Hardness <strong>Testing</strong> SystemTH180S37TT100/110/120/130Digital Micro Vickers Hardness Tester TH710/711Digital Micro Vickers Hardness Tester TH714/715Digital Viclers Hardness Tester TH720/721Universal Hardness Tester TH722


Ultrasonic Flaw Detector50.Ultrasonic Flaw Detector TUD31051.Ultrasonic Flaw Detector TUD36053.Ultrasonic Flaw Detector TUD500Magnetic Flaw Detector75.Magnetic Yoke Flaw Detector TCJE-2A76.Magnetic Yoke Flaw Detector TCEE-Ⅰ77.Magnetic Yoke Flaw Detector TCXX-3B78.Low-frequency Magnetic Flaw DetectorTCLF-J50D/Z12D56 TIME Micro- Printer TA230


Measuring range (170-960)HLD (17.9-69.5)HRCHardness scaleHLD,HS,HB,HRB,HRC,HVMeasuring direction 360°ToleranceRepeatabilityDiameter for printer paperWidth for printer paperPowerCharging time±6HLD(when HLD=760)6HLD(when HLD=760)40mm44.5±0.5mm12V/600mmA2-3.5 hourHumidity ≤90%Operating temperature 0℃~40℃Weight(g) 615Dimensions(mm) 235×90×47


Hardness scaleHL, HRC, HRB, HV, HB, HSMemory 240-1000 readings (Impact times: 32-1)Measuring rangeTensile strength U.T.S. rangeAccuracyStatistics functionStandard Impact DeviceOptional Impact DevicesMax. Workpiece HardnessMin. Radius of Workpiece(convex/concave)Min. Workpiece weightsee page8374~2652 MPa±6HLD (760±30HLD) error of displayedvalue6HLD (760±30HLD) repeatability ofdisplayed valueAverage / Max / Min value calculation,limits setting and alarmDDC/DL/C/D+15/G996HV(For Impact Devices D/DC/DL/D+15/C)646HB(For Impact Device G)Rmin = 50mm (with support ring Rmin=10mm)2~5kg on stable support0.05~2kg with compact coupling5mm (Impact Device D/DC/DL/D+15)Min. Workpiece thicknessMin. thickness of hardenedsurfacePowerContinuous Working timeCharging time1mm (Impact Device C)10mm (Impact Device G)0.8mmRechargeable Li BatteryAbout 100h (no printing and backlight)2.5~4 hoursOperating temperature 0~40℃Humidity 90%Overall dimensions(mm) 230×90×46.5Weight(g)420 (including Impact Device andprinter)


Model TH170 TH172 TH174Impact Device D integrated C integrated DL integratedHardness scalesHLD, HB, HRC, HRB,HV, HSHLC, HB, HRC, HRB, HV, HSAccuracy ±6HLD(760 ±30HLD) ±12HLC ±12HLDLHLDL, HB, HRC, HRB,HV, HSMemory270 average readings in 9 group filesOutput RS 232 to printer RS232 to printer RS232 to printerMin. Surface Roughness of Workpiece1.6μm ( Ra) 0.4μm ( Ra) 1.6μm ( Ra)Max. Work piece Hardness 900HLD 960HLC 950HLDLMin. radius of Work piece(convex/concave)Min. Work piece weightRmin = 50mm (withsupport ring Rmin=10mm)2~5kg on stable support0.05~2kg with compactcouplingRmin=11mm (with support ring )0.5~1.5kg on stable support0.02~0.5kg with compact couplingMin. Work piece thickness coupled 5mm 1mm 5mmMin. Thickness of hardened layers 0.8mm 0.2mm 0.8mmRmin = 10mm (withsupport ring Rmin=10mm)2~5kg on stable support0.05~2kg with compactcouplingIndentation depth Impact Devices data Impact Devices data Impact Devices dataContinuous working timePower150h (without backlight)AAA 1.5V batteriesOperating temperature 0~40℃ 0~40℃ 0~40℃Overall dimensions(mm) 155×55×25 160×60×25 215×60×25Weight(g) 166 180 180


Material Hardness Scale RangeSteel and Cast SteelGrey Cast IronCast Aluminum AlloysHBHRBHBHBHBHRB90~64647.7~99.992~326127~36432~16823.8~85.5Impact deviceImpact energyWork modeDisplayMeasuring rangeErrorRepeatabilityMeasuringdirectionHardness scalesMemoryInterfaceG type90mJUsed single or system mode (Can be connectedto TH180, as a slave unit)OLED screen, 320×240 dot matrix, brightnessadjustable200~750HLG±12HLG12HLG360°HLG、HB、HRB200 average valueUSBData outputTransfer data to PCTransfer data to TH180Operatingvoltage3.3VOperatingtemperature0~40℃Relative humidity ≤90%Transmissiondistance10 mDimensions(mm) 254 × 50 × 40Weight(g) 310


Measuring range170~960HLD<strong>Testing</strong> direction 360℃Hardness scaleHL、HRB、HB、HRC、HV、HSMemory2500 group data of main unit,500 groupdata of slave unitLimit setting170~960HLDPrinter paperWidth:57.5mm, diameter: 40mmPrinting speed5.03~22.23mm/sCharging time6h(main unit) ,2.5h(slave unit)PowerContinuous workingtime12V/4A(main unit), 6V/400mA(slaveunit)12h(main unit), 50h(slave unit)Relative humidity 90%Environmenttemperature0~40℃Wirelesstransmission distance10mDimensions(mm)260mm×170mm×57(main unit),145mm×35mm×30(slave unit)Weight (g)1070g(main unit), 120g(D unit)


TH180TYPE D/C/DL SLAVE UNIT7Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures●Type D/C/DL can beselected as slave unitfor TH180.●Dot matrix LCDdisplay,with cleardisplay and richinformation.●Transfer the data tothe main unit throughwireless.●Identify impact directionautomatically.●The upper and lowerlimit of hardness numbercan be set by the main unit.●Impact times can be preset tosatisfy various requirement ofcustomer.●Rechargeable Li battery.●Type D:for normal hardnesstestingType C: for hardness testingon thin, light and facehardenedworkpieceType DL: for hardness testingof deep grooves and mouldfacesuch as tooth surface)workpieces.Standard Delivery●Slave unit1●Power adapter 1●Cleaning brush 1●Instruction manual 1●TIME certificate 1●Warranty card 1Model Type D Type C Type DLMeasuring range 170~960HLD 230~960 HLC 560~950 HLDLMeasuring direction 360° 180° 360°Tolerance ±6HLD ±12HLC ±12HLDLSurface roughness of workpiece(Ra) ≤1.6 ≤0.4 ≤1.6Min.workpiece weight2~5kg on stablesupport0.05~2kg withcompact coupling0.5~1.5kg on stablesupport0.02~0.5kg with compactcoupling2~5kg on stable support0.05~2kg with compactcouplingMin.workpiece thickness with coupling 5mm 1mm 5mmMin.thickness of hardened layers 0.8mm 0.2mm 0.8mmIndentation depthScalesDisplayRange of impact timesCharger powerWorking timeCharging timeSee page9HL、HB、HRB、HRC、HV、HS112×48 dot matrix LCD1~9 optional6V/400mA>8 hours2~3 hoursPower 3.7VCommunication standardsRFDimensions(mm) 145×35×30 203×35×30Weight(g) 110 115 130


PortableHardnessTester8Beijing TIME High Technology Ltd.www.timeinstrument.comD DC DL C D+15 GMeasuring range of TIME Leeb hardness testerMaterialHardness test methodImpact deviceD/DC D+15 C G E DLHRC 20.0~68.4 19.3~67.9 20.0~69.5 22.4~70.7 20.6~68.2RockwellHRB 38.4~99.8 47.7~99.9 37.0~99.9Steel and cast steelHRA61.7~88.0Brinell HB 81~654 80~638 80~683 90~646 83~663 81~646Vickers HV 81~955 80~937 80~996 84~1042 80~950Shore HS 32.5~99.5 33.3~99.3 31.8~102.1 35.8~102.6 30.6~96.8Cold work tool steelRockwell HRC 20.4~67.1 19.8~68.2 20.7~68.2 22.6~70.2Vickers HV 80~898 80~935 100~941 82~1009Rockwell HRB 46.5~101.7Stainless steelBrinell HB 85~655Vickers HV 85~802RockwellHRCGrey cast ironBrinell HB 93~334 92~326VickersRockwellHVHRCNodular cast ironBrinell HB 131~387 127~364VickersHVCast aluminium alloysBrass(copper-zincalloys)Brinell HB 19~164 23~210 32~168Rockwell HRB 23.8~84.6 22.7~85.0 23.8~85.5Brinell HB 40~173Rockwell HRB 13.5~95.3Bronze(copperaluminium/copper-tinalloys)Brinell HB 60~290Wrought copper alloys Brinell HB 45~315


10Beijing TIME High Technology Ltd.www.timeinstrument.comOptional Support RingsFunction: they are used for tested surface whose curvature radius isless than 30mm (D, DC, D+15, C impact devices) or less than 50mm(G impact device) .UNZHZKHKSupport RingsNo. Type Sketch of non-conventional supporting ring Remarks1 Z10-152 Z14.5-303 Z25-504 HZ11-135 HZ12.5-176 HZ16.5-30For testing cylindrical outsidesurface R10~R15For testing cylindrical outsidesurface R14.5~R30For testing cylindrical outsidesurface R25~R50For testing cylindrical insidesurface R11~R13For testing cylindrical insidesurface R12.5~R17For testing cylindrical insidesurface R16.5~R307 K10-15For testing spherical outsidesurface SR10~SR158 K14.5-30For testing spherical outsidesurface SR14.5~SR309 HK11-1310 HK12.5-1711 HK16.5-30For testing spherical insidesurface SR11~SR13For testing spherical insidesurface SR12.5~SR17For testing spherical insidesurface SR16.5~SR3012 UNFor testing cylindrical outsidesurface, radius adjustable R10~∞


11Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Button batteries 1.5V 3●TIME certificate 1●Instruction manual 1●Warranty card 1Optional Accessories●RS232 communication cable●Operating stand TH200FJOperation stand TH200FJFeatures●Digital durometer for Shore A hardness testingof soft rubber, plastics and such substances●Pocketsize model with integrated probe●Standards: DIN 53505, ASTM D 2240, ISO7619, JIS K7215●RS232 data output●Operating stand optional●Bright & clear LCD display●Automatically switch off●Battery low indication and alarmTechnical SpecificationModelTest scale availableStandardsDisplayData outputMeasuring rangeTH200Shore ADIN 53505, ASTM D2240, ISO 7619,JIS K7215Hardness result, Average value,Max value(Peak value lock),BatteryindicationRS2320~100HATorlerance±1HADisplay resolution0.2HAOperating temperature 0~40 ℃Power supply3×1.5V (SR44) Button batteriesBuilt-in power adapter300 hoursDimensions(mm) 168×31×30TH200SHORE HARDNESS TESTERWeight(g) 144With the operation stand, users can get good measurement accuracyand repetitiveness,constant measurement force, eliminate the errorscaused by artificially applied different force.The operation handle evenly applies the force to the sample; adjusts thetesting height to meet the measurement of different sample thickness.


12Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●AC-DC power adapter 1●TIME certificate 1●Instruction manual 1●Warranty card 1Optional Accessories●RS232 communication cable●Operating stand TH210FJOperation stand TH210FJFeatures●Digital durometer for Shore D hardness testingof hard rubber, plastic and such substances●Pocketsize model with integrated probe●Standards: DIN 53505, ASTM D 2240, ISO7619, JIS K7215●RS232 data output●Operating stand optional●Bright & clear LCD display●300 hours continuous use with standardbatteries●Automatically switch off●Battery low indication and alarmTechnical SpecificationTest scaleavailableStandardsDisplayData outputMeasuringrangeMeasurementdeviationDisplayresolutionShore DDIN53505, ASTMD2240, ISO 7619, JIS K7215Hardness result, Average value, Max. value(Peakvalue lock), Battery indicationRS2320-100HDWithin 20~90 HD, error≤±1HD0.2 HDOperatingtemperaturePower supplyDimensions(mm)0~40 ℃Built in 3.7V rechargeable battery173× 56×42Weight(g) 233TH210SHORE HARDNESS TESTERWith the operation stand, users can get good measurement accuracyand repetitiveness. Constant measurement force, to eliminate the errorscaused by artificially applied different force.The operation handle evenly applies the force to the sample; adjust thetesting height to meet the measurement of different sample thickness.


13Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Operating stand 1●Handle 1●Weight 1●Connecting rod 1●Instruction manual 1●TIME certificate 1●Warranty card 1TH200FJFeatures●With the operating stand, users can get good measuremtaccuracy and repetitiveness●Constant measurement force eliminate the errors caused byartificially applied diffrent force●The operation handle evenly applies the force to the sample;adjust the testing height to meet the measuremnt of diffentsample thicknessTH210FJTechnical SpecificationModel TH200FJ TH210FJMax. thickness of sample(mm) 80Max. diameter of workingtable(mm)Ø116The Max. liftingdisplacement(mm)24Max. touch distance betweenpressure foot and workingtable(mm)0.05TH200FJ/210FJOPERATING STANDDimensions(mm) 420×200×170Weight(kg) 18 22


14Beijing TIME High Technology Ltd.www.timeinstrument.comTR100/110SURFACE ROUGHNESS TESTERStandard Delivery●Main unit 1●Specimen Ra 1●Charger 1●TIME certificate 1●Instruction manual 1●Warranty card 1Optional Accessories●Various Ra specimen withRa values: 0.1μm, 0.2μm,0.4μm, 0.8μm, 3.2μmFeatures●Pocket-size & economically price●Large measuring range suitable for most materials●Measures flat, outer cylinder and sloping surface●Both Ra and Rz parameters in one instrument●Features external calibration at keyboard●Standard conform to ISO and DIN●Rechargeable batteries, work while charging●TR110 is equipped with Li-ion battery and backlightTechnical SpecificationModel TR100 TR110Roughness parameterTracing lengthTracing speedCut-off lengthsEvaluation lengthMeasuring rangeRa, Rz6mm1.0mm/sec0.25mm/0.8mm/2.5mm1.25mm/4.0mm/5.0mmRa: 0.05-10.0μm Rz: 0.1-50μmAccuracy ±15%Repeatability


15Beijing TIME High Technology Ltd.www.timeinstrument.comTR200/220SURFACE ROUGHNESS TESTERStandard Delivery●Main unit 1●TS100 standard pickup 1●Specimen Ra 1●Protection nose 1●Steel support 1●Screwdriver 1●Communication cable 1●Instruction Manual 1●Software 1●TIME Certificate 1●Warranty card 1Optional Accessories●TS110 pickup for curved surface●TS120 pickup for small holes●TS130 pickup for deep grooves●TS140 right-angled pickup●Measuring platform TA610/TA620●Leveling table TA630/TA631●Magnetic stand●Steel adapter (Ø8)●Steel adapter (L-attachment)●Printer TA230Features●Applicable in production site, laboratory and workshop in factory●Easy operation menu and large LCD display with backlight●Li-ion rechargeable battery●Pickup position indicator●Conform to ISO standard, compatible with DIN, ANSI and JISstandard●Advanced software for TR200 and TR220 is available●Lots of delicate optional accessories are supplied making user’smeasurement more efficient and much easierTechnical SpecificationModel TR200 TR220Roughness parametersRa, Rz, Ry, Rq, Rt, Rp, Rmax, Rv,R3z, RS, RSm, RSk, Rmr,Ra, Rz, Ry, Rq, Rt, Rp, Rmax, Rv, R3z, RS, RSm,RSk, Rmr, Rpc, Rk, Rpk, Rvk, Mr1, Mr2Assessed profilesMeasuring systemDisplay resolutionData outputPickup measuring rangeCutoff length (L)Evaluation lengthTracing lengthDigital filterMax. tracing lengthMin. tracing lengthRoughness profile (R)Primary profile (P)Metric, imperial0.001 μ mRS232±20μ m, ±40μ m, ±80μ m0.25mm / 0.8mm / 2.5mm/Auto1~5L (selectable)(1~5)L+2L(selectable)RC, PC-RC, Gauss, D-P17.5mm/0.71inch1.3mm/0.051inchPick-up Standard pickup TS100, inductive, Diamond stylus radius 5μm, angle of stylus 90°Accuracy≤±10%Repeapility


17Beijing TIME High Technology Ltd.www.timeinstrument.comTIMESurf for TR200/TR220TIMESurf for TR200 and TR220 Software works with TIME surfaceroughness tester TR200 and TR220 for managing, analyzing, printing andsearching measured data and graphsMR CurveRK CurveDatabase managementOnline measurement


18Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Pickup●Specimen Ra 3.2●Screwdriver●Transducer supporter●Power adapter 9V/3A●Instruction manual●Warranty card●TIME certificate111111111Optional Accessories●Printer TA230●PC software (TIMESurf for TR300)●RS232 communication cableTechnical specificationFeatures●Equipped with 55 kinds of parameters that conformto ISO/DIN/ ANSI/JIS standards●Measurement of roughness, waveness andprimary profile with a wide measuring range●Integrated design for convenient using●LCD, digital/graphic display●Skidded / skidless pickup makes it so efficient toevaluate curved surface roughness●Equipped with advanced Windows software●Outputting of data to PC by using RS232 or USBcable is available as well as printing out by printerAssessed profileMeasuring RangeR (Roughness), W (Waveness), P(Primary profile)±400µm, ±25µmFiltering RC,PCRC,Gauss,D-P,ISO 13565ParametersCutoff lengthR: Ra,Rp,Rv,Rt,Rz,Rq,Rsk,Rku,Rc,RS,RSm,Rlo,RHSC,Rpc,Rmr(c),RzJIS,R3y,R3zW: Wa,Wp,Wv,Wt,Wz,Wq,Wsk,Wku,Wc,WS,WSm,Wlo,WHSC,Wpc,Wmr(c),WzJISP: Pa,Pp,Pv,Pt,Pz,Pq,Psk,Pku,Pc,PS,PSm,Plo,PHSC,Ppc,Pmr(c),PzJISRk: Rk,Rpk,Rvk,Mr1,Mr20.08mm,0.25mm,0.8mm,2.5mm,8mmMax. tracing length40mmAnalysis graphsADC, BACEvaluation length1L-5LResolution0.001μm/50μm;0.016μm/800μmTolerance ±5%DisplayLCDMemory10 groups of primary dataData outputRS232,USBTR300SURFACE FORM TESTERPower supply Li battery / AC adapterDimensions(mm) 409×96×98Weight(g) 2300


19Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Transducer 1●Power adapter 1●Protection sheath for main unit 1●Protection sheath for laser head 1●Software 1●Communication cable 1●TIME certificate 1●Warranty card 1●Instruction manual 1Technical SpecificationMeasuringparametersRaFeatures●Suitable for quality control process, the roughness ofall the workpiece must be checked●Fast measurement, display Ra values within onesecond on 3.2 inch LCD display●Non-contact roughness measurement and withoutscratch●On-line detection of Ra value●Precision machined workpiece, crankshaft andcamshaft surface inspections●Comparative method is applied to facilitate identifyingthe quality of workpiece●Principle: Light scatting, build relationship betweenthe light intensity and the roughness●With calibration software to rectify the measuredvalue●Communication with PC via RS232 interface, achieveata upload and parameters downloadMeasuring rangeErrorMeasured area10nm≤Ra≤1.0μm10nm≦Ra≦0.2μm ≦0.03μm0.2μm≦Ra≦1.0μm ≦10%1×3 mmRepeatability ≥90%DisplayPower supplyPower adapterStorage temperature -25℃~50℃OperatingtemperatureHumidityTFT color matrix liquid screenLi battery 4×3.6V 2200mAhInput100~240V 50HZ~60HZOutput 9V 2.5A0℃~40℃20%~75%RHDimensions (mm) 164×152×46Weightkg 1.1Fitting curveTRL400LASER ROUGHNESS TESTER


20Beijing TIME High Technology Ltd.www.timeinstrument.comMEASURING PLATFORMTA610TA630Specificaitons:X-axial range:±12.5mm;Y-axial range:±12.5mm;Rotation: coarse adjustment 360º, fineadjustment ±5º;Pitching: 0º ~ 5º.Specifications:Surface dimensions:400mm×250mm×70mmFeatures:Lifting the table through rack and the column canbe rotate, it is suitable for testing the workpiecewhich is not convenient to place for improveaccuracyY-axial range: 270mmTA631TA620Specifications:X-axial range:±12.5mm;Y-axial range:±12.5mm;Rotation: Coarse adjustment 360º, fineadjustment: ±5º.TA650Specifications:Dimensions: 400 mm×250 mm×70 mmY-axial range: 300mm±1mmFeatures:Elevating the table through screw, and V shapegroove is available, it is suitable for testing tinyworkpiece to improve the accuracySpecifications :Y-axial range: 300 ± 1 mmThe dimension of measuring platform: 600mm×420mm×80mmAdjusting range of leveling tableX-axial direction: ±12.5 mmY-axial direction: ±12.5 mmRotation: 360º; fine adjustment: ±5ºPitching: 0º ~ 5º


21Beijing TIME High Technology Ltd.www.timeinstrument.comTT210COATING THICKNESS GAUGEStandard Delivery●Main unit 1●Calibration foil set 1●Substrate 1●AAA 1.5V battery 2●Waist pack for main unit 1●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessories●Printer TA230●Connecting cable●Dataview softwareTechnical SpecificationFeatures●Two measuring methods: magnetic induction (F) and eddycurrent (N)●Magnetic induction (F) method is used to measure the thicknessof non-magnetic coating on ferrous metal●Eddy current (N) method is used to measure the thickness ofnon-conducting coating on non-ferrous materials●Automatic recognition of substrate●Automatic selection of measuring methods●5 statistical ways: Mean values / Max. values / Min. values /testing numbers.(No.) / standard deviations (S.DeV)●Upper-lower limit setting and sound alarm●Data output to printer TA220S or PC by RS232●500 readings can be stored●2 measuring modes: continuous / singleProbe types F NMeasuring methods magnetic induction eddy currentMeasuring range 0 ~1250 μm 0 ~1250 μm, 0 to 40μm (for chromeplate on copper)Minimum resolution0.1μmToleranceOne pointcalibrationTwo pointscalibrationMin. curvatureradius (mm)±(3%H+1)± (3%H+1.5)H means the thickness of tested piece±[(1~3)%H+1]±[(1~3)%H+1.5]H means the thickness of tested pieceConvexity 1.5 Convexity 3MeasuringconditionMin. testing areadiameter (mm)Ø7Ø5Critical thicknessof substrate0.5 0.3Power supplyWorking TemperatureBattery AAA 1.5V (2pcs)0~40°CDimensions(mm) 110×50×23Weight(g) 100


22Beijing TIME High Technology Ltd.www.timeinstrument.comTT211COATING THICKNESS GAUGEStandard Delivery●Main unit 1●Substrate 1●AAA 1.5V battery 2●Waist pack for main unit 1●Instruction manual 1●TIME certificate 1●Warranty card 1Features●Economical model with F probe integrated●Single point measurement mode●Easy calibration on zero point●3 kinds of adjustable resolution for different application●High speed data collection●Automatically switch off●Easy conversion between mm and inchTechnical SpecificationProbe typesFMeasuring methodsmagnetic inductionMeasuring range0 ~ 1250 μmMinimum resolution 1μm 5μm 10μmTolerance±(3%H+1) ± (3%H+1.5) ± (3%H+10)H means the thickness of tested pieceMin. curvature radius (mm) Convexity 1.5MeasuringconditionMin. testing area diameter (mm)Ø7Critical thickness of substrate 0.5Power supplyBattery AAA (2pcs)Working Temperature0~40°CDimensions(mm) 110×50×23Weight(g) 100


23Beijing TIME High Technology Ltd.www.timeinstrument.comTT230COATING THICKNESS GAUGEStandard Delivery●Main unit●Charger●Calibration foil set●Substrate●Pocket case●Instruction manual●TIME certificate●Warranty card11111111Optional Accessories●Printer TA230●Connecting cableFeatures●TT230: integrated probe N●2 measurement modes: continuous / single●5 statistical ways: Mean values / Max. values / Min.values / testing numbers.(No.) / standard deviations(S.DeV)●15 measurement readings stored●Low battery indication●Automatically switch off●Real time or batch printing with TA230 printerTechnical SpecificationProbe typesNMeasuring methodsMeasuring rangeMinimum resolutionEddy current0 ~1250 μm1μm (0.1μm when thickness is less than 10μm)ToleranceOne point calibrationTwo points calibration± (3%H+1.5)H means the thickness of tested piece±[(1~3)%H+1.5]H means the thickness of tested pieceMin. curvature radius (mm) Convexity 3MeasuringconditionMin. testing area diameter (mm)Ø5Critical thickness of substrate 0.3Power supplyWorking TemperatureRechargeable NiMH battery (2pcs)0~40°CDimensions(mm) 150×53×22Weight(g) 150


24Beijing TIME High Technology Ltd.www.timeinstrument.comTT270COATING THICKNESS GAUGEStandard Delivery●Main unit 1●Probe 1●Substrate 1●Calibration foil 1●Charger 1●Printing paper 1●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationMeasuring rangeProbe availableToleranceSee table in page26Minimum resolutionMeasuring conditionFeatures●Adopts two measuring methods:magnetism induction(F) and eddy current(N). When Fprobe is equipped, it can measure the non-magneticcoatings on magnetism substrate, when N probe isequipped, it can measure the non-conduction coatingon non-magnetism substrate●6 types of probes are available for various application:F400,F1,F1/90,F10,N1,CN02●Two measuring modes:continue/single●Two working modes: direct mode(DITECT) and Batchmode(APPL)●5 statistic ways:Mean values/Max.values/Min.values/<strong>Testing</strong> numbers(No.)/Standard deviations(S.Dev)●Two measuring calibration modes●With backlight display●640 measured values can be stored●Integrated with printer●Low battery indication●2 switch off modes: manual and autoStandardsDIN,ISO,ASTM,BSCalibrationZero and foil calibrationInterfaceRS232StatisticNumber of measurement, mean, standarddeviation, maximum and minimumData memory 640 readingsLimitsAdjustable with alarmPower supply NiMH rechargable batteryDimensions(mm) 230×86×47Temperature:0~40℃OperatingenvironmentHumidity:20%~90%No strong magnetic field


25Beijing TIME High Technology Ltd.www.timeinstrument.comTT290COATING THICKNESS GAUGEStandard Delivery●Main unit 1●Calibration foil set 1●Substrate 1●AAA1.5V battery 2●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessory●TA230 PrinterTechnical SpecificationProbe TypesFMeasuring methodsMagnetic inductionMeasuring range0~1250μmDisplay resolution0.1μmTolerance One point calibration ± (3%H+1)Two points calibration± [(1%~3%) H+1]MeasuringconditionMin.curvatureradius(mm)convexity 1.5Features●Integrated with F probe●Two working mode: direct and batch●500 measurement values can be stored●Five statistical values: mean value (MEAN), maximumvalue (MAX), minimum value (MIN), measurementtimes (NO.) and standard deviation (S.DEV)●Print-out function, capable of printing out measuredvalues and statistical values●Low battery indication●Buzzer prompt of operations●Error messages●With backlight●Shut off automatically or manuallyPower supplyMin.testing areadiameter(mm)Critical thicknessof substrate (mm)Ø70.5Working temperature 0~40℃Dimensions(mm) 145×60×27Rechargeable NiMH battery(2pcs)Weight (g) 150


