30.08.2015 Views

B

B Series V-Pak - Hydraulics & Pneumatics Services

B Series V-Pak - Hydraulics & Pneumatics Services

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Catalog HY13-1552-001/NA,EU<br />

Hydraulics<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Series V-Pak<br />

Low Profile Power Units<br />

Catalog HY13-2600-520-001/US<br />

B<br />

Hydraulics<br />

B43<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Hydraulics<br />

B44<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Introduction<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

PRESSURE PORT<br />

RETURN PORT<br />

FILLER/BREATHER<br />

SINGLE REMOVABLE<br />

TOPPLATE<br />

PUMP COMPENSATOR<br />

CONTROL<br />

OIL LEVEL GUAGE<br />

WITH THERMOMETER<br />

406mm (16")<br />

CLEANOUT COVER<br />

SAE-12 RESERVOIR<br />

DRAIN<br />

PUMP CASE PREFILL PORT<br />

GLYCERINE FILLED<br />

PRESSURE GUAGE WITH<br />

SHUT-OFF VALVE<br />

SAFETY RELIEF VALVE<br />

B<br />

Standard Features<br />

• Vertical Design<br />

• Submerged Pump<br />

• Precision Pump Mounting Adapters<br />

• Suction Strainer<br />

• Glycerine Filled Pressure Gage with Shut Off<br />

• Oil Level Gage with Thermometer<br />

• Remote Compensator and Safety Relief<br />

• Breather and Fill Cap<br />

• 1800 RPM Motor<br />

• Drain Plug<br />

• Clean Out Cover<br />

• Single Removable Topplate<br />

• Extra SAE-20 Return Port<br />

• All Hydraulic Connections SAE Straight Thread<br />

Benefits<br />

• Saves Floor Space<br />

• Positive Pump Inlet<br />

• Longer Pump Life<br />

• Protects Pump from Contamination<br />

• Improved Diagnostics<br />

• Helps to Maintain Trouble-Free Performance<br />

• Protects Against System Shock<br />

• Easy to Fill Tank, Control Ingression of Airborne<br />

Contaminants<br />

• More Flow at Less Cost<br />

• Allows Drainage of Fluid<br />

• Easy Access to Inside of Reservoir<br />

• Easy Servicability of Internal Components<br />

• Allows Flexibility for Customer Return Plumbling<br />

• No Leaks<br />

Quick Reference Data Chart<br />

Low Profile Tank Size Pump Flow Electrical Motors Maximum<br />

V-Pak Liters (Gallon) LPM (GPM) @ 1800 RPM KW (HP) BAR (PSI)<br />

V6 227.1 (60) 42.0 (11.0) to 5.6-29.8 207<br />

V8 302.8 (80) 136.7 (36.1) (7 1/2 - 40) (3000)<br />

Hydraulics<br />

B45<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Introduction<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Performance Data<br />

