Personen-, Produkt- und Raumschutzanlagen sowie House-in ...
Personen-, Produkt- und Raumschutzanlagen sowie House-in ...
Personen-, Produkt- und Raumschutzanlagen sowie House-in ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Personen</strong>-, <strong>Produkt</strong>- <strong>und</strong> <strong>Raumschutzanlagen</strong><br />
<strong>sowie</strong> <strong>House</strong>-<strong>in</strong>-<strong>House</strong>-Systeme<br />
für die Pharmazeutische Industrie<br />
Units for the Protection of Person, Product and Room as well<br />
as <strong>House</strong>-<strong>in</strong>-<strong>House</strong> Systems for the Pharmaceutical Industry
Trends <strong>und</strong> Zukunftstechnologien <strong>in</strong> der pharmazeutischen Industrie<br />
Trends and Future Techniques <strong>in</strong> the Pharmaceutical Industry<br />
Immer häufiger wird die Forderung nach kompletten,<br />
funktionsfertigen <strong>und</strong> wirtschaftlichen Anlagen <strong>und</strong> Units<br />
e<strong>in</strong>schließlich Planung <strong>und</strong> After-Sales-Service laut, die<br />
folgende Eigenschaften aufweisen:<br />
· <strong>Produkt</strong>schutz<br />
· <strong>Personen</strong>schutz<br />
· Re<strong>in</strong>raumqualität<br />
· Vermeidung von Kreuzkontam<strong>in</strong>ation<br />
· Abluftre<strong>in</strong>igung<br />
· GMP / FDA-Qualifizierung<br />
Die zwei Basissysteme<br />
Das WIBOjekt- <strong>und</strong> das WIBObarrier-System s<strong>in</strong>d die Verfahrenspr<strong>in</strong>zipien<br />
aller WIBO-Anlagen. Die Gr<strong>und</strong>lage stellt<br />
das WIBOjekt-Ejektorsystem dar.<br />
Mit dem Re<strong>in</strong>luftschleier als Trennung zwischen <strong>Produkt</strong><br />
<strong>und</strong> Person schützt es den Mitarbeiter <strong>und</strong> den Raum.<br />
Freiwerdende <strong>Produkt</strong>stäube oder Gase werden durch den<br />
Re<strong>in</strong>luftschleier sicher erfasst <strong>und</strong> der Absaugung<br />
zugeführt.<br />
Für E<strong>in</strong>satzfälle, bei denen besonderer Wert auf hohe Re<strong>in</strong>luftqualitäten<br />
im <strong>Produkt</strong>-/Arbeitsbereich gelegt wird,<br />
wurde das WIBObarrier-System entwickelt. Alle Vorteile des<br />
WIBOjekt-Systems wie <strong>Personen</strong>schutz, Raumschutz etc.<br />
s<strong>in</strong>d hier vere<strong>in</strong>t.<br />
Der Barrier-Re<strong>in</strong>luftschleier zieht auftretende Partikel<br />
sowohl von außen als auch von <strong>in</strong>nen mit <strong>und</strong> führt sie der<br />
darauf abgestimmten frontseitigen Absaugung zu.<br />
Während der <strong>Produkt</strong>ionsbereich mit der lam<strong>in</strong>aren Re<strong>in</strong>luft<br />
überströmt wird, schützt der Barrier-Schleier diesen<br />
Bereich vor Verwirbelungen, die durch die Bedienperson<br />
verursacht werden.<br />
2<br />
The demand is cont<strong>in</strong>ually <strong>in</strong>creas<strong>in</strong>g<br />
for complete, operative and economical<br />
systems and units, <strong>in</strong>clud<strong>in</strong>g plann<strong>in</strong>g<br />
and after-sale service which have<br />
the follow<strong>in</strong>g properties:<br />
· Protection of the product<br />
· Protection of the person<br />
· Clean-room quality<br />
· Avoidance of cross-contam<strong>in</strong>ation<br />
· Clean<strong>in</strong>g of exhaust air<br />
· GMP/FDA qualification<br />
The Two Basic Systems:<br />
The pr<strong>in</strong>ciples of process of all WIBO<br />
units are the WIBOjekt- and the<br />
WIBObarrier system. The basis is the<br />
WIBOjekt ejector system.<br />
With the clean-air curta<strong>in</strong> as separation<br />
between product and person it<br />
protects the product and the room.<br />
Product’s dusts or gases emitt<strong>in</strong>g are<br />
safely captured by the clean-air<br />
curta<strong>in</strong> and led to the extraction.<br />
For cases of application on which<br />
especially great importance is<br />
attached to the existence of high<br />
clean-room qualities <strong>in</strong> the productand<br />
work area, the WIBObarrier system<br />
has been developed. All advantages of<br />
the WIBOjekt system, such as protection<br />
of the person, room etc. are<br />
comb<strong>in</strong>ed.<br />
The barrier clean-air curta<strong>in</strong> pulls<br />
along the particles from outside as<br />
well as from <strong>in</strong>side and transfers them<br />
to the extraction which is well-suited<br />
to that and located on the front side.<br />
While the production area is overflowed<br />
by the lam<strong>in</strong>ated clean-air, the<br />
barrier clean-air curta<strong>in</strong> protects the<br />
production area also from air turbulence<br />
which is caused by the operat<strong>in</strong>g<br />
person.
WIBOjekt - WIBObarrier Vertikal<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-Systeme<br />
WIBOjekt-Arbeitstisch - WIBOjekt-<br />
Freiarbeitsplatz (FAP)<br />
<strong>Personen</strong>- <strong>und</strong> Raumschutz durch die<br />
<strong>in</strong>tegrierten WIBOjekt Re<strong>in</strong>luftschleier,<br />
die die luftgetragenen Schadstoffe<br />
sicher erfassen <strong>und</strong> gezielt der Absaugung<br />
zuführen.<br />
E<strong>in</strong>gebaut <strong>in</strong> k<strong>und</strong>enspezifisch konfigurierte<br />
Tische oder Freiarbeitsplätze<br />
garantieren die Re<strong>in</strong>luftschleier den<br />
ergonomischen <strong>und</strong> wirtschaftlichen<br />
Arbeitsplatz zum Wiegen, Umfüllen,<br />
Re<strong>in</strong>igen oder Probezug.<br />
WIBObarrier Vertikal: Die Zukunft<br />
Der Arbeitsplatz für den <strong>Produkt</strong>-,<br />
<strong>Personen</strong>- <strong>und</strong> Raumschutz mit<br />
<strong>in</strong>tegrierter Re<strong>in</strong>raumzone bis Klasse<br />
ISO 5 (A), der auch im „grauen/<br />
schwarzen“ Bereich aufgestellt werden<br />
kann. Zum Um- <strong>und</strong> Abfüllen, Veredeln,<br />
Montieren, Probezug.<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-Systeme<br />
Aus modularen, stabilen <strong>und</strong> selbsttragenden<br />
Wandpaneelen <strong>und</strong> Deckensystemen<br />
mit <strong>in</strong>tegrierten Lüftungskomponenten<br />
erstellen wir Ihre<br />
Re<strong>in</strong>räume, Personal- <strong>und</strong> Materialschleusen<br />
<strong>sowie</strong> Probezug-Kab<strong>in</strong>en -<br />
abgestimmt auf Ihren speziellen<br />
Bedarf.<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-System<br />
WIBOjekt Worktable – WIBOjekt-<br />
Free Workplace<br />
Protection of the person and the room<br />
by <strong>in</strong>tegrated WIBOjekt clean-air curta<strong>in</strong>s,<br />
which capture safely the air-borne<br />
pollutants and lead them precisely to<br />
the extraction.<br />
Installed <strong>in</strong> customer-specified configured<br />
tables or free workplaces, the<br />
clean-air curta<strong>in</strong>s guarantee an ergonomic<br />
and economical workplace for<br />
weigh<strong>in</strong>g, refill<strong>in</strong>g, clean<strong>in</strong>g or sampl<strong>in</strong>g.<br />
WIBObarrier Vertical: The Future<br />
The workplace for the protection of<br />
the product, person and room with<br />
<strong>in</strong>tegrated clean-room zone until<br />
class ISO 5 (A) which also can be <strong>in</strong>stalled<br />
<strong>in</strong> the “grey/black” area. Designed<br />
for refill<strong>in</strong>g, fill<strong>in</strong>g, ref<strong>in</strong>ement,<br />
assembl<strong>in</strong>g and sampl<strong>in</strong>g.<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-Systems<br />
We create your clean-rooms, personand<br />
material exit locks as well as sampl<strong>in</strong>g<br />
cab<strong>in</strong>s of modular, stable selfsupport<strong>in</strong>g<br />
panels and ceil<strong>in</strong>g systems<br />
with <strong>in</strong>tegrated ventilation components<br />
accord<strong>in</strong>g to your <strong>in</strong>dividual<br />
demands.<br />
3<br />
WIBOjekt-Arbeitstisch<br />
WIBOjekt-Worktable<br />
WIBOjekt-Freiarbeitsplatz<br />
WIBOjekt-Free Workplace<br />
WIBObarrier Vertikal
Isolator - Horizontal Barrier - Lam<strong>in</strong>ar-Flow -<br />
WIBOjekt economy<br />
Isolator<br />
WIBObarrier Horizontal<br />
Lam<strong>in</strong>ar-Flow<br />
WIBOjekt economy<br />
Isolator<br />
<strong>Personen</strong>-, <strong>Produkt</strong>- <strong>und</strong> Raumschutz.<br />
Kontrollierte Atmosphäre durch<br />
- Lam<strong>in</strong>ar-Flow Isolatoren<br />
- Unterdruck-Isolatoren – auch mit<br />
<strong>in</strong>tegrierten Filtersystemen<br />
- Spezielle Schleusen- <strong>und</strong> Andocksysteme<br />
WIBObarrier Horizontal<br />
<strong>Produkt</strong>-, Raum- <strong>und</strong> <strong>Personen</strong>schutz<br />
beim E<strong>in</strong>füllen/Entleeren von Inl<strong>in</strong>ern,<br />
Conta<strong>in</strong>ern, Big Bags etc. Horizontale<br />
<strong>und</strong> vertikale Re<strong>in</strong>luftschleier schirmen<br />
