Types of mountingB3V9B5B14B6B9B3 / B5V5B3 / B14B15V1B7V18V1 / V5V8V18 / V5V6B8V3 / V6V3V19V19 / V6Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


General characteristicsIntroduction:This documentation describes the main technical characteristics of our explosion-<strong>proof</strong> <strong>motors</strong>.They have been designed according to ATEX N. 94/9/CE that concerns the essential safety characteristics of equipmentsintended to be used in potentially explosive atmospheres.The suitability of our explosion <strong>proof</strong> <strong>motors</strong>, to the essential safety characteristics dem<strong>and</strong>ed by the ATEX, is shown by theCE certificates issued by the CESI, notified body N. 0722: CESI 06 ATEX 059 IIB <strong>and</strong> CESI 06 ATEX 060 IIC.Definition:An explosion <strong>and</strong> <strong>flame</strong> <strong>proof</strong> motor Ex-d, Ex-de is a rotating machine which can work in an environment with the presence ofgases <strong>and</strong>/or explosive or inflammable fumes without causing internal damage to the motor. It is in fact:<strong>Explosion</strong>-<strong>proof</strong>: its housing neither cracks nor explodes in case of an inward short circuit.Flame-<strong>proof</strong>: it doesn’t allow the exit of gases <strong>and</strong> <strong>flame</strong> from the motor when the ambient temperature is critical.Introduction:Our explosion-<strong>proof</strong> <strong>motors</strong> Ex-d, Ex-de have been designed according to European st<strong>and</strong>ard Cenelec EN 60079-:2006; EN60079-1:2004; EN 61241-1:2004; EN 61241-0:2006 <strong>and</strong>, for this reason, they are suitable for hazardous areas as per CEI 64-2- EN 60079-10.14.17 st<strong>and</strong>ard.<strong>Explosion</strong> groups:Our <strong>motors</strong> have been certified for explosion group IIA - IIB - IIC <strong>and</strong> reproduce the following identification marks:GAS : zone 1 e 2 II 2G Ex-d (de) IIB (IIC)The st<strong>and</strong>ard EN 60079-0:2006 <strong>and</strong> EN 60079-1:2004 state the type of gases <strong>and</strong> vapours included in each explosion group(see the list in the bottom page).Ex-de <strong>motors</strong> = <strong>flame</strong><strong>proof</strong> enclosure, “d” for motor frame <strong>and</strong> increased safety <strong>and</strong> “e” for terminal box.DUST: zone 21 e 22 II 2D IP66 T 85° C, T 100° C, T 135° C, T 155° C according with st<strong>and</strong>ard EN 50281-1-1.Temperature classes:Our <strong>motors</strong> are certified for the temperature classes T3 - T4 - T5 (someT6). The ATEX st<strong>and</strong>ard settles the correlation between temperature class<strong>and</strong> maximum motor surface temperature, according to the following table:Main characteristics:- size 56 to 160mm- housing, shields <strong>and</strong> terminal box in cast iron- st<strong>and</strong>ard mechanical protection IP 55- fan cover protection IP 2x- the cooling fan is in non-sparking synthetical material up to 160- paint RAL 5010- screws: nickelled or cadmied- stainless steel nameplate- ball bearings type ZZ on both sides.Temperature classMaximum surfacetemperature (°C)T1 450T2 300T3 200T4 135T5 100T6 85Terminal box:It is located on the top with cable entry on NDE <strong>and</strong> can be rotated through 90°. St<strong>and</strong>ard <strong>motors</strong> have 2 cable entries withconical thread GAS GK UNI 6125 or Metric type thread.Motors with either space heaters, Clixon or PTC thermistors always have an extra cable entry.Voltage <strong>and</strong> frequency:Motors can be wound up to 660 V, 50 or 60 Hz.According to CEI st<strong>and</strong>ard, the rated operating voltage can st<strong>and</strong> a variation of ± 5% <strong>and</strong> the rated operating frequency canst<strong>and</strong> a variation of ± 2%, with the motor operating at the name-plate power.Grounding:Motors are provided with 2 earth screws: one on the terminal box, <strong>and</strong> one on the housing.Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


Vibration:Vibration values are within the limits of IEC 60034-14 <strong>and</strong> ISO 2373 grade st<strong>and</strong>ards, measured with half key in accordancewith ISO 8821. On request we can supply <strong>motors</strong> with vibration’s value R grade.Noise:St<strong>and</strong>ard noise level agrees with the requirements of IEC 60034-9 <strong>and</strong> ISO R 1680 st<strong>and</strong>ards.Output:The rated output indicated on the name plate applies to continuous duty S1, rated voltage <strong>and</strong> frequency, to max 40°C ambienttemperature <strong>and</strong> to an altitude of installation up to 1000 metres above sea level.Modifications of the output, due to temperature <strong>and</strong> altitude changes, are indicated in the following diagrams:Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


