LPC Approval to LPS1181 and/or LPS1208<br />

Full titles:<br />

LPS 1181: 2003: PART 1 -Series of Fire Growth<br />

Tests for LPCB Approval and Listing of Construction<br />

Product Systems - Part One: Requirements and<br />

Tests for Built-up Cladding and Sandwich Panel<br />

Systems for Use as the External Envelope of<br />

Buildings<br />

LPS 1181: 2003: PART 2 - Series of Fire Growth<br />

Tests for LPCB Approval and Listing of Construction<br />

Product Systems - Part Two: Requirements and<br />

Tests for Wall and Ceiling Lining Systems for Use<br />

as Internal Constructions in Buildings<br />

LPC Specifier’s Guide<br />

The LPC publish the “Red Book” for Fire and<br />

Security Products and Services which is a useful<br />

document for those working on design, specifi cation<br />

and purchase of contruction, fi re and security<br />

products and services.<br />

This publication includes products approved to LPS<br />

1181 Parts 1 & 2, and LPS 1208.<br />

It is available as a hard copy, CD, or can be<br />

referenced online at http://www.redbooklive.com/<br />

WebRedBook/RedBookHome.aspx<br />

LPS1208 - LPCB Fire resistance requirements<br />

for elements of construction used to provide<br />

compartmentation<br />

Like FM Global, the Loss Prevention Council in the<br />

UK also have their own third party independent<br />

approval process which also involves pre-fi re<br />

testing inspection and on going factory audits to<br />

verify ongoing performance.<br />

The fi re testing requirements and acceptance<br />

criteria are different to FM Global. The fi re testing<br />

does not utilise ISO9705 fi re test method, but uses<br />

a different LPC room corner fi re test method.<br />

LPC Approval to LPS1181 applies to materials<br />

used for wall and ceiling linings. LPC Approval to<br />

LPS1208 applies to materials used as fi re rated wall<br />

and ceiling assemblies<br />

The Alliance<br />

Shared Goal #5<br />

To promote competency based<br />

training, accreditation and licensing.<br />

TBG-03.2<br />

23.<br />

www.pfpa.com.au