<strong>SSPA</strong> <strong>Remote</strong> <strong>Control</strong> <strong>Panel</strong>RCP-2001IntroductionThe RCP-2001 allows you to easily monitor and control an Antenna-Mount solid-state power amplifier (<strong>SSPA</strong>) or othersingle-module <strong>SSPA</strong> from a remote location. The RCP-2001 enables the remote, real-time operation of a single <strong>SSPA</strong>,which is especially convenient for installations where the <strong>SSPA</strong> is located in an inaccessible or inconvenient location.Features• User-friendly menu structure for <strong>SSPA</strong> controlcommands and status display• Provides customer Serial I/O port (up to 28.8 kBps)• Audible alarm• Worldwide AC input capability• Can be located up to 1.3 km (4000') from <strong>SSPA</strong> withinexpensive cable• Compatible with all Antenna-Mount <strong>SSPA</strong>s withfirmware version 2.0x or higherPart Number/Ordering InformationRCP-2001Options1 Rack Slides3 Parallel I/O5 DC Power 24 V6 DC Power 48 VOrder cable ACAB-13135-X separately(where ‘X’ denotes length in feet, in 50 ftincrements).Front <strong>Panel</strong>ONLINE 1RF ONRCP-2001PREVWARNINGGAINMODIFYMENUFAULTONLINE 2MUTESELFAULTRESETRear <strong>Panel</strong>85-264 V47-63 HzSERIAL I/O<strong>SSPA</strong> LINKAUXOPTION 3 PARALLEL I/OJ1J2RCP-2001VX.XXJ3J4FOR CONTINUED PROTECTION AGAINST FIRE,REPLACE ONLY WITH SAME TYPE AND RATINGOF FUSE.Connector InterfaceRef. Des. Function Connector Type Mating Connector CommentJ1 AC In IEC 320 IEC Cordset Standard" DC In 4-pin MS, Male 4-pin MS, Female Option 5 or 6J2 Serial I/O 9-pin D, Female 9-pin D, Male StandardJ3 <strong>SSPA</strong> Link 9-pin D, Male 9-pin D, Female StandardJ5 Parallel I/O 37-pin D, Male 37-pin D, Female Option 3


SpecificationsParameter Notes Min. Nom./Typ. † Max. UnitsPower Requirements Voltage, Standard 85 265 VacFrequency 47 63 HzPower 13.5 WVoltage, Option 5 20 32 VdcVoltage, Option 6 42 56 VdcOperating Temperature Range 0 +50 °C<strong>SSPA</strong> Link Cable Length 4000 (1.3) ft (km)Size 19 W x 1.72 H x 17.52 D inches482.6 x 43.7 x 445 mm†When there is only one value on a line, the Nom./Typ. column is a nominal value; otherwise it is a typical value. Typical values areintended to illustrate typical performance, but are not guaranteed.Parallel I/O (Option 3)The RCP-2001's parallel I/O (Option 3) provides eight independent contact-closure inputs and eight Form 'C' outputs.Each input or output is easily configured via the RCP-2001's front panel display and an extensive menu of <strong>SSPA</strong>control and status monitoring options.Inputs *No functionUser Fault (Active High)User Fault (Active Low)MuteUn-MuteMute/Un-Mute ToggleMute (Low)/Un-Mute (High)RF Inhibit (Active Low)RF Inhibit (Active High)Fault ResetOutputs *No function (user-defined function)Output Power Fault (High or Low)Voltage FaultAny Fault<strong>Remote</strong>/Local ModeMaintenance ModeRF InhibitRF On/OffMute/OperateAny WarningAny Fault or WarningTemperature FaultCurrent FaultRatingsInputs:Contact closure to ground(5 V/5 mA)Outputs:Form 'C' dry contacts100 V/0.5 A/3 W maximum* Additional functions may be offered for <strong>SSPA</strong>s with optional hardware features.Other Products• Low Noise Amplifiers and LNA Systems• Solid-State Power Amplifiers and <strong>SSPA</strong> Systems• <strong>General</strong> Purpose Converters• Satellite Communications Equipment• Custom Subsystems60 Decibel Road, Suite 200 • State College, PA 16801 USA • Tel. 814 238 2700 • FAX 814 238 6589 12724 Rev. A ECR 7991 4/11/07 MDBWeb Site: www.gdsatcom.com/electronics.php© <strong>General</strong> <strong>Dynamics</strong>. All rights reserved. <strong>General</strong> <strong>Dynamics</strong> reserves the right to make changes to its products and specifications at any time and without notice.All trademarks indicated as such herein are trademarks of <strong>General</strong> <strong>Dynamics</strong>. All other product and service names are the property of their respective owners.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!