FIBER META LTAPER HIPP R O S T H E S I SVersatile Total HipSolutions UsingP r oven Designs andEnhanced Fixation
V E R S Y S F I B E R M E T A L T A P E RS t dL MS t a n d a rd (Std) and Larg eMetaphyseal (LM)The LM versions incre a s ethe medial curve by 4mmto 5mm, depending on thestem size, allowing surgeonsto precisely matchimplant geometries topatient needs.** Re qu i res special LM rasp forfemur pre p a ra t i o n .PROVEN DESIGN WITH ENHANCED FIXATION.The Ve r S ys Fiber Metal Taper Hip Pro sthesis incorp o ra tes a fiber meta li n grow th surface, a corundum ongrow th surface, and a polished,ta p e red distal tip within a single pro sthesis. Many of these cementlessstem concepts are based on ye a rs of successful clinical ex p e ri e n c e . 1, 2 , 3 , 4P rox i m a l ly, the ste m’s titanium fiber metal surface pro m otes bonei n grow th. In addition, the corundum surface finish of the mid-stem re g i o nf u rther pro m otes a secure bone-implant inte rface and allows for boneo n grow th. Dista l ly, the stem is polished to discoura ge distal fixation andta p e red to increase flexibility and avoid contact with cortical bone inn a rrowing distal fe m u rs.An essential foundation for Ve r S ys was the A NA DAT ® A n a to m i c a lD a tabase, comp rising detailed anatomic measurements ofc a d aver fe m o ra that guided implant sizing and design. 5Combined with ex te n s i ve ly re s e a rched implant mate rialsand clinically proven fe a t u res, A NA DATenabled the creation of a syste mdesigned for optimum ve rs a t i l i t y,f u n c t i o n a l i t y, and long-te rm results.Vast improvements havebeen made in total hipa rt h roplasty since theearliest implants weredeveloped more than fourdecades ago. Yet, there area number of key issues thato rthopaedic surgeons facet o d a y. The most signific a n tof these are :I s s u e s= C o s t= Patient Fit= F i x a t i o n= We a r= K i n e m a t i c s= I n s t ru m e n t a t i o nCalcicoat ® C e r a m i cC o a t i n g(HA/TCP)**is available for theVerSys Fiber MetalTaper Hip Pro s t h e s i s .**Not curre n t ly available fo rc o m m e rcial dist ribution inthe U. S .True patient specificityAvailable in nine standard sizesand five LM sizes, the Ve r S y sFiber Metal Taper Hip Pro s t h e s i sf e a t u res a proximal fiber metali n g rowth surface, a coru n d u mo n g rowth surface, and a narrowdistal taper which allowss u rgeons to match individualpatient re q u i rements andachieve optimum pro x i m a limplant fix a t i o n .System Rasp is used to implantthe VerSys Fiber Metal Ta p e rHip Pro s t h e s i s . † The systemrasp is designed to be usedwith both cemented andcementless implants, pro v i d -ing greater intraoperativeflexibility and cost-effic i e n c ythan traditionalinstru-†M u st not be used in conjunction withthe Ve r S ys Enhanced Taper Ra s p .
C i rc u m f e rential poro u ss u rf a c ep e p rovides completep roximal coverage.P ro g ressive neck lengths,v e r i fied with ANADAT,facilitate leg length ando ffset re s t o r a t i o n . 6Stem diameters a re availablein 1mm incrementswith both standard andLM proximal bodies tohelp improve fit.BAP o rous surface to raspp re s s - fit f rom 0mm (A) to0.5mm (B) yields a secureinitial pre s s - fit .Femoral heads andacetabular componentsZimmer offers a full complementof femoral heads andacetabular components. † †† †12 / 14 Taper Zirconia heads are notavailable for commercial dist ributionin the U. S .C o rundumized surfacefinish is designed to pro m o t ea secure bone implanti n t e rface and allow forbone ongro w t h . 7Ta p e red and polished distals t e m is designed to discouragedistal fixation and impro v ep roximal loading. 3Trapezoidal cross-section geometryi m p roves proximal fill, promotes loadtransfer from stem to bone, and pro v i d e sinitial rotational stability.Universal Stem Driverhelps control implantrotation and alignmentduring stem insert i o n .I n s t ru m e n t a t i o nis designed toi m p rove intrahospital effic i e n c ywhile accommodating cemented,p o rous, taper, and fracturep ro c e d u re s .