wie Barrieren den Schutz- <strong>und</strong><br />
Emissionsbereich vone<strong>in</strong>ander ab.<br />
Partikel von außen dr<strong>in</strong>gen nicht e<strong>in</strong><br />
(<strong>Produkt</strong>schutz), <strong>Produkt</strong>emissionen<br />
werden sicher erfasst <strong>und</strong> abgeführt<br />
(<strong>Personen</strong>- <strong>und</strong> Raumschutz, Vermeidung<br />
von Kreuzkontam<strong>in</strong>ation im<br />
Raum).<br />
Lam<strong>in</strong>ar-Flow Vertikalstrom-Module<br />
<strong>Produkt</strong>schutz. Durch k<strong>und</strong>enspezifisches<br />
Konfigurieren der Vertikalstrom-<br />
Module (auch über Eck <strong>und</strong> T-förmig)<br />
lassen sich sogar großflächige Re<strong>in</strong>raumzonen<br />
über Abfüll- <strong>und</strong> Verpackungsanlagen<br />
<strong>sowie</strong> Fertigungssektionen<br />
schaffen, die e<strong>in</strong> nicht emittierendes<br />
<strong>Produkt</strong> vor partikelbeladener<br />
Umgebungsluft schützen.<br />
WIBOjekt economy<br />
Sicherheitsabzüge für Gefahrstoffe, <strong>in</strong><br />
Laborausführung den Forderungen<br />
der EN 14175 entsprechend. Die<br />
WIBOjekt Re<strong>in</strong>luftschleier gewährleisten<br />
höchste Sicherheit u. a. durch e<strong>in</strong> sehr<br />
robustes Rückhaltevermögen auch bei<br />
voll geöffnetem Frontschieber.<br />
4<br />
Isolator<br />
Protection of person, product and<br />
room. Controlled atmosphere by<br />
- Lam<strong>in</strong>ar Flow Isolators<br />
- Underpressure Isolators – also with<br />
<strong>in</strong>tegrated filter systems<br />
- Special lock- and dock<strong>in</strong>g systems<br />
WIBObarrier Horizontal<br />
Protection of product, room and<br />
person on fill<strong>in</strong>g/empty<strong>in</strong>g of <strong>in</strong>l<strong>in</strong>ers,<br />
conta<strong>in</strong>ers, big bags etc. Horizontal<br />
and vertical clean-air curta<strong>in</strong>s shield<br />
the protection and emission area<br />
aga<strong>in</strong>st eachother like barriers.<br />
Particles from outside do not get <strong>in</strong><br />
(protection of product), product<br />
emissions are captured safely and led<br />
off (protection of person and room,<br />
avoidance from cross contam<strong>in</strong>ation<br />
<strong>in</strong> the room).<br />
Lam<strong>in</strong>ar Flow Vertical Flow Modules<br />
Protection of product. By a customerspecified<br />
configuration of the vertical<br />
flow modules (also across corners<br />
and t-shaped), even large surface<br />
clean-room zones can be created<br />
above fill<strong>in</strong>g- and pack<strong>in</strong>g units as well<br />
as manufactur<strong>in</strong>g sections, which protect<br />
the non-emitt<strong>in</strong>g product from<br />
the particle charged ambient air.<br />
WIBOjekt economy<br />
Safety fume hoods for hazardous substances,<br />
<strong>in</strong> laboratory design correspond<strong>in</strong>g<br />
to the demands of the standard<br />
EN 14175. The WIBOjekt clean-air<br />
curta<strong>in</strong>s guarantee high rate safety<br />
among others by a robust retention<br />
capacity also <strong>in</strong> case of a completely<br />
opened front shutter.
Wiege- <strong>und</strong> Umfülltische<br />
Weigh<strong>in</strong>g- and Refill<strong>in</strong>g Tables<br />
Wiege- <strong>und</strong> Umfülltische mit dem<br />
WIBOjekt System schützen den Mitarbeiter<br />
<strong>und</strong> den Raum gleichermaßen<br />
sicher durch den Re<strong>in</strong>luftschleier.<br />
Varianten von der e<strong>in</strong>fachen Anlage<br />
bis zur Komfortanlage mit mehreren<br />
e<strong>in</strong>gebauten Waagen, Term<strong>in</strong>al <strong>und</strong><br />
<strong>in</strong>tegriertem Bildschirm s<strong>in</strong>d möglich.<br />
Die Aufteilungen <strong>und</strong> Größen s<strong>in</strong>d<br />
genauso variabel wie die Ausstattungen.<br />
Für den E<strong>in</strong>bau von Versuchs- <strong>und</strong><br />
Prüfanlagen eignen sich diese Ausführungen<br />
ebenfalls sehr gut. E<strong>in</strong>gebaute<br />
Abluftfilter (s. Seite 18) sorgen dafür,<br />
dass ke<strong>in</strong>e Abluftleitungen <strong>sowie</strong> andere<br />
Raumbereiche kontam<strong>in</strong>iert werden<br />
<strong>und</strong> schaffen Sicherheit gegen<br />
Kreuzkontam<strong>in</strong>ationen. Ger<strong>in</strong>ge Betriebs-<br />
<strong>sowie</strong> Re<strong>in</strong>igungs- <strong>und</strong> Validierungs-/Qualifizierungskosten.<br />
Weigh<strong>in</strong>g- and refill<strong>in</strong>g-tables with the<br />
WIBOjekt system protect the employee<br />
and the room equally safely by the<br />
clean air curta<strong>in</strong>.<br />
Variants rang<strong>in</strong>g from a simple plant<br />
to a sophisticated <strong>in</strong>stallation with<br />
several built-<strong>in</strong> scales, term<strong>in</strong>al and<br />
<strong>in</strong>tegrated screen are available. Both,<br />
the divisions and the sizes are as variable<br />
as the equipments.<br />
These types are also very well suitable<br />
for the <strong>in</strong>stallations of test<strong>in</strong>g and<br />
analys<strong>in</strong>g plants. Integrated exhaust<br />
air filters (s. page 18) make sure that<br />
exhaust air pipes and other areas of<br />
the environment will not be contam<strong>in</strong>ated<br />
and so prevent from cross contam<strong>in</strong>ation.<br />
Low operat<strong>in</strong>g, clean<strong>in</strong>g and<br />
validation/qualification costs.<br />
5<br />
WIBOjekt Arbeitstisch<br />
WIBOjekt Worktable
Freiarbeitsplatz mit <strong>in</strong>tegrierter Schadstoff-Ejektor-Absaugung<br />
Free Workplace with Integrated Pollutant Ejector Extraction<br />
Die Freiarbeitsplätze s<strong>in</strong>d Arbeitsplätze,<br />
<strong>in</strong> denen nahezu alle Tätigkeiten<br />
frei positioniert durchgeführt werden<br />
können. Im Verhältnis zu normalen<br />
Arbeitskab<strong>in</strong>en benötigen Freiarbeitsplätze<br />
wesentlich ger<strong>in</strong>gere Luftmengen.<br />
Frischluft-Umluftbetrieb ist<br />
e<strong>in</strong>stellbar. In den E<strong>in</strong>satzbereichen<br />
Abfüllen, Umfüllen, Wiegen, Horden<br />
be-/entladen bei E<strong>in</strong>bauten etc. hat<br />
sich der Freiarbeitsplatz hervorragend<br />
bewährt.<br />
<strong>Produkt</strong>- <strong>und</strong> <strong>Personen</strong>schutz, leichte<br />
Re<strong>in</strong>igung, Validierung/Qualifizierung<br />
<strong>sowie</strong> niedrige Betriebskosten eröffnen<br />
diesen Anlagen weite <strong>und</strong> flexible<br />
E<strong>in</strong>satzbereiche im Pharma- <strong>und</strong><br />
Chemiebereich.<br />
Durch E<strong>in</strong>baumöglichkeiten von z.B.<br />
Abfülltrichtern <strong>und</strong> Rohrleitungen<br />
s<strong>in</strong>d sie ideal für Abfüllvorgänge aus<br />
Mischern, Dissolvern, etc. geeignet.<br />
E<strong>in</strong>gebaute Abluftfilter (Seite 18) sorgen<br />
dafür, dass ke<strong>in</strong>e Abluftleitungen<br />
<strong>sowie</strong> andere Raumbereiche kontam<strong>in</strong>iert<br />
werden <strong>und</strong> br<strong>in</strong>gen Sicherheit<br />
gegen Kreuzkontam<strong>in</strong>ation. Ger<strong>in</strong>ge<br />
Betriebs-, Re<strong>in</strong>igungs- <strong>und</strong> Validierungs-/Qualifizierungskosten.<br />
WIBOjekt-Freiarbeitsplatz<br />
WIBOjekt - Free Workplace<br />
6<br />
Free workplaces are workplaces where almost all works can<br />
be carried out at any position <strong>in</strong>side the workplace. In<br />
contrast to normal work cab<strong>in</strong>s, WIBOjekt free workplaces<br />
need considerably less air volumes. Operation with fresh<br />
air-circulation air is adjustable. In the area of fill<strong>in</strong>g, refill<strong>in</strong>g,<br />
weigh<strong>in</strong>g, load<strong>in</strong>g and unload<strong>in</strong>g of metal racks with medical<br />
products, <strong>in</strong> case of <strong>in</strong>stallations etc. the free workplace has<br />
brilliantly proven its quality.<br />
Protection of product and person, easy clean<strong>in</strong>g, validation/<br />
qualification and low operat<strong>in</strong>g costs enable a wide and<br />
flexible range of operation of these <strong>in</strong>stallations <strong>in</strong> the<br />
pharmaceutical and chemical area.<br />
Hoppers, pipes etc. can be <strong>in</strong>tegrated <strong>in</strong>to the hood area<br />
which makes the free workplaces useable for work<strong>in</strong>g<br />
processes <strong>in</strong>clud<strong>in</strong>g mixers, dissolvers etc.<br />
Integrated exhaust air filters (s. page 18) make sure that<br />
exhaust air pipes and other areas of the environment will<br />
not be contam<strong>in</strong>ated and give safety aga<strong>in</strong>st cross contam<strong>in</strong>ation.<br />
Low operat<strong>in</strong>g, clean<strong>in</strong>g- and validation/qualification<br />
costs.
