13.07.2015 Views

Plus Family 30kVA to 500kVA - United Power & Battery

Plus Family 30kVA to 500kVA - United Power & Battery

Plus Family 30kVA to 500kVA - United Power & Battery

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DC Expert TM provides state of charge and dynamicallyupdates battery time remainingDisplays up <strong>to</strong> 400 of the most recent events. All data isaccessible via modemOperational metering features: True RMS sensing of voltage and current Real-time displayIntelligent alarm management — event record separatesinformational notices from situations requiring opera<strong>to</strong>rinterventionperformance& reliability30 - 80kva - shown with safety sheilds removedABRedundant power supplies support control logic for reliableonline operation and provide local and remote failure notification.Intelligent input filter disconnects from rectifier input with loss of utilityand low load conditions, providing superior genera<strong>to</strong>r compatibility.CStatic switch assembly can be removed for servicing withoutinterrupting the critical load. All electrical connections feature quickdisconnects for safe access.DStandard dual feed inputs for 480V and 400V increase availability(optional for other voltages).ERedundant fans ensure direct consistent cooling, quiet operation andprovide local and remote failure notification.FInternal wireway with standard <strong>to</strong>p and bot<strong>to</strong>m entry access allowsinstallation flexibility.GAll power wiring is secured <strong>to</strong> magnetics with maintenance-free, coldwelded connections, eliminating periodic re<strong>to</strong>rquing of fasteners andrear access requirements.H Intelligent controls incorporating digital signal processing provide 5%output THD, ±1% output voltage regulation, programmable operatinglimits and failure proof make-before-break bypass transfers.I2x rated neutral supports higher currents associated withnon-linear loads.305mm (12”)JOutput terminals: The output isolation transformer provides commonmode noise rejection and qualifies as a separately derived source(with isolated neutral) whether online, on battery or on bypass(<strong>Plus</strong> 40-160); mechanical connec<strong>to</strong>rs on all input and output terminalsreduce installation time.KModular design and construction places all serviceable componentswithin a 305mm (12”) depth for easy maintenance. Only requires frontaccess for servicing convenience and low mean time <strong>to</strong> repair.LStandard DC interface cable provides plug and play capability(<strong>Plus</strong> 40-160) with matching battery cabinets.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!