13.07.2015 Views

401/402-B - Bradford White

401/402-B - Bradford White

401/402-B - Bradford White

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Commercial Electric Water HeaterEnergy Saver ModelsMeet or exceed ASHRAE 90.1b (current standard) C.E.C. ListedModelNumberM-II-50(A)-kW-3SFM-II-80(A)-kW-3SFM-II-120(A)-kW-3SFModelNumberM-II-50(A)-kW-3SFM-II-80(A)-kW-3SFM-II-120(A)-kW-3SFModel numbers shown arefor Surface Mountthermostats.For Immersion thermostatchange suffix “SF” to “CF”.Voltage and phase must bespecified when ordering.Example: M-II-50-12-3SF,240 Volt, 3 phase.(A) ASME Constructionavailable.For ASME construction add“A” to the model number.Example: M-II-50A-12-3SF.CapacityU.S.Gal.5080119AHeightBJacketDia.DFloor toHot WaterOutletEFloor toCold WaterInletFFloor toTop ofControl BoxApprox.ShippingWeightlbs.Imp.Gal. in.in.in.in.in.Std. ASME4267100Capacity47 3 /460 1 /464 1 /2AHeight242630 1 /4BJacketDia.CHeightto T&PConn.in.4152 1 /255CHeightto T&PConn.mm.49 1 /461 3 /466Liters mm. mm.mm.mm.mm.Std. ASME189303450121315301638610660768Number of Elements (Fused Models)*208V 240V 277VPhase Phase PhaseInputkW 1 3 1 3 1691213.515182427303645543(2)333334666993333336666993(2)33(2)333466699333333666699333333466699380VPhase3333333666699104113341397415VPhase3333333666699480VPhase1 33(2)33(2)333466699DFloor toHot WaterOutlet333333666699125115681676600VPhase33333336666996 3 /46 3 /46 3 /4EFloor toColdWaterInlet17817817846 1 /246 1 /250 1 /4FFloor toTop ofControl Box118111811276Full Load Current Amperes (Fused Models)*208VPhase240VPhase277VPhase1 3 1 3 121.632.443.348.754.164.086.697.4108.328.843.257.664.972.186.516.625.033.337.541.650.025.037.250.056.262.572.014.421.628.932.536.143.4115.4 66.7129.8 75.0144.2 83.3100.0 57.8112.5 65.0125.0 72.2173.0 100.0 150.0 86.7216.3 125.0 187.5 108.3259.6 150.0 225.0 130.0129.9162.4194.9270335430122152195380VPhase310.014.019.021.023.028.037.041.046.055.069.083.0Approx.ShippingWeightkg.415VPhase39.013.017.019.021.025.034.038.042.050.0302378485137171220480VPhase1 3Units with amperage draw of 48 amps or more require factory installed internal fusing. *If the number of elementson non-fused models is different, it is located in parentheses ( ), following the amp draw.InputkW691213.5151824273036455463.075.012.518.725.028.131.237.550.056.262.575.093.7112.57.210.814.416.218.021.628.932.536.143.354.165.0600VPhase35.88.711.513.014.417.323.126.028.934.643.352.0COLD 52°HOTCOLD 58°13"19 1/2"HOT12"18 1/2"63°T & PHOT56°COLDT & P 45°47°T & P15 1/8"22 1/8"FEBCDAkW Input691213.515182427303645544062931241<strong>401</strong>55186248279310372465558RecoveryGPH Temperature Rise °F50 60 70 80 90 100 120 1405074991121241491992232482983724474162839310312416418620724831037235537180891061421601772132663193147627078931241<strong>401</strong>55186233279284255626983110124138165207248253750566274991121241491862232131414752628393103124155186Optional surface thermostats ranging from80°F to 140°F are available.182735404453718089106133160Sample SpecificationThe water heater shall be a <strong>Bradford</strong> <strong>White</strong> model with a rated storage capacity of not less than_______gallons (_______liters), a minimum kW input of_______kW (_______ BTU/Hr.), a minimum recovery of _______GPH (_______ LPH). The tank shall be Vitraglas ® lined and have a bolted hand hole cleanout. The tank shall have_______magnesium anode rods installed in separate tank head couplings. The heater shall have 3" Non-CFC foam insulation, and come equipped with an ASME rated T&P reliefvalve, a cold water inlet Hydrojet ® Sediment Reduction System. It shall be design certified by ETL for 180ºF (82ºC) application, either with or without a separate storage tank, andcomply with state and local codes and ordinances.GeneralAll electric water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All models are design certified by ETL, for up to 180°F (82°C)application as an Automatic Storage Heater, and an Automatic Circulating Tank Heater. As an Automatic Storage Heater, all models are complete, self-contained water heatingsystems. It needs no separate storage tank, pump, wiring or elaborate piping network. When equipped with a mixing valve, it will supply 180°F (82°C) sanitizing and lowertemperature general purpose hot water simultaneously. These models can be used either as a single unit or in multiples connected in series or parallel (recommended). Dimensionsand specifications subject to change without notice in accordance with our policy of continuous product improvement.Ambler, PAFor U.S. and Canada field service, contact your professional installer or local <strong>Bradford</strong> <strong>White</strong> sales representative.Sales 800-523-2931 ● Fax 215-641-1670 / Technical Support 800-334-3393 ● Fax 269-795-1089 ● Warranty 800-531-2111 ● Fax 269-795-1089International: Telephone 215-641-9400 ● Telefax 215-641-9750 / www.bradfordwhite.comSales / Technical Support 866-690-0961 / 905-238-0100 ● Fax 905-238-0105 / www.bradfordwhite.com©2013, <strong>Bradford</strong> <strong>White</strong> Corporation. All rights reserved.<strong>401</strong>/<strong>402</strong>B-1213-APrinted in U.S.A.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!