e integrated into the power distribution systemA <strong>Schneider</strong> <strong>Electric</strong> innovation,Quick PRD, Quick PF and Combi PRF1«built-in» technology <strong>surge</strong> <strong>arrester</strong>sincorporate their own disconnection circuitbreaker:easy to choose and simple to install forgreater effectiveness.For all low voltage switchboards andelectrical enclosures,a range of <strong>surge</strong> <strong>arrester</strong>s that is simpleto install.The effectiveness of lightning protection is closely related to theimplementation of its <strong>surge</strong> <strong>arrester</strong>s.To ensure the protection of equipment connected to• low voltage networks,• telecommunications networks,• computer networks,<strong>Schneider</strong> <strong>Electric</strong> has designed a complete range of <strong>surge</strong><strong>arrester</strong>s that can be perfectly integrated into the enclosuresand electrical switchboards of its switchgear assembly andinstallation systems.• Certified coordination between the <strong>surge</strong> <strong>arrester</strong> and itsdisconnection circuit breaker,• Protection against the nuisance tripping of “si” and “SiE”earth leakage protection devices during a lightning strike,• Easy to implement and use,• Compatibility with all earthing systems (TT, TNS, TNC, IT),• Technical and aesthetic consistency,• Compliance with standards,• Availability of products and services.


<strong>Schneider</strong> <strong>Electric</strong>is at your side dayby day and hasdesigned simple,practical toolsto help you quicklyselect andimplementthe right lightningprotection:• product <strong>catalog</strong>ue<strong>Schneider</strong> <strong>Electric</strong>, a range for allyour applicationsLightning protection 3P + NSurge <strong>arrester</strong> Reference DisconnectorQuick PRD 40r 16294 integratedQuick PRD 20r 16297 integratedQuick PRD 8r 16300 integratedQuick PF 16618 integratedCombi PRF1 16629 integratedPRF1 Master 16630 (x4) NS 106 N TM160DPRD65r 16559 C60N or H C50PRD40r 16564 C60N or H C40PRD40 16569 C60N or H C40PRD20r 16674 C60N or H C25PRD20 16574 C60N or H C25PRD8r 16679 C60N or H C20PRD8 16579 C60N or H C20PF65r 15685 C60N or H C50PF65 15586 C60N or H C50PF40r 15690 C60N or H C40PF40 15688 C60N or H C40PF20 15693 C60N or H C25PF8 15696 C60N or H C20Lightning protection 1P + NSurge <strong>arrester</strong> Reference Disconnector• uselectionassistancesoftwareQuick PRD 40r 16292 integratedQuick PRD 20r 16295 integratedQuick PRD 8r 16298 integratedQuick PF 16617 integratedCombi PRF1 16626 integratedPRF1 Master 16630 (x2) NS 106 N TM160DPRD65r 16557 C60N or H C50PRD40r 16562 C60N or H C40PRD40 16567 C60N or H C40PRD20r 16672 C60N or H C25PRD20 16572 C60N or H C25PRD8r 16677 C60N or H C20PRD8 16577 C60N or H C20PF65 15684 C60N or H C50PF40 15687 C60N or H C40PF20 15692 C60N or H C25PF8 15695 C60N or H C20Telecommunications and computer equipment protectionSurge <strong>arrester</strong>ReferencePRC 200V 16593PRI


With <strong>Schneider</strong> <strong>Electric</strong>,lightning protection can easily«90% of power outlets supply equipmentincorporating electronic devices.»<strong>Schneider</strong> <strong>Electric</strong>is today one ofthe leading globalbrands of powerdistributionequipment.In the quest forever greatersafety andcontinuity ofservice, theranges arechanging to meetall residential,tertiary andindustrialprotectionrequirements.More and more electrical equipmentis today sensitive to overvoltages causedby lightning strikes.In response to these new requirements,<strong>Schneider</strong> <strong>Electric</strong>, the leading powerdistribution manufacturer, is devoting itsefforts to lightning protection.To make it easier to select <strong>surge</strong> <strong>arrester</strong>s for electrical installationsand to implement and maintain them, 550 specialists design andproduce <strong>surge</strong> <strong>arrester</strong>s in compliance with international standards.<strong>Schneider</strong> <strong>Electric</strong>’s <strong>surge</strong> <strong>arrester</strong>s are highly suitable for electricalcontractors and meet their users’ most stringent requirements.From Grenoble to Salt Lake City, from Brussels to Shanghai,quality requirements are being pushed to the limit.Each site has obtained ISO 9001 and/or ISO 14001 certification.


