13.07.2015 Views

dry cabinets - ITECO

dry cabinets - ITECO

dry cabinets - ITECO

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Humidity SolutionProviderDRY CABINETBAKING 40°CRH-TEMP MONITORDATA LOGGERVACUUM PACKAGINGenglish


DRY CABINETSX2E type is a plug and play, fully auto-<strong>dry</strong> cabinet which will be stable at less than 5%RH. There is no need to set the panelbuttons at all. It is especially designed for moisture sensitive devices (MSD) packages to comply with IPC/JEDEC J-STD-033B.8105.003 (X2E-240N)capacity: 240L-2 shelvesED: W600xD715xH685Shelf size: W555xD570xH208105.011 (X2E-1200N)capacity: 1280L-5 shelvesED:W1200xD672xH1815Shelf size: W1155xD5358105.005 (X2E-315N)capacity: 328L-3 shelvesED: W905xD452xH1045Shelf size: W860xD360xH20Humidity Range:£5%RH%Colour:blackVoltage:230VDisplay Precision: RH%: ±3,°C: ±1Software:Humidity Manager V3 for drawing the curve of RH andtemperature.Structure: 1mm thick carbon steel with antistatic paint. Wheel:Door: Compression handles, airtight magnetic sealers and Grounding Wire:antistatic glass.ESD Paint:8105.009 (X2E-600N)capacity: 650L-5 shelvesED: W600xD672xH1815Shelf size: W555xD535xH204 antistatic 3” wheels, two of themwith brakes.1 . (940 mm long)10 3 ~10 9 W. (surface resistance)2Optionals8105.1358105.136Data Logger DL-5Data Logger DL-5-1(3900 records)(40000 records)8105.1408105.130Data Reader DLR-5Humidity Manager Software V3


H/T MONITORING SYSTEMMonitor H/T inside the cabinet:Every cabinet can be connected directly to a PC (with aRS232 or USB cable) to acquire Humidity andTemperature data.In alternative you can connect it to our datalogger(8105.135 or 8105.136) to store temporaly the data.After you can get the data into the PC using our datareader (8105.140).Monitor H/T in the environments:To acquire Humidity and Temperature data inproduction or other environments you can use AlarmHygrometer HT-1B or HT-5B. Like every cabinet theycan be connected directly to a PC or a datalogger.MSD Floor Life Counter"Floor Life" is the allowable time period after removal from amoisture barrier bag, <strong>dry</strong> storage or <strong>dry</strong> bake and beforethe solder reflow process.-Data interval can be set from1 second to 99 minutes-Graphing and analyzing data with Humidity Managersoftware v. 3 for Windows.WithHumidity Manager Software V. 3 for Windows you can:- Automatically calculate the time intervals and percentage thatexceed the 10%RH or 5%RH which leads to the estimation of theMSD floor life.- Automatically calculate the total period and the expired date ofthe Data Logger.According to IPC/JEDEC J-STD-033B standard. For moisturesensitivity Level 2, 2a, 3 with floor life exposure not greater than12 hours, a minimum desiccating period of 5X the exposure timeis required to <strong>dry</strong> the MSD packages enough to reset the floor lifeclock.For moisture sensitivity Level 4, 5, 5a with floor life exposure notgreater than 8 hours, a minimum desiccating period of 10X theexposure time is required to <strong>dry</strong> the MSD packages enough toreset the floor life clock.8105.130 Humidity Manager V3 H/T monitoring software (OPTIONAL)H/T DATA LOGGER/READERdata loggerFunction:Data Logger can record H/T data and transfer the data toPC via Data Reader and then the software HumidityManager will show the H/T curves. Interval of dataacquisition can be set by software Humidity Manager.Specifications:Memory: 3,900 records ( standard )40,000 records ( option )data readerDimensions: W73*D35*H20 mm ( Logger )W120*D75*H50 mm ( Reader )Display:Port to PC:LCD with back lightUSB 1.1Colour:blackOptionals8105.135 Data Logger DL-5 (3900 records)8105.136 Data Logger DL-5-1 (40000 records)8105.1408105.130Data Reader DLR-5Humidity Manager Sotware V33