WIBObarrier Vertikal - Arbeitsplatz mit Re<strong>in</strong>raumzone<br />
WIBObarrier Vertical - Workplace with Clean-Roomzone<br />
Viele Arbeiten <strong>und</strong> Verfahren können<br />
<strong>in</strong> kle<strong>in</strong>en Bereichen erfolgen. Es genügt,<br />
wenn der eigentliche Arbeitsbereich<br />
als Re<strong>in</strong>raumzone gebaut ist. Auf<br />
teure Re<strong>in</strong>räume, hohe Re<strong>in</strong>heitsklassen,<br />
E<strong>in</strong>-/ Ausschleusen, häufiges<br />
Umziehen, auf all das kann oft verzichtet<br />
werden.<br />
Die Arbeitsplätze können <strong>in</strong> „Grau“oder<br />
„Schwarzzonen“, aber auch zur<br />
Erreichung e<strong>in</strong>er höheren Schutzklasse<br />
<strong>in</strong> bereits vorhandenen Re<strong>in</strong>räumen<br />
aufgestellt werden. Der Mitarbeiter<br />
wird durch die Re<strong>in</strong>luftschleier<br />
des Barrier-Systems (siehe Pr<strong>in</strong>zip)<br />
vom Arbeitsbereich abgeschirmt.<br />
Re<strong>in</strong>luft-Quellauslässe sorgen im Bereich<br />
h<strong>in</strong>ter dem Re<strong>in</strong>luftschleier für<br />
entsprechende Re<strong>in</strong>raumqualität.<br />
Messungen beweisen: MP1: Re<strong>in</strong>raumklassen<br />
„A“ <strong>und</strong> besser. MP2: im Umfeld<br />
bef<strong>in</strong>den sich mehrere Millionen<br />
Partikel. Partikel, die durch Arbeiten<br />
oder H<strong>in</strong>e<strong>in</strong>greifen e<strong>in</strong>gebracht werden,<br />
werden i.d.R. durch den Barrier-<br />
Re<strong>in</strong>luftschleier erfaßt oder <strong>in</strong> Sek<strong>und</strong>en<br />
abgeführt. Arbeitsbewegungen<br />
stören das System kaum. Der Arbeitsplatz<br />
kann als autarke Anlage unabhängig<br />
von der vorhandenen Lüftung<br />
konzipiert werden.<br />
Die Lüftungs-, Regelungs- <strong>und</strong> Überwachungstechnik<br />
ist <strong>in</strong>tegriert. Mit/<br />
ohne Abluftfilter. Bedienung über Folientastatur.<br />
Schnittstellen s<strong>in</strong>d vorhanden.<br />
Als Tisch oder E<strong>in</strong>stellbereich<br />
lieferbar.<br />
WIBObarrier Vertikal<br />
WIBObarrier Vertical<br />
Messmethode-<strong>Produkt</strong>schutzfaktor<br />
Measur<strong>in</strong>g Method Product Protection Factor<br />
7<br />
Many works and procedures can be made <strong>in</strong> small areas. It<br />
is sufficient if only the real work area is constructed as<br />
clean-room zone. Often it can be done without expensive<br />
clean rooms, high cleanness classes, sluic<strong>in</strong>g <strong>in</strong> and out,<br />
frequent chang<strong>in</strong>g of clothes.<br />
The workplaces can be <strong>in</strong>stalled <strong>in</strong><br />
grey or black zones but also <strong>in</strong><br />
already exist<strong>in</strong>g clean rooms to<br />
achieve a higher protection class.<br />
The employee is shielded from the<br />
work area by the clean-air curta<strong>in</strong>s of<br />
the barrier system (see pr<strong>in</strong>ciple<br />
draw<strong>in</strong>g). Clean-air source outlets<br />
ensure correspond<strong>in</strong>g clean-room<br />
quality <strong>in</strong> the area beh<strong>in</strong>d the cleanair<br />
curta<strong>in</strong>.<br />
Measurements prove: MP1: cleanroom<br />
classes “A” and better. MP2: <strong>in</strong> the environment are<br />
several millions of particles. As a rule, particles exist<strong>in</strong>g by<br />
works or grabb<strong>in</strong>g <strong>in</strong>to the work area are captured by the<br />
barrier clean-air curta<strong>in</strong> or led off with<strong>in</strong> seconds. Work<strong>in</strong>g<br />
movements disturb hardly the system. The workplace can<br />
be designed as self-sufficient unit <strong>in</strong>dependent of the<br />
exist<strong>in</strong>g ventilation.<br />
The ventilation, control and monitor<strong>in</strong>g technology is<br />
<strong>in</strong>tegrated. With/without exhaust air filter. Operation by<br />
foil keyboard. Interfaces are exist<strong>in</strong>g. Available as table or<br />
as area for putt<strong>in</strong>g <strong>in</strong> of e.g. barrels.<br />
Messmethode-<strong>Personen</strong>schutzfaktor<br />
Measur<strong>in</strong>g Method Person Protection Factor
WIBObarrier Horizontal<br />
... beim Befüllen von Inl<strong>in</strong>ern, Conta<strong>in</strong>ern,<br />
Big Bags etc.<br />
Die Tatsache, dass e<strong>in</strong>e Kette immer nur so gut ist, wie das<br />
schwächste Glied, wird besonders beim An- <strong>und</strong> Abkoppeln<br />
offensichtlich. Hier werden trotz moderner Abfülltechnik<br />
Emissionen frei bzw. das <strong>Produkt</strong> ist nicht sicher geschützt.<br />
Langjährige Erfahrungen <strong>in</strong> der Ejektor- <strong>und</strong> Luftschleiertechnik<br />
bilden die Gr<strong>und</strong>lage dieser Lösung. Die <strong>in</strong>tegrierten<br />
senkrechten <strong>und</strong> waagerechten Re<strong>in</strong>luftschleier schirmen<br />
wie Barrieren den Schutz-<strong>und</strong> Emissionsbereich ab.<br />
Hohe Richtungsstabilität wird durch Konstruktion <strong>sowie</strong><br />
Komb<strong>in</strong>ation der Düsen, Regler <strong>und</strong> Drücke erreicht. Quellluft<br />
<strong>in</strong> Re<strong>in</strong>raumqualität strömt <strong>in</strong>nerhalb des Schutzbereiches<br />
nach. Partikel von außen dr<strong>in</strong>gen nicht e<strong>in</strong>. <strong>Produkt</strong>emissionen<br />
werden sicher erfaßt <strong>und</strong> abgeführt. Die Modulbauweise<br />
erlaubt e<strong>in</strong>e Anpassung an nahezu alle Situationen.<br />
Auch <strong>in</strong> schwenkbarer <strong>und</strong> Ex-Ausführung lieferbar. Betriebsweise<br />
<strong>in</strong> Frisch- oder Umluftbetrieb. Qualifizierbar,<br />
GMP/FDA-gerecht.<br />
8<br />
... on fill<strong>in</strong>g of <strong>in</strong>l<strong>in</strong>ers,<br />
conta<strong>in</strong>ers, big bags etc.<br />
The fact that a cha<strong>in</strong> is always as good<br />
as its weakest l<strong>in</strong>k becomes especially<br />
obvious at the coupl<strong>in</strong>g and disconnect<strong>in</strong>g.<br />
Here, despite modern fill<strong>in</strong>g<br />
techniques, emissions are released<br />
resp. the product is not protected<br />
safely.<br />
Many years of experience <strong>in</strong> the ejector<br />
and air curta<strong>in</strong> technology formed<br />
the basic of this solution. The <strong>in</strong>tegrated<br />
vertical and horizontal clean-air<br />
curta<strong>in</strong>s shield the protection and<br />
emission area like barriers.<br />
High stability of direction is achieved<br />
by construction as well as comb<strong>in</strong>ation<br />
of the nozzles, regulator and<br />
pressures. Source air <strong>in</strong> clean-room<br />
quality comes gush<strong>in</strong>g after <strong>in</strong>side the<br />
protection area. Particles from outside<br />
do not get <strong>in</strong>. Product emissions are<br />
captured safely and led off. The modular<br />
construction admits an adaptation<br />
to nearly all situations.<br />
Available also <strong>in</strong> swivell<strong>in</strong>g and explosion-proof<br />
design. Operation with<br />
fresh or circulat<strong>in</strong>g air. Qualification is<br />
possible, the unit meets the demands<br />
of the GMP/FDA guidel<strong>in</strong>es.
