<strong>FiberFlex</strong> <strong>Specifications</strong>LFXG Analog/Digital Output SES-0046 Revision: 0 03/28/00 1/24241 Allendorf Drive Cincinnati, Ohio 45209 U.S.A. (513) 272. 0131 Fax (513) 272. 0133 www.ohmart.comSystem Accuracy ±1% of span typical Accuracy depends on specific application parametersActive Lengths Flexible detector 12" to 276" (305mm to 7010mm) in 12" (305mm) incrementsTypical Sources Cesium-137 0.66MeV gamma radiation emitter, 30.2 year half lifeCobalt-601.2 and 1.3 MeV gamma radiation emitter, 5.3 year half lifePower Requirements AC 90 to 270VAC at 50 to 60Hz, at 15 VA maximum power consumption(25 VA max with heater)+100 to 230 VAC - 10% (for A compliance)DC20 to 60 VDC (less than 100 mV, 1 to 1000 Hz ripple) at 15VA24VDC (for A compliance)Signal Cable Maximum length 3280 ft (1000 m)HART ® signal18-22 AWG (0.82-0.33 mm 2 ) two conductor shieldedFlexible Detector Material Organic scintillator fibers encased in galvanized steel flexible conduitcovered by Santoprene ® thermoplastic rubber 1)Bend radius1 foot (305 mm) minimumDiameterMounting1-3/4” (44 mm)Angle - bracket (standard)2” conduit mount ( detector inside conduit) optionalGEN2000 Electronics 4-Wire hookup with DC 18-22 AWG (0.82-0.33 mm 2 ) four conductor shieldedHousing Certified to CSA & UL Standards Designed to meet National Electric Code (U.S. & Canada)115 VAC and 24 VDC Class I, Groups B, C & D, Div. I & IIClass I Group A (pending)Class II, Groups E, F & G, Div. I & II220 VAC All classes, divisions, and groups pendingCENELEC CertificationEExd IIC T5 (pending)Enclosure RatingType NEMA 4XIP-66Ambient Temperature-4°F to 140°F (-20°C to 60°C), Low temperature option is availableHumidity0-95%, noncondensingVibration Tested to IEC68-2-6, IEC68-2-27, IEC 68-2-36MaterialCast Aluminum ASTM A357PaintEpoxy powder coatWeight Housing and flexible detector 12lb. + 1.lb. ´ active length in feet(5.44kg + 1.49kg ´ active length in meter)Current Loop Output Rating 4 to 20mA, isolated, into 250 to 1000ohmPowerJumper selectable source (active) or sink (passive) modeRelay Output Software user settable Diagnostic alarm or process high/low alarmfunctionRating6A at 240VAC (S P DT Form C)/8A at 24VDC; 1 ⁄4 HP at 120VACHART ® Communication HART ® Protocol on BEL202 FSK standardcurrent loop outputPC interfaceHART modem and Ohmart View communications software packageOptional hand-heldHART Communicator model 275 hand-held terminal withinterfaceOhmart device descriptions loadedAuxiliary Input Capability Type Frequency input (0 to 100 kHz)Possible functionOptional NORM compensation, vapor phase compensation,multiple gauge linking and othersElectronics On-board memory FLASH and two EEPROMsReal-time clockMaintains time, date and source decay compensationYear 2000 compatibleDiagnostics L E D indication +5V, Memory Corruption, H A RT ® , +24V, C P U Active, Auxiliary,High Voltage, Relay & Field Strength1) Santoprene ® thermoplastic rubber is designed to offer fluid and oil resistanceequivalent to that of neoprene. It is resistant to a wide variety of oils, solvents,and chemicals. Highly polar fluids, such as alcohols, ketones, glycols, esters, andaqueous solutions of acids, salts, and bases have little effect. Santoprene ® hasexcellent to good U.V. weather resistance. Temperature properties are -60º C to +135º C.SES-0046 Revision: 0 p. 1 of 2 <strong>Specifications</strong> are provided for informational purposes only, and are subject to change without noticeUS & Foreign Patent Pending


G<strong>FiberFlex</strong> Order CodeLFXG <strong>FiberFlex</strong> Scintillation Detector and GEN2000 ElectronicsDevice OutputH 4 to 20 mAdc output utilizing HART ® ProtocolD Foundation Fieldbus Digital OutputDetector Active Length12 12”/305mm24 24”/610mm36 36”/915mm48 48”/1219mm60 60”/1524mm72 72”/1829mm84 84"/2133mm96 96"/2438mm108 108"/2743mm120 120"/3048mm132 132"/3353mm144 144"/3657mm156 156"/3962mm168 168"/4267mm180 180"/4572mm192 192"/4877mm204 204"/5181mm216 216"/5484mm228 228"/5791mm240 240"/6096mm252 252"/6400mm264 264"/6705mm276 276"/7010mmVoltageV6 90-270 VAC 50/60 Hz / 20 - 60 VDCHazardous Area ApprovalsH0 No CertificationH1 CSA CertificationH2 CENELEC CertificationElectronics Housing MaterialM4 Aluminum Housing, epoxy powder coatedStandard OptionsS00 No optionsS23S43temperature detector purgeS57S58S73S86SZZAir Purge on electronic housing (non-cenelec/non-CSA)2” electrical conduit mounting adaption for detector/HighInternal heater for low ambient temperature (115 VAC)Internal heater for low ambient temperature (230 VAC)Sums input for multi detector applications (last detector)NORM Software compensation (requires pricing andspecification of an additional frequency output level detectorSpecial OptionLabelsL0 Standard label 3”x 2” ( 76 x 51 mm) with productspecifications custom PO, month-year, tag number.Included on the housing and equipment. Even if L1,L2, L3 is selectedL1L2L3L47.375"(187mm)Engraved plastic label 3.5” x .75” ( 90 x 19 mm),maximum 15 characters for tag#Engraved 304 SST Label 3.5” x .75”( 90 x 19 mm)maximum 15 characters for tag#Engraved 316 SST Label 3.5” x .75” ( 90 x 19 mm)maximum 15 characters for tag#Special label, with customer material, size and lettersPackingP0 Ground Package, Truck or Air (cardboard box)P1 Air Freight packing (Closed wood box) per detectorP2 Ocean packing (sealed wood box) per detectorsensorelectronics5.5"(140mm)8.343"(212mm)5.91"(150mm)2.687"(68mm)0.75"(19mm) NPT (2 PLCS)Flexible scintillatordetector minimumbend radius12" (305mm)5"(127mm)6.531"(166mm)12.343"(313mm)Wiring Diagram1 2 3 4 5 6 7 8 9 10 11 12 13 141 L12 L23 relay NO4 relay C5 relay NC67891011 Freq In +12 Freq In -13 mA +14 mA-mounting for0.313" (8mm)bolt (2) placesClearance height6" minimum10" preferredsensing area(length per application)LFXG V6 M4SES-0046 R0p. 2 of 2 <strong>Specifications</strong> are provided for informational purposes only, and are subject to change without notice

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!