13.07.2015 Views

Actionpac EMB – Bespoke Control and Monitoring System - Actionair

Actionpac EMB – Bespoke Control and Monitoring System - Actionair

Actionpac EMB – Bespoke Control and Monitoring System - Actionair

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

February 2010<strong>Actionpac</strong> <strong>EMB</strong><strong>Actionpac</strong> <strong>EMB</strong> <strong>–</strong> <strong>Bespoke</strong><strong>Control</strong> <strong>and</strong> <strong>Monitoring</strong> <strong>System</strong><strong>EMB</strong> <strong>–</strong> <strong>Bespoke</strong><strong>Control</strong> <strong>and</strong> monitoring system<strong>Actionpac</strong> Electro MechanicalSmoke <strong>and</strong> fire damper controlsystem.Automatic damper operationutilising relay logic <strong>and</strong> LEDindication of damper status.FeaturesCustomised central <strong>Control</strong> Panel.Individual, or collectivelycontrolled <strong>and</strong> continuallymonitored.Wall mounted enclosure to IP55.Finished in RAL 7035.Custom Engraved Traffolytefascia.LED indication of damper status.Zonal inputs.Door interlocking isolator.Miniature circuit breakerprotection.Specialist Panels availableFan <strong>Control</strong> Panel.Fireman’s control panel.Mimic (Repeater) Panel.Fire damper monitor (Indication)panel.Panels Designed <strong>and</strong> Built in Britain.


<strong>Actionpac</strong> <strong>EMB</strong><strong>Actionair</strong> <strong>Actionpac</strong> <strong>EMB</strong> <strong>–</strong> <strong>Bespoke</strong>Electro-Mechanical <strong>Control</strong> <strong>and</strong> <strong>Monitoring</strong> <strong>System</strong>IntroductionThe <strong>Actionpac</strong> <strong>EMB</strong> <strong>Control</strong> <strong>System</strong>,consists of a number of smoke/firedampers hard wired individually or ingroups to a central control panel. Thedampers may be individually orcollectively controlled <strong>and</strong> continuouslymonitored.Dampers <strong>and</strong> control modes may havediffering control <strong>and</strong> monitoringrequirements <strong>and</strong> therefore will beconnected to the site wiring, which wheninstalled by the contractor, shall providethe relevant specified functions.SpecificationThe <strong>Actionair</strong> <strong>Actionpac</strong> <strong>EMB</strong> <strong>Control</strong> Paneltypically consists of the appropriate numberof switches to provide individual or groupcontrol, LED indication for status monitoring<strong>and</strong> all necessary relays <strong>and</strong> timers tocomply with the customers needs for fully orsemi- automatic damper operation.Interface with the Fire Alarm panel is viavolt-free contacts which are normallyclosed <strong>and</strong> open upon alarm, the<strong>Actionair</strong> <strong>Actionpac</strong> <strong>EMB</strong> damper controlpanel will then activate relevant dampersto their alarm status.<strong>Actionair</strong> Damper <strong>Control</strong> Panels arepurposely manufactured for anyparticular project to suit specific customerrequirements.<strong>Actionpac</strong> <strong>EMB</strong>, as supplied by<strong>Actionair</strong>Features<strong>EMB</strong> <strong>–</strong> <strong>Bespoke</strong> Damper control panelsare purposely manufactured for anyparticular project to suit specific customerrequirements.Dampers can be individually or collectivelycontrolled <strong>and</strong> continually monitored.Wall mounted enclosures to IP55.Finished in RAL 7035Custom engraved traffolyte fascia.LED indication of damper status.Zonal inputs.Door interlocking isolator.Miniature circuit breaker protection.OptionsLockable glazed door.Special paint finish to BS st<strong>and</strong>ard colourreference numbers.Flush mounting flanges.Latching push buttons.Fireman’s override key switches.Test switch.Lamp test.Audible alarm with mute facility.B.M.S common fault relay interface.B.M.S output.Delay timers.Battery backup.Specialist panels available● Fan <strong>Control</strong> Panel● Fireman’s <strong>Control</strong> Panel● Mimic (Repeater) Panel● Fire damper monitor (indication) panelExample <strong>Actionpac</strong> <strong>EMB</strong> Panel shownPanel Enclosure sizesNo. of Dampers Estimated enclosuresize (mm)W x H x D1 - 4 400 x 400 x 2105 - 8 400 x 400 x 2109 - 12 500 x 500 x 21013 - 16 500 x 500 x 21017 - 20 600 x 600 x 21021 - 30 600 x 600 x 21031 - 40 600 x 800 x 21041 - 50 800 x 800 x 2102 www.actionair.co.uk