Modulares <strong>House</strong>-<strong>in</strong>-<strong>House</strong> System<br />
Modular <strong>House</strong>-<strong>in</strong>-<strong>House</strong> System<br />
Das modulare WIBOlifescience<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong> System:<br />
- stabiles, selbsttragendes Paneelen- <strong>und</strong> Deckensystem<br />
mit <strong>in</strong>tegrierten Lüftungskomponenten<br />
- optimale E<strong>in</strong>b<strong>in</strong>dung der WIBOjekt-Systemanlagen zur<br />
sicheren Erfassung freiwerdender Stäube <strong>und</strong> Gase<br />
- die Module des <strong>House</strong>-<strong>in</strong>-<strong>House</strong>-Systems s<strong>in</strong>d optimal<br />
aufe<strong>in</strong>ander abgestimmt <strong>und</strong> fast beliebig mite<strong>in</strong>ander<br />
komb<strong>in</strong>ierbar<br />
E<strong>in</strong>fache Demontage von Modulen. Auch bei fertiggestellter<br />
Anlage ist die Entnahme e<strong>in</strong>zelner Paneelen noch<br />
problemlos möglich.<br />
Pharmagerechte Ausführung. Alle Module verfügen<br />
über vollständig glatte Edelstahl- bzw. Glasoberflächen. So<br />
wird e<strong>in</strong>e schnelle <strong>und</strong> leichte Re<strong>in</strong>igung der Anlage ermöglicht.<br />
Errichtung im Achsraster. M<strong>in</strong>imierung der Fugenlänge<br />
durch Errichtung der Kab<strong>in</strong>e im Achsraster ohne zusätzliche<br />
tragende Konstruktionen.<br />
Sehr stabile Ausführung. Sandwichbauweise mit <strong>in</strong>nenliegender<br />
Alum<strong>in</strong>ium-Trägerkonstruktion, schall-<strong>und</strong> wärmeisolierend.<br />
Alle diese Komponenten für:<br />
- die Raumerstellung (Paneelen, Türen, Decken usw.)<br />
- die Luftkonditionierung (Zuluft/Umluftanlagen)<br />
- die Re<strong>in</strong>raumtechnik (endständige Filter)<br />
- die Vermeidung von Kreuzkontam<strong>in</strong>ationen<br />
- die produktionsgerechten Arbeitsplätze mit<br />
WIBOlifescience<br />
- die Abluftre<strong>in</strong>igung, Filtration, Abluftanlagen<br />
- die Steuerungs- <strong>und</strong> Überwachungsanlagen usw.<br />
wurden <strong>in</strong> das WIBOlifescience Programm <strong>in</strong>tegriert.<br />
9<br />
The modular WIBOlifescience<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong> System:<br />
- stable self-support<strong>in</strong>g panel and ceil<strong>in</strong>g system with<br />
<strong>in</strong>tegrated ventilation components<br />
- optimal <strong>in</strong>tegration of the WIBOjekt system units for safe<br />
capture of airborne dusts and gases<br />
- the modules of the <strong>House</strong>-<strong>in</strong>-<strong>House</strong> System are perfectly<br />
match<strong>in</strong>g with each other and offer nearly any<br />
comb<strong>in</strong>ation.<br />
Easy dismantl<strong>in</strong>g of modules. Even if the <strong>in</strong>stallation has<br />
been f<strong>in</strong>ished, the removal of particular panels is possible<br />
without problems.<br />
Design suitable for use <strong>in</strong> pharmaceutical <strong>in</strong>dustry.<br />
All modules have completely smooth surfaces of sta<strong>in</strong>less<br />
steel or glass. Thus, a fast and efficient clean<strong>in</strong>g of the<br />
<strong>in</strong>stallation is possible.<br />
Axle-lattice construction. M<strong>in</strong>imization of gaps by<br />
construction of the cab<strong>in</strong> <strong>in</strong> axle-lattice construction<br />
without additional support<strong>in</strong>g constructions.<br />
Very stable design. Sandwich-construction with <strong>in</strong>ner<br />
alum<strong>in</strong>ium support<strong>in</strong>g construction, so<strong>und</strong> and heat<br />
<strong>in</strong>sulat<strong>in</strong>g.<br />
All these components for:<br />
- construction of rooms (panels, doors, ceil<strong>in</strong>gs, etc.)<br />
- air condition<strong>in</strong>g (supply/circulat<strong>in</strong>g air units)<br />
- clean-room technology (f<strong>in</strong>al filters)<br />
- avoidance of cross contam<strong>in</strong>ation<br />
- workplaces with WIBOlifescience, match<strong>in</strong>g production<br />
processes<br />
- clean<strong>in</strong>g of exhaust air, filtration, exhaust air units<br />
- control and monitor<strong>in</strong>g units, etc.<br />
have been <strong>in</strong>tegrated <strong>in</strong>to the WIBOlifescience programme.
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-System<br />
Aufgabenstellung:<br />
Aufgabenstellung:<br />
In „schwarzen“ Fertigungsräumen<br />
werden Implantate (Hüft- <strong>und</strong> Kniegelenke<br />
etc.) spangebend aus Edelstahl<br />
hergestellt. Die <strong>Produkt</strong>ionssektionen<br />
- von der Re<strong>in</strong>igung bis zur vakuumverpackten<br />
Ausschleusung - erfolgt <strong>in</strong><br />
verketteten Weiss GWE-Anlagen (s. Ablaufskizze).<br />
Die e<strong>in</strong>zelnen Anlagen s<strong>in</strong>d:<br />
1. Gr<strong>und</strong>wäsche <strong>in</strong> lösemittelhaltiger<br />
Substanz – <strong>Personen</strong>schutz <strong>in</strong> Eco-<br />
Box EB 12N1<br />
2. Fe<strong>in</strong>re<strong>in</strong>igung im Ultraschall-Bad –<br />
<strong>Produkt</strong>schutz im Vertikalstrom-<br />
Barrier VSB 1208<br />
3. E<strong>in</strong>schleusung zum Barrier <strong>in</strong> das<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-System – Durchreicheschleuse<br />
DRS 2<br />
4. Vakuume<strong>in</strong>schweißung unter Re<strong>in</strong>raumklasse<br />
3 bei permanenter<br />
Partikelmessung (zul. max. 10 Partikel)<br />
– Barrier BA 200 mit Klasse 3<br />
am Arbeitsplatz aufgestellt im<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-System mit <strong>Personen</strong>-<br />
<strong>und</strong> Materialschleuse<br />
Task:<br />
Implants (hip- and knee jo<strong>in</strong>ts etc.) are<br />
produced and cutted of sta<strong>in</strong>less steel<br />
<strong>in</strong> “black” manufactur<strong>in</strong>g rooms.<br />
The production’s sections – from the<br />
clean<strong>in</strong>g to vacuum packed sluic<strong>in</strong>gout<br />
– take place <strong>in</strong> l<strong>in</strong>ked units of<br />
Weiss GWE (cf. illustration).<br />
The <strong>in</strong>dividual units are:<br />
1. Basic clean<strong>in</strong>g <strong>in</strong> solvent-based<br />
substance – protection of person <strong>in</strong><br />
Eco box EB 12N1<br />
2. F<strong>in</strong>e clean<strong>in</strong>g <strong>in</strong> ultrasonic bath –<br />
protection of product <strong>in</strong> vertical<br />
flow barrier VSB 1208<br />
3. Sluic<strong>in</strong>g-<strong>in</strong> to the barrier <strong>in</strong>to the<br />
<strong>House</strong>-<strong>in</strong>-<strong>House</strong>-System – lock for<br />
pass<strong>in</strong>g through of material DRS 2<br />
4. Vacuum heat-ceil<strong>in</strong>g <strong>und</strong>er cleanroom<br />
