THERMAL OVERLOAD RELAYSThermal overload relays TM ..........................................................................................................2/1Thermal overload relays TRM ..............................................................................................2/2, 2/32Order-thermal overload relays .....................................................................................2/3Adaptor for separate installation ASM 40, ASM 22, ASM 75 .......................................2/3Application, standards and installation ......................................................................2/4Current time curves, ....................................................................................................2/4Technical data..............................................................................................................2/4Contactors with termal overload relays ................................................................2/5, 2/6Dimension drawings ...................................................................................................2/72/1


THERMAL OVERLOAD RELAYS TYPE TM 40FeaturesIn confority with: IEC 60947-4Ambient temperature compensatedDifferential trippingWith selectable manual or auto resetTrip indication1NO + 1NC auxiliary contactSelection and ordering dataThermal overloadsFor direct mounting onto contactor Overload setting range Type(A)CNN 9, CNN 12,CNN 18, CNN 25,CNN 32, CNN 400.1 - 0.160.16 - 0.250.25 - 0.40.4 - 0.630.63 - 1.00.2 - 5.00.8 - 1.251.0 - 1.61.25 - 2.01.6 - 2.52.0 - 3.22.5 - 4.03.2 - 5.04.0 - 6.35.0 - 8.06.3 - 10.08.0 - 12.510 - 1612.5 - 2016 - 25TM 40Weightskg0.152CNN 25;CNN 32, CNN 40,22 - 3028 - 38TM 400.162/1


In conformity with: IEC 60947-422/2


THERMAL OVERLOAD RELAYS type TRM 75 - TRM 400Selection and ordering dataThermal overloadsFor direct mounting onto contactor Overload setting range Type(A)CNM 3616 - 2520 - 3225 - 40TRM 75 - 36Weightskg0.38CNM 45CNM 6016 - 2520 - 3225 - 4032 - 5040 - 5750 - 63TRM 75 - 600.392CNM 75CNM 90CNM 11016 - 2520 - 3225 - 4032 - 5040 - 5750 - 6357 - 7063 - 80TRM 75 - 1100.40For individual mountingCNM 110CNM 140CNM 170CNM 200CNM 250CNM 315CNM 40070 - 10080 - 125100 - 160125 - 200160 - 250200 - 320250 - 400TRM 4002.4ORDER-THERMAL OVERLOAD RELAYSTypeSeting range (Upper value)Example: Thermal overload relay type TRM 22, current range ( 10 - 16 ) ATRM 22 16 AADAPTOR FOR SEPARATE INSTALLATION ASM 40,ASM 22, ASM 75For thermal overload relays typeTM 40TypeASM 40Weightskg0.04TRM 12TRM 22ASM 220.065TRM 75 ASM 750.1352/3


THERMAL OVERLOAD RELAYS TM and TRMApplication, standards and installationThermal overload relays TRM are intended to protect low voltage motors and otherconsumers against nonpermissible overloads and phase-failure operation.Relays are in conformity with IEC 60947-4-1, EN 60947-4-1 and VDE 0660.They are normally intended for mounting on our contactors see ordering table.Individual screw mounting of the TM 40, TRM 12 and TRM 22 relays on plane surfaceor snap-on fastening to 35 mm mounting rail (according to DIN EN 50022) ispossible by using a special adaptor type ASM 40 and ASM 22.The relay TRM 400 is intended for individual screw mounting.2Current time curvesThe current time curves give correlation between the tripping time and the multiplifcatorof the present current I e. They are presented for a cold initial state of therelay. For relays warmed by 1,0 x Ie load, the tripping times are lower by 25%.The curve 2 is given for 3-phase operation. The curve 1 is given for 2-phase operation.For the protection of a 1-phase, or DC motor, serial conection of the maincircuit of relays is necessary. For that connection the tripping curve 2 is valid.2/4Technical dataRelay typeTM 40 TRM 12 TRM 22 TRM 75Insulation rating Ui V 690 1000 690Permissible ambient temperature oC - 25 to +55Degree of protectionReleasetimeclassifcationIP00class 10 (release time 4 s ... 10 sat 7,2 x Ie from cold state)Temperature compensation + + + + +Phase failure protection by differential phase shift + + + + +Test button + + + + +Reset button + + + + +Switch position indicator + + + + +Changeover to hand or automatic reseting + + + + +Vibration resistance g 8 8 8 8 8TRM 400Main circuitrated operational current (AC 50 to 400 Hz or DC) A 38 16 30 80 400conductor cross - sectionsolid or stranded mm 2 2,5 - 10 2,5 - 6 2,5 - 6 2,5 - 35 120/24fnely stranded with end sleeveScrew/Screw headTightening torquemm 2Nm1,5 - 6M4/PZ21.61,5 - 4M4/PZ21.21,5 - 4M4/PZ21.21,5 - 25M62.5M10Power input per polemax. at setting range min. W/VA 0,9 0,9 0,9 2,6 5max. at setting range max. W/VA 2,25 2,25 2,25 4 12Auxiliary circuitnumber and type of contacts1 NO + 1 NC (galvanically separated)conductor cross - section2solid or stranded mm 2 x (1 - 2,5)fnely stranded with end sleeve mm 2 2 x (0,75 - 1,5)Screw/Screw headM3.5/PZ1Tightening torqueNm0.8rated thermal current Ith ; 35 o C A 6rated insulation voltage AC:unequal potential (NO + NC) V 400equal potential (NO + NC) V 690rated current Ie/AC15 for 24 V A 260 V A 1.5230 V A 1.15rated current400 V A 1.1500 V A 1Ie/DC13 for 24 V A 160 V A 0.4110 V A 0.22220 V A 0.1


2/52


22/6


6535GCNNTM 40 + CNN 25134 71TM 40 + CNN 32, 40 143.5 84.575,5 101 32.8 60-65 4.586 114 43.5 60-70 5TypeTRM 12 + CNM 9TRM 12 + CNM 12TRM 22 + CNM 16, 22, 30TRM 12 + CNB 9TRM 12 + CNB 12TRM 22 + CNB 16, 22, 3060Tip142 86.5127.3756590110AFTM 40EBC45DTypeF GTM 40 + CNN 9; 12; 18 132.2 71 74 101 31 60-65 4.523589.36645.281.4TM 40 + ASM 40TRM 7595 96 9798536402T14T250606T3112180178TRM 75 + ASM 752/7