Standard Features<br />

• Vertical Design<br />

• Submerged Pump<br />

• Precision Pump Mounting Adapters<br />

• Suction Strainer<br />

• Glycerine Filled Pressure Gage with Shut Off<br />

• Oil Level Gage with Thermometer<br />

• Relief Valve<br />

• External Pump Compensator Control<br />

• Breather and Fill Cap<br />

• 1800 RPM TEFC Motor<br />

• Cleanout Cover<br />

• Pressure and Return Port Block with Safety Relief<br />

• Remote Pump Compensator Control Valve<br />

Options<br />

• D05 (D02), D05H (D02H), D08 (D06) Single<br />

Station Manifold with Safety Relief<br />

• D05 (D02), D05H (D02H), D08 (D06) Multi-Station<br />

Manifold with Safety Relief<br />

• Pressure & Return Filters (10 Micron)<br />

• Immersion Heater<br />

• Variety of Manapak Sandwich Valves<br />

• Heat Exchangers (Air/Oil, Water/Oil)<br />

• Liquid Level Switch-Fixed<br />

• Temperature Switch-Adjustable<br />

• Combination Temp/Float Switch-Fixed<br />

• Pressure Switch-Adjustable<br />

• Single Pressure Remote Compensator<br />

• Single Pressure Remote Compensator with Low<br />

Pressure Standby<br />

• Bi-Pressure Remote Compensator<br />

• Bi-Pressure Remote Compensator with Low<br />

Pressure Standby<br />

• Electro Hydraulic Pressure Control-Consult Factory<br />

• Load Sensing (Flow Control)-Consult Factory<br />

• Horsepower Limiting-Consult Factory<br />

Specifications<br />

Parker “V-Pak” Hydraulic Power Units are vertical<br />

design, 227 or 303 liter (60 or 80 gallon) reservoirs<br />

utilizing Parker Variable Volume Piston Pumps.<br />

Warranty<br />

The hydraulic components on these Parker Power<br />

Units are warranteed for one year. This warranty may<br />

be extended to three years by using and properly<br />

maintaining Parker filters.<br />

Schematic Symbol<br />

(Basic Unit)<br />

SAE<br />

-12<br />

X<br />

“O”<br />

OPTION<br />

MANIFOLD<br />

M<br />

SUPPLY<br />

PORT<br />

SAE-16<br />

P<br />

RETURN<br />

PORT<br />

SAE-20<br />

“OMIT”<br />

OPTION<br />

COMP<br />

CONTROL<br />

SAE-20<br />

SPARE<br />

RETURN<br />

V-PAK BASIC UNIT<br />

—————————<br />

NO OPTIONS OR ACCESSORIES<br />

“OMIT” OPTION PUMP COMPENSATOR<br />

“O” OPTION MANIFOLD<br />

Installation Data:<br />

See page B62 of this catalog or Parker Installation/<br />

Maintenance Manual for specific recommendations<br />

pertaining to start-up, system cleanliness, fluids,<br />

temperatures and other important factors relative to<br />

proper installation and use of these power units.<br />

T<br />

Pump Tank Size Pump Flow Electrical Motors Maximum<br />

Model Liters (Gallon) LPM (GPM) @ 1800 RPM KW (HP) BAR (PSI)<br />

V-Paks<br />

227.1 (60) 42.0-136.1 5.6-29.8 207<br />

302.8 (80) (11.0-36.1) (7 1 /2 - 40) (3000)<br />

Hydraulics<br />

B46<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


SAFETY RELIEF<br />

DO NOT ADJUST<br />

Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Dimensions – Basic<br />

Shown with “Omit” Option Manifold<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Motor<br />