class 3 with permanent<br />
particle measur<strong>in</strong>g (admissible<br />
max. 10 particles) – Barrier BA 200<br />
with class 3 at the workplace,<br />
<strong>in</strong>stalled <strong>in</strong> a <strong>House</strong>-<strong>in</strong>-<strong>House</strong>-<br />
System with person- and material<br />
locks.<br />
10<br />
3<br />
3
<strong>Personen</strong>- <strong>und</strong> Materialschleusen<br />
Person- and Material Locks<br />
Das WIBOlifescience Modulsystem schafft flexible <strong>und</strong><br />
kostengünstige <strong>Personen</strong>- <strong>und</strong> Materialschleusen<br />
Die Anforderungen an Schleusen werden immer umfangreicher.<br />
EU-Richtl<strong>in</strong>ien, GMP <strong>und</strong> FDA Forderungen <strong>sowie</strong><br />
deren Umsetzung br<strong>in</strong>gen sie mit sich.<br />
Räume mit 10- oder 20-fachem Luftwechsel oder auch mit<br />
e<strong>in</strong>igen größeren Luftdüsen erfüllen diese Anforderungen<br />
<strong>in</strong> der Regel nicht mehr. E<strong>in</strong>e gezielte Luftströmung ist gefordert.<br />
Das WIBOjekt Luft-Gegenstrompr<strong>in</strong>zip trägt die Fremdstoffe<br />
sicher vom Re<strong>in</strong>bereich <strong>und</strong> der Duschzone zu der Absaugwand.<br />
Alle Re<strong>in</strong>igungs- <strong>und</strong> Wartungsarbeiten können vom<br />
Innenraum aus durchgeführt werden.<br />
Unterschiedliche Module erfüllen nahezu alle Wünsche <strong>in</strong><br />
Bezug auf Geometrie <strong>und</strong> Ausstattung. Mit den Prozessorsteuerungen<br />
s<strong>in</strong>d alle Ablauf- <strong>und</strong> sicherheitstechnischen<br />
Überwachungen realisierbar.<br />
11<br />
The WIBOlifescience module<br />
system leads to flexible and Iowcost<br />
person- and material locks<br />
Due to standards set by the EC, GMP<br />
and FDA, locks <strong>in</strong>creas<strong>in</strong>gly have to<br />
meet more and more complex requirements.<br />
Rooms with a 10 or 20 times air change<br />
or with some bigger air nozzles usually<br />
do not meet these standards. A precise<br />
airflow is required.<br />
The WIBOjekt air-counterflow pr<strong>in</strong>ciple<br />
securely transfers contam<strong>in</strong>ation<br />
from clean and shower area to the<br />
filters. All clean<strong>in</strong>g and ma<strong>in</strong>tenance<br />
can be carried out from the <strong>in</strong>side.<br />
Different modules practically fulfill all<br />
wishes regard<strong>in</strong>g geometrical design<br />
and equipment. Processor controls<br />
realize all controls of process and<br />
safety technology.
Probenahme- <strong>und</strong> Probezugkab<strong>in</strong>en<br />
Sampl<strong>in</strong>g Cab<strong>in</strong>s<br />
Die Qualitätskontrolle hat e<strong>in</strong>en hohen Stellenwert. Hier<br />
werden Geb<strong>in</strong>de geöffnet, <strong>und</strong> für e<strong>in</strong>en GMP/FDA-gerechten<br />
Ablauf müssen bei der Probenahme Person <strong>und</strong> <strong>Produkt</strong><br />
geschützt werden. Es s<strong>in</strong>d Raumkontam<strong>in</strong>ationen zu verh<strong>in</strong>dern,<br />
Ab- <strong>und</strong> Umluft entsprechend zu filtern, leichte<br />
Re<strong>in</strong>igung <strong>und</strong> Vermeidung von Kreuzkontam<strong>in</strong>ationen<br />
sicherzustellen. Probenahmen werden daher zunehmend <strong>in</strong><br />
Zentralen durchgeführt. Das WIBOlifescience Programm<br />
bietet komplette Probenahme- <strong>und</strong> Probezugkab<strong>in</strong>en.<br />
Und das <strong>in</strong>tegrierte WIBObarrier System stellt sowohl den<br />
<strong>Personen</strong>- als auch den <strong>Produkt</strong>schutz sicher.<br />
Im Gegensatz zum Lam<strong>in</strong>ar-Flow System werden freiwerdende<br />
Emissionen mit dem WIBObarrier Re<strong>in</strong>luftschleier<br />
trotz ger<strong>in</strong>ger Luftmengen wie mit e<strong>in</strong>em Magnet sicher zur<br />
Absaugöffnung geführt. Der <strong>Produkt</strong>verlust <strong>sowie</strong> die<br />
Filterkosten werden drastisch reduziert.<br />
- Kab<strong>in</strong>en aus Sandwich-Edelstahlpaneelen<br />
- Schnelle Montage durch Modulbauweise<br />
- Zuluft über endständige Filter H 13<br />
- wahlweise Umluft/Fortluft- oder e<strong>in</strong>stellbarer Mischluftbetrieb<br />
- Beleuchtung <strong>in</strong> die Haube <strong>in</strong>tegriert<br />
- Hochleistungsfilter an der Absaugstelle<br />
- von oben angeströmt, Vermeidung von Kreuzkontam<strong>in</strong>ationen,<br />
selbstnachspannende Dichtung<br />
- Prüfvorrichtungen für DEHS-Tests<br />
- Filter berührungsfrei von vorne wechselbar<br />
Steuerungs- <strong>und</strong> Sicherheitsüberwachung für Unter- oder<br />
Überdruckbetrieb.<br />
WIBObarrier<br />
12<br />
Quality control has got a high status. Conta<strong>in</strong>ers and<br />
receptacles are opened. Thus, <strong>in</strong> order to guarantee a GMP/<br />
FDA match<strong>in</strong>g process, person and product have to be<br />
protected dur<strong>in</strong>g sampl<strong>in</strong>g. Contam<strong>in</strong>ation of the room<br />
must be avoided, exhaust and circulat<strong>in</strong>g air have to be<br />
filtered accord<strong>in</strong>gly, easy clean<strong>in</strong>g and the avoidance of<br />
cross contam<strong>in</strong>ation have to be guaranteed. Therefore,<br />
sampl<strong>in</strong>gs are <strong>in</strong>creas<strong>in</strong>gly done <strong>in</strong> central work stations.<br />
The WIBOlifescience programme offers complete cab<strong>in</strong>s for<br />
sampl<strong>in</strong>g. Protection of the person and the programme is<br />
guaranteed by the <strong>in</strong>tegrated WIBObarrier system.<br />
Unlike the Lam<strong>in</strong>ar Flow system, emissions which have got<br />
free, are guided by the WIBObarrier clean air curta<strong>in</strong> like by a<br />
magnet to the extraction open<strong>in</strong>g. This process requires<br />
only small amounts of air. Thus, the loss of product as well<br />
as the costs for filters are drastically reduced.<br />
- The cab<strong>in</strong>s consist of sandwich panels of sta<strong>in</strong>less steel<br />
- Quick assembly by module method of construction<br />
- Supply air via ultimate filters H 13<br />
- Choice of operation with circulat<strong>in</strong>g, total exhaust or<br />
mixed air<br />
- Light<strong>in</strong>g <strong>in</strong>tegrated <strong>in</strong>to the hood<br />
- High efficiency filters at the extraction flown<br />
from above, avoidance of cross contam<strong>in</strong>ation, selftighten<strong>in</strong>g<br />
gasket<br />
- Test <strong>in</strong>stallations for DEHS tests<br />
- Filters can be replaced from the front side without contact<br />
Control and safety monitor<strong>in</strong>g for operation with negative or<br />
excess pressure.