V E R S Y S F I B E R M E T A L T A P E R P R O D U C T D A T AL MDBAC135° Neck AngleVe r S y s Fi b e r Me t a l Ta p er*CDFiber Metal Fiber Metal A O ffset (mm) When Head/N e c k Neck Length (mm) When Head/N e c kTaper Taper LM Stem Size B P rosthesis is: P rosthesis is:Cat. No. Cat. No. and Dia. Stem Length - 3 . 5 0 + 3 . 5 +7 + 10 . 5 -3.5 0 + 3 . 5 + 7 + 10 . 57862-09-00 – 9 110 30 33 35 38 40 24 28 31 35 387862-10-00 – 10 115 30 33 35 38 40 24 28 31 35 387862-11-00 – 11 120 33 36 38 41 43 28 32 35 39 427862-12-00 7862-12-30 12 125 36 39 41 44 46 30 34 37 41 447862-13-00 7862-13-30 13 130 36 39 41 44 46 30 34 37 41 447862-14-00 7862-14-30 14 135 39 42 44 47 49 35 38 42 45 497862-15-00 7862-15-30 15 140 39 42 44 47 49 35 38 42 45 497862-16-00 7862-16-30 16 145 42 45 47 50 52 39 42 46 49 537862-17-00 – 17 150 42 45 47 50 52 39 42 46 49 537862-18-00 – 18 155 45 48 50 53 55 43 46 50 53 57S t d = S t a n d a rd Body OptionL M = L a rge Metaphysis Body Option* Fiber Metal Taper Stems re q u i re the use of 7892-10/18-00, 30 rasps.Ve r S y s Femoral Head OptionsCat. No.D e s c r i p t i o n8018 - 22 - 02 Femoral Head 0 x 22mm Dia8018 - 26 - 02 Femoral Head 0 x 26mm Dia8018 - 26 - 03 Femoral Head +3.5 x 26mm Dia8018 - 26 - 04 Femoral Head +7 x 26mm Dia8018 - 26 - 05 Femoral Head +10.5 x 26mm Dia8018 - 28 - 01 Femoral Head -3.5 x 28mm Dia8018 - 28 - 02 Femoral Head 0 x 28mm Dia8018 - 28 - 03 Femoral Head +3.5 x 28mm Dia8018 - 28 - 04 Femoral Head +7x 28mm Dia8018 - 28 - 05 Femoral Head +10.5 x 28mm Dia8018 - 32 - 01 Femoral Head -3.5 x 32mm Dia8018 - 32 - 02 Femoral Head 0 x 32mm DiaCat. No.D e s c r i p t i o n8018 - 32 - 03 Femoral Head +3.5 x 32mm Dia8018 - 32 - 04 Femoral Head +7 x 32mm Dia8018 - 32 - 05 Femoral Head +10.5 x 32mm Dia8118 - 22 - 02 Z i rconia Femoral Head +0 x 22mm Dia**8118 - 26 - 02 Z i rconia Femoral Head +0 x 26mm Dia**8118 - 26 - 03 Z i rconia Femoral Head +3.5 x 26mm Dia**8118 - 28 - 01 Z i rconia Femoral Head -3.5 x 28mm Dia**8118 - 28 - 02 Z i rconia Femoral Head +0 x 28mm Dia**8118 - 28 - 03 Z i rconia Femoral Head +3.5 x 28mm Dia**8118 - 32 - 01 Z i rconia Femoral Head -3.5 x 32mm Dia**8118 - 32 - 02 Z i rconia Femoral Head +0 x 32mm Dia**8118 - 32 - 03 Z i rconia Femoral Head +3.5 x 32mm Dia**** 12/14 Taper Zirconia heads are not available for commercial distribution in the U.S.1. Mulliken BD, Bourne RB, Rorabeck CH, et al. A tapered titanium femoral steminserted without cement in a total hip arthroplasty. J Bone Joint Surg. 1996;78-A(8):1214-1225.2. Mallory TH. Total hip replacement in the 1990s: the procedure, the patient, the surgeon.Contemporary Orthopaedics. 1992;15:427-430.3. Mallory TH, Head WC. A total hip replacement system: clinical experience and recommendations.Contemporary Orthopaedics. 1988;17(4):21-28.4. Hozack W, Gardiner R, Hern S, et al. Taperloc femoral component. J Arthroplasty.1994;9(5):489-493.5. Data on file at Zimmer.6. Steinbert B, Harris WH. The ‘offset’ problem in total hip arthroplasty. ContemporaryOrthopaedics. 1992;24:5.7. Feighan JE, Goldberg VM, Davy D, et al. The influence of surface-blasting on theincorporation of titanium-alloy implants in a rabbit intramedullary model. J BoneJoint Surg. 1995;77-A(9):1380-1395.Various components of the VerSys Hip System are covered by one or more of thefollowing: U.S. Patents 4,281,420; 4,336,618; 4,491,987; 4,795,472; 4,963,155; 5,013,324;5,018,285; 5,089,003; 5,156,624; 5,171,324; 5,192,323; 5,326,362; 5,480,453; 5,496,375;5,569,255. Other U.S. and Foreign Patents Pending.