Code<br />

Motor Description Dimension<br />

H P-RPM-Frame-Type " A"<br />

"B"<br />

FILTER<br />

BREATHER<br />

(STANDARD)<br />

273.1<br />

(10.75)<br />

"B"<br />

231.7<br />

(9.12)<br />

M<br />

N<br />

P<br />

S<br />

7 1/2-1800-213TC-TEFC<br />

10-1800-215TC-TEFC<br />

15-1800-254TC-TEFC<br />

20-1800-256TC-TEFC<br />

451<br />

(16.6)<br />

451<br />

(17.2)<br />

451<br />

(20.0)<br />

597<br />

(23.5)<br />

N/A<br />

N/A<br />

48<br />

(1.88)<br />

48<br />

(1.88)<br />

B<br />

SAE-20<br />

SPARE RETURN<br />

PORT<br />

T<br />

PUMP PRIME<br />

PUMP COMPENSATOR<br />

CONTROL<br />

819.2<br />

(32.25)<br />

Q<br />

R<br />

V<br />

25-1800-284TC-TEFC<br />

30-1800-286TC-TEFC<br />

40-1800-324TC-TEFC<br />

579<br />

(22.8)<br />

620<br />

(24.4)<br />

627<br />

(24.7)<br />

51<br />

(2.0)<br />

51<br />

(2.0)<br />

144<br />

(5.69)<br />

P<br />

72.9<br />

(2.87)<br />

914.4<br />

(36.0)<br />

838.2<br />

(33.0)<br />

736.6<br />

(29.0)<br />

SAE-20 SPARE RETURN<br />

PORT (AVAILABLE WITHOUT<br />

RETURN FILTER ONLY)<br />

SUPPLY PORT<br />

SAE-16 ORB<br />

RETURN PORT<br />

SAE-20 ORB<br />

"OMIT" OPTION<br />

MANIFOLD<br />

Reservoir<br />

Dimension<br />

S ize " C"<br />

"D"<br />

60 GAL.<br />

80 GAL.<br />

662<br />

(26.06)<br />

725<br />

(28.56)<br />

368<br />

(14.50)<br />

432<br />

(17.0)<br />

SAFETY RELIEF VALVE<br />

MAINTAIN 31 BAR (450 PSI)<br />

ABOVE PUMP COMPENSATOR<br />

CONTROL SETTING<br />

REMOTE PUMP<br />

COMPENSATOR<br />

CONTROL ADJUSTMENT<br />

TOPPLATE<br />

LIFTING EYE<br />

TYP.-3 PLCS.<br />

CLEAN-OUT<br />

COVER<br />

PUMP CASE<br />

FILL PORT<br />

PRESSURE GUAGE<br />

WITH SHUT-OFF VALVE<br />

"A"<br />

V-PAK<br />

FULL MARK<br />

"C"<br />

"D"<br />

Ø15.9 (.625)<br />

TYP. -4 PLCS.<br />

SAE-12<br />

TANK DRAIN<br />

952.5<br />

(37.5)<br />

990.6<br />

(39.0)<br />

63.5<br />

(2.50)<br />

711.2<br />

(28.0)<br />

769.5<br />

(31.36)<br />

878.6<br />

(34.59)<br />

68.6<br />

(2.70)<br />

Hydraulics<br />

B47<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

S5, S6, & S8 Option Manifolds<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

"S5 Option" "S6 Option"<br />

S5<br />

SUBPLATE OPTION<br />

FOR USE WITH D3W VALVE<br />

(NFPA D05)<br />

S6<br />

SUBLATE OPTION<br />

FOR USE WITH D31VW VALVE<br />

(NFPA DO5H(E) W/ SAE-4<br />

"X" & "Y" PORTS)<br />

T P<br />

T P<br />

71.4<br />

(2.81)<br />

2.81<br />

(71.4)<br />

38.1<br />

(1.50)<br />

"X"- DO5HE<br />

"Y"- DO5H<br />

"X"- DO5H<br />

"Y"- DO5HE<br />

38.1<br />

(1.50)<br />

A-D03<br />

B-D05<br />

B-D03<br />

A-D05<br />

A-D03<br />

B-D05<br />

B-D03<br />

A-D05<br />

SUPPLY<br />

PORT<br />

SAE-12<br />

RETURN<br />

P<br />

PORT X<br />

SAE-12<br />

RETURN<br />

PORT<br />

SAE-12<br />

X<br />

X<br />

PUMP<br />

SUPPLY<br />

RETURN<br />

PORT<br />

SAE-12<br />

T<br />

X<br />

26.9<br />

(1.06)<br />

P<br />

T<br />

A<br />

B<br />

D05<br />

MNTG<br />

SURFACE<br />

"A"<br />

PORT<br />

SAE-10<br />

"B"<br />

PORT<br />

SAE-10<br />

54.1<br />

(2.13)<br />

SUPPLY<br />

PORT<br />

SAE-12<br />

RETURN<br />

P<br />

PORT X<br />

SAE-12<br />

RETURN<br />

PORT<br />

SAE-12<br />

X<br />

X<br />

PUMP<br />

SUPPLY<br />

X<br />

26.9<br />

(1.06)<br />

RETURN<br />

PORT<br />

SAE-12<br />

T<br />

P<br />

T<br />

X Y<br />

A<br />

B<br />

X Y<br />

D05<br />

MNTG<br />

SURFACE<br />

X<br />

X<br />

X<br />

X<br />

"A"<br />

PORT<br />

SAE-10<br />

"B"<br />

PORT<br />

SAE-10<br />

54.1<br />

(2.13)<br />

"S8 Option"<br />

S8<br />

SUBLATE OPTION<br />

FOR USE WITH D61VW VALVE<br />

(NFPA DO8 W/ SAE-6<br />

"X" & "Y" PORTS)<br />

16.5<br />

(.65)<br />

A<br />

X<br />

B<br />

P<br />

RETURN<br />

PORT<br />

SAE-16<br />

X<br />

T<br />

P<br />

T<br />

X<br />

X<br />

A<br />

B<br />

X<br />

Y<br />

"A"<br />

PORT<br />

SAE-16<br />

"B"<br />

PORT<br />

SAE-16<br />

PUMP<br />

SUPPLY<br />

Hydraulics<br />

B48<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

M5, M6 & M8 Option Manifolds<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