BAKING 40°C DRY CABINETFunction: T40-1200-6N is a plug and play, fully auto <strong>dry</strong> cabinet which will be stable at 40°C and5%RH. It is especiallydesigned for moisture sensitive devices (MSD)Wider application in resetting the floor life: Moisturesensitive devices (MSD) packages which are exposed to theair and exceed the floor life should be stored in the T40-1200-6N for resetting the floor life. (see IPC/JEDEC J-STD-033Btable 4-1, 4-3)For example: If MSD parts of MSD Level 4,5 and 5a areexposed for less than eight hours, they can be stored in a <strong>dry</strong>cabinet for resetting the floor life.However, if their exposure time is longer than eight hours, theMSD packages should be stored at 40°C in a T40-1200-6N toreset the floor life.Labor saving: MSD packages shipped in low temperaturecarriers may not be baked in a traditional high temperatureoven with the temperature higher than 40°C, as it will causedeformation of the carriers. Storing in a T40-1200-6N,operators do not need to remove the MSD package tothermally safer carriers. It saves labor cost and eliminates thechance of damaging the carriers.Specifications:Temperature & Humidity Range:40±2°C; £5%RHCapacity:Shelves:1280 L5 shelvesColor:blackVoltage:Display Precision:230VacRH%: ±3, °C: ±1Software: Humidity Manager V3temperature.for drawing the curve of RH andStructure:1mm thick carbon steel with antistatic paint.Door: Compression handles, airtight magnetic sealers and antistaticglass.Wheel:4 antistatic 3” wheels, two of themwith brakes.Grounding Wire:1 . (940 mm long)ESD Paint:103~10 9 W. (surface resistance)Baking 40°C Dry Cabinet is suitable for ambient temperature >15°C8105.021(T40-1200-6N)capacity: 1280L-5 shelvesED: W1200xD740xH1790Shelf size: W1110xD490xH204Optionals:8105.135 Data Logger DL-5 (3900 records)8105.136 Data Logger DL-5-1 (40000 records)8105.1408105.130Data Reader DLR-5Humidity Manager V3


COST DOWN N2 CABINETNitrogen filling Module (8105.110) will stop as soon as the preset relative humidity value is reached, so N2 consumptioncan be saved from70 to 90%.Any of traditional nitrogen cabinet can be upgraded by adding NC-2 Digital Nitrogen Controller (8105.109) within 20minutes. And then huge waste of nitrogen can be saved permanently.Energy Saving Nitrogen CabinetIt's equipped with the modules as below:Digital Nitrogen ControllerCan be installed on the the top of a nitrogen cabinet:8105.2008105.2108105.109(2)Dry Units: absorb moisture to10%RH(option)8105.110(1)Digital NitrogenController(infeed clean and <strong>dry</strong>nitrogen)NC-2(3)QDN:N2 auto Nitrogen FillingModule(infeed clean and <strong>dry</strong> nitrogen)8105.1108105.109Filling Module QDN:N2NC-2 - External N2 controller8105.1118105.210N2 Flow MeterDrying unit(optional)8105.111Flow Meter: will be installedoutside of QDNWe accept customized requirementsData Logger and Reader withHumidity Managment software V3ALARM HYGROMETER - floor life controlAlarm Hygrometer is installed at precisely controlled environment and productionline of high end electronic components, optical and medical industries.It displays the temperature and RH and alerts the engineers to check and repair thefacilities immediately by flash or buzzer alarm that is activated as soon as thetemperature or RH exceeds the preset tolerance.Up to 32 sets of AlarmHygrometers can be connected to a PC through intranetnetwork. All of the data of temperature and RH will be recorded and the fluctuationwill be shown in the graph.HT-1BHT-5BStandard features:Operating Range -20 +50°C / 90%Rh - Precision +-0.5°C / +-3%Rh - Resolution 0.1°C / 0.1%RhCalibration reminding - Alarm buzzer - Alarm flash - RS232 port - Humidity manager software V2,78105.101 Alarm Hygrometer HT-1B W220xH90xD55mm - visibility distance 6m8105.105 Alarm Hygrometer HT-5B W310xH320xD70mm - visibility distance 30m8105.135 Data Logger DL-5 (3900 records)8105.136 Data Logger DL-5-1 (40000 records)8105.1408105.130Data ReaderHumidity Manager Software V3 (optional)5


