10.08.2015 Views

Automatic Dielectric Constant Tan Delta & Resistivity Test Set

to download PDF - Drallim Industries

to download PDF - Drallim Industries

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

F E A T U R E SnnnnnnnnnnnnnFully automatic testing sequence controlled by amicro processor.Optional manual test sequencing.<strong>Automatic</strong> and continuous calibration ofResistance measuring circuit against two internalresistance standards.<strong>Automatic</strong> and continuous calibration of the C & DFmeasurement against internal reference capacitor.Internal AC voltage source of line frequency andsinusoidal wave shape.Internal DC voltage sources for (+) and (-) voltages.Windows software for interfacing to a PCRS232 Computer interface for downloading dataor control from a PC.Centronics parallel printer interface for direct testdata printout.Menu driven software operation.Stores up to 100 test results.Measures <strong>Resistivity</strong> applying (+) or (-) voltage.Open GND and Interlock protection for safety ofInstrument as well as the operator.BENEFITSn Eliminates manual balancing & reduces operator error.n Reduces the time required for each test sample.n Provides a high degree of repeatability.n Provides a printout, storage or export of test data.DESCRIPTIONThe Eltel Model ADTR-2K is a versatile <strong>Test</strong> <strong>Set</strong> usedfor measuring the <strong>Dielectric</strong> <strong>Constant</strong>, <strong>Tan</strong> <strong>Delta</strong> (DF),<strong>Resistivity</strong> of transformer oils & other electrical insulatingliquids or solid insulating materials in sheet form. TheADTR-2K is only the measuring instrument to test insulatingliquids, it should be used with a three-terminal oil test cell.A heater is required if the oil is to be tested at temperaturesspecified in international or national standards. A suitablesolid dielectric test cell is required for testing insulation insheet form.When excited with an AC source, the ADTR-2K measuresthe Voltage, Capacitance, <strong>Dielectric</strong> Loss and Frequency.Dissipation Factor (<strong>Tan</strong> <strong>Delta</strong>) or Power Factor iscalculated from the above measurements. To determinethe <strong>Dielectric</strong> <strong>Constant</strong> (∈), the measurements are carriedon an empty and a full test cell. The parameters of the testcell can also be entered manually, using the keypad.The operating procedure is menu driven & simple. The AC &DC test voltages are set using the front panel keypad. <strong>Test</strong>scan be programmed for the AC test between 200 to 2400volts and 100 to 1,000 volts for the DC test.After initial set-up, the oil test cell is filled with the oiltest sample & the test procedure is initiated. The test setperforms all the selected measurements automatically &the results are displayed on the front panel. The testresults can be transferred to a PC using the RS232 interface,printed using the Centronics parallel port, or stored in anon-volatile memory. The tests can also be repeated.S P E C I F I C A T I O N S<strong>Dielectric</strong> <strong>Constant</strong> & <strong>Tan</strong> <strong>Delta</strong><strong>Test</strong> Voltage : 0 - 2400 VAC in 1 volt stepsat line frequency.Accuracy : ± 1% of outputCapacitance : 0 - 200 …. 1600 pFAccuracy : ± 0.1% of reading ± 0.1pFBest Resolution : 0.01 pF<strong>Dielectric</strong> <strong>Constant</strong> : 1 to 20 when using a typicaloil testcell (C = ~70pF)Accuracy : ± 0.1%Resolution : 0.001Dissipation Factor (DF) : 0 - 1.000Accuracy : ± 1% of reading ± 0.0001Best Resolution : 0.00001 (10 -5 )<strong>Dielectric</strong> Loss : 0 - 10.00 wattsAccuracy : ± 1% of reading ±(10 -5 )Best Resolution : 0.001 milli watts (10 -6 watts)Cell <strong>Constant</strong> : Any cell acceptable; oil test cellwith 50 - 70 pF are ideal forOptimum performance.Resistance - <strong>Resistivity</strong><strong>Test</strong> voltage : 100 - 1000 VDC in 1 volt stepsAccuracy : ±1% of settingResistance Range : 10 6 to 10 12 OhmsResolution : 3 digitsAccuracy : ±2% of reading upto 1GΩ,increasing to ±10% at high end.<strong>Resistivity</strong> : 10 9 to 10 15 Ω - cm with atypical test cell of 1000 cm.Resolution : 3 digits.Accuracy : ±2% of reading at 10 9 – 10 13 Ω-cm±5% of reading at 10 13 – 10 14 Ω-cm±10% of reading above 10 14 Ω-cm2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!