<strong>Schneider</strong> <strong>Electric</strong>,helping professionals to chooTo meet allprotectionrequirementsmoreeffectively:1Estimatethe value of theequipment to be protected• residential buildings• domestic equipment:• audio-video equipment,computers,• electrical appliances,• burglar alarm.• tertiary buildingsThe value is estimatedby considering:• the financial costof the equipment• the economic impactof equipment downtime• building equipment:• fire alarm, access control,• automated heating orair-conditioning,• lift.• business equipment:• programmable machine,• server,• sound or light control system.• heavy equipment:• medical infrastructure,• production infrastructure,• heavy computer processing.• industrial buildings2Determinethe type of building• detached house,• flat, small semi-detached house,• common areas of a building,• professional premises.Lightning protection canbe calculated for an entirebuilding or for part of abuilding that is electricallyindependent.


se the best lightning protectionAs proof ofthe completeeffectivenessof lightningprotectionin meetingeach need,3Identifythe type of powerdistributionIntegration into the electrical powerdistribution:• single switchboard or main switchboard,• subdistribution board,• sensitive equipment more than 30 mfrom the switchboard.<strong>Schneider</strong> <strong>Electric</strong>offers a simpleand effectiveselection method.Depending on the sizeof the building and theextent of its electricalsystem, one or more <strong>surge</strong><strong>arrester</strong>s must be used inthe various switchboardsin the installation.4Understandthe risk of the impactof lightning on the siteLocation of the building:• in an urban, suburban, groupedhousing area.Lightning is attracted byhigh points that conductelectricity. They can be:• natural: tall trees, mountainpeaks, damp areas, ferroussoils.• artificial: chimney stacks,aerials, pylons, lightningrods.Indirect effects can be incurredwithin a fifty metre radius aroundthe point of impact.• in plain area.• in an area where there is aspecial risk (pylon, tree,mountainous region, mountainpeak, damp area or pond).• in an exceptionally exposed area(lightning rod within 50 metresof a building).


PRF1, PRD, PF <strong>surge</strong> <strong>arrester</strong> selection guide1EQUIPMENT TO BE PROTECTEDcommon equipmentComputers,electrical appliances,audio-video equipment,burglar alarm,etc.building equipautoairacce2TYPE OFBUILDING3TYPE OFPOWERDISTRIBUTIONDetachedhouseFlat, smalsemi-detachedhouseCommon areasof a buildingProfessionalpremisesSingleswitchboardormainswitchboard+Subdistributionboard4RISK OF THE IMPACTOF LIGHTNINGCHOICEQUICKPFPF40CombiPRF1+ PF40CombiPRF1+ PF40QUICKPFPF40PF65PRF1Master+ PF40PRF1Master+ PF40QUICKPFPF40CombiPRF1+ PF40CombiPRF1+ PF40QUICKPRD20rQUICKPRD40rQUICKPRD40rCombi PRF1ouPRF1 Master+Quick PRD4ALTERNATIVEPF20 PF40 PF40Combi PRF1 oPRF1 Master+PF40Choice of disconnectors to be associated with the <strong>surge</strong> <strong>arrester</strong>sThe choice of a disconnector that is 100% coordinated with the <strong>surge</strong> <strong>arrester</strong> ensures complete safety at the eSurge <strong>arrester</strong>swith integrated disconnectorOther <strong>surge</strong> <strong>arrester</strong>s: choice of associate6kA10kAQuick PRD 1P+NIcc = 25 kAQuick PRD 3P+NIcc = 25 kAPRD8PF8C60N 20ACurve CC60H 20ACurve CPRD20PF20C60N 25ACurve CC60H 25ACurve CQuick PF 1P+NIcc = 6 kAQuick PF 3P+NIcc = 6 kAPRD40PF40C60N 40ACurve CC60H 40ACurve CPRD65PF65C60N 50ACurve CC60H 50ACurve CCombi PRF1 1P+NIcc = 6 kACombi PRF1 3P+NIcc = 6 kAPRF1MasterNS 160N 160A


mentFire alarm,mated heatingor-conditioning,lift,ss control, etc.business equipmentProgrammablemachine,server,sound orlight controlsystem, etc.heavy equipmentMedical,production,or heavy computerprocessinginfrastructure,etc.+ + + + +Dedicatedprotection,more than30 m from aswitchboardSingleswitchboardor mainswitchboardSubdistributionboardDedicatedprotection,more than30 m from aswitchboardSingleswitchboardor mainswitchboardSubdistributionboardDedicatedprotection,more than30 m from aswitchboard0rQUICKPRD20rQUICKPRD8rQUICKPRD40rPRD65PRD65Combi PRF1ouPRF1 Master+Quick PRD40rQUICKPRD20rQUICKPRD8rPRD65Combi PRF1+ QuickPRD40rCombi PRF1ouPRF1 Master+Quick PRD40rCombi PRF1ouPRF1 Master+Quick PRD40rQUICKPRD20rQUICKPRD8ruPF20PF8PF40 PF65 PF65Combi PRF1 ouPRF1 Master+PF40PF20PF8PF65Combi PRF1+PF40Combi PRF1 ouPRF1 Master+PF40Combi PRF1 ouPRF1 Master+PF40PF20PF8nd of life phase of the <strong>surge</strong> <strong>arrester</strong>.d disconnector15kA 25kA 36kA 70kAIccProtection of telecommunications andcomputer equipmentLightning can also propagate throughtelecommunications and computer networks.It can damage all the equipment connected to thesenetworks: telephones, modems, computers, servers,etc.Contact usChoice of PRC and PRI <strong>surge</strong> <strong>arrester</strong>s PRC PRIContact usAnalogue telephone networks