13.07.2015 Views

tronic 36 - WIKA

tronic 36 - WIKA

tronic 36 - WIKA

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>36</strong> Hour TurnaroundModular AssemblyProven TechnologyCustomized PressureTransmitters in <strong>36</strong> HoursR


Over 200,000possible transmittercombinations in<strong>36</strong> hours!<strong>WIKA</strong> TRONIC <strong>36</strong> is a program offering customizedpressure transmitters built within <strong>36</strong> hours!Designed for <strong>WIKA</strong> C-10 and S-10 pressure transmitters, this modularprogram provides over 200,000 possible combinations to fit your specificneeds.Benefits:• Custom designs built in <strong>36</strong> hours*• Flexible options to meet your specificapplication needs• In-house production of sensors in piezoor thin film technology (assembled in the USA)• <strong>WIKA</strong>’s trusted performance and quality engineeringHow it works:Use the TRONIC <strong>36</strong> flexible modular assembly system to select componentsthat meet your specific needs: output, pressure unit, pressure range,process connection, electrical connection and cable length. Each selectionhas a corresponding alpha-numeric code (see options at right). Thisgenerates a <strong>WIKA</strong> type code for ordering your custom transmitter, which isassembled, tested and shipped within <strong>36</strong> hours.C-10- A - PBC - NQ - ZM5ZAbove is an example <strong>WIKA</strong> type code generated from the availableoptions of the C-10. Use your custom code when requesting a quotation orwhen placing your order.The TRONIC <strong>36</strong> program offersjust-in-time pressure transmittersolutions custom built in <strong>36</strong> hours!*<strong>WIKA</strong> reserves the right to limit order quantities. Completion time in <strong>36</strong> hours is available when allselected components are in stock. Rush charges may apply. Contact factory for additional information.OutputA 4-20 mAG 0-5VF 0-10VW 0.5-4.5VRatiometricOutputA 4-20 mAG 0-5VF 0-10VW 0.5-4.5VRatiometricType S-10 Standard Industrial - 0.25% AccuracyS-10 - - - - - Z G -1 2 3 4 5 6 7 8Pressure UnitP psi3 psi AbsN InWCThese rugged pressure transmittersare designed for usein harsh environments whereaccuracy, reliability, and repeatabilityare critical. Applicationsinclude hydraulics, pneumaticsand numerous other processingoperations.Type C-10 OEM - 0.5% AccuracyPressure UnitP psi3 psi AbsN InWCFeaturing a highly stable, temperature-compensatedand conditionedoutput signal, the <strong>WIKA</strong>C-10 is specifically designedto meet OEM requirements.Applications include hydraulics,pneumatics, compressor control,off-road equipment and industrialengine control.Pressure RangeCACDCFCHCKCLGGGUCNCPBCCQBDDABEBFBGBHDGBIBKDIBLDJBNBOBPBQBSDSPressure RangeGUCNCPBCCQBDDABEBFBGBHDGBIBKDIBLDJBNBOBPBQBSDS(A)30 INHG Vac30 INHG-0-30 psi30 INHG-0-60 psi30 INHG-0-100 psi30 INHG-0-160 psi30 INHG-0-200 psi0-50 INWC0-100 INWC0-5 psi0-10 psi0-15 psi (A)0-25 psi (A)0-30 psi0-50 psi (A)0-60 psi0-100 psi (A)0-160 psi0-200 psi0-250 psi (A)0-300 psi0-400 psi0-500 psi0-600 psi0-750 psi0-1000 psi0-1500 psi0-2000 psi0-3000 psi0-5000 psi0-8000 psi0-100 INWC0-5 psi0-10 psi0-15 psi (A)0-25 psi (A)0-30 psi0-50 psi (A)0-60 psi0-100 psi (A)0-160 psi0-200 psi0-250 psi (A)0-300 psi0-400 psi0-500 psi0-600 psi0-750 psi0-1000 psi0-1500 psi0-2000 psi0-3000 psi0-5000 psi0-8000 psiavailable inabsolutepressureProcess ConnectionNDNQNBNPNHNRUAUBUEUFUCUD(A) available inabsolute pressureProcess ConnectionNDNQNBNPNHNRUAUBUEUFUCUD1/2” male NPT1/2” female NPT1/4” male NPT1/4” female NPT1/8” male NPT1/8” female NPT7/16-20 SAE #4 J514 male7/16-20 SAE #4 J514 female9/16-18 SAE #6 J514 male9/16-18 SAE #6 J514 female3/4-16 SAE #8 J514 male3/4-16 SAE #8 J514 female1/2” male NPT1/2” female NPT1/4” male NPT1/4” female NPT1/8” male NPT1/8” female NPT7/16-20 SAE #4 J514 male7/16-20 SAE #4 J514 female9/16-18 SAE #6 J514 male9/16-18 SAE #6 J514 female3/4-16 SAE #8 J514 male3/4-16 SAE #8 J514 femaleElectrical ConnectionA4 DIN 43 650AX DIN 43 650 1/2”female conduitH1 DIN 43 650 withmolded cableO4 4 pin MIL plugC6 6 pin MIL plugB5 5 pin binder-type plugM5 5 pin M12x1DL Cable with free endsNEMA 4 / IP 67Electrical ConnectionIIH2M5B5DIMiniDINMiniDIN withmolded cable5 pin M12x15 Pin Binder-type plugCable with free endsNEMA 5 / IP 65Cable LengthZYno cable5 foot cable(only with H1 or DL)3 30 foot cable(only with DL)C-10 - - - - - Z -1 2 3 4 5 6 7Cable LengthZ no cableY 5 foot cable(only withH2 or DI)3 30 foot cable(only with DI)


For over 60 years, <strong>WIKA</strong> Instrument Corporation(<strong>WIKA</strong>) has continued to globally advance pressuregauge, sensor and temperature instrumentationtechnology and applications. In the United States,<strong>WIKA</strong>’s operation utilizes state-of-the-art manufacturingtechnology and highly automated proprietaryproduction equipment in its nearly quarter-millionsquare-footfacility in the metro Atlanta suburb ofLawrenceville, Georgia.C-10<strong>WIKA</strong> Instrument Corporation1000 Wiegand BoulevardLawrenceville, GA 30043Toll Free 1-888-<strong>WIKA</strong>-USA (945-2872)Tel (770) 513-8200 Fax (770) 338-5118<strong>tronic</strong>@wika.com • www.wika.com/<strong>tronic</strong>B016 - 2500 Rev 2 05/09S-10© <strong>WIKA</strong> Instrument Corporation.All rights reserved.As the industry leader in lean manufacturing, <strong>WIKA</strong> offersa wide variety of stock and customized instrumentationsolutions for critical applications that often are distributedwithin days. The <strong>WIKA</strong> customer service departmentrecently earned the Operational Excellence Award forLeadership from one of North America’s leading distributorsof industrial maintenance, repair and operationreplacement parts. Producing over 40 million gauges,diaphragm seals, transmitters, and thermometers worldwideannually, <strong>WIKA</strong> has the most extensive product linein the industry.R

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!