26Beijing TIME High Technology Ltd.www.timeinstrument.comOptional Probes and Application GuideProbe model F400 F1 F1/90º F10 N1 CN02Operating principle Magnetic induction Eddy currentMeasuring range (µm) 0~400µm 0~1250µm 0~10000µm0 to 1250 μm0 to 40μm (forchromeplate oncopper)10~200µmLow range resolution (µm) 0.1 0.1 10 0.1 1AccuracyMeasuringconditionsOne-point calibration(µm)Two-point calibration(µm)Min curvature of themin area (mm)Diameter of the minarea (mm)Critical thickness ofsubstrate (mm)±(3%H+1) ±(3%H+10) ±(3%H+1.5) ±(3%H+1)±[(1~3)%H+0.7] ±[(1~3)%H+1] ±[(1~3)%H+10] ±[(1~3)%H+1.5] -Convex1 1.5 Flatten 10 3 FlattenØ3 Ø7 Ø7 Ø40 Ø5 Ø70.2 0.5 0.5 2 0.3 unlimitedApplication of two measuring methodsMagnetic induction (F)Coating: non-magnetic materialSubstrate (base): magnetic materialAny non-magnetic materials such as gold,copper, zinc, tin, lead, resin, rubber, glassand so on.Eddy current (N)Coating: non-conductorsSubstrate (base): non-magnetic metalsAny non-conductors such as painting,synthetic resin, rubber, glass and so onAny magnetic materials such iron, steel,cobalt and nickelAny non-magnetic metals such as brass,copper, aluminum and so on.Reference Table for Probe selectionSubstrateSteel,iron and other magnetismmetalCopper,Brass,Aluminum,Zinc,Tin and other metallicPlastic nonmetallic substrateCoatingsDiameterof tesitngarea ismore than30mmDiameterof testingare is lessthan 30mmDiameterof testingarea ismore than5mmDiameterof testingare is morethan 7mmNon-magnetism coatings (Organic materials)F1 probe:0~1250µmF400 probe:0~400µmF400 probe:0~400µmN1 probe:0~1250µmThickness of coatings is more than 100F1 probe:0~1250µmF10 probe:0~10µmF1 probe:0~1250µmF400 probe:0~400µmNon-magnetism coatings(nonferrous metals)F400probe:0~400 µmF1probe:0~1250µmF400 probe:0~400µmF1 probe:0~1250F10µm probe:0~10µmF400 probe:0~400µmF1 probe:0~1250µmN1 probe:0~40µm(For chromeplate on copper)- - CN02 Probe:10~200µm


27Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●5MHz transducer●Integrated steel calibration plate 4.0mm●Batteries AA1.5V●Couplant●TIME certificate●Warranty card●Instruction manual11121111Features●Portable size and easy operation●Suitable for any metallic and non-metallicmaterials ultrasonic can go through●Self-compensating of nonlinearity function issupplied for correction of pickup nonlineasity●Optional 2.5MHz,5MHz and 7MHz transducerare available●Large LCD screen display and auto shut down●Low battery indication●100 measured data can be stored●Measure the sound velocity when the thicknessis knownOptional Accessories●2.5MHz transducer(3~300mm)●7MHz transducer(0.75~60mm)Technical SpecificationMeasuring rangeDisplay resolutionSound speed0.8~225mm0.1mm1000~9999m/sWorkpiece temperature -10~60℃Display4 digital LCDMeasuring accuracy±(1%H+0.1)mmProbeØ6mm(optional) Ø10mm(Standard)Ø12mm(optional)Calibration plate4.0mm(Steel)PowerAA batteries 1.5V(2Pcs)TT150Working time250hoursDimensions(mm) 149×72×32ULTRASONIC THICKNESS GAUGEWeight(g)200 (with battery)


28Beijing TIME High Technology Ltd.www.timeinstrument.comTT100/110/120/130ULTRASONIC THICKNESS GAUGEStandard Delivery●Main unit 1●Integrated steel calibration plate 4.0mm 1●Warranty card 1●5MHz straight transducer (For TT100/110/120/130) 1●Batteries AA1.5V 2●Instruction manua 1●5MHz angle transducer (For TT100/110/130) 1●Couplant 1●ZW5P high temperature transducer (For TT120) 1●TIME certificate 1TT100 TT110 TT120 TT130Features●Portable size and easy operation●Suitable for any metallic and non-metallic materialsultrasonic can go through●Self-compensating of nonlinearity function is supplied forcorrection of pickup nonlineasity●10 measuring values recorded●Optional 2.5MHz, 5MHz and 7MHz transducers areavailable●5 pre-set sound velocities for repeating applications●TT100 and TT130 are suitable for thickness testing of variousmaterials with sound speed range 1000-9999m/s●TT100 and TT120 are easy-operation models with only two keyssuitable for thickness testing of steel●TT120:High-temperature model with range up to 300°C;easy-operation model with only two keys suitable for thicknesstesting of steelTT100 TT110 TT120 TT130Measuring range0.75 – 300.00mm (steel)(depends on probe)Measuring range for steelpipesMin.3.0mm thickness ×Ø20 diameterDiameter of transducer Ø10 (standard) Ø6 (optional) Ø12(optional)Display resolution 0.1mm 0.01mmCalibration4.0mm steel base plate integratedTolerance±(1%H+0.1) mm (H means the thickness of tested piece)Measuring units mm or mm/inch mm/inch mm/inch mm/inchSound velocity range 1000-9999m/s 5900 m/s 5900 m/s 1000-9999m/sDisplay4-Digital LCDSurface temperature -10℃ to +60℃ -10℃ to +300℃ -10℃ to +60℃Battery indicatorLow battery voltage indicatorPower supply 2 Pcs. AA batteries 1.5VOperation time250 hoursDimensionsWeight126mm×68mm×23mmApprox. 250g including batteries


29Beijing TIME High Technology Ltd.www.timeinstrument.comStandard deliveries●Main unit 1●Transducer 5PØ10 1●Transducer ZW5P for TT320 1●Transducer TSTU32 for TT340 1●Rubber jacket 1●Couplant 1●Batteries AA 1.5V 2●Screwdriver 1●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessories●Optional transducers (See page33)Technical SpecificationModel TT300A TT320 TT340Features●Advanced handheld ultrasonic thickness gauge●Suitable for most metallic and non-metallic materialsultrasonic can go through●Auto-calibration of zero point, correction of systemerror●Display current thickness or minimum thickness (menuselectable)●Upper-lower limits setting and sound alarm●Memory of 500 stored values●Two point calibration for high accuracy●Display resolution 0.1mm/0.01mm selectable●Display in mm or inch●Large LCD display with adjustable backlight●Low battery indicator●TT300A: Can be equipped with low frequencytransducer for thickness testing of thin workpiece andauto calibration is available●TT320: high-temperature model with range upto300℃●TT340: equipped with TSTU32 transducer for castingiron1.2mm-Measuring range0.75mm-225.0mm(steel)(Depends onprobe)225.0mm(steel)5.0mm-80.0mm (steel1.2mm-225.0mm(steel)high-temp)±0.5% H+0.01mm(H means theMeasuring±1% H +0.1mm (H means thethickness of testedaccuracythickness of tested piece)piece)Ø15mm×2.0mm(For 7MHztransducer)Lower limits ofØ20mm×3.0mmsteel pipes(For 5MHzØ20mm×3.0mmtransducer)Display0.01mm orresolution 0.001inch0. 1mm or 0.01inchData output RS232Sound velocity 1000m/s~9999m/sPower supply AA batteries (2pcs) 1.5VBattery life 100 hours without backlightSound speed1000m/s~9999m/sTT300A/320/340ULTRASONIC THICKNESS GAUGEUnit scales mm/inchDimensions(mm) 152×74×35Weight(g) 250 370Surfacetemperature-10℃~ +300℃ -10℃+300℃ -10℃+60℃


30Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Transducer 5PØ10●Couplant●Sheath for main unit●Instruction manual●TIME certificate●Warranty card1111111Optional Accessories●Transducer TSTU17●Transducer TSTU32Technical SpecificationFeatures●Echo to echo measurement is available, it is usedfor measuring the distance between echo to echo,so users can get the thickness of steel plate eventhough it is covered by coating●Advance and handheld ultrasonic thickness gauge●Transducer TSTU17 and TSTU32 are optional tomeasure various materials●Resolution 0.001mm and 0.01mm selectable●Upper and lower limit of thickness measuring isset to mind users●Memory: 500 readings●Review, edit and clean single readings and files●Data output to TIME TA230 printer or PC viaRS232 port●Automatic identify the standard transducerMeasuringrange(dependson probe)DisplayresolutionSound speedDisplayMeasuringaccuracyData outputTransducer 5PØ10: 1.2~225mm (steel inT-E testing mode) 3~20mm(steel in E-Emode)Transducer TSTU17: 0.6mm~50mm(steel inT-E testing mode)Transducer TSTU32:5mm~300mm(steel inT-E testing mode)0.001mm or 0.01mm1000~9999m/sBacklight±1%H+0.1mm(H means the thickness oftested plate)RS232Calibration plate4.0mm(steel)PowerAA batteries 1.5V (2Pcs)Measuring unitsmm/inchDimensions 152×74×35TT360ULTRASONIC THICKNESS GAUGEWeightSurfacetemperature220g-10~60℃


TT500ULTRASONIC THICKNESS GAUGE31Beijing TIME High Technology Ltd.www.timeinstrument.comTechnical SpecificationFeatures●A scan thickness measuring, easy for users to identify the measuring errors byanalyzing the waveform on screen●Function of echo-echo measurement is available. It is used for measuring thedistancebetween echo to echo, and thus users will get to know the thickness of steel plateeven though it is covered by coating, such as inspection of oil tanks●Min. and Max. mode function is supplied for users to find out the Min. (or Max.) valuefrom a group of measuring results. it is very useful for inspecting the wall thickness ofpipes and pressure vessels●D-value mode function. It comprises normal D-value mode and percentage D-valuesmode. It will enhance operator’s working efficiency greatly. Specially, users workingwith exact and changeless process requirements will benefit from TT500 immensely.●Large memory up to 100 A-scan images and 10000 thickness values●Manual gain adjustment / auto gain selectable●Up and low limits alarm is availableMeasuring rangeTechnical SpecificationSound speedScanning modeGain rangeRectification<strong>Testing</strong> mode0.75~508.00mm1000~9999m/sA scan20~70db step: 1dbPositive half wave, negative wave, full wave, and RFStandard mode: testing from primary pulse to the first echo<strong>Testing</strong> between two echoesResolution Standard: 0.01 low: 0.1MemoryCommunicationPrinter100 A scan graphs and 10000 thickness values in 100 groupsRS232 port to PC or printerTP UP-NH-S thermal printer1. when resolution is 0.01mm and thickness H < 10mm, the tolerance is ±0.05mmTolerance (steel)2. when resolution is 0.01mm and thickness H ≥ 10mm, the tolerance is ±(0.5%H+0.01mm)3. when resolution is 0. 1mm, the tolerance is ±((1%H+0.1mm)Low limits for steel pipesPulse frequencyWorking temperature1.Ø15mm×3.0mm display error is less than ±0.1mm(resolution =0.01mm, 7MHz transducer)2.Ø20mm×3.0mm display error is less than ±0.2mm(resolution =0. 1mm, 5MHz transducer)1KHz0°C~40°CDimensions(mm) 234×127×38Weight(Kg) 1


32Beijing TIME High Technology Ltd.www.timeinstrument.comUITRASONIC THICKNESS GAUGEStandard Delivery●Main unit 1●Transducer 15Pø6 1●Screwdriver 1●Protection sheath for main unit 1●Connecting protection sheath 1●Cover protection sheath 1●AA battery 1.5V 2●Couplant 1●Instruction manual 1●Warranty card 1●TIME certificate 1Optional Accessories●Communication cable●Standard test block●TA230 printerFeatures●Especially suitable for testing the thin workpieces●I-E testing mode and E-E testing mode●Sound velocity testing and single point calibration●Sound alarm and differential mode are available●mm/inch are selectable●Data store, view and delete●Result can be print out and transfer to PCTechnical SpecificationMeasuring range0.15~20mmDisplay resolution0.001 mm and 0.01 mm selectableSound velocity range1000m/s~9999m/sOperating temperature 0~40℃Dimension(mm) 152× 74× 35TT700Weight(g) 220ULTRASONIC THICKNESS GAUGEPower supplyAA batteries 1.5V(2 Pcs)


33Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●5PØ10/90° transducer 1●Batteries AA 1.5V 2●Couplant 1●Time certificate 1●Warranty card 1●Instruction manual 1●Carrying case 1Optional Accessories●Optional transducers(next Page)Technical SpecificationMeasurement range0.75mm~508mmFeatures● With function of echo-echo (E-E) measurement andauto gain control (AGC),users will get to know thethickness of substrate , even though it is coveredbycoating●Difference mode and velocities setting●Vibration alarm and sound & light alarm settings●Velocities calibration and zero calibration●Measurement units inch, mm and microsecond●Measurement results holding●Easy operating keypad by left/right switch●High frequency scanning technique available●Superior waterproof and dustproof plastic shellVelocity range508~18699m/sMeasurement rate 4/s and 20/s in fast modeBandwidth0.5MHz~20MHz (-3dB)Resolution 0.01mm(0.001〞), 0.1mm (0.01〞)Velocity calibrationrange0.508mm/μs~18.699mm/μs(0.0200 in/μs -0.7362in/μs)Display128×64 Graphics LCD monochromeBattery lifeUp to 200 hours (40 hours withbacklight on)Operating temperature-20℃~+50℃TT900ULTRASONIC THICKNESS GAUGEMeasuringtemperature-20℃~+500℃(according to theprobes)Dimensions(mm) 127×76×32Weight(kg) 0.23


Optional Transducers34Beijing TIME High Technology Ltd.www.timeinstrument.com5PØ10 for TT1 series,TT3 series and TT9005PØ10/90° forTT1 series5PØ10/90° forTT3 series7PØ6 for TT1 seriesTT300A and TT900SZ2.5P for TT1 seriesZW5P for TT120, TT300A,TT320 and TT9005PØ 10 for TT500 TSTU32 for TT340 5PØ10/90° for7PØ6 for TT500 TSTU32 for TT500TT500and TT9005PØ10 Straight 1.2~225.0mm(steel) 10mm 5MHz -10℃~+60℃5PØ10/90° Angle 1.2~225.0mm(steel) 10mm 5MHz -10℃~+60℃7PØ6Small diameter0.75~60mmØ15×2.0mm(steel)6mm 7MHz -10℃~+60℃DHT537 High-temperature 1.0~508.0mm(steel) 10mm 5MHz -20℃~+500℃ZW5P High-temperature 5.0~80.0mm(steel) 12mm 5MHz -10℃~+300℃TSTU32 High penetration 5.0~40.0mm(cast iron) 22mm 2MHz -10℃~+60℃Guideline to standard velocity in materialsMetals (m/s)Aluminum 6320 Gold 3240 Nickel 5630 Tin 3230Brass 4640 Inconel 5720 Platinum 3960 Titanium 6070Cast iron 4500 Iron 5900 Sliver 3600 Tungsten carbon 5650Copper 4700 Lead 2200 Steel,mild 5900 Tungsten 5400Cadmium 2800 Manganese 4700 Steel,low carbon 5850 Zina 4170Chromium 6200 Magnesium 6310 Steel,stainless 5790 Zirconium 4650Non-metals (m/s)Acrylic Resin 2730 Ice 3980 Polyamide 2380 Rubber(butyI) 1900Aluminum 8700 Neoprene 1600 Polyethylene 1900 Rubber(soft) 1450Ceramic 5631 Nylon 2620 Polyurethane 1900 Rubber(vuic.) 2300Diamond 17500 Paraffin 2200 Polystyrene 2400 Silicone rubber 948Epoxy resin 2650 Perspex 2850 Porcelain 5600 Teflon 1350Glass 5440 Plexi glass 2700 PVC 2400 Water(20℃) 1480


35Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Accelerometer probe 1●Magnetic base 1●Charger 1●TIME certificate 1●Instruction manual 1●Warranty card 1Optional Accessories●Needle groupware●Short needleTechnical SpecificationsFeatures●Fast failure detecting of motor, electric fan, pump,air compressor, machine tools and so onAcceleration0.1m/s 2 – 199.9 m/s 2 (peakvalue)●Analysis of acceleration, velocity, and displacement●Large memory of 100 results and 10 frequencyspectrograms●Hand-held accelerometer probe is available with<strong>Testing</strong> rangeVelocity0.01cm/s – 19.99cm/s (virtualvalue)a removable magnetic base for connecting withtested parts●Low battery indicationDisplacement0.001mm – 1.999mm (peak topeak value)●Rechargeable battery●Large LCD display●Printer integrated, readings and vibration patterncan be printed outAcceleration10Hz – 500Hz, 10Hz – 1KHz,10Hz – 10KHz●Upper and lower limit setting and sound alarmFrequency rangeVelocity10Hz – 500Hz, 10Hz – 1KHzDisplacement10Hz – 500HzPowerNickel-hydrogen batteryTolerance ±5%Workingtemperature0°C~ 40°CTV110VIBRATION TESTERDimensions(mm) 270×86×47Weight(g) 650


36Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Battery 2●Protection pocket 1●TIME certificate 1●Instruction manual 1●Warranty card 1Features●Used for fast failure detecting of motor, electricfan, pump, air compressor, machine tools andso on●Compact size, small weight, easy handling●Prompt testing of vibration on the workshopmachines●For quick checking of unbalance misalignment,bearings and gears●Guard against mechanical malfunction●Holding tested value for 40 seconds●Automatic switch off after 40 seconds●TV260A is used for testing of acceleration,velocity and displacementTechnical SpecificationModel TV200 TV260AParameters<strong>Testing</strong>rangeFrequencyrangeRMS ofvibrationvelocity (mm/s)Velocity:0.1mm/s~199.9mm/sVelocity:10Hz ~ 1kHzAcceleration, Velocity, DisplacementAcceleration:0.01m/S 2 -199.9m/S 2 (peak)Velocity: 0.01mm/s-199.9 mm/s(RMS)Displacement:0.001mm-1.999 mm (peak-peak)Acceleration: 10Hz ~ 1kHzVelocity: 10Hz ~ 1kHzDisplacement:10Hz ~ 500HzAccuracy ±5%Display3 1 / 2 digits LCDPowersupplytwo button batteries(LR44 or SR44)BatterycapacityApprox. 4.5 hours working continuouslyOperatingTemperature0℃ ~ 40℃TV200/260AVIBRATION PENHumidityDimensionWeight


37Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Protection pocket 1●Low sensitivity probe(only for TV310) 1●High sensitivity probe( only for TV320) 1●Power adapter 1●Magnetic base 1●Instruction manual 1●TIME certificate 1● Warranty card 1Optional Accessory●Needle groupware●TA230 printer●RS232 communication cableFeatures●TV310 is equipped with low sensitivity probe,suitable for testing strong vibration signal.●TV320 is equipped with high sensitivity probe,suitable for testing weak vibration signal.●Two display modes: digital value mode andspectrum mode●Large memory function:100×100 measuredresults(100 testing points, 100 data can bestored in each testing points ); 100 Spectralchart●Spectrum chart can display in real time●Easy diagnosis: alarm is sounded whenvibration go over limit set ,and get intospectrum mode●<strong>Testing</strong> results and spectrum chart can beprinted out when connected to printer●300×200 matrix LCD display, with backlight●<strong>Testing</strong> result of TV310/320 is more accurateand stable especially in low frequencyTechnical SpecificationModel TV310 TV320MeasuringrangeFrequencyrangeAcceleration 1m/s~392 2 2m/s (Peak) 0.1m/s 2 ~20 m/s 2(Peak)Velocity 0.1cm/s~80cm/s(RMS) 0.01cm/s~4cm/s(RMS)DisplacementAccelerationVelocityDisplacement0.01mm~18.1mm(Peak-Peak)0.001mm~0.8mm(Peak-Peak)10Hz~200Hz、10Hz~500Hz、10Hz~1KHz、10Hz~10KHz10Hz~200Hz、10Hz~500Hz、10Hz~1KHz10Hz~500HzAccuracy ±5%Temperature 0℃~40℃TV310/320VIBRATION TESTERRelativehumidityDimensionPower≤80%171× 78.5×28 (mm)Li battery (continuous working 20 hours)


38Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Remote switch 1●Mount base 1●TIME certificate 1●Instruction manual 1●Warranty card 1Features●Multi-parameter vibration, bearing parameter(acceleration envelope) & IR temperaturemeasuring●One button controls power, parameter selection,ISO 10816 group selection, measurement andholding●With remote switch and magnet base to avoidhandheld problem to get reliable and consistentdata●Measuring vibration velocity, displacement& Acceleration envelope to check machine/bearing health with yellow/red/green LEDindicator●Build-in ISO 10816-2 & 3 groups selectable,with 4 LCD digital display and automatic poweroff and sensor built-inTechnical Specification<strong>Testing</strong> Range Acceleration Velocity DisplacementEnvelopedAccelerationParameters 0.1~100 m/s 2 0.1~250 mm/s 1~3000 µm 0.1~25 unitsFrequencyRange10Hz~3kHzpeak10Hz~1kHzRMS10Hz~500Hzpeak-peak5Hz~2kHzdemodulatedfrom3kHz~10kHzTolerance+ 5% + 2 digitsPower Supply1/2 AA, 3.6V, 20-29mABatteryCapacityAbove 100 hours of continuous operationOperatingtemperature-33℃~220℃ / -27.4~428 FPickupIntegrated accelerometer with extension stinger and magnetbaseTIME35270MUITI-PARAMETER MACHINE CONDITIONCHECKERDimensions(mm)Weight(g)110×35×17100 (including battery)


39Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Protection pocket 1●Probe 1●Power adapter 1●Magnetic base 1●Instruction manual 1●TIME certificate 1●Warranty card 1Features●Data collector, easy to use● 2-channel sampling & displaying simultaneously●On-site 400-lines FFT spectrum and waveformdisplay with transfer function analysis● Data storage: 62*1024-point time waveformsand 240 data sets●Acceleration envelope demodulation for rollingbearing and gear-box diagnosis● On-site spectrum comparison function, withselectable inner or external trigger● Full featured 1 and 2 planes field balancing(10 sets balancing data storage; balancingprocess clarified by vector graph; trial weightestimation and can remove or remain trial afterbalancing; balancing weight decomposition)● Balancing report generated automaticallyOptional Accessory●Needle groupware●TA230 printer●RS232 communication cableTechnical SpecificationModelFrequency rangeAcceleration(m/s 2 )Velocity(mm/s)Acceleration: 10Hz~10000HzVelocity: 10Hz~1000HzDisplacement: 10Hz~500HzDisplacement(μm)Rotation Speed180~24000r/minError ±5%BatteryNi-MH rechargeable battery for 8 hourscontinuous operationOperatingtemperature0℃~50℃TIME35430HumidityDimensions(mm)90% humidity no condensing210×130×40mm2-CHANNEL VIBRATION METERWeight(g) 1200


40Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures●Horizontal protrudent nose design, testing onsurfaces difficult to reach●<strong>Testing</strong> internal surface of ring parts whosediameter is not less than 23mm (0.900")● <strong>Testing</strong> external surface of round bars whosediameter is not less than 3mm (0.120")● Automatic test process● High definition backlight LCD● Simple and easy selectable operation menu● RS-232/USB data output● TH300: Rockwell hardness tester● TH320: Rockwell & Rockwell superficialhardness testerTypical application● Researching institute● National organization● University● Aeration and space industry● Automobile industry● Steel industryProtrudent design for testing in place difficult to reachTH300/320ROCKWELL HARDNESS TESTERAssistant joistAssistant supportAssistant joist and Assistant support as shown below are designedto provide support for hardness testing of long, heavy and big workpieces.


TH300/32041Beijing TIME High Technology Ltd.www.timeinstrument.comROCKWELL HARDNESS TESTERTechnical SpecificationModel TH300 TH320HardnessscalesRockwell A, B, C,D,E,F,G, H, K ,L, M ,P, R, S, VRockwell A,B,C,D,E,F,G,H,K,L,M,P,R,S,VRockwell superficial15/30/45N,T,W,X,YResolution0.1Rockwell unitPre-load 98.07N/10kgf 98.07N/10kgf, 29.42N/3kgfTotal load588.4N/60kgf, 980.7N/100kgf, 1471N/150kgf588.4N/60kgf, 980.7N/100kgf,1471N/150kgf, 147.1N/15kgf,294.2N/30kgf, 441.3N/45kgfDisplayMatrix backlight LCDLanguage English, French, Germany EnglishOperationMenu selectable, Membrane keypadTest processAutomaticLoad duration2-50 seconds, can be set,dynamic displayed and storedFunctions• Upper / lower hardness limits setting and alarming• Data statistics : Ave., Max., Min., standard Deviation,• Convert tested values to HB, HV, HLD and δ b(Tensile-strength)• Curvature correction: cylinder and sphere surface• Upper / lower hardness limits setting and alarming• Data statistics : Ave., Max., Min., standard Deviation,• convert tested values to HB, HV, HLD and δ b (Tensilestrength)• Curvature correction: cylinder and sphere surfaceData outputRS232TesterstandardISO6508.2 , ASTM E-18<strong>Testing</strong> spaceVertical: 250mm (9.85〃)Horizontal:150mm (5.91〃)Vertical: 250mm (8.66〃) Horizontal:150mm (6.00〃)Work piecesizeExternal surface cylinder: Min.Ø3mm (0.120〃)Internal surface cylinder: Min.Ø23mm (0.900〃)Power supply220v/110v, 50Hz, 4ADimensions 715mm×225mm×790mm 720mm×240mm×815mmWeight 100kg 120kg


42Beijing TIME High Technology Ltd.www.timeinstrument.comLarge Vee anvilShort diamond indenterSlim diamond indenterFlat diamond indenterPoint/Vee anvilFlat/Vee anvil Round flat anvil Ø70 Round flat anvil Ø225Round flat anvil Ø150Standard DeliveryTH300TH320Main UnitMain unitTest Block BTest Block A, B, CTest Block CTest Block 15N120° cone diamond indenter Test Block 30N1/16" (1.5875mm) ball indenter Test Block 30T1/16" (1.5875mm) spare ball 120° cone diamond indenterScrew for indenter1/16"(1.5875mm)ball indenterRound flat anvilØ701/16" (1.5875mm) spare ballLarge Vee anvilScrew for indenterPower supply cableRound flat anvilOptional Accessories●Mini-printer TA230●Data communicating cable●Short diamond indenter●Flat diamond indenter●Slim diamond indenter●1/8"(Ø3.175mm) indenter and spare ball●1/4"(Ø6.350mm) indenter and spare ball●1/2"(Ø12.70mm) indenter and spare ball●Round flat anvil Ø225●Round flat anvil Ø150●Small Vee anvil●Flat /Vee anvil●Assistant support●Assistant joistInstruction manualWarranty cardLarge Vee anvilPower supply cableInstruction manualWarranty card


43Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery● Main unit 1●1/16"Ф(1.5875mm) ball indenter 1●Big <strong>Testing</strong> Table 1●Middle-sized <strong>Testing</strong> Table 1●V-shaped <strong>Testing</strong> Table 1●High & Low HRC2 blocks in all●HRB Blocks 1●Sets of weights A、B、C3 sets in all●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationPre-load98.1N (10kgf)Features●Measuring the Rockwell hardness of ferrous andnon-ferrous metals such as hard alloy, carbon steel,alloy steel, cast iron●Applied in the factories, scientific research institutesand laboratories of colleges etc.●Fresh design, easy to use, stable display value,convenient maintenance●Standards conforming to: BSEN10109-96,ISO6508.2Total loadRockwell scales<strong>Testing</strong> range<strong>Testing</strong> resolution588.4N (60kgf), 980.7N (100kgf),1471N (150kgf)HRA,HRB,HRC20~80HRA, 20 ~ 100HRB, 20 ~ 70HRC0.5HR Rockwell unitVertical testing spaceMax.175 mmHorizontal testingspaceMax.165mmTH500ROCKWELL HARDNESS TESTERDimensions(mm) 520×215×700Net weight(Kg) 78


44Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Test block A 1●Test block B 1●Test block C 1●1/16’’(Ø1.5875mm) ball indenter 1●1/16’’(Ø1.5875mm) spare ball 3●120ºcone diamond indenter 1●Screw for indenter 1●Ø60mm flat anvil 1●Ø60mm V-shape anvil 1●Ground bolt 4●Weight 3●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessories●Ø70mm flat anvil●Ø80mm flat anvil●Ø120mm flat anvil●Ø150mm flat anvil●Ø70mm Vee anvil●Ø80mm Vee anvil●Small Vee/point anvil●Other test blocksTechnical SpecificationFeatures● Operating Rockwell hardness testing of hardalloy,carbon steel, alloy steel and non ferrousmetal●High digital display resolution●Easy operation with auto loading and unloadingof test force, and auto holding of test force●Standards: BS EN ISO 6508, ISO 6598.2 andASTM E18Pre-loadTotal loadRockwell Scales<strong>Testing</strong> resolutionWorking method98.1N (10kgf)588.4N (60kgf), 980.7N (100kgf), 1471N(150kgf)1~100HRA, 0~130 HRB, 0~100HRC0.1Rockwell unitAuto loading of main test force, autohold and digital display of resultsVertical testing space200mm(7.87")TH550ROCKWELL HARDNESS TESTERHorizontal spacebetween indenter axis 160mm(6.30")and front wallDimension(mm) 580×270×740Weight(Kg) 105


45Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Test block 1●20× microscope 1●Ø10mm hard alloy ball indenter 1●Ø120mm round flat anvil 1●Vee anvil 1●Power supply cable 1●Weight 7●Ground bolt 4●Instruction manual 1●TIME certificate 1●Warranty card 1Features● Measuring the Brinell hardness of unquenched steels,cast iron, non-ferrous metals and soft bearing-alloysetc● High testing precision, extensive testing range,automatic load system● High accuracy, wide measuring range● Automatic force loading● Standards conforming to: ASTM E-10, ISO6506.2Optional Accessories●Ø2.5mm hard alloy ball●Ø5mm hard alloy ball●Ø10mm hard alloy ball●Ø60mm anvil●Ø70mm anvil●Ø150mm anvil●Ø2.5mm hard alloy ball indenter●Ø5mm hard alloy ball indenter●Ø80mm round flat anvil●Other test blocksTechnical SpecificationsTest forceIndenter ball diameter1839N (187.5kgf), 2452N (250kgf),7355N (750kgf),9807N (1000kgf),29420N (3000kgf)2.5mm, 5mm and 10mmTest force dwell time6~99s adjustable<strong>Testing</strong> range8~650HBWVertical testing space Max.230mm (9")Horizontal testing space Max.120mm (4.7")TH600BRINELL HARDNESS TESTERPower supply220V/110V, 50~60Hz, 2ANet weight(Kg) 218Dimensions(mm) Max.730×230×890


46Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Weights 6●Cross testing table 1●Platelet fixture 1●Plane-holding fixture 1●Filament fixture 1●Screw driver 2●Horizontal regulation screw 4●Level 1●Power cord 1●10× numerical microscope 1●Vickers hardness block 2●Repair fuses (1A) 2●Weight shaft 1●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessories●Knoop indenter●LCD device●Grinding machine●Cutting machine●Mosaic machineTechnical SpecificationFeatures●New high-tech product integrating mechanicaland photoelectrical technologies●Equipped with a digital microscope, direct displayof the measuring method, test force, indentationlength, hardness value, dwell time of test force●Camera device can be connected via RS232interface●Especially suitable for testing the hardness ofmicro and thin specimen, fragile material●By means of a 10× objective and a 40×objective, the tester has wide measurement andhigh accuracy●Optional Knoop indenter can be used to measureKnoop hardness value●TH711:Equipped with auto turret for antimaloperationTest ForcesCarriage ControlAmplification of theMicroscopeDwell Time of the TestForceMin. Graduation Valueof the <strong>Testing</strong> DrumWheel<strong>Testing</strong> FieldDimension of the XYTable(mm)Movement Field of theXY Table(mm)Max. height of thespecimen(mm)(0.098, 0.246, 0.49, 0.98, 1.96, 2.94,4.90, 9.80) N(10, 25, 50, 100, 200, 300,500, 1000) gfLoading / dwell/ unloading(automatic)100 ×, 400 ×(5-60)s0.0625μm1HV—2967HV100 × 10025 × 2570TH710/711Max. width of thespecimen(mm)Light source95Cold light sourceDIGITAL MICRO VICKERS HARDNESSTESTERPower Supply110V/220V,60/50HzDimensions(mm) 425 × 245 × 490


47Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Weights 6●Cross testing table 1●Platelet fixture 1●Plane-holding fixture 1●Filament fixture 1●Screw drivers 2●Horizontal regulation screws 4●Level 1●Power cord 1●10×numerical microscope 1●Vickers hardness blocks 2●Repair fuses (1A) 1●Cable for RS232 interface 1●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessories●Knoop indenter●Grinding machine●Cutting machine●Mosaic machine●LCD deviceTechnical SpecificationsFeatures●Large LCD screen to display the measuring method,test force, indentation length, hardness value, dwelltime of test force.●The hardness tester can be equipped with LCD device(composed of CCD measuring device and LCD displayscreen)●Especially suitable for testing the hardness of micro andthin specimen, fragile material●The tester has wide measurement and high accuracyby means of a 10× objective and 40×objective●Optional Knoop indenter can be used to measureKnoop hardness value●Print out testing results through built-in printer●TH715: Equipped with auto turret for anti-maloperationTest ForcesCarriage Control:automaticAmplification of theMicroscopeDwell Time of the TestForceMin. Graduation Valueof the <strong>Testing</strong> DrumWheel<strong>Testing</strong> FieldDimensions of the XYTable(mm)Movement Field of theXY Table(mm)Max. height of thespecimen(mm)Max. width of thespecimen(mm)(0.098, 0.246, 0.49, 0.98, 1.96, 2.94,4.90, 9.80) N(10, 25, 50, 100, 200, 300,500, 1000) gfLoading / dwell/ unloading(automatic)100 ×, 400 ×(5-60)s0.0625μm1HV—2967HV100 × 10025 × 257095Light sourceCold light sourceTH714/715DIGITAL MICRO VICKERS HARDNESSTESTERPower Supply110V/220V,60/50HzDimension(mm) 425 × 245 × 490Net Weight(kg) 35kg


48Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Largest test table 1●V shape test table 1●Screw drivers 2●Horizontal regulation screws 4●Level 1●Power cord 1●10×digital micro lens 1●Vickers hardness blocks 2●Repair fuse(1A) 2●Instruction manual 1●TIME certificate 1●Warranty card 1Optional Accessories●CCD measuring device●Knoop indenter(for TH720)Technical SpecificationType TH720 TH721<strong>Testing</strong>forceN4.903,9.807,19.61, 24.52,29.42,49.03,98.07,196.1,294.29.807,19.61,24.52,29.42,49.03,98.07,196.1,294.2,490.3Features●New high-tech product integrating mechanicaland photoelectrical technologies●Equipped with a digital microscope, direct displayof the measuring method, test force, indentationlength, hardness value, dwell time of test force●Camera device can be connected via RS232interface●Especially suitable for testing the hardness ofmicro and thin specimen, fragile material●Optional Knoop indenter can be used to measureKnoop hardness value●By means of closed-circuit system for control,CPU control testing force to load; dwell andunload, the sensor feedback information,therefore the lost of the testing force can beautomatically compensated during testing forhigh accuracyTH720/721DIGITAL VICKERS HARDNESS TESTERCarriage ControlDwell TimeKGFAmplification of themicroscopeMin. graduation value ofthe test drum wheel<strong>Testing</strong> fieldLens/Indenter switchMax. Height of thespecimenMax. Width specimenLight sourcePower0.5,1,2,2.5,3,5,10,20,301,2,2.5,3,5,10,20,30,50Loading/dwell /unloading(automatic)(0~60)s100×、400× 100×、200×0.0625μm1HV~2967HVwith Hand Turret170mm130mmCold light source110V/220V,60/50HZ0.125μmDimensions(mm) 535×225×580


49Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures● Suitable for testing the hardness of ferrous, non-ferrousmetals, hard metals, carburized layers and chemicaltreating layers● Multiple testing method: Brinell & Rockwell & Vickers● Different kinds of testing force and indenter can beselected● Adopt test force transformation framework and opticalmeasuring instruction system● Equipped with indentation measuring deviceStandard Delivery●Diamond Rockwell indenter●Diamond Vickers indenter●1.5875mm ball indenter●2.5mm ball indenter●5mm ball indenter●<strong>Testing</strong> table (Big, Small, “V”)●Standard Rockwell hardness block (55~65HRC)●Standard Rockwell hardness block(25~35HRC)●Standard Rockwell hardness block(HRB)●Standard Brinell Hardness block●Standard Vickers Hardness block●Weight 1●Weight 2●Weight 3●Weight 4●Weight 0#●15× Micrometer eyepiece●2.5×Objective●5×Objective●Power cord●Fuse●Lamp 6V,21CP●Lamp 6V,15W●Baffle testing table●Inner lamp head●Instruction manual●TIME Certificate●Warranty cardTechnical SpecificationsPre- test force(N) 98Rockwell test force(N) 588,980,1471Brinell test force (N) 306,613,18391111111111111111111111111111Vickers test force(N) 294,588,980Magnification ofmicroscopeMax. height ofspecimens(mm)37.5×,75×180TH722UNIVERSAL HARDNESS TESTERDistance fromIndenter's center to 200Outer Wall(mm)Machine Size(D×W×H)(mm)560×260×760Power supplyAC220V/50HzWeght(kg) 90


50Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Power adaptor 1●Neck strap 1●Cable for probe 2●Straight probe(2.5MHz,Ø20) 1●Angle probe(5MHz,8×9K2) 1●Couplant 1●Flash disk 1●Screw driver 1●TIME certificate 1●Warranty card 1●Instruction manual 1●Warranty card 1Optional Accessory●Connecting Cable●Dataview software for TUD310●Various probes●EPSON ink-jet printerTechnical SpecificationFeatures●Two measuring unit: mm/inch●Four Rectify Ways: positive half-wave, negative halfwave,full wave and radio frequency●Two scanning mode: A and B●Gate alarming function●32 detecting channels are available with a separatedetecting parameter and DAC curve in every channel●Automatic generation of DAC curve, and 30 points canbe recorded at most, adjustable offset curves and gaincorrection functions are available●Three detecting modes: single-probe , dual-probe andtransmission●Equipped with high-speed USB port and flash memorydevice can be used directly on the instrument●Data and documents are managed under FAT filesystem, making the management of inspection datamore convenient, faster and more reliant●Super large memory up to 32M, 1000 echo data can bestored in 32 detecting channels●Brand new digital signal circuit is designed for TUD310,Digital signal processor (DSP) is used for signalsanalyzing, making circuit noise reduced properly andwaveform more stable●EPSON ink-jet printers can be connected with TUD310by USB cable●Real-time waveform display and reviewScanning RangeScanning ResolutionGain RangeD-DelayP-DelaySound speedBandwidthVertical linearity error ≤3%Horizontal linearityerrorDynamic rangeRectificationSensitivity leavingsTest modePulserDampingRejectUnitInterfacePrinter2.5 mm ~9999 mm0.1mm (2.5mm ~100mm)1mm (100 mm ~5000mm)0dB ~110 dB-20µs~+3400µs0µs~99.99µs,resolution 0.01µs1000 m/s~9999m/s0.2MHz~15MHz (Low0.2~1 Mid.0.5~4High 2~10)≤0.2%≥32dBPositive half wave, negative wave, fullwave, and RF≥60dBPulse-echo, dual and throughtransmissionSpike excitation pulser50ohms, 150ohms and 400ohmsLinear, 0-80% of full screen, variable insteps of 1%Metric/inchRS232 / USBEPSON ink-jet printersAC requirements85-264V AC/1.0A,47-63HzTemperature -10℃~40℃TUD310ULTRASONIC FLAW DETECTORHumidity20%~90%RHPower supplyLi battery4×3.6V 4000mAhCharging time4~5hoursWeight1.47kgOverall dimension(mm) 243×173×70


51Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Mainunit●Couplant●Power adapter●Power cable for power adapter●Neck strap●Connecting cable●Straight probe(2.5MHz, 20)●Angle Probe(5MHz,8×9K2)●Flash disk●Instruction manual●TIME certificate●Warranty card111112111111Optional Accessory●Connecting cable●Dataview software●EPSON ink-jet printer●Various probesFeatures●Sampling frequency reach up to 160MHz●Color TFT LCD display●Memory up to 1024 A scanned images, parametersand 64000 thickness values●32 detecting channels are available with separateddetecting parameters and DAC curve in everychannel●Equipped with gate setting and alarming function●Two scanning modes: A scan and B scan●Auto gain and manual B scanning●USB 1.1,fullspeed communication port available●Can be connected with PC to print out result●Pulser voltage adjustable●Two measuring unit: mm/inch●Three detecting modes: single-probe, dual-probeand transmission●Real time waveform display and review●Four rectify ways: positive half-wave, negative halfway,full wave and radio frequencyTechnical SpecificationScanning RangeFrequencyGain RangeVertical linearity error ≤3%Horizontal linearityerrorDynamic RangeRectificationSensitivity leavingsD-DelayP-DelayScanning ResolutionSound Velocity2.5mm~9999mm0.1MHz~25MHz0dB~110dB≤0.2%≥34dBPositive half wave, negative wave, fullwave, and RF≥60dB-20μs ~3400μs0μm ~99.99μm0.1mm(2.5mm~99.99mm):1mm(100mm~9999mm)1000m/s~9999m/sOverall dimension243mm×173 mm×85mmWeightTest modeDamping1500gPulse-echo, dual and throughtransmission50ohms,100 ohms ,150 ohmsUnitmm/inchTUD360InterfaceRS232/USBPrinterEPSON ink-jet printerTemperature -10~40℃ULTRASONIC FLAW DETECTORPower supplyHumidityLi battery 4×3.6V20%~90%RH


52Beijing TIME High Technology Ltd.www.timeinstrument.comThis program is used to display measurement data andgraph in real time, edit and store data, prepare flawdetection report and print etc.Inspection reportWave dataTUD310/360SOFTWARE AND PROBESSetting parameters


53Beijing TIME High Technology Ltd.www.timeinstrument.comTechnical SpecificationTUD500 Technical SpecificationWeight(kg) 8 h


54Beijing TIME High Technology Ltd.www.timeinstrument.comSampling frequency(MHz) 80Crosstalk rejection(dB) >80Dead zone(μs)3.3~10(related with transmitting)Dynamic range(dB) 100Instant resolution(dB) 32Time base linearity


55Beijing TIME High Technology Ltd.www.timeinstrument.comTechnical SpecificationModel TI130 TI200 TI210TI130Measuringrange-20~530℃ -20~700℃ -20~1100℃Accuracy±2% or±2℃Repeativity±1% or±1℃ get the greaterDisplayresolution0.1℃ or 0.1FTI200TI210Opticalresolution12:1 30:1Features●Fast and reliable non-contact temperature measurement●Temperature range from -20℃ to 1100℃(see table below)●℃/℉ selectable●Adjustable emissivity, backlightSpectralresponse5~14μmEmissivity 0.95 fixed 0.01~1.0 adjustableSightingmodeLaser●Tolerance alarm●Display of Max., Min., △T, Avg. and real time value●Display hold, wide applicationResponsetimeTemperaturedisplay≤400ms℃/℉ electableBacklight√Display hold√Low and hightemperaturedisplay√Worktemperature0℃~50℃(32℉~122℉)Relativehumidity10%~90%RH noncondensing up to 40℃(104℉)TI130/200/210INFRARED THERMOMETERStoragetemperaturePowerDimensions(mm)-20℃~+50℃9V170×120×42Weight(g) 200


