C3-Wastewater and Sewage Lifting Units, Pumps Stations - 2008.pdf
C3-Wastewater and Sewage Lifting Units, Pumps Stations - 2008.pdf
C3-Wastewater and Sewage Lifting Units, Pumps Stations - 2008.pdf
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Pumps</strong> <strong>Stations</strong><strong>Wastewater</strong> <strong>and</strong> sewage pumping stationsTechnical data Wilo-DrainLift WS 900/1100Wilo-DrainLift WS 900 with pumpWilo-DrainLift WS 1100 with pumpTS 40 TP 50 TP 65 MTS 40 TP 50 TP 65 TP 80 MTS 40Single Double Single Single Single Double Single Double Single Single Single DoubleTotal volume [l] 890 880 890 890 880 1230 1230 1230 1220 1220 1215 1220Impoundment volume [l] (bottom toupper edge of inlet)300 290 300 300 290 550 540 550 540 520 535 510Switching volume [l] max. 150 110 140 130 150 270 200 250 200 200 280 250Feed line [DN] 150 150 150 150 150 150 150 150 150 150 150 150Pressure outlet 1½" 1½" 2" 2½" 1½" 2" 2" 2½" 2½" DN 80 1½" 1½"Ventilation/cable [DN] 100 100 100 100 100 100 100 100 100 100 100 100Non-return valve GG25 1½" 1½" 2" 2½" 1½" 2" 2" 2½" 2½" DN 80 1½" 1½"Gate valvemade of material1½"redbrass1½"redbrass2"redbronze2½"redbrass1½"redbrass2"redbronze2"redbronzeWeight [kg] 70 95 73 75 72 95 113 97 115 125 94 1102½"redbrass2½"redbrassDN 80GG251½"redbrass1½"redbrass104 Subject to change without prior notice 09/2007 WILO AG