2 Pôles 3000 r.p.m <strong>single</strong> <strong>phase</strong>TYPE Rated output Speed Currant Efficiency Power factor Mn Capacity Is / In Ts / Tn T max WeightkW tr/min. A (230V) η % cos γ Nm µF M.N Kg.MAK-M 56-2 0,12 2703 0,97 52,72 0,981 0,42 5 2,35 0,44 1,54 7,2MAK-M- 63A-2 0,18 2836 1,47 60,23 0,894 0,61 5 3,03 0,41 2,13 10,3MAK-M- 63B-2 0,25 2834 1,85 65,39 0,891 0,84 6,3 2,95 0,49 1,75 11,3MAK-M- 71A-2 0,37 2897 2,80 69,01 0,837 1,22 8 3,83 0,38 2,24 15,3MAK-M- 71B-2 0,55 2912 4,20 69,47 0,819 1,80 12,5 4,27 0,45 2,30 16,3MAK-M- 80A-2 0,75 2842 5,02 70,89 0,919 2,52 16 3,38 0,37 1,66 22,3MAK-M- 80B-2 1,1 2810 6,90 77,1 0,884 3,74 20 3,95 0,45 3,63 24,3MAK-M- 90S-2 1,1 2936 6,89 76,49 0,922 3,58 31 5,73 0,48 3,22 29,4MAK-M- 90L-2 1,5 2778 9,22 76,11 0,936 5,16 35 3,3 0,67 2,70 32MAK-M 100LA-2 2,2 2903 13,17 79,41 0,954 7,24 40 2,92 0,36 2,1 45,4MAK-M 100LB-2 3 2853 18,39 78,05 0,928 10,04 50 3,96 0,55 2,38 46,8MAK-M- 112M-2 4 2850 25,30 72,04 0,953 13,40 75 4,89 0,6 1,90 56,44 Pôles 1500 r.p.m <strong>single</strong> <strong>phase</strong>TYPE Rated output Speed Currant Efficiency Power factor Mn Capacity Is / In Ts / Tn T max WeightkW tr/min. A (230V) η % cos γ Nm µF M.N Kg.MAK-M- 56-4 0,09 1310 0,86 51,3 0,885 0,66 5 2,25 0,51 1,8 7,2MAK-M- 63A-4 0,12 1416 1,20 53,74 0,806 0,81 5 2,37 0,56 2,00 10,3MAK-M- 63B-4 0,18 1408 1,65 54,59 0,866 1,22 8 2,54 0,57 1,95 11,3MAK-M 71A-4 0,25 1407 1,85 62,43 0,929 1,70 6,3 2,82 0,43 1,56 15,3MAK-M- 71B-4 0,37 1391 2,65 64,60 0,937 2,54 8 2,79 0,45 1,43 16,3MAK-M- 80A-4 0,55 1418 4,12 64,00 0,908 3,70 12,5 2,81 0,42 1,60 23,3MAK-M- 80B-4 0,75 1415 5,05 73,86 0,875 5,06 14 3,04 0,33 1,89 24,3MAK-M- 90S-4 1,1 1341 6,40 74,78 0,988 7,83 31 2,5 0,46 1,77 29,4MAK-M- 90L-4 1,5 1363 9,48 72,72 0,936 10,51 40 2,76 0,35 1,80 32MAK-M 100LA-4 2 1404 12,47 74,68 0,933 12,47 45 2,85 0,53 2,46 44,4MAK-M 100LB-4 2,2 1450 12,75 81,45 0,935 14,49 55 4,41 0,20 2,18 47,4MAK-M 112M-4 3 1406 17,25 79,69 0,951 20,38 55 3,61 0,19 1,82 60,46 Pôles 1000 r.p.m <strong>single</strong> <strong>phase</strong>TYPE Rated output Speed Currant Efficiency Power factor Mn Capacity Is / In Ts / Tn T max WeightkW tr/min. A (230V) η % cos γ Nm µF M.N Kg.MAK-M 63B-6 0,06 918 0,69 38,71 0,935 0,62 4 1,63 0,7 1,12 12,3MAK-M 71B-6 0,18 901 1,28 61,41 0,977 1,91 8 2,04 0,16 1,32 16,3MAK-M- 80A-6 0,25 900 2,30 56,40 0,852 2,65 10 2,30 0,40 1,80 22,8MAK-M 80B-6 0,37 940 2,92 60,31 0,893 3,76 10 2,78 0,33 1,77 24,8MAK-M- 90S-6 0,55 870 4,50 59,50 0,858 6,04 18 2,20 0,41 1,30 29,4MAK-M- 90L-6 0,75 888 5,09 68,26 0,931 8,07 25 2,09 0,59 1,50 31,4MAK-M 100LB-6 1 958 6,16 74,10 0,967 9,97 45 4,03 0,34 1,44 43,4MAK-M 112M-6 1,5 925 9,20 75,50 0,947 15,49 35 3,03 0,34 1,00 57,4Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


