13.07.2015 Views

ALPN, APPN, AGPN Series - Matelco

ALPN, APPN, AGPN Series - Matelco

ALPN, APPN, AGPN Series - Matelco

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Class I, Div. 1 and 2Groups B,C,DClass II, Div. 1 and 2Groups E,F,GClass IIINEMA 4,4X,7BCD,9EFGP-11<strong>APPN</strong> <strong>Series</strong> Power Distribution Panelboards:Explosionproof, Dust-Ignitionproof, WatertightNon-Factory Sealed.PSAMPLE CAT. NO.A PPN A13 B12 M1 ▲BRANCH CIRCUITS. (See footnote)MAIN TYPE: M1 = 100A FrameM2 = 225A FrameML = Main Lug OnlyNUMBER OF CIRCUITS: 12, 18, 24, 30, 36 & 42WIRE SYSTEM: B = 3P 3WC = 3P 4WVOLTAGE: 3 = 480V4 = 277/480V (3P 4W Only)CURRENT RATING: 1 = 100A2 = 225APANEL SIZE: A = 161606B = 162206C = 162806D = 153707F = 184207DUTY: PPN: Non-Factory Sealed Power PanelAPPLETONTypical Panelboard Wiring DiagramThree-Phase, 4-Wire Systems277/480V Approx.No. of 3 Phase 4 Wire Panel WeightCircuits GHB Type Size (lbs)12 <strong>APPN</strong>A14C12ML▲ A 135100 Amp 18 <strong>APPN</strong>B14C18ML▲ B 165Main Lug Only 24 <strong>APPN</strong>C14C24ML▲ C 21030 <strong>APPN</strong>C14C30ML▲ C 21518 <strong>APPN</strong>C24C18ML▲ C 18024 <strong>APPN</strong>C24C24ML▲ C 230225 Amp 30 <strong>APPN</strong>C24C30ML▲ C 235Main Lug Only 36 <strong>APPN</strong>D24C36ML▲ D 29042 <strong>APPN</strong>D24C42ML▲ D 29512 <strong>APPN</strong>C14C12M1▲ C 165Main Breaker 18 <strong>APPN</strong>C14C18M1▲ C 180100AF 24 <strong>APPN</strong>D14C24M1▲ D 21030 <strong>APPN</strong>D14C30M1▲ D 31518 <strong>APPN</strong>C24C18M2▲ C 18524 <strong>APPN</strong>D24C24M2▲ D 295Main Breaker 30 <strong>APPN</strong>D24C30M2▲ D 300225AF 36 <strong>APPN</strong>D24C36M2▲ D 30542 <strong>APPN</strong>F24C42M2▲ F 345Note: For Back Fed main, replace ML, M1, or M2 in part number with BF. For 400A MainLug, consult factory. Standard interrupting capacity is 14,000 AIC. For higher interrupt ratings,consult factory.▲ Select branch breakers as desired in panel. First and second digits are the quantity ofbreakers, third and fourth digits are ampere rating, the fifth digit is number of poles.Example: An 18 circuit 277/480V 1 phase 3 wire 100A MLO panel with 12 single pole 20amp and 3 two pole 30 amp branch breakers should read <strong>APPN</strong>B14C18ML-12201-03302.Factory Installed OptionsDescriptionBreather, NEMA 4X, 7 & 9Drain, NEMA 4X, 7 & 9Phenolic Nameplate(Specify Legend)SuffixBRDNNPEffective September, 2005Copyright 2005800-621-1506www.appletonelec.comPAGE 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!