Probenahme- <strong>und</strong> Probezugkab<strong>in</strong>en<br />
Sampl<strong>in</strong>g Cab<strong>in</strong>s<br />
WIBObarrier - die effiziente Anlagenkonfiguration für<br />
den <strong>Produkt</strong>- <strong>und</strong> <strong>Personen</strong>schutz bei der Probenahme<br />
Beispiel 1:<br />
Der Barrier wird, mit Filtertechnik <strong>in</strong> der Rückwand, <strong>in</strong> Umluft<br />
betrieben <strong>und</strong> als steckerfertige E<strong>in</strong>heit direkt <strong>in</strong> der Lagerhalle<br />
aufgestellt. Die Paletten werden zum Probezug frontseitig<br />
e<strong>in</strong>gefahren.<br />
Luftqualitäten:<br />
- Im Aufstellungsraum/Lagerhalle<br />
(„schwarzer Bereich“) ca. 1,5 Mill. cft<br />
- Über dem <strong>Produkt</strong> im Barrier ISO-Klasse 8 <strong>und</strong> besser<br />
(Klasse 100.000)<br />
Beispiel 2:<br />
Der Barrier wird <strong>in</strong> Fortluft betrieben. Die E<strong>in</strong>heit wurde im<br />
Re<strong>in</strong>raum Klasse 100.000 (ISO 8) direkt an die Lagerhalle<br />
angrenzend aufgestellt. Von der Lagerhalle aus („schwarzer<br />
Bereich“) werden die Paletten oder E<strong>in</strong>zelgeb<strong>in</strong>de stirnseitig<br />
über e<strong>in</strong>e Rollenbahn <strong>in</strong> den Barrier e<strong>in</strong>gefahren. Die Hubtür<br />
des Barriers schottet den Re<strong>in</strong>raum zur Lagerhalle ab, so<br />
dass auf e<strong>in</strong>e Materialschleuse verzichtet werden konnte. Im<br />
Barrier werden die unterschiedlich hohen Geb<strong>in</strong>de mit e<strong>in</strong>em<br />
Hubtisch <strong>in</strong> e<strong>in</strong>e ergonomische Probenahmeposition<br />
angehoben.<br />
Luftqualitäten:<br />
- In der Lagerhalle („schwarzer Bereich“) ca. 1,5 Mill. cft<br />
- Im Aufstellungsraum ISO-Klasse 8 (Klasse 100.000)<br />
- Im Barrier über dem <strong>Produkt</strong> ISO-Klasse 6 (Klasse 1.000)<br />
Beispiel 1:<br />
Example 1:<br />
13<br />
WIBObarrier - The Efficient Configuration of Units for<br />
The Protection of Products and Persons on Sampl<strong>in</strong>g<br />
Example 1:<br />
The Barrier is operated with circulat<strong>in</strong>g air us<strong>in</strong>g filter<br />
technology <strong>in</strong> the rear wall and is <strong>in</strong>stalled directly <strong>in</strong> the<br />
warehouse ready to plug <strong>in</strong>. For sampl<strong>in</strong>g the pallets are<br />
transported <strong>in</strong>to the barrier from the front side.<br />
Air qualities:<br />
- In the <strong>in</strong>stallation room/warehouse<br />
(“black area”) approx. 1,5 Mio. cft<br />
- Above the product <strong>in</strong> the barrier ISO-class 8 and better<br />
(class 100,000)<br />
Example 2:<br />
The barrier is operated with outgo<strong>in</strong>g air. The unit was<br />
<strong>in</strong>stalled <strong>in</strong> a clean-room of class 100,000 (ISO 8) directly<br />
bordered on the warehouse. Com<strong>in</strong>g from the warehouse<br />
(“black area”), the pallets or s<strong>in</strong>gle conta<strong>in</strong>ers are<br />
transported <strong>in</strong>to the barrier from the front side by a<br />
conveyor. The lift<strong>in</strong>g shutter of the barrier shields the<br />
clean-room towards the warehouse. Therefore, a material<br />
lock was unnecessary. In the barrier, conta<strong>in</strong>ers of different<br />
dimensions are lifted <strong>in</strong>to an ergonomic sampl<strong>in</strong>g position<br />
by a lift<strong>in</strong>g table.<br />
Air qualities:<br />
- In the warehouse (“black area”) approx. 1,5 Mio. cft<br />
- In the <strong>in</strong>stallation room ISO-class 8 (class 100,000)<br />
- In the barrier above the product ISO-class 6 (class 1,000)<br />
Beispiel 2:<br />
Example 2:
Probenahme- <strong>und</strong> Probezugkab<strong>in</strong>en<br />
Sampl<strong>in</strong>g Cab<strong>in</strong>s<br />
Beispiel 3:<br />
E<strong>in</strong> Doppelbarrier bei dem die Probenahme<br />
von zwei Seiten aus erfolgen<br />
kann, so dass sich der Mitarbeiter,<br />
auch ohne das Geb<strong>in</strong>de zu verschieben,<br />
nicht über das <strong>Produkt</strong> beugen<br />
muss. Mit Filtertechnik <strong>in</strong> der Rückwand<br />
ausgerüstet, wird der Barrier <strong>in</strong><br />
Umluft betrieben. Die Paletten werden<br />
stirnseitig auf e<strong>in</strong>e Waage aufgestellt.<br />
Luftqualitäten:<br />
- Im Aufstellungsraum ISO-Klasse 6<br />
(Klasse 1.000)<br />
- Über dem <strong>Produkt</strong> ISO-Klasse 5<br />
(Klasse100)<br />
Beispiel 3:<br />
Example 3:<br />
Example 3:<br />
A double barrier on which the sampl<strong>in</strong>g<br />
can be made from two sides, <strong>in</strong><br />
such a way that the operator, without<br />
mov<strong>in</strong>g the conta<strong>in</strong>er, does not have<br />
to bend over the product. Equipped<br />
with filter technology <strong>in</strong> the rear wall,<br />
the barrier is operated with circulat<strong>in</strong>g<br />
air. The pallets are put on the face side<br />
on a scale.<br />
Air qualities:<br />
- Installation room ISO-class 6<br />
(class1,000)<br />
- Over the product ISO-class 5<br />
(class100)<br />
14
Isolatorensysteme<br />
Isolator Systems<br />
Jahrelange Erfahrung <strong>in</strong> der Inertgas- <strong>und</strong> Glove-Box-<br />
Technik bilden die Gr<strong>und</strong>lage, auf der die Weiss GWE mit<br />
ihren Partnerfirmen die neue modulare Baureihe der Isolatoren<br />
entwickelt hat.<br />
Die beiden Systemreihen<br />
- Unterdruck-Isolatoren für toxische <strong>Produkt</strong>e (<strong>Personen</strong><strong>und</strong><br />
Raumschutz) mit speziellem berührungsfrei<br />
wechselbaren Filtersystemen<br />
- Lam<strong>in</strong>ar-Flow Isolatoren nach EC GMP Grade<br />
A (vorrangig <strong>Produkt</strong>schutz), die <strong>in</strong> Über- oder Unterdruck<br />
betrieben werden können.<br />
Die Modifizierung mit folgendem umfangreichen Zubehör<br />
ermöglicht e<strong>in</strong> erweitertes E<strong>in</strong>satzgebiet der Isolatoren:<br />
- Spezielle Schleusensysteme, mit oder ohne Lüftung/<br />
Spülung<br />
- Inertisierung <strong>und</strong> entsprechendes Monitor<strong>in</strong>g<br />
- Abwurfschleusen für kontam<strong>in</strong>iertes Material<br />
(z.B. Endlosschlauch)<br />
- Dock<strong>in</strong>g-Systeme (Alpha <strong>und</strong> Beta) mit visueller<br />
Kontrolle oder Verriegelung<br />
- spezielle Handschuhre<strong>in</strong>igungssysteme. E<strong>in</strong>faches<br />
Verschließen von nicht benutzten Handschuhparts<br />
ohne Conta<strong>in</strong>ment Unterbrechung<br />
- Integration e<strong>in</strong>er Waschmasch<strong>in</strong>e<br />
Die E<strong>in</strong>satzgebiete s<strong>in</strong>d u. a.<br />
- E<strong>in</strong>waage-Isolatoren<br />
- IPC-Isolatoren<br />
- Nassgranulierungs-Isolatoren<br />
- Isolatoren mit <strong>in</strong>tegrierter Tablettenpresse<br />
- Re<strong>in</strong>igungs-Isolatoren mit Ablauf<br />
usw.<br />
15<br />
Years of experience <strong>in</strong> the techniques of <strong>in</strong>ert gas and glove<br />
boxes formed the basis on which the new modular series<br />
has been developed by the Weiss GWE and their partner<br />
companies.<br />
The both systems of this series are:<br />
- Underpressure isolators designed for toxic products<br />
(Protection of person and room) with special contactless<br />
replaceable filter systems<br />
- Lam<strong>in</strong>ar flow isolators correspond<strong>in</strong>g to EC GMP Grade A<br />
(Priority: Protection of products), which can be operated<br />
with over- or <strong>und</strong>erpressure.<br />
An extended field of application of the isolators is possible<br />
by a modification with the follow<strong>in</strong>g wide ranged<br />
accessories:<br />
- Special lock systems with or without ventilation/ flush<strong>in</strong>g<br />
(e. g. cont<strong>in</strong>uous hose)<br />
- Inertisation and correspond<strong>in</strong>g monitor<strong>in</strong>g<br />
- Discharge locks for contam<strong>in</strong>ated materials<br />
- Dock<strong>in</strong>g systems (Alpha and Beta) with visual control or<br />
clos<strong>in</strong>g<br />
- Special glove clean<strong>in</strong>g systems<br />
Easy clos<strong>in</strong>g of not used gloves parts without an<br />
<strong>in</strong>terruption of conta<strong>in</strong>ment<br />
- Integration of a wash<strong>in</strong>g mach<strong>in</strong>e<br />
The fields of application are (among other th<strong>in</strong>gs):<br />
- Isolators with weigh<strong>in</strong>g units<br />
- IPC isolators<br />
- Wet granulation isolators<br />
- Isolators with <strong>in</strong>tegrate pellet<strong>in</strong>g press<br />
- Clean<strong>in</strong>g isolator with outflow<br />
etc.
