Catalogue HY11-3500/UK<br />

Technical Data<br />

Pilot Operated <strong>Proportional</strong> <strong>DC</strong> <strong>Valves</strong><br />

Series 4DP02V, 4DP03,4DP06 (Denison)<br />

3<br />

General<br />

Design<br />

Actuation<br />

Size<br />

Mounting interface<br />

Mounting position<br />

Pilot operated <strong>DC</strong> Valve<br />

<strong>Proportional</strong> solenoid<br />

4DP02V<br />

NG10<br />

(CETOP 05)<br />

Ambient temperature [°C] -20...+50<br />

4DP03<br />

NG16<br />

(CETOP 07)<br />

DIN 24340 /ISO 4401 /CETOP RP121 /NFPA<br />

unrestricted, preferably horizontal<br />

4DP06<br />

NG25<br />

(CETOP 08)<br />

Weight [kg] 7.6 (1 sol.) 8.1 (2 sol.) 10.5 (1 sol.) 10.9 (2 sol.) 18.7 (1 sol.) 19.1 (2 sol.)<br />

Hydraulic<br />

Max.operating pressure<br />

Fluid<br />

[bar]<br />

[bar]<br />

Fluid temperature [°C] -20...+80<br />

Viscosity<br />

permitted [cSt] / [mm 2 /s]<br />

recommended [cSt] / [mm 2 /s]<br />

Pilot drain internal:P,A,B,X350; T, Y105 (4DP02V: T, Y15)<br />

Pilot drain external:P,A,B,T,X350; Y105 (4DP02V: Y15)<br />

Hydraulic oil as per DIN 51524...535, other on request<br />

10...650<br />

30<br />

Filtration ISO 4406 (1999) 18/16/13 (acc.NAS 1638: 7)<br />

Flow nominal at ∆ P=5 bar<br />

per control edge * [l/min] 90/120 200 400<br />

Leakage at 100 bar [ml/min] 100 200 600<br />

Pilot supply pressure [bar] 20-350 (optimal dynamics at 50)<br />

Pilot flow at 100bar [l/min]