"M5 Option" "M6 Option"<br />

T P<br />

71.4<br />

(2.81)<br />

M5*<br />

MULTISTATION MANIFOLD OPTION<br />

FOR USE WITH D3W VALVES<br />

(NFPA D05)<br />

T<br />

P<br />

61.2<br />

(2.41)<br />

M6*<br />

MULTISTATION MANIFOLD OPTION<br />

FOR USE WITH D31VW VALVES<br />

(NFPA D05H, NO "X" & "Y" PORTS)<br />

B<br />

82.6 (3.25)<br />

PER STATION<br />

165.1<br />

(6.50)<br />

UP TO 5<br />

STATIONS<br />

B<br />

B<br />

G<br />

A<br />

A<br />

82.6<br />

(3.25)<br />

82.6 (3.25)<br />

PER STATION<br />

165.1<br />

(6.50)<br />

UP TO 5<br />

STATIONS<br />

B<br />

B<br />

G<br />

A<br />

A<br />

82.6<br />

(3.25)<br />

26.9<br />

(1.06)<br />

54.1<br />

(2.13)<br />

39.6<br />

(1.56)<br />

25.4<br />

(1.00)<br />

57.2<br />

(2.25)<br />

41.1<br />

(1.62)<br />

"G"<br />

SAE-6<br />

"M8 Option"<br />

G<br />

P<br />

PUMP<br />

SUPPLY<br />

RETURN<br />

PORT<br />

SAE-12<br />

X<br />

T<br />

A<br />

B<br />

A<br />

D05 B<br />

MNTG<br />

SURFACE<br />

M8*<br />

MULTISTATION MANIFOLD OPTION<br />

FOR USE WITH D61VW VALVES<br />

(NFPA D08, NO "X" PORT SAE-8 "Y" PORT)<br />

133.4<br />

(5.25)<br />

"A" & "B" PORT<br />

SAE-8<br />

(UP TO 5 STATIONS)<br />

46.0<br />

(1.81)<br />

"G"<br />

SAE-6<br />

G<br />

P<br />

PUMP<br />

SUPPLY<br />

"G"<br />

SAE-6<br />

X<br />

G<br />

P<br />

PUMP<br />

SUPPLY<br />

RETURN<br />

PORT<br />

SAE-16<br />

T A<br />

B<br />

A<br />

D08 B<br />

MNTG<br />

SURFACE<br />

RETURN<br />

PORT<br />

SAE-16<br />

X<br />

T<br />

A<br />

B<br />

A<br />

D05H B<br />

MNTG<br />

SURFACE<br />

"A" & "B" PORT<br />

SAE-16<br />

(UP TO 3 STATIONS)<br />

"A" & "B" PORT<br />

SAE-12<br />

(UP TO 5 STATIONS)<br />

266.7<br />

(10.50)<br />

UP TO 3<br />

STATIONS<br />

133.4<br />

(5.25)<br />

26.9<br />

(1.06)<br />

66.8<br />

(2.63)<br />

50.8<br />

(2.00)<br />

Hydraulics<br />

B49<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

V-Pak - Compensator Options<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