<strong>Actionpac</strong> <strong>EMB</strong>Typical <strong>Actionpac</strong> <strong>EMB</strong> Electro-Mechanical<strong>System</strong> SchematicIncorporating Smoke/Shield PTC (<strong>Control</strong> Mode 5 illustrated)SUPPLY 230V 1phDAMPER SUPPLY* 24V ACFor wiring <strong>and</strong> application details on thevarious <strong>Actionair</strong> damper <strong>and</strong> controloptions, please refer to relevant productbrochure on our website atwww.actionair.co.uk* 230V AC if Mode 61FIRE ALARMPANEL(By others)21ACTIONPAC <strong>EMB</strong>ELECTRO-MECHANICALCONTROL PANEL2345SMOKE/SHIELD PTCCONTROL MODE 5FIREMANSOVERRIDEPANEL(By others)† 24V DC3 CORE INDICATIONBACK FROM EACHINDIVIDUAL MODE 56† 24V DC Mode 5 or Mode 6INTERFACE :1 No. VOLT FREE CONTACT PER ZONE1 X 2 CORE CABLE PER INTERFACE1 x 3 CORE BMSRELAY OUTPUT(NORMAL/FAULT)CONTROL MODE LOCALCONNECTION BOXSEE ACCESSORIES (DCB)Commissioning<strong>Actionair</strong> offers a comprehensive aftersales service to include for precommissioningchecks, completecommissioning service of all ourAccessoriesproducts in line with <strong>and</strong> to encompassCIBSE guidelines <strong>and</strong> plannedpreventive maintenance visits.DCB Connection Box For <strong>Control</strong>Modes. (Can be factory prewired to<strong>Control</strong> Mode, all voltages.)Size: 100 x 100 x 50mm.For damper quantities in excess of 50,please refer to <strong>Actionair</strong> <strong>Actionpac</strong> LNS60/120, or <strong>Actionair</strong> <strong>Actionpac</strong> LNS3brochures on our website, or contactour Technical Sales Office.Description Voltage Part Number informationDCB 24V <strong>–</strong> 230V AC/DC XNNN00312www.actionair.co.uk3


<strong>Actionpac</strong> <strong>EMB</strong>Other <strong>Actionpac</strong> Damper <strong>Control</strong> <strong>System</strong>sElectro Mechanical <strong>System</strong>sAddressable <strong>System</strong>sEMS <strong>–</strong> St<strong>and</strong>ard<strong>Control</strong> <strong>and</strong> monitoring system.<strong>Actionpac</strong> Electro Mechanical smoke <strong>and</strong>fire damper control system.Automatic damper operation utilising relaylogic <strong>and</strong> LED indication of damperstatus.St<strong>and</strong>ard Modular Construction.LED indication of damper status.Mains isolator.Test/Normal/Override Keyswitch.Lamp test facility.2 Versions (Mode 5 <strong>and</strong> Mode 6),available in 3 sizes, from Stock.Note:<strong>Actionpac</strong> EMS (St<strong>and</strong>ard) or <strong>Actionpac</strong> <strong>EMB</strong>(<strong>Bespoke</strong>) <strong>System</strong>s are recommended for areas wherethere are less than 50 dampers.<strong>Actionpac</strong> 60/120The <strong>Actionair</strong> <strong>Actionpac</strong> 60/120 (LNSSt<strong>and</strong>ard) <strong>System</strong> consists of a Panel PC,UPS <strong>and</strong> pre-loaded software. Thesystem communicates with damperinterfaces to provide intelligent control<strong>and</strong> monitoring of motorised dampers<strong>and</strong> monitoring of manual fire dampers.The data network cabling enablessubstantial reduction in costs whencompared with conventional systems.The digital inputs <strong>and</strong> output device(DI804) is accommodated within thepanel enclosure.The Panel PC is supplied with <strong>Actionair</strong><strong>Actionpac</strong> 60/120 (LNS St<strong>and</strong>ard)software <strong>and</strong> operates on an embeddedplatform, which is extremely user friendly.The server architecture delivers newbenefits such as reduced commissioningtime, ease of configuration, simplifiedoperation, full diagnostics for system <strong>and</strong>device integration along with optionalautomatic scheduled damper testing.Note: <strong>Actionpac</strong> 60/120 is recommend when there aremore than 50 smoke/fire dampers to be controlled <strong>and</strong>monitored. Refer to <strong>Actionpac</strong> 60/120 (LNS St<strong>and</strong>ard)brochure for full details.<strong>Actionpac</strong> LNS3The <strong>Actionpac</strong> LNS3 <strong>System</strong> consists ofa Panel PC, UPS <strong>and</strong> pre-loadedsoftware. The system communicates withdamper interfaces to provide intelligentcontrol <strong>and</strong> monitoring of motoriseddampers <strong>and</strong> monitoring of manual firedampers. The data network cabling enablessubstantial reduction in costs whencompared with conventional systems.Digital inputs <strong>and</strong> outputs (DI804) can beaccommodated on the network cable orlocated within the panel enclosure.The Panel PC is supplied with <strong>Actionpac</strong>LNS3 software <strong>and</strong> operates on anembedded platform, which is extremelyuser friendly. The server architecturedelivers new benefits such as reducedcommissioning time, ease ofconfiguration, simplified operation, futuresystem growth, full diagnostics for system<strong>and</strong> device integration along with optionalautomatic scheduled damper testing.Ruskin Air Management LimitedSouth Street, Whitstable, KentCT5 3DU Engl<strong>and</strong>.Tel: 01227 276100Fax: 01227 264262Email: sales@actionair.co.ukWebsite: www.actionair.co.ukRuskin Air Management Limitedis a ISO 9001 <strong>and</strong> 14001registered companyBROCHURE PRODUCTION www.geoffstrange.co.uk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!