Isolatoren Wiege- <strong>und</strong> Umfülle<strong>in</strong>heit<br />
Isolator Weigh<strong>in</strong>g and Refill<strong>in</strong>g Unit<br />
Müssen die Person, das <strong>Produkt</strong> <strong>sowie</strong> das Umfeld absolut<br />
sicher geschützt se<strong>in</strong>, wird <strong>in</strong> der zukunftsorientierten Forschung<br />
<strong>und</strong> <strong>Produkt</strong>ion immer häufiger die Forderung nach<br />
„geschlossenen Anlagen“ gestellt.<br />
Bekannte Glove Box Systeme s<strong>in</strong>d vorwiegend auf Inertgasatmosphäre<br />
ausgerichet. Beim WIBOsafe System standen<br />
die Forderungen nach gezielter Luftführung <strong>und</strong> Schadstofferfassung<br />
<strong>sowie</strong> hoher <strong>Produkt</strong>schutz durch Re<strong>in</strong>luftatmosphäre<br />
Pate. Sie eignen sich daher auch sehr gut für<br />
Arbeiten mit höherem Staubanfall.<br />
Die wichtigsten Kriterien:<br />
- hohe Sicherheit für Bedienpersonal <strong>und</strong> <strong>Produkt</strong><br />
- leichtes <strong>und</strong> ergonomisches Handl<strong>in</strong>g<br />
- sicheres, e<strong>in</strong>faches E<strong>in</strong>-/Ausschleusen mit aktiver<br />
Abre<strong>in</strong>igung<br />
- hohe Luftumwälzungen, gute Staub- <strong>und</strong> Schadstofferfassung,<br />
ger<strong>in</strong>ge Innenverschmutzung<br />
- Umluft-, Fortluft-, Mischluftbetrieb möglich<br />
- leichtes, bequemes Re<strong>in</strong>igen, Des<strong>in</strong>fizieren, Trocknen<br />
der Multifunktionspistole<br />
- kontam<strong>in</strong>ationsfreies Ausschleusen <strong>und</strong> Entsorgen der<br />
Verpackung bzw. Inl<strong>in</strong>er<br />
- GMP/FDA-gerechte Ausführung, leichte Qualifizierung,<br />
Validierung<br />
Nahezu alle Größenordnungen <strong>und</strong> Ausführungen s<strong>in</strong>d<br />
realisierbar.<br />
16<br />
If the person, the product as well as<br />
their environment must be protected<br />
absolutely safely, the demand for<br />
“closed units” is expressed <strong>in</strong>creas<strong>in</strong>gly.<br />
Known glove box systems are ma<strong>in</strong>ly<br />
designed for <strong>in</strong>ert gas atmosphere.<br />
The requirements of well directed airflow,<br />
capture of pollutants and high<br />
protection of the product by clean-air<br />
atmosphere have been the force beh<strong>in</strong>d<br />
the WIBOsafe system. They are<br />
well suitable for works with higher<br />
quantity of dust <strong>in</strong> atmosphere.<br />
The most important criteria are:<br />
- high rate of safety for operator and<br />
product<br />
- easy and ergonomic handl<strong>in</strong>g<br />
- safe and easy transfer with active<br />
clean<strong>in</strong>g<br />
- high air re-circulation, efficient<br />
capture of dust and pollutants, Iow<br />
pollution of the <strong>in</strong>side<br />
- Operation <strong>in</strong> circulat<strong>in</strong>g, total<br />
exhaust or mixed air possible<br />
- easy and comfortable clean<strong>in</strong>g,<br />
dis<strong>in</strong>fection, dry<strong>in</strong>g with multifunction<br />
pistol<br />
- contam<strong>in</strong>ation-free exit transfer<br />
and disposal of pack<strong>in</strong>g material<br />
resp. <strong>in</strong>l<strong>in</strong>er<br />
- GMP/FDA suitable design, easy<br />
qualification, validation<br />
Nearly all dimensions and designs are<br />
available.
Isolator<br />
<strong>Personen</strong>- <strong>und</strong> Raumschutz - Isolator zur Verwiegung<br />
<strong>und</strong> Umfüllung von Hormonen<br />
Technische Merkmale:<br />
- im rechten Bereich e<strong>in</strong>e E<strong>in</strong>fahrschleuse mit Deckelentnahme<br />
für das Geb<strong>in</strong>de <strong>und</strong> Andockmechanismus<br />
zum Isolator. Über diese Schleuse wird das <strong>Produkt</strong> <strong>in</strong><br />
Säcken <strong>in</strong> den Isolator e<strong>in</strong>geschleust.<br />
- Arbeitsbereich: elektropoliert mit Ablaufneigung im<br />
Tischbereich, auf der Arbeitsfläche ist e<strong>in</strong>e Kle<strong>in</strong>waage<br />
<strong>und</strong> e<strong>in</strong>e NIRS Sonde <strong>in</strong>tegriert. Der Isolator ist mit e<strong>in</strong>er<br />
CIP E<strong>in</strong>heit für das Re<strong>in</strong>igen ausgerüstet. Die gesamte Luft<br />
wird über HEPA Filter filtriert, das Luftvolumen zur Erfassung<br />
der Schadstoffe im Isolator beträgt ca. 200 m³/h.<br />
- Im l<strong>in</strong>ken Bereich wird e<strong>in</strong> Conta<strong>in</strong>er angedockt. In diesen<br />
Behälter wird das re<strong>in</strong>e Hormon e<strong>in</strong>gefüllt. Nach dem E<strong>in</strong>füllen<br />
werden die Deckel verschlossen. Der Conta<strong>in</strong>er<br />
kann dann für den weiteren Prozess entfernt werden. Die<br />
leeren Säcke <strong>und</strong> Werkzeuge werden über die E<strong>in</strong>fahrschleuse<br />
<strong>in</strong> das Geb<strong>in</strong>de ausgeführt <strong>und</strong> das Geb<strong>in</strong>de<br />
verschlossen.<br />
- Breite des Isolators beträgt 2500 mm, die Tiefe im Arbeitsbereich<br />
630 mm. Der Arbeitsbereich wird über sechs E<strong>in</strong>grifföffnungen<br />
erreicht.<br />
- Die Anlage wird über e<strong>in</strong>e S7 Steuerung gesteuert, geregelt<br />
<strong>und</strong> überwacht. Über e<strong>in</strong>en 6 Kanal Schreiber wird<br />
das Monitor<strong>in</strong>g der Anlage vorgenommen.<br />
17<br />
Isolator for Weigh<strong>in</strong>g and<br />
Refill<strong>in</strong>g of Hormones with<br />
Protection of Person and Room<br />
Technical features:<br />
- In the right area, a material lock is<br />
<strong>in</strong>stalled with lid removal for the<br />
conta<strong>in</strong>er as well as a dock<strong>in</strong>g<br />
mechanism towards the isolator.<br />
The product is filled <strong>in</strong> sacs and<br />
sluiced <strong>in</strong>to the isolator by the lock.<br />
- Work area: Electro-polished with an<br />
outflow decl<strong>in</strong>ation <strong>in</strong> the table<br />
area. On the work<strong>in</strong>g surface, a<br />
small scale and a NIRS probe are<br />
<strong>in</strong>tegrated. The isolator is equipped<br />
with a CIP unit for the clean<strong>in</strong>g. The<br />
total air is filtrated by HEPA filters.<br />
The volume of air for the captur<strong>in</strong>g<br />
of pollutants <strong>in</strong> the isolator is<br />
approx. 200 m3 /h.<br />
- In the left area, a conta<strong>in</strong>er is<br />
docked <strong>in</strong> which the pure<br />
hormone is filled <strong>in</strong>. After the fill<strong>in</strong>g<br />
the lids are closed. Then the<br />
conta<strong>in</strong>er can be removed for the<br />
further process. By the material<br />
lock the empty sacs and tools<br />
are sluiced <strong>in</strong> a package which then<br />
will be closed.<br />
- Width of the isolator: 2500 mm;<br />
depth <strong>in</strong> work<strong>in</strong>g area: 630 mm.<br />
The work<strong>in</strong>g area can be reached by<br />
6 open<strong>in</strong>gs.<br />
- The unit is controlled, regulated<br />
and monitored by a S7 control. The<br />
monitor<strong>in</strong>g of the unit is carried out<br />
by a 6 channel recorder.