EXTERNAL ASPIRATION VACUUM SEALERSWith these economic and flexible machines is possible to package everylength of bag. The unit is handoperated and the degree of vacuumis achieved by the operator’svaluation. The air is strongly suckedout fromthe bag’s opening, so it isneeded to use specific bags or tounfold the sides of the bags, so toprovide two little way out for theaspiration. (see drawing)1cm7914.359 Vacuumbag sealer, external aspiration, 450mmSeal length :450 mmSoldering jaws:2 x 6mmVacuumpump :Dry , 3m 3 /h.Noise:


MSD (moisture sensitive devices) HANDLINGUsual accidents that occurs to IC packages containing moisture, during the Reflow:The correct humidity management:- DRY ATMOSPHERE STORAGE: The Moisture Sensitive Devices that are exposed in the airshould be stored in a <strong>dry</strong>-cabinet in order to reset the floor life.For example : if MSD parts of MSD level 4 or 5 or 5a are exposed for less than 8 hours , they can bestored in a <strong>dry</strong> cabinet for resetting the floor life. However, if their exposure time is longer than 8hours, the MSD packages should be stored at 40°C in a Low Temperature Baking Cabinet to resetthe floor life.- STABLE PRODUCTION LINE ENVIRONMENT: The temperature and humidity of production lineshould be kept stable. A good solution is to install an Alarm Termo-Hygrometer connected to a PCto record all fluctuations. To alert the engineers to check and repair the facilities, a buzzer or flashalarm is activaded as soon as the temperature / humidity exceeds the preset tolerance.- FLOOR LIFE CONTROL: It is important to verify that the condition of storage complies withtheIPC/JEDEC J-STD-033B. The user can aquire data fromthe <strong>cabinets</strong> by using the RS232 portor the Data Logger & Reader group. With the data recording function, the historical fluctuation ofrelative humidity an temperature can be shown in a graph.With the patented monitoring software "Dr. Storage Floor Life" it is easy to verify if the MSDcomponents are stored at the proper condition.- DRY PACKING : the baked MSD components should be vacuum-sealed in an ESD Moisturebarrier bag with a Dessicant and a Moisture humidity indicator. Moderate vacuum is preferred; highvacuum can be detrimental by cracking the plastic support of the components and by reducing theeffectiveness of dessicant.MOISTURE BARRIER BAGS(100 pcs)Excellent in EMI/RFI and static field shielding, these bags are watervapor proof and grease proof. Used as packaging ofelectrostatic/humidity sensitive parts, disk drives, flat pack etc. Heatsealable, Moisture Barrier Bags are made from a multilayer metallizedfilm.We suggest to place inside the barrier bags a Moisture DesiccantBag to eliminate the residual moisture.Film complying:MIL-B-81705Gclass1 TC1 SBM356Rs:< 1x10 12 WElectrostatic decay:< 2 secMoisture absorbing desiccant bags7914.002 bags gr.12 1/3U-DIN (100 pcs)7914.005 bags Tyvek gr.34 1U-DIN(300 pcs)Opening on the short side Thickness 80umThickness 150um100 x 660 mm 7804.344 7804.344P150 x 660 mm 7804.347 7804.347P200 x 250 mm 7804.348 7804.348P250 x 660 mm 7804.350 7804.350P400 x 400 mm 7804.354 7804.354P400 x 660 mm 7804.353 7804.353P450 x 450 mm 7804.355 7804.355P450 x 660 mm 7804.356 7804.356P7914.008 3 spot humidity indicator card 5-10-60% ( 500pcs)7914.009 3 spot humidity indicator card 5-10-15% ( 200pcs)7914.010 4 spot humidity indicator card 10-20-30-40% ( 200pcs)7

Hooray! Your file is uploaded and ready to be published.