INDUSTRIAL FLUID POWER COMPONENTSAND SYSTEMSHV SERIESManual/ Proportional Directional ValvesHV39HV9<strong>HV18</strong>EPHV39Lever Actuatedwith OptionalProportionalControl31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com


<strong>HV18</strong> <strong>Series</strong>Monoblock Lever ValvesGeneral FeaturesStandard Material Specifications• High Strength Cast Iron• Hard Chrome Plated Interchangeable Spools• Steel Spring Caps• Aluminum Lever Caps• NBR Seals<strong>HV18</strong>-7-2CStandard Features• 3/4” 1 to 7 Spool Monoblock Valve• Adjustable Relief Valve (500-5000 psi)• Housed Knuckle Joint• Parallel Circuit• Double Action• Load Hold Check Valve<strong>HV18</strong>-7-2C<strong>HV18</strong> <strong>Series</strong> is a 18.5 gpm (70 lpm) monoblock valveavailable up to seven spools. Having the capacity of 18.5gpm <strong>HV18</strong> <strong>Series</strong> valves are used in larger machines andbigger pumps. Typical applications are: hydraulic presses,garbage and tipping trucks, hydraulic platforms, frontendloaders etc.General SpecificationsStandard Working Conditions• Flow Rate........................................................................................18.5 gpm (70 lpm)• Maximum Operating Pressure........................................................5000 psi (350 Bar)• Maximum Back Pressure................................................................435 psi (30 Bar)• Recommended Fluid Temperature Range......................................-4 o to 176 o F (-20 o to 80 o C)• Ambient Temperature Range..........................................................-31 o to 140 o F (-35 o to 60 o C)• Recommended Oil Viscosity Range...............................................10 cSt to 75 cSt• Internal Leakage (at 1450 psi (100 Bar); 32 cSt, 104 o F (40 o C)......4 to 9 cc/ min• Recommended Oil Filtering............................................................. 10 > 75• Maximum Contamination Level.......................................................Class 9 (NAS 1638)19/16 (ISO 4406)Technical Specifications• Number of Spools............................1 - 7• Weight..............................................Varies by number of spools selected (see following page)31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com


<strong>HV18</strong> <strong>Series</strong>Monoblock Lever ValvesMain Relief ValvePPP2P2Inlet with Main Relief ValveInlet without Main Relief ValveHydraulic CircuitParallel CircuitWhen the spool is operated, it intercepts theswitch gallery by diverting the flow of oil toservice port A or B. If two or more spools areactuated at the same time, the oil will powerthe service port that has the lower load byselecting the path with the least resistance;by throtting the spools, the flow of oil can bedivided between two or more service ports.P2P102A1 B1102A2 B2TT2<strong>Series</strong> CircuitWhen the spool is operated, it intercepts theswitch gallery by diverting the flow of oil toservice port A or B. The oil that flows backfrom the actuator is carried to the switchgallery thus making it available to the serviceports downstream from the series section.The pressure drop downstream is added tothe pressure drop of the section itself.P2P102A1 B1102A2 B2TT231341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com


Spool Control Position/ Pressure Drop Curves<strong>HV18</strong> <strong>Series</strong>Monoblock Lever ValvesP- TABSpool-neutral position:POSITION 00Pressure Drop bar (psi)16 (232)14 (203)12 (174)10 (145)8 (116)6 (87)4 (58)2 (29)65431 2No. of Sections030(7.93)40(10.57)50(13.21)60(15.85)70(18.49)80(21.13)Flowl/min (gpm)ABSpool-out position:POSITION 10 125 (363)P - A/BPressure Drop bar (psi)20 (290)15 (218)10 (145)5 (73)654321No. of SectionsABSpool-in position:POSITION 2030(7.93)40(10.57)50(13.21)Flow60(15.85)l/min (gpm)70(18.49)80(21.13)204 positions and 4th positioncan be spool-in or spool-outposition optionally:POSITION 33 20 1Pressure Drop bar (psi)14 (203)12 (174)10 (145)8 (116)6 (87)4 (58)2 (29)A/B - T65431 2No. of Sections2 01 3030(7.93)40(10.57)50(13.21)Flow60(15.85)l/min (gpm)70(18.49)80(21.13)31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com


<strong>HV18</strong> <strong>Series</strong>Monoblock Lever Valves<strong>HV18</strong> - 4 - 2 COrdering Information<strong>HV18</strong> <strong>Series</strong>Monoblock(Manual) Lever ValveSections1 = 1 Section2 = 2 Sections3 = 3 Sections4 = 4 Sections5 = 5 Sections6 = 6 Sections7 = 7 SectionsConfiguration2 = 3 position, spring centered4 = 3 position, detentedFunctionB = All Ports BlockedC = P to T, A & B BlockedF = P Blocked, A & B to TH = All Ports OpenOptionsHVHANDLE = Handle<strong>HV18</strong>-DK = Detent Kit<strong>HV18</strong>-PB = Power Beyond Sleeve<strong>HV18</strong>-CCP = Closed Center Plug<strong>HV18</strong>-IN-POR = Inlet Relief- Pilot Operated Relief227 (8.94)Units: mm (inches)31341 Friendship Drive, Magnolia, TX 77355 • Tel.: 281-259-7768 Fax: 281-259-7249 • www.hyvair.com