Berührungsfreier Filterwechsel vom Arbeitsplatz aus<br />
Contactless Replacement of Filter via the Work<strong>in</strong>g Area<br />
Die Anordnung von Filter- <strong>und</strong> Luftre<strong>in</strong>igungssystemen<br />
direkt <strong>in</strong> der Rückwand, d.h. direkt bei der Erfassung der<br />
Schadstoffe, br<strong>in</strong>gt erhebliche Vorteile. Wesentlich weniger<br />
Flächen <strong>und</strong> Raumbereiche werden kontam<strong>in</strong>iert.<br />
Durch niedrige Luftmengen des WIBOjekt-Systems <strong>und</strong> die<br />
großen Anströmflächen ergeben sich kle<strong>in</strong>ere Flächen-,<br />
Filterbelastungen <strong>und</strong> Widerstände. Hohe Re<strong>in</strong>igungskapazität<br />
<strong>und</strong> niedrige Betriebs- <strong>sowie</strong> Investitionskosten s<strong>in</strong>d<br />
bei ger<strong>in</strong>gstem Platzbedarf die Folgen.<br />
Unterschiedliche Filtermaterialien <strong>und</strong><br />
Qualitäten können e<strong>in</strong>gesetzt werden.<br />
Die Wartung erfolgt direkt vom Arbeitsbereich<br />
aus, so dass andere Bereiche<br />
nicht belastet werden. Auf Wunsch können<br />
die Filteranlagen auch im separaten<br />
Gehäuse geliefert werden.<br />
Abre<strong>in</strong>igbare Filter mit Rotationsdüsen<br />
Cleanable Filters with Rotation Nozzles<br />
Durch die Rotationsdüsen werden die e<strong>in</strong>zelnen Filterfalten<br />
nache<strong>in</strong>ander schonend gewalkt <strong>und</strong> dabei vollflächig abgere<strong>in</strong>igt.<br />
E<strong>in</strong>e 1“-Druckluftleitung genügt.<br />
Das Spezial-Filtermaterial Polyester mit PTFE, antistatisch,<br />
hat bei 0,3 µ Partikelgröße e<strong>in</strong>en Abscheidegrad von 99,96 %,<br />
bei 1 µ 100 %. Es eignet sich auch hervorragend für z.B.<br />
klebrige <strong>und</strong> hygroskopische, schwer abre<strong>in</strong>igbare Problemstäube.<br />
Nach der<br />
Abre<strong>in</strong>igung ist ohne<br />
neue Kuchenbildung<br />
nahezu sofort die<br />
volle Wirksamkeit<br />
wieder vorhanden.<br />
18<br />
The arrangement of filter and air clean<strong>in</strong>g systems directly<br />
<strong>in</strong> the rear wall, i.e. directly where the pollutants are captured,<br />
leads to considerable advantages because less surface and<br />
room areas are contam<strong>in</strong>ated.<br />
The Iow air volume required by the WIBOjekt system and the<br />
large reception surfaces lead to Iow load<strong>in</strong>g of surfaces and<br />
filters as well as to Iow resistances. Consequently, there is a<br />
high clean<strong>in</strong>g capacity and Iow operat<strong>in</strong>g and <strong>in</strong>vestment<br />
costs with only m<strong>in</strong>imal need of space.<br />
Various filter materials and qualities<br />
can be used. Ma<strong>in</strong>tenance is carried out<br />
directly from the work<strong>in</strong>g area which<br />
means that other areas are not affected.<br />
On request the filter units can be<br />
delivered <strong>in</strong> a separate case.<br />
Rotation nozzles carefully move the filter folds <strong>in</strong>dividually,<br />
thus clean<strong>in</strong>g them completely. A 1”-compressed air l<strong>in</strong>e is<br />
sufficient and compressed air buffers are not needed.<br />
The special filter material polyester with PTFE, anti-static,<br />
has an efficiency of 99,96 % for 0,3 µ particle size and of 100 %<br />
for 1,0 µ. It is also well usable for e.g. sticky and hygroscopic<br />
problematic dusts which are difficult to clean. Almost<br />
immediately<br />
after clean<strong>in</strong>g<br />
full efficiency<br />
is restored<br />
without a rest<br />
rema<strong>in</strong><strong>in</strong>g.
Lam<strong>in</strong>ar-Flow E<strong>in</strong>heit<br />
Lam<strong>in</strong>ar Flow Unit<br />
Vertikalstrom-Module<br />
für den <strong>Produkt</strong>schutz<br />
Der E<strong>in</strong>satz dieser Lam<strong>in</strong>ar-Flow-Module ist vielseitig <strong>und</strong><br />
erfolgt <strong>in</strong> der <strong>in</strong>dustriellen Fertigung zum <strong>Produkt</strong>schutz<br />
über<br />
- Abfüllstationen / Verpackungsanlagen<br />
- <strong>in</strong> der Pharmazeutischen Industrie, Lebensmittel- <strong>und</strong><br />
Kosmetik-Industrie<br />
- beim Farbstofflasern oder bei Montageprozessen,<br />
die unter Re<strong>in</strong>raumbed<strong>in</strong>gungen zu betreiben s<strong>in</strong>d <strong>und</strong><br />
bei denen das <strong>Produkt</strong> nicht emittiert.<br />
Die Module lassen sich zu Anlagenvarianten unterschiedlicher<br />
Größen <strong>und</strong> Anordnungen konfigurieren. Z. B. auch<br />
über Eck- oder T-förmig.<br />
Zur serienmäßigen Ausstattung gehören:<br />
- stufenlos regelbare Gebläse<br />
- Beleuchtung<br />
- Luftgeschw<strong>in</strong>digkeitsmesser mit Analog- oder Digitalanzeige<br />
- Vorfilter EU 3, Hochleistungs-Schwebstofffilter<br />
mit e<strong>in</strong>em Abscheidegrad von 99,99% Klasse 5<br />
Es ist e<strong>in</strong>e e<strong>in</strong>fache <strong>und</strong> platzsparende Montage der Module<br />
durch Deckenabhängung, auf Stützen stehend, oder auch<br />
verfahrbar möglich.<br />
19<br />
Vertical Flow Modules<br />
for the Protection of Products<br />
The application of these Lam<strong>in</strong>ar-<br />
Flow-Modules is various and takes<br />
place <strong>in</strong> the <strong>in</strong>dustrial manufactur<strong>in</strong>g<br />
for the protection of products <strong>in</strong> the<br />
follow<strong>in</strong>g areas:<br />
- Fill<strong>in</strong>g stations / pack<strong>in</strong>g units<br />
- Pharmaceutical-, food- and<br />
cosmetic <strong>in</strong>dustry<br />
- Dye las<strong>in</strong>g or assembl<strong>in</strong>g<br />
processes, demand<strong>in</strong>g clean-room<br />
conditions and <strong>in</strong> which the<br />
product is not emitt<strong>in</strong>g.<br />
The modules can be configured to<br />
unit variants of different dimensions<br />
and arrangements, e. g. across<br />
corners or <strong>in</strong> t-shape.<br />
The standard equipment <strong>in</strong>cludes:<br />
- Inf<strong>in</strong>itely variable and adjustable<br />
blower<br />
- Illum<strong>in</strong>ation<br />
- Air speed <strong>in</strong>dicator with analogueor<br />
digital display<br />
- Pre-filter EU 3, high-tech air filter<br />
with separation rate of 99,99 %<br />
class 5<br />
Easy and place sav<strong>in</strong>g assembly of the<br />
modules by suspension of the ceil<strong>in</strong>g,<br />
stand<strong>in</strong>g on supports or be<strong>in</strong>g<br />
transportable is possible.
Wir orientieren uns an Ihren Anforderungen<br />
We orient ourselves to your demands<br />
Weiss GWE GmbH<br />
Wiechmannsallee 3<br />
27798 Hude<br />
Germany<br />
Tel.: + 49 (0) 4484 189-0<br />
Fax: + 49 (0) 4484 189-189<br />
contact@gwe.de<br />
www.gwe.de<br />
Pharmazeutische Industrie<br />
Gentechnologie<br />
Biotechnologie<br />
Kosmetik-Industrie<br />
Lebensmittel-Industrie<br />
Chemische Industrie<br />
Elektronik-Industrie<br />
Mediz<strong>in</strong>technik<br />
Mikromechanik<br />
Nanotechnologie<br />
Optische Industrie<br />
Systemtechnik<br />
Industrieller <strong>Produkt</strong>ionsbetrieb<br />
Sicherheitstechnik<br />
Lack- <strong>und</strong> Oberflächentechnik<br />
Labore<br />
Institute<br />
Universitäten<br />
Lehre<br />
Krankenhäuser<br />
Pathologien<br />
Montage<br />
Inbetriebnahme<br />
Validierungs-Qualifizierungen<br />
DQ, IQ, OQ<br />
Dokumentationen<br />
SOP<br />
Wartungen<br />
Pharmaceutical Industry<br />
Gene Technology<br />
Biotechnology<br />
Cosmetics-Industry<br />
Food-Industry<br />
Chemical Industry<br />
Elektronics-Industry<br />
Medical Eng<strong>in</strong>eer<strong>in</strong>g<br />
Micromechanics<br />
Nanotechnology<br />
Optical Industry<br />
System Eng<strong>in</strong>eer<strong>in</strong>g<br />
Industrial Manufactur<strong>in</strong>g<br />
Safety Eng<strong>in</strong>eer<strong>in</strong>g<br />
Lacquer and Surface Technology<br />
Laboratories<br />
Institutes<br />
Universities<br />
Education<br />
Hospitals<br />
Pathologies<br />
Assembly<br />
Commission<strong>in</strong>g<br />
Qualifications for Validation<br />
DQ, IQ, OQ<br />
Documentation<br />
SOP<br />
Ma<strong>in</strong>tenance<br />
WIBOjekt, WIBObarrier, WIBOsafe = Registered trademarks ® ; 5/03, 3.0, borrek / Technische Änderungen vorbehalten; subject to technical alterations.