Mounting B14/B34Type A AA AB AC AD AF B BB BF C D DA E F GA GD H HA HD K L LL M N P S T IC-GK56 A 90 22 105 110 120 91 71 90 103 36 9 M3 20 3 10,2 3 56 6 176 6 200 43 65 50 80 M5 2,5 1X1/2”63 A/B 100 30 120 125 138 101 80 100 113 40 11 M4 23 4 12,5 4 63 7 201 7 250 72 75 60 90 M5 2,5 1X1/2”71 A/B 112 31,5 140 140 147 101 90 110 113 45 14 M5 30 5 16 5 71 8 218 7 284 80 85 70 105 M6 2,5 1X1/2”80 A/B 125 39 155 158 157 131 100 130 140 50 19 M6 40 6 21,5 6 80 9 237 10 328 86 100 80 120 M6 3 1X3/4”90 S 140 34 170 177 165 131 100 130 140 56 24 M8 50 8 27 7 90 9 255 10 364 102 115 95 140 M8 3 1X3/4”90 L 140 34 170 177 165 131 125 155 140 56 24 M8 50 8 27 7 90 9 255 10 384 102 115 95 140 M8 3 1X3/4”100 LA/LB 160 45 196 200 184 131 140 170 140 63 28 M10 60 8 31 7 100 12 284 12 440 127 130 110 160 M8 3,5 1X3/4”112 M 190 48 224 222 206 151 140 170 162 70 28 M10 60 8 31 7 112 12 318 12 456 130 130 110 160 M8 3,5 2X1”B5/B14 special mountingB5 reducedFrame size C D M N P S71 57 (*) 115 95 140 1080 71 (*),(**) 130 110 160 1290 71 (*) 130 110 160 12100 76 (*) 165 130 200 15112 83 (*) 165 130 200 15B14 specialFrame size C D M N P S71 45 (*) 115 95 140 M880 50 (*),(**) 130 110 160 M890 56 (*),(**) 130 110 160 M8100 63 (*),(**) 165 130 200 M8112 70 (*),(**) 165 130 200 M10Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


Single <strong>phase</strong> <strong>motors</strong> capacities dimensionType MAK-M 63 71 80 90 100 112J 23 40 / / / /W / / 30 30 50 60Y 120 110 115 135 155 160Output shafts dimensionsType D d1 d2 d3 t1mm mm mm mm mm56 9j6 M3 3,2 5,3 1263 11j6 M4 4,3 6,7 1471 14j6 M5 5,3 8,1 1780 19j6 M6 6,4 9,6 2190 24j6 M8 8,4 12,2 25100 28j6 M10 10,5 14,9 30112 28j6 M10 10,5 14,9 30Balance degree according IEC 34.14 - ISO 2373Balance degree Speed Limit value of the vibration speeds from 10 to 1000HzMotor size 56-132 160N (Normal) 600 - 3600 1.8 2.8R (reduced)600-1800 0.71 1.121800-3600 1.12 1.8S (special)600-1800 0.45 0.711800-3600 0.71 1.21Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


Single-<strong>phase</strong> motor connection diagramsEntrée des câbles pour alimentation moteur monophaséFrame size St<strong>and</strong>ard On dem<strong>and</strong>UNI6125 IEC 423 DIN 40430 ANSI B1.20.156 - 71 1 x 1/2” GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2” NPT80 - 100 1 x 3/4” GK 1 x M 25 x 1.5 1 x PG 21 1 x 3/4” NPT112 1 x1” GK 1 x M 32 x 1.5 1 x PG 29 1 x 1” NPTAuxiliaires cables entryFRAME SIZE STANDARD ON DEMANDUNI6125 IEC 423 DIN 40430 ANSI B1.20.163 - 112 1 x 1/2” GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2” NPTCable entry for <strong>single</strong>-<strong>phase</strong> motor’s supplyMOTOR SIZE STANDARD ON DEMANDUNI6125 IEC 423 DIN 40430 ANSI B1.20.156 - 71 1 x 1/2” GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2” NPT80 - 100 1 x 3/4” GK 1 x M 25 x 1.5 1 x PG 21 1 x 3/4” NPT112 1 x1” GK 1 x M 32 x 1.5 1 x PG 29 1 x 1” NPTAuxiliary cables entryMOTOR SIZE STANDARD ON DEMANDUNI6125 IEC 423 DIN 40430 ANSI B1.20.163 - 112 1 x 1/2” GK 1 x M 20 x 1.5 1 x PG 13.5 1 x 1/2” NPTRue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384


SpecificationSpare parts1. Drive end shield2. Frame3. Shaft with rotor4. Key5. No drive end shield6. Cooling fan7. Cover fan8. Terminal box9. Terminal board10. Flange11. Rubber12. Rectify screw13. Terminal box cover -14. Ball bearings -15. Spring washer -16. Sealing ring -17. Flange B5 -Rue du Château d'Eau - 69410 CHAMPAGNE AU MONT D'OR - France - Tel :+33.(0)4.78.66.89.50 - Fax:+33.(0)4.72.29.13.86E Mail : lambert.moteurs@wanadoo.fr - www.lambertmoteurs.comS.A.S au capital de 40.000 € - Sirène RCS Lyon 381 998 384 00030 - APE 4669A - GESTION 91 B 1414 - No Identification TVA FR 13381998384