction•Effective for separation of a basic compound and a polarcompound•Different selectivity and improvement of separation withoutchanging a mobile phase■ The elution order of pyridineA) <strong>Sunrise</strong> <strong>C18</strong>(end-capped)1C) <strong>Sunrise</strong> <strong>C18</strong>-<strong>SAC</strong>(non end-capped)31(2)B) Conventional no end1Column size: 4.6 X 150mm3 Mobile phase:30/70= CH3OH/H2OSample: 1 = uracil(2) = pyridine3 = phenolend-capped<strong>C18</strong>3(2)(2)0 5 10 15 20retention time / min

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!