56Beijing TIME High Technology Ltd.www.timeinstrument.comTechnical SpecificationModel TI213EL TI315 TI315EMeasure range -25℃~1200℃ 400℃~1800℃ 500℃~3000℃TI213ELAccuracyRepetitive accuracy±1% or ±1℃ whichever is greater±0.5% or ±0.5℃get the greaterDisplay resolution 0.1℃ or 0.1℉Display4 digital LCDTI315Response timeLess than 200msSpectral response 8~14μM 2.1-2.4μMEmissivity 0.15-1.00 0.10-1.00Optical resolution(D: S)80:1 120:1Sighting mode Coaxis laser TelescopeMIN/AVE/ΔT √ √ √MAX √ √ √Features●Fast and reliable non-contact temperature measurement●Temperature range from -25 to 3000(see table below)/ selectable●Various sighting modes: coaxial laser, telescope●Adjustable emissivity, backlight●Tolerance alarm●Display of Max., Min.,△T, Avg. and real time value●Display hold, wide applicationDisplay holding √ √ √Low battery symbol √ √ √High/low alarm √ √ √Put out / / 1mV/℃Working voltage 6F22 9V batterySurroundingtemperature-18℃~+50℃-10℃~+50℃TI213EL/315/315ESurroundinghumidityStoragetemperature10%~90%RH when surroundingtemperature is 30℃-20℃~+50℃ when no batteryINFRARED THERMOMETERDimensions (mm) 185×170×50 185×200×50Weight(g) 500 600


57Beijing TIME High Technology Ltd.www.timeinstrument.comTechnical SpecificationMeasuring range 400~1500℃Accuracy ±1%Repeativity ±0.5%Optical resolution 50:1Spectral response8~14μmResponse time≤1000msFeatures●Display of Max., Min.,△T, Avg. and real time valueDisplay resolution 0.1℃ or 0.1℉●High/low temperature alarm●With backlight display●Display hold and date●Data storageTemperature displayBacklight℃/℉ Selectable√Standard Delivery●Main unit 1●AAA1.5V battery 3●Instruction manual 1●TIME certificate 1●Warranty card 1Display holdLow and hightemperature displayWork temperatureEmissivity√√0℃~50℃0.01-1.0 adjustableMemory20 readingsRelative humidity10%~90%RH noncondensing up to40℃(104℉)Storage temperature-20℃~+60℃PowerAAA 1.5V battery(3Pcs)TI300INFRARED THERMOMETERContinuous workingtime50hours(without backlight and laser)Dimensions(mm) 192×192×50Weight(g) 445


58Beijing TIME High Technology Ltd.www.timeinstrument.comTechnical SpecificationModel TBS-1160 TBS-1161Image sensorCMOS image sensorResolution640h×480vTip diameter 5.5mm 5.5mm/8mmTBS-1160/1161●Easy connect any computer, Photo shooting &Recording abilityInsert tube length 1m~30m 1m~2mFrame rate20~30fps●easy ability editing to fileStandard Delivery●Lens (5.5mm dia.300,000pixel for 1160) 1●Lens (5.5mm dia.8.0mmdia. optional for 1161) 1●Cable (1m) 1●USB cable (50cm) 1S/N ratioExposureWhite Balance42dbAutomaticFixField of view(FOV) 67°Depth offield(DOF)1.5cm~10cm/10cm~∞2.5cm~8cmLight source4 white LED-5.5mm6 white LED-8mm6 white LED-5.5mm6 white LED-8mmPowerDC 5VDisplay Mini USB 2.0TBS-1160/1161USB VIDEO/PICTURE CAPTUREENDOSCOPEVideo Out FormatRecording/CaptureNTSC & PAL640×480 JPEG or640×480 AVI according to PC or notebook


59Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Lens(5.5mm dia.,300,000pixel) 1●Cable (1m) 1●Li-ion battery (3.7V×1800mA) 2●Charger 1●SD card (2G) 1●USB cable (50cm) 1●TV out cable 1●45°~90°mirror(optional) 1Technical SpecificationFunction●Quick snap●Quick video recording●Quick review●Av out●Video/picture viewer●16 Language selected TBSImage sensorStorage MemoryResolutionOperational InterfaceTip diameterInset tube lengthCMOS image sensor1 to 4G PUSH-PUSH Type SD Card (Notsupport SDHC Type) (Support FAT)640h×480V8 key3.9,5.5,8,10,12,16,20mm(option)1,2,3,5,10,20,30m(option)Features●3.9mm~10mm Lens●1m~30m Cable●640×480 ResolutionFrame rateS/N ratioExposure~30fps42dbAutomaticWhite balanceFixField of view(FOV) 67°Depth of Field(DOF)1.5cm~10cm/10cm~∞Light source4 white LEDPowerDC 5VDisplay3.5" TFT LCDMonitor640×480 pixelsTBS-2486VALUED VIDEO BORESCOPEInterfaceBatteryVideo out formatRecording mediumMine USD 1.1/AV out/ AV inRechargeable Li-polymer battery(3.7V)NTSC&PAL2GB SD card×1 support to 4GB SD card


60Beijing TIME High Technology Ltd.www.timeinstrument.comHigh Density 8 pcs WhiteLED LightTechnical SpecificationStandard Delivery●Lens (5.5mm dia.,300,000pixel) 1●Cable (1m) 1●Li-polymer battery (3.7V×2100mA) 1●Charger 1●TV out cable 1●45°~90°mirror(Optional) 1Image sensorEffective pixelsLens dimensionsResolutionLens1/5" color CCDI image sensor640(H)×642(V)NTSC/720(H) ×682(V)PAL38(L) ×10.5(W) ×0.55(H) mmMore than 420 TV lines2.7mm wide angle view lensLED LightHigh Density White LED light×8pcsMin.illumination0.5 LUX@F2.0S/N RatioMore than 42dBCamera Head Diam.12mm Cable Length 1~20M(Optional)Head Dimension12mm(dia.)×45mm(L)View angle 60°Focus angle2~5cm (Near)/7cm~Infinity(Far)Operating Temp 0~60℃TBS-2488ZIZO BORESCOPELCD Display3.5" LCDSystem formatNTSC/PALPowerDC 5V/2A(charger)Zoom ×1.0, ×1.5, ×2.0, ×2.5


61Beijing TIME High Technology Ltd.www.timeinstrument.comApplication●Security/Law Enforcement and Salvage●Aviation●Air/Water Pipe Cleaning●Automotive/Motocycle●Marine/Machinery●Mechanics●Electronic industryStandard Delivery● Lens (12mm dia.,400,000 pixel and 5.5mm dia.,300,000 pixel optional) 1●Li-polymer battery (3.7V×2100mA) 1●TV out cable 1●Hook(for 12mm Lens ) 1●Magnetic attachment (for 12mm lens) 1●45°~90°mirror(Optional) 1●Cable(1m) 1●Charger 1Technical SpecificationImage Sensor 1/18 CMOSEffective Pixels 537(H)×505(V) NTSC 628(H)×582(V) PALResolution More than 320 TV LinesEffective Pixels 640×480Gamma 0.45LED Light High intensity WHITE LED Light×4pcsLENS1.4mm wide angle view lensMin.illumination 0.7LUX@F1.8S/N Ratio More than 42 dB(AGC OFF)Camera HeadDiam.6mm Cable Length 1~20m(optional)Head dimensions6mm(diam.) ×20mm(L)View Angle 60°Degree Depth Field3cm~7cm(±0.5cm)Storage Temp.LCD Display0℃~60℃2.5 inch LCDTBS-5501Effective Pixels 640×480System Format NTSC/PAL(Compatible)BatteryBuilt in Lithium batteryPORTABLE BORESCOPEPowerDimensions(mm)DC 5V/2A180 (L)×85(W)×25(H)/150g


62Beijing TIME High Technology Ltd.www.timeinstrument.comBrief Introduction● TC100/110 is used to detect the thicknessofconcretecoveringlayer and rebar diameter.Besides, it can detectthe location of magneticsubstance and electric and electric conductor innon-magnetic and non-conductive medium, e.g.cable inside wallbody and water & heating pipeetc. it is a kind of intelligent nondestructive testequipment possessing the functions of automaticdetection, data memory and output.Features●Acceptance inspection of cover after formwork isremoved●Locate rebars to avoid them when drilling holes●Provide essential data (location, cover, diameter ofrebars) for strength calculations of reinforced concretestructures●Measuring concrete cover thickness●Quality assurance in mass production of fabricatedconcrete elements●Measuring the thickness of concrete over steelreinforcement and metal pipes●Signal strength bar display and sound alarm for highaccuracy●Real time graphic output both to screen and printer●Data processing software compatible with windows95/98/2000/Me/WT/XP●Auto calibration, correct the system error●Three scan modes for TC110:grid pattern, profile scanand large area scan●For TC110: direct display grid and profile image ofrebarsTC100/110REBAR LOCATORTC100TC110Standard Delivery (TC100)●Main unit1●Transducer1●Software1●Signal cable1●Shoulder strap1●AA battery (LR6) 6●Key2●Instruction manual 1●TIME certificate 1●Warranty card1Technical SpecificationCovering layer thicknessmeasuring rangeRebar diameter measuringrangeTolerance of coveringlayer thicknessOther special testing conditions●Avoid strong magnetic field interruption●Avoid high temperature●Has no corrosive gas in the atmosphericStandard Delivery (TC110)●Main unit1●Transducer1●Software1●Signal cable1●Shoulder strap1●Connecting cable 1●Scanning trolley 1●AA battery (LR6) 6●Key2●Instruction manual 1●TIME certificate 1●Warranty card1Range Ⅰ:6mm-90mmRange Ⅱ:7mm-180mmØ6mm- Ø50mmRange ⅠRange Ⅱ±1mm 6mm-59mm 7mm-79mm±2mm 60mm-69mm 80mm-119mm±4mm 70mm-90mm 120mm-180mmDisplayOperating temperature -10℃~ 40℃Relative humidity


63Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Transducer 1●Software 1●Signal cable 1●Bracket 1●Tapeline 1●Oil pen 1●Electric torch 1●Shoulder strap 1●AA battery (LR6) 6●Key 2●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationBrief Introduction● TC200 is used to measure concrete crack depthby applying principle of acoustic diffraction.It also can be used to measure propagationvelocity of ultrasonic wave in concrete. Thisinstrument is a kind of intelligent nondestructivetest equipment possessing the functions ofautomatic detection, data memory and output.Features● Entire English display, clear and easy to use● Direct digital read out of the crack depth● Use special bracket to ensure the accuracy oftwo testing points● A data base is set up to store and managecompleted test data for analysis reporting● RS232 interface to PC<strong>Testing</strong> range4mm~500mm≤5mm (when crack depth is less than50mm)Tolerance≤10%W (W means the crack depth)(when the depth is more than 50mm)Memory25000 test dataPower AA batteries (LR6) x 6DisplayLarge graphic displayOperating temperature -10℃~40℃Relative humidity


64Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Transducer●Software●Cable for probe●USB connecting cable●Measuring tape●Shoulder strap●Vaseline●Charger●Calibration stone●Instruction manual●TIME certificate●Warranty card1212211111111Brief Introduction● TC210 accomplishes the fast measurementsof crack depth by means of analyzing thegeometry relationships between the diffractionangle and the crack depth. It is designedspecifically for the non-destructive testing of thecrack depth of bridges, tunnels, constructionsand such concrete structures. The crack depthcan be obtained without measuring velocity.Technical SpecificationMeasuring range 10-500mmTolerance≤±5%Operating mode Automatic and manualInterfaceUSBMemoryMore than 10000 test dataFeatures● New design of automatic reading device for thespace between two probes● Battery life can be greatly extended by lowpowerdesign● Manage the measured data, print and generatereport function available by software● Easy to operate by the controller with englishmenu● Work in wet environment available bywaterproof and moisture-proof designPower10Ah Li batterycontinuous working more than 30 hoursOperating temperature -20℃~50℃Relative humidity


65Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Transmitting transducer●Receiving transducer●Supporting bar●Interphone●Signal cable●Charger1115211●Shoulder strap●AA battery (LR6)●AAA battery (LR03)●Key●Instruction manual●TIME certificate●Warranty card1662111Technical SpecificationBrief Introduction● TC300 is used for measuring the thicknessof nonmetallic plate indirectly, especiallyfor concrete slab.This gauge is to measurethe concrete slab thickness mainly by usingdistribution characteristics of electromagneticfield and possesses function of thicknessmeasurement, data analysis, data storage &output etc. it is a kind of intelligent thicknessmeasuring instrument that is portable,convenient and accurate.Measuring range 50-350mm±1mm[When thickness = (50-260mm)]Accuracy±2mm[When thickness = (261-350mm)]Memory32000 test data and 4000 componentsPower AA batteries (LR6) x 6DisplayLarge graphic displayOperating temperature -10℃~40℃Features● Measuring the thickness of concrete, rock, glassand other nonmetallic plates● Sound alarm, signal strength bar are used toimprove measuring accuracy● Direct digital read out of the thickness valueavoid the inaccuracy of manual comparison● Test data create and data logging● RS232 and USB interface to PC● Real time analysis of the tested dataRelative humidity


66Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Transducer 1●PDA main unit 1●Software 1●Signal cable 1●USB cable 1●Universal coupling 1●Extension rod 1●SD card reader 1●Charger 1●Instruction manual 1●Warranty card 1●TIME certificate 1Brief Introduction● TC410 is widely used for non-destructivetesting of the crack width of bridges, tunnels,constructions and such concrete structures.During the detection, the system takes theimage of crack automatically and displays realtimeimage and width data of cracks. Theimage data can be saved automatically.Technical SpecificationThe main probe Specialized CMOS cameraControllerPDADisplay modeAutomatic calculation, save and displayFeatures●The PDA design with data acquisition probe●Automatic image recognition and intelligentwidth calculation technique●Quick measurement without any adjustment●Large screen of PDA for the more accurate andclear image●Image file can be saved in JPEG format●Powerful processing software can be able tosave and analyses image and dataMeasuring range 0.0-3.0mmAccuracy0.02mmMagnification60 XImage formatsJPEG (Around 10K per image)MemoryInternal memory (SD card extension)Interface USB 2.0PowerLithium batteryOperating temperature-20℃~+60℃Dimensions180mmx100mmx50mmNet weight1kgTC410CRACK WIDTH GAUGE


67Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Hammer 1●Carborundum stone 1●Flip tension spring 1●Buffer spring 1●Screwdriver 1●Radius gauge 1●Carrying case 1●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationMeasuring range 10 to 70N/mm 2Impact energy2.207NmBrief Introduction● TC500N is a portable instrument to test thecompressive strength of concrete structures orrock in non-destructive testing field. The typeN hammer is designed for measuring concretethickness 100mm or more, or concrete with amaximum particle size no more than 32 mm.Features● Suitable for testing a wide variety of concrete,rock and bricks● Light, flexible and simple operation● Friction adjusted by the pointer● Adopt stretching techniques to make the buttonworking well● Supplied with carborundum stone to preparetestsurfaceSpring extension75±0.3mmFriction of pointer system 0.65±0.15NLength of pointer20.0±0.2mmRadius of spherical tip25±1.0mmWorking length of the spring 61.5±0.3mmMean value of steel-anvil rating 80±2Flip tension spring rigidity 785.0±40.0N/mOperating temperature0℃~+40℃Storage temperature-10℃~+50℃Hammer 280mm×Ø60mmDimensionsWith case 320mmx170mmx86mmWeightHammerWith case1.0Kg4KgTC500NCONCRETE TEST HAMMER


68Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Test hammer sensor●Sensor cable●Software●USB connecting cable●Power charger●Carborundum stone●Instruction manual●TIME certificate●Warranty card1111111111Optional Accessory●Printer●Power charger for printer(9V/2V)Technical SpecificationBrief Introduction● HT225-V is a portable instrument to test thecompressive strength of concrete structures orrock in non-destructive testing field. The reboundvalue can be converted into a reading on thedigital display, and the estimated mean value,standard deviation and concrete strength can beshown.ModelHT225-VMeasuring range 10-60MPaImpact energy 2.207JFeatures● The main unit integrated with the sensor,portable design● True color LCD screen, high resolution of176*220mechanical hammers● Powered by high-capacity rechargeable lithiumbattery● Non-contact grating sensor with high precision● Unique sound alarm of rebound value● Easy to generate report by printer on the spot● Automatic delete exceptional value and calculatecomponent results● Possibility to store, display and transfer data toPC with USB interfacel ,Spring extensionDisplayData storageMean value of steelanvilratingFlip tension springrigidity75mm16-bit true color, 176 * 220 resolution480000 testing results80±2785N/mPower supplyRechargeable lithium batteryHT225-VDIGITAL CONCRETE TESTHAMMERPower consumptionInterfaceWeightMaximum backlight situation≈100mA(Voice off)USB2.0 full-speed1.1Kg


69Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Electrode●Signal cable●USB connecting cable●RS232connecting cable●Connecting bar●Extension cable●Clamp●Hygrothermograph122111111●Measuring tape●AA battery (LR6)●Shoulder strap●Instruction manual●TIME certificate●Warranty card161111Technical SpecificationBrief Introduction● TC600 rebar corrosion detector is designedfor assessing the corrosion of the reinforcedconcrete structure and components by half-cellpotential method,the electrode is passed over thesurface of the concrete and the potential voltagedifference is recorded, then the corrosion of rebaris assessed.Features● Non-destructive testing the corrosion in rebar● Detection of the corrosion condition of the rebaraccurately and conveniently by field potentialmeasurement● Possibility to store, view, delete data andtransfer all readings to PC with USB interfaceand serial port● Faster and more accurate processing of data,resentation of test area and reading as numbersor graphics● Display of measurement values in 9 grey-scaleorcolorful graphicsl● Permanent copper/copper sulphate referenceelectrodes to measure electrical potentialsMeasuring methodMeasuring rangeResolutionMemorySpace between testing pointsInterfacePower supplyOperating temperatureRelative humidityPotential measurement±1000mv1mvMass storage1~100cm adjustableRS232 and USBAA batteries (LR6)×6-10℃~+40℃


70Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit●Software●USB connecting cable●Batteries AA 1.5V●Power supply●Instruction manual●TIME certificate●Warranty card11121111Brief Introduction● TCD100 is a light-sensitive instrumentmainly used in colorimetry for measuring andpsychophysical analyse the color of an objector color sample. This portable colorimeter iseasy to use and can be carried anywhere,irrespective of environmental conditions.Technical SpecificationTest accuracyColor spaceMeasuring rangeMeasuring timeWithin 0.2△E*ab△E*ab、CIE_Lab、△L、△a、△b、CIE_LchL:0~100 a:-128~127b:-128~127About 3 secondsFeatures● Easy and direct operation with the simpleunction keys● Display directly color difference by △E*ab,△L*a*b,CIE_L*a*b, CIE_L*c*h● Silicon photodiode as light sensors for analyzingthe absorption spectra●Standard deviation within △E*ab0.2 (Testcondition: choose average values by 12 pcswhite tabula)●Possibility of measuring any color of smoothsurface● LED illumination available● Communication with PC the practical softwareMeasuring intervalMeasuring apertureAutomatic shutdownMemoryField of viewLight sourceSensorScreen typeAbout 2 secondsØ8mmAutomatic shutdown after 5 minuteswaitingKeep a group of data automaticly(Without connecting to PC)10°regulated by CIEC light sourceCorrect silicon photodiode (seedarray)LCD with backlightPowerOperating environmentSize1.5V AA batteries×2, DC/5V (1.5A)0℃~+40℃;lower than 85% relativehumidity170mm×50mm×48.8mmWeight204g ( without batteies)TCD100COLOR DIFFERENCE METER


71Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Main unit 1●Software 1●USB connecting cable 1●Standard black cavity 1●Standard white tabula 1●Batteries AA 1.5V 4●Power supply 1●Instruction manual 1●TIME certificate 1●Warranty card 1●Powder & Pellet Test 1Technical SpecificationRepeat accuracyWithin E*ab0.08 (intervalmeasuring30 times aftercalibrating white tabula)ErrorWithin E*ab0.5Features● The 2.4” width colorful screen and portabledesign● Possibility of measuring any color of smoothsurface or powder● Display directly color difference by △E*ab,△L*a*b, CIE_L*a*b, CIE_L*c*h, XYZ, RGB● SCI and SCE inspecting systems selectable● Yellowness & Hunter Whiteness measurements,eg. Paper & Spaghetti etc. can be tested● Colour matching function for user's reference● Data can be saved and used in the PC; Astandard database in the software can be savedin the PC with excel format● LAB value can be input by manual as a standard● Professional color analysis software forthe colordata analysis and color differencediagrammatic output● Tolerance setting, auto-judge color differencevalues and color deviation for judging the coloreasilyColor spaceLighting/inspecting systemLight sourceMeasuring apertureField of viewInspection conditionMemoryInterfacePowerOperating environmentSizeXYZ, RGB, L*a*b, L*C*H,△E*ab, △L*a*b*,△L*c*h*8/d(8°Falloff/diffusereflection)SCI(include Flat MirrorLight)SCE(eliminate Flat MirrorLight)Halogan light source8mm10°regulated by CIED65100 groups of sample and 100data for each sample(Withoutconnecting to PC)USB1.5V AA batteries×4, AC-DCalternating current0℃~+70℃;lower than 85%relative humidity77mm×86mm×210mmWeight550g ( without batteies)TCR210PRECISE COLOR READER


72Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery● Main unit● Software● USB connecting cable● Standard Panel● AAA batteries● Power Supply● Instruction manual● TIME certificate● Warranty card111141111Optional Accessory● Mobile Memory CardBrief Introduction● HP-380 is a portable instrument mainlyapplied for the quality control in the field ofpaints,varnishes, printing,printing ink,building material,plastic cement, ceramic,artificial leather,hardware. It covers the rangenecessary to measure almost surface from highgloss to matt.Features● The appearance design conforms to physicaldynamics, high accuracy and stable performanceeasy to operate● Multi-angle one-key measurement: One-keyoperation can complete three angles’measurement to meet data demand underdifferent gloss conditions, incident angle oflight measurement conforms to ISO and ASTMstandards● Professional analysis software for the gloss dataanalysis andoutput, easy to transfer data by bluetoothand mobile memory card● Automatic calibration, internal calculation of max,min, mean standard deviation and coefficient ofvariation● Optional angle mode: measurement angle orangle combination can be selected by user’sneed● Mass storage: under triangle mode, 10000 timesor 1000 groups of measurement data can bestored● Alarms for low-power and “Not enough storagespace”HP-380Technical SpecificationMeasurementangleStandardsIncidence angle(GU)Measuring opticalspot (mm)20° 60° 85°ISO2813,ISO7668, ASTM D523,ASTMD2457Gs( 20°):0.0~120Gs( 60°):0.0~120Gs( 85°):0.0~120Gs( 20°):10*10Gs( 60°):9*15Gs( 85°):5*38Resolution (GU) 0.1 1Repeatability(GU)Indication error(GU)Zero value error(GU)Power SupplyOperatingtemperatureStoragetemperatureRelative humidityDimension0.5 0.5%Gs( 20°):120~2000Gs( 60°):120~1200Gs( 85°):120~160-1.5~+1.5 -1.5%~+1.5%0.2Both AAA batteries and power supply10°C~40°C-10°C~70°CLess than 85%, Non-condensation164 mm x 58 mm x 88 mmTRI-ANGLE GLOSSMETERNet Weight520 g


73Beijing TIME High Technology Ltd.www.timeinstrument.comBrief Introduction● DJ series are designed for quick inspecting a wide rangeof non-conductive coatings and linings for pinholes,porosity and other faults by means of pulsed voltagein the non-destructive testing field. It is widely used inthe petro-chemical, pipe mills, plastic fabrication andaerospace industries.Standard Delivery●Main unit 1●High voltage detector 1●Brush probe 2●Brace rod 1●Earth lead 1●Earphone 1●Power charger 1●Fuse 2●Shoulder strap 1●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationOptional Accessory●Arc-shaped brush●Circle probeModel DJ-6(A) DJ-6(B) DJ-9Features●Display of output high voltage directly●Clear LCD with blue backlightThicknessdetection0.03-1mm0.5-10mm●Switch off automatically●State of charge indicatorOutput voltage 0.6KV-8KV 0.6KV-35KV (Adjustable)●DJ-6(A): mainly used for the antisepsis of pottery●DJ-6(B): mainly used for petroleum pipeline (Highvoltage)●DJ-9: displays leakage points of antisepsis coatingontwo digitsDC voltageConsumed power12V6WAlarmBoth earphone and buzzerDisplayThree digit LCD, Fully touch screenDimension220x130x88mmDJ SERIESHOLIDAY DETECTOR


TUP SERIESUNDERGROUND PIPE ANDCABLE LOCATOR74Beijing TIME High Technology Ltd.www.timeinstrument.comBrief Introduction●TUP Series image the subsurface wires, cables andpipes by the electronicmagnetic wave transmissionin non-destructive testing field. It provides precisepinpointing of buried services, which can be used inthe field of petroleum and chemical, rock, soil, ice, freshwater, pavements and structures.Standard Delivery●Tube-like probe●Detecting cable●Output cable●Earth lead●Ground rod●File●Magnet1111111●220V power cord●Power charger●1A fuse●Instruction manual●TIME certificate●Warranty card111111Features●Quick charge automatically●Auto switch the signals of the output voltage and theoutput current●DC-AC power conversion automatically●Application of the high anti-interference technique●Large and high resolution screen guarantees the cleardisplay●Auto functions of protection and adjustment●Three-proofing design and modular structure for betterreliabilityTechnical SpecificationModel TUP100 TUP200 TUP300 TUP400TransmitterRated output0-25W 0-25W 0-30WAdjustableAdjustment automatically, Servo controlSignalLow frequency modulation signalFrequency 1K±0.1Hz 1KHzOutput resistance0-500Ω,5-500Ω,5-1000Ω,Manually matchAutomatically matchAutomatically matchTransmitting distance0.03m-5Km0.03m-8Km, Extension to furtherExtension to further than 5Km graduallythan 8Km graduallyWorking voltage 12VNiMh battery pack12VBuilt-in NiMh battery pack12.8VBuilt-in Li battery packOperating temp. -10℃~+50℃ -20℃~+60℃ -30℃~+60℃Control system Analog signal DSP+ Vector control, System update availableAdjustment system Numeric keypad Numeric knob Numeric keypadWeight 2.8kg without battery 3.0kg with battery 7.0kg with batteryDimension 255×255×100mm 276×227×98mm 456×335×133mmPipe locatorSensitivity -56db -65db -85dbPositional deviation ≤10cm ≤5cmDepth measurement ≤5m ≤8m ≤10mWorking voltage 9.6V NiMh battery pack 9.6V Li battery packDimension 165×155×68mm 165×110×68mmHoliday detectorAccuracy ≥0.5mm 0.25mmPositional deviation ≤10cm ≤5cmWorking voltage 9.6V NiMh battery pack 9.6V Li battery packDimension 165×155×68mm 165×110×68mm


75Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery●Power box 1●Magnetic yoke(≥55N) 1●Power cord 1●Light bulb (5W/12V) equipped with horse-shoe probe 5●Fuse (5A) 5●Instruction manual 1●TIME certificate 1●Warranty card 1Brief Introduction● CJE-2A electromagnetic yoke, horseshoe-typedetector is to use magnetic iron yoke on theworkpiece by AC and DC magnetization. It cando magnetized testing of various components,including the partial magnetization inspection oflarge components. It is composed of non-contactswitch made of silicon, with little noise and longservice life. It has small size, light weight, largelifting force and adjustable joints, especially fordetection of flat welds, fillet welds, pressurevessels, piping and components with complexshape. Its output voltage is low, which is suitablefor the equipment that does not allow high-voltageto enter.Technical SpecificationModelCJE-2AInput voltage AC 220V ± 10%VOutput voltageAC 36VOutput current>10AMagnetization methodACProbeALifting force≥55N(5kg)Temporary load rate 50%TCJE-2AMAGNETIC YOKE FLAWDETECTORDistance betweenA)magnetic yoke probe polesB) horse-shoe probe polesC) ring-type magnetic polesDimensionNet weightA): 0~255mmB): 0~160mmC):Φ150mm 1800ATNote: Three probes are in commonuse, but only one with a random inthe standard delivery.230×160×120mm5kg


76Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures● Small size, light weight and big lifting force.● Especially suitable for detecting plane weldedseam, fillet welded, pressure vessel, pipelineand complicated parts.● Three probes are available:1) Yoke type probe: equipped with livejoints, mainly used in the detection ofworkpiece with plane or curved surface.2) Horseshoe type probe: mainly used inthe detection of fillet welded and partialinspection of inner or outer angles.3) Magnetic ring: can satisfy the inspectionof workpiece with circumferential crack, itis especially convenience in the detectionof fatigue cracks as well as used indemagnetization when the instrument isaway from the workpiece.Standard Delivery●Main unit 1●Yoke probe, horseshoe probeor magnetism ring 1●Input power cord 1●Output cord 1●Fuse(5A) 5●Light bulb (12V/5W) 5●TIME certificate 1●Warranty card 1●Instruction manual 1Technical SpecificationInput voltageOutput voltageAC 220V±10%,50HzAC 36V, DC8VWorking currentInput 5A, Output AC8A~15ADistance betweenmagnetic polesYoke: 0~255mmHorseshoe: 0~165mmMagnetism ring: Ø150mmLifting powerModel A>5kg(AC), =36kg(DC)Model D>4kgModel E=1800AT(AC)Probe weightYoke:2kgHorseshoe:2kgMagnetism ring: 2.5kgTCEE-IAC YOKE-MAGNETIC PARTICLEFLAW DETECTORDimensions(mm)SensitivityWeight230×110×165 (L×H×W)Clearly display A standard block5.5kg


77Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures● Applying rotating magnetic field to magnetizethe workpiece.● With high reliability and stability, portablemagnetic particle flaw detector● With 4 wheels and lighting bulbs on the probe,convenient for continuous detection.● Widely used in the detection of flat boiler, ballpot, fillet welded.Standard Delivery●Main unit 1●Probe 1●Power cord 1●Output cable 1●Fuse(8A) 1●Light bulb 2●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationLifting force≥12kg ( the clearance between the probesurface and the workpiece surface shouldbe less than 1.5mm)The distance between themagnetic pole100×100mmWorking voltage36VSensitivityClearly display the slot in the standardblockTCXX-3BROTATING-FIELD FLAWDETECTORPower voltageDimensionsWeightAC 220V, 50HZ140(W)×260(L)×170(H)mmPower box:8kgProbe:2.5kg


78Beijing TIME High Technology Ltd.www.timeinstrument.comBrief Introduction● TCLF series summarized the merits of inspectionby direct and alternating currents. The flawdetectingdepth is improved by adopting lowfrequencyelectric current,and this pulsating currentcan enable the slight vibration of the magneticpowder ranks, which facilitates the permutationof the magnetic powder and forms the magneticmark. it is widely used in the shipyard,aerospace,steel, mill, foundry, weldment or vehicle inspectionFeatures●Completely portable single-handed operation●Reliable location of defects in ferrous metals●The deeper penetrating depth by the magneticfield●Find of artificial crackle (0.1*2*30mm) at 6mmnder the surface●Perfect float of magnetic particles for easy to beabsorbed on the defects●No need to demagnetize after flaw detection●Detection directly without any process on thesurfaceStandard Delivery●Power box 1●Horseshoe probe 1●Connecting cable 1●Instruction manual 1●TIME certificate 1●Warranty card 1Technical SpecificationModel TCLF-J50D TCLF-Z12DPower supply modeAC + lowfrequencyMax. power 400W 50WOutput voltageWorking currentDC resistance 8.5ΩProbe shapeAC:220VLow frequency:70-140V2.4A( pulsating current>10A)HorseshoeDC + low frequencyDC:12VLow frequency: 7-36V2A( pulsating current >6A)Probe span50-300mm(Adjustable)50-200mm (Adjustable)Lifting force ≥4.5kg in AC ≥18kg in DCDetection depth3-6mm (Low frequency)Frequency of currentAdjustablePower220V ACRechargeableTCLF-J50D/Z12DLOW-FREQUENCY MAGNETICFLAW DETECTORDimensionWeightProbe 200×50×150mm 208×48×148mmMainunit130×112×46mm 260×220×100mmProbe 3.6kg 3.2kgTotal 6.0kg 7.5kg


79Beijing TIME High Technology Ltd.www.timeinstrument.comStandard Delivery● X-rays generator● Controller● Power cord(10m)● Controller cable(25m)● Fuse(20A)● Ground wire● TIME certificate● Warranty card● Instruction manual111111111Features● Detect the inner defects of spare parts andelding lines, make quality assessment of theproducts● NDT detecting method and widely used inthe industries such as machine manufacture,aviation, railway, pressure vessel, boiler,chemical industry● Isolated by SF6 and forced cooling by fan● Penetrate A3 steel in a few minutes, theblackness is no less than 1.5 , sensitivity issuperior than 1.5%● The controller adopts photoelectric isolatedmicrocomputer control system to protectvoltage, current and temperature. The controloperation is reliable, automatic and intelligence● Ceramic X-ray tube is made of superioroxygen free copper, high dense ceramic, superhigh vacuum degree, enjoys the merits of hightemperature resistance and good anti-seismicTechnical specificationModel TXG200 TXG250 TXG300Power AC220V±10% 50HzPower capacity(kW) >2.0 >2.0 >3.0Tube voltage (Kvp) 80-200 130-250 150-300Max. tube current( mA) 5 5 5Focus size(mm ×mm) 1.5×1.5 2.0×2.0 2.5×2.5WeightGenerator 17 21 28(Kg) Controller 9X-ray beam radiation40º+5anglePenetration A(mm) 29 40 50Isolation modeSF 6 gasOperating temperature -25℃-+40℃Relative humidity ≤85%1、Focus length:600mm2、Exposure time:5 minutes3、Film:N-Ⅲ industrial radiographic film,TXG-200/250/300X-RAYS GENERATORTransilluminationSafety workingpressurewith lead foil on both surface4、Darkroom treatment:temperature:±2℃,Developing: 5minutes,Darkness≧1.50.35-0.50mPa


80Beijing TIME High Technology Ltd.www.timeinstrument.comModelWork DiscNo.DiscDiameterRotation Speed (rpm/min) RemarkFeatures●Beautiful, durable ABS shell, stainless steelstandard parts●Equipped with quick-changed polishing disc,multi-style clamps●With micro-processing control system and “onekey-restore”program function●Freely set rotation direction, digital displayrotation speedTIMEGP-160E1 200/250 50~600 (stepless speed) 220V/50HzTIMEGP-260E2 200/250 50~600 (stepless speed) 220V/50HzTechnical SpecificationTIMEGP-160E Quantity TIMEGP-260E QuantityGrinding & PolishingGrinding & Polishing1MachineMachine1Polishing Cloth 1 Polishing Cloth 2Grinding Paper 1 Grinding Paper 2 separatelyPolishing Disc 1 Polishing Disc 2Buckle Ring 1 Buckle Ring 2Sealing Ring 2 Sealing Ring 4Instruction Manual 1 Power Supply 1TIME Certificate 1 Water Inlet 1TGP- 160 E / 260EGRINDING/ POLISHING MACHINEWarranty Card 1 Instruction Manual 1TIME Certificate 1Warranty Card 1


81Beijing TIME High Technology Ltd.www.timeinstrument.comTGP-1000AUTOMATIC GRINDING / POLISHING MACHINEFeatures● TIMEGP-1000 Automatic Grinding & Polishing Machine is based on internationalstandards, adopting international advanced technology to create latest abrasivepolishing with high-precision and full automation● Mechanical transmission load● Figures display sample speed● Load pressure and adjustable sample time● Disc has two functions of two speed and stepless speed● Grinding spindle can regulate steplessly● Beautiful, durable ABS shell, stainless steel standard parts● Equipped with quick changed polishing disc, multi-style clamps● Central loading● Large-capacity automatic abrasive distribution system● Simultaneously process many pieces of style● With “One-click-restore” program featureTechnical SpecificationRotation speed50~600 r/min (stepless speed) or 150r/min, 300r/min (two constant speeds)Loading ranges 1~200NSample time 0~999SDiameter of grinding &polishing discØ250mmPower supply220V, 50HzDimension660*380*640mmMain accessories1pcs water-inlet and 1pc water-outlet, 2pcs quick-changed disc, 1pc leveling clamp etc


82Beijing TIME High Technology Ltd.www.timeinstrument.comTCM-80/100CUTTING MACHINEParameters/Model TIMECM-80 TIMECM-100Cutting Power3.0 KWMax. Cutting Diameter 80mm 100mmSpeed2800 r/minGrinder Specification 250*2*32mm 350*2.5*32mmPower380V, 50HzT-working table, Double-driving vise, Outside cooling systemDimension720*700*620mmTIMECM-80/100 Packing ListName Unit Quantity RemarksCutting Machine unit 1Wrench pc 2 36mmCutting Tablets pc 2Water Inlet pc 1 350*2.5*32mmWater Outlet pc 1Cooling Lubricating Liquid bottle 2 1000mlTube Clamp pc 1Instruction Manual pc 1TIME Certificate pc 1Warranty Card pc 1


83Beijing TIME High Technology Ltd.www.timeinstrument.comTCM-80Z/100BCUTTING MACHINETechnical SpecificationParameters/Model TIMECM-80Z TIMECM-100BFeatures● LCD shows all kinds of parameters● Cutting diameter: 5~80mm (100B:5~100mm)● Cutting capacity: 100mm*200mm● Free to switch manual and automaticcutting mode● Big cutting cabinet, tempered glassobservation window● Non-burning movement cuttingmethod, improve cutting quality● Automatic back-knife function aftercutting● A bidirectional feed cutting mode,increase the cutting depth ofCutting Speed2.25, 3, 4, 5, 7, 9, 12, 15 mm/minGrinder Speed2100rpmDisplayLCD with high-resolution backlight dot-matrixPowerThree-phases with four cables, 380V, 50HzDimension 780*800*600mm 930*700*610mmPipe locatorSensitivity -56db -65dbPositional deviation ≤10cm ≤5cmDepth measurement ≤5m ≤8mWorking voltage 9.6V NiMh battery packDimension 165×155×68mm 165×110×68mmHoliday detectorAccuracy≥0.5mmPositional deviation ≤10cm ≤5cmWorking voltage 9.6V NiMh battery packDimension 165×155×68mm 165×110×68mmStandard DeliveryTIMECM-80Z Quantity Remarks TIMECM-100B Quantity RemarksCutting Machine 1 Cutting Machine 1Water Tank 2 36 Water Tank 2 36Cutting Tablets 1 Cutting Tablets 1Grinding Paper 2 350*2.5*32mm Grinding Paper 2 350*2.5*32mmWater Outlet 1 Ø32*1.5mm Water Outlet 1 Ø32*1.5mmWater Inlet 1 Ø25*1.5mm Water Inlet 1 Ø25*1.5mmLarge Hose Clamp 1 Ø32-Ø44 Large Hose Clamp 2 Ø22-Ø32Small Hose Clamp 2 Ø16-Ø25 Wrench 1 12-14mmWrench 1 12-14mm Wrench 1 24-27mmWrench 1 24-27mm Wrench 1 36mmWrench 1 36mm Cooling Lubricating Liquid 1 1000mlCooling Lubricating Liquid 2 1000ml Instruction Manual1Instruction Manual 1TIME Certificate 1TIME Certificate 1Warranty Card1Warranty Card 1


84Beijing TIME High Technology Ltd.www.timeinstrument.comTAM-5AUTOMATIC MOUNTING MACHINEFeatures●Make the irregular specimens to meet the following sample proceduresby mounting methods●Protect the edge and prevent the surface from being defected duringsample process●Widely used in metallographic laboratory●Automatic mounting machine with the function of the in-and-out coolingsystem●Suitable for all hot mounting press(thermosetting or thermoplasticmaterial etc.)●4kinds of specific moulds is selectable to meet different requirementsTechnical SpecificationMoulding specification(mm) 25, 30, 40, 50PowerMaximum power consumptionSystem pressure setting rangeKeeping time setting rangeDimensionsCooling system220V, 50Hz1800W0~2MPa (Relative pressure range to sample: 0~72MPa)0~99mins 99 seconds615*510*500mmwater-coolingStandard DeliveryName Unit Quantity RemarksAutomatic Mounting Machine unit 1 Cutting MachineMoulds set Separately 1 Ø25mm, Ø30mm, Ø40mm, Ø50mmInlay Material bag 1 BakeliteHexagon Ring Spanner pc 1 4mmLeaky Bucket pc 1Anchor Bolt pc 4Oil Pointerpc1Water-inlet set 1Return Pipe meter 3Instruction Manual pc 1TIME Certificate pc 1Warranty Card pc 1


85Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures● Used for metal identification and analysis ofthe internal structure of organizations● An important device that studies themetallography and it is the key instrument toidentify the product quality in the industrialsector● Equipped with photographic equipment cantake metallographic picture to carry outartificial contrast analysis, image edition,data output, storage, management andother functionsTechnical SpecificationThree eyepiece tubeEyepieceTilting angle: 30 degreeAdjustable range: 55~75mmWide field eyepiece 10X (16mm)LensFlat field achromatic objective lens10X, 25X, 40X, 100X (oil)Stage150*200mm, Moving range: vertical15mm, horizontal 15mmEyepiece (optional)12.5X, 16X, 20X,10X flat-field eyepiece reticle (gridvalue 0.1mm)Lens (Optional)60X, 80XTMM-4XCMETALLOGRAPHY MICROSCOPEPhotography device (optional)1.Image adaptor, high-resolution colorCCD static and dynamic capture cardcamera, image analysis software,EPSON color ink-jet printer2.Digital camera, camera-specificadaptor


86Beijing TIME High Technology Ltd.www.timeinstrument.comFeatures● Latest model using dot-matrix method, withbattery reliability and printing quantity●Fast printing and compact size●Can be used with the following instruments:Bench hardness tester TH300/320Ultrasonicthickness gauge TT300ACoating thickness gauge TT210Vibration tester TV310/320Technical specificationPrinting methodDot-matrixSerial interfaceRS232(19200,9600,4800,2400,1200,600,300,150BPS selectable)Parallel interfaceCENTRONICS compatibleRibbonERC-22/ERC-09Ribbon life1000.000 characters/250.000charactersDimension(mm) 170×110×50Weight(g) 250TA230TIME MICRO-PRINTER