Technical Data Sheet<strong>BioTector</strong> ® Model <strong>990</strong>◗ Improved Technology with Accuracy better than + 3% of reading◗ High Speed Response < 6 mins◗ Upgradeable to Multi-component Analyser◗ An Investment That is Guaranteed to Pay for ItselfGeneral InformationDesigned to withstand corrosive environments, the<strong>BioTector</strong> ® <strong>990</strong> is housed in an FRP enclosurewith dual compartments to keep all electroniccomponents separate from the 'wet' or analysiscomponents. The <strong>BioTector</strong> ® <strong>990</strong> has a built-inmicrocontroller and is operated through a membranekeypad.FunctionsA sample from the stream is pumped into the<strong>BioTector</strong> ® reactor chamber. A patented two-stageoxidation method oxidises the organic material inthe sample. The carbon dioxide formed in thisoxidation process is then sparged and monitoredby the patented IR-detector. The measurementprocess can be described in four stages:1. SAMPLING: A representative unfiltered samplefrom the stream to be analysed is pumped intothe analyser. The sample injection valve automaticallyselects the appropriate sample volume forthe optimum measuring range.2. TIC DETECTION: Acid is added to lower thepH so that inorganic carbon may be sparged offas carbon dioxide. As the <strong>BioTector</strong> ® <strong>990</strong> actuallymeasures the level of TIC in the sample, it will notallow TIC to carry over into the TOC measurements.3. OXIDATION: The ozone generator is switchedon to generate ozone used in the reaction.Sodium hydroxide is added to raise the pH of thesample to the point where the production ofhydroxil radicals is optimised. In these conditions,total and effective oxidation takes place.4. TOC CALCULATION: To remove the carbondioxide from the oxidised sample, the pH of thesample is lowered again. The carbon dioxide issparged and measured by the IR-detector. Theresult is calculated and presented on screenand as a 4 - 20mA output. All data is stored inthe system’s archiveRaffeen House, Ringaskiddy,County Cork, IrelandTel: (Intl) +353 21 4374237Fax: (Intl) +353 21 4374236Email: info@pollution-control.ieDual compartment layout separates the electroniccomponents from the ‘wet’ or analysis components.MaintenanceNormal service frequency is 6 months. Separateservice kits are available for the 6-month and12-month service.


Technical Data Sheet<strong>BioTector</strong> ® Model <strong>990</strong>EnclosureDimensions (HxWxD)WeightPower consumptionMains connectionDisplayData storageOperationLanguage optionsFibreglass ReinforcedPolyester Color RAL 7035 (grey)1250 x 750 x 320mm90 kg300 W230V or 115V AC40 character x 16 linebacklit LCDPrevious 5000 reaction data.Previous 50 fault signals.Microprocessor withMembrane KeyboardEnglishGermanFrenchNorwegianSwedishDutchOther languages on requestMonitoringPrincipleMonitoringParameterMonitoringFrequencyMonitoring RangeRepeatabilitySample Volume2 stage Advanced Oxidationof organic material withhydroxil radicalsTOCTICTCAfter correlation tests:CODBODBatch SamplesMinimum Frequency - 5 min.Automatic Range Selectionbetween 0 - 10mgC/l to0 - 25000mgC/l, withoutdilution or recalibration± 3% of reading or + 0.5mg0.1 - 8.0 mlParticle size Up to 2 mm Ø,soft particulatesFiltrationNot requiredRequirementsSignal Drift < 5% per yearAmbient Temperature 2 - 30 O CentigradeHumidity10 - 80%, non-condensingChloride interference NoneStandard outputAlarm outputSerial portTIC outputFlow inputRemote Pause signalCleaning cycle valveMultistream outputEExp4(0) - 20mA3 Bi-polar potential freecontacts, programmableRS232 output for printeror data loggerOPTIONAL FEATURES4 - 20 mA signal for TIC4 - 20 mA signal forflow inputInput for remote pauseValve for cleaningcycle fluid6 streams with independent4 - 20mA signals for up to3 streamsZone II approval.Zone I optional.Acid & BaseOxgenServiceReplacement frequency upto 16 weeks - applicationdependantOption of Integrated OxygenGenerator available6 months intervalsThe <strong>BioTector</strong> ® <strong>990</strong> comes with up to 24 monthswarranty against manufacturing errors.Pollution Control Systems Limited have a continuous research and developmentprogramme. Specifications may therefore be changed without notice.For specification updates, please contact Pollution Control Systems.Raffeen House, Ringaskiddy,County Cork, IrelandTel: (Intl) +353 21 4374237Fax: (Intl) +353 21 4374236Email: info@pollution-control.ie

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!