"OMIT" OPTION<br />

SINGLE PRESSURE<br />

REMOTE COMPENSATOR<br />

"B" OPTION<br />

SINGLE PRESSURE<br />

REMOTE COMPENSATOR<br />

W/LOW PRESS STANDBY<br />

T<br />

HIGH<br />

PSI<br />

LOW<br />

PSI<br />

LOW SOL<br />

STANDBY<br />

PUMP CASE<br />

PRE-FILL PORT<br />

P<br />

SAE<br />

-6<br />

AUX.VENT PORT (SAE-6)<br />

P<br />

PUMP COMPENSATOR<br />

CONTROL ADJUSTMENT<br />

T<br />

PUMP CASE<br />

PRE-FILL PORT<br />

P<br />

HIGH<br />

SOL<br />

SOLENOID IS 120 VAC(LOW WATT)<br />

WITH DIN.43650 CONNECTOR<br />

AND MANUAL OVERRIDE<br />

LOW PRESS.STANDBY(N.O.)<br />

ENERGIZE TO BUILD PRESSURE<br />

PUMP COMPENSATOR<br />

CONTROL ADJUSTMENT<br />

HI<br />

SOL<br />

LO<br />

SOL<br />

LO<br />

HI<br />

"C" OPTION<br />

BI-PRESSURE<br />

REMOTE COMPENSATOR<br />

T<br />

HIGH<br />

PSI<br />

LOW<br />

PSI<br />

"D" OPTION<br />

BI-PRESSURE<br />

REMOTE COMPENSATOR<br />

W/LOW PRESS STANDBY<br />

T<br />

HIGH<br />

PSI<br />

LOW<br />

PSI<br />

LOW SOL<br />

STANDBY<br />

P<br />

HIGH<br />

SOL<br />

P<br />

HIGH<br />

SOL<br />

PUMP CASE<br />

PRE-FILL PORT<br />

SOLENOID IS 120 VAC (LOW WATT)<br />

WITH DIN.43650 CONNECTOR<br />

AND MANUAL OVERRIDE<br />

HIGH PRESS.SOLENOID (N.O.)<br />

ENERGIZE FOR HIGH PRESSURE<br />

PUMP CASE<br />

PRE-FILL PORT<br />

SOLENOIDS ARE 120 VAC (LOW WATT)<br />

WITH DIN.43650 CONNECTOR<br />

AND MANUAL OVERRIDE<br />

HIGH PRESS. SOLENOID (N.O.)<br />

ENERGIZE FOR HIGH PRESSURE<br />

PUMP COMPENSATOR<br />

HIGH PRESS.CONTROL<br />

LOW PRESS. STANDBY (N.O.)<br />

ENERGIZE FOR LOW PRESSURE<br />

HI<br />

SOL<br />

LO<br />

SOL<br />

HI<br />

SOL<br />

LO<br />

SOL<br />

HI<br />

HI<br />

LO<br />

LO<br />

PUMP COMPENSATOR<br />

LOW PRESS.CONTROL<br />

PUMP COMPENSATOR<br />

HIGH PRESS. CONTROL<br />

PUMP COMPENSATOR<br />

LOW PRESS. CONTROL<br />

"E" OPTION<br />

PROVISION FOR<br />

CUSTOMER SUPPLIED<br />

REMOTE COMPENSATOR<br />

P<br />

SAE-6<br />

37˚ FLARE<br />

P<br />

T<br />

T<br />

P<br />

T<br />

PUMP COMPENSATOR<br />

PRESSURE (INLET) PORT<br />

PUMP COMPENSATOR<br />

TANK (RETURN) PORT<br />

PUMP CASE<br />

PRE-FILL PORT<br />

SAE-6 37˚ FLARE "P" & "T" PORTS<br />

ATTACH POINTS FOR CUSTOMER<br />

SUPPLIED REMOTE COMPENSATOR<br />

Hydraulics<br />

B50<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Accessory Options<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

HEAT EXCHANGER<br />

RETURN FILTER<br />

PRESSURE SWITCH<br />

BREATHER<br />

MULTI-STATION<br />

MANIFOLD<br />

PRESSURE FILTER<br />

TEMP. SWITCH<br />

TEMP/LEVEL<br />

SWITCH<br />

B<br />

SCHEMATIC - BASIC UNIT<br />

WITH ACCESSORIES<br />

EXAMPLE OF VARIOUS<br />

ACCESSORIES INSTALLED<br />

FOR REFERENCE ONLY<br />

SEE<br />

COMPENSATOR<br />

OPTIONS<br />

A B OPTION<br />

W*<br />

P<br />

SEE MANIFOLD<br />

OPTIONS<br />

T<br />

H<br />

L<br />

M<br />

N<br />

V<br />

G<br />

M<br />

K<br />

D<br />

E<br />

OR<br />

SEE<br />

COMPENSATOR<br />

OPTIONS<br />

S*<br />

M<br />

SEE<br />

COMPENSATOR<br />

OPTIONS<br />

F<br />

Z<br />

R*<br />

Y<br />

J<br />

C OPTION<br />

SAE<br />

-12<br />

X<br />

HYDRAULIC SCHEMATIC<br />

ACCESSORY OPTIONS - V PAKS<br />

OPTION A COOLING LOOP (0.8 HP REMOVAL)<br />

OPTION B COOLING LOOP (1.5 HP REMOVAL)<br />

OPTION C SYSTEM COOLING/FILTER LOOP (4.5 HP REMOVAL)<br />

OPTION D RETURN LINE WATER/OIL HEAT EXCHANGER<br />

OPTION E RETURN LINE WATER/OIL HEAT EXCHANGER<br />

OPTION F WATER TEMPERATURE MODULATING VALVE<br />

OPTION G RETURN LINE AIR/OIL HEAT EXCHANGER<br />

OPTION H PRESSURE FILTER<br />

OPTION J IMMERSION HEATER<br />

OPTION K PUMP OUTLET CHECK VALVE<br />

OPTION L BYPASS CHECK-RETURN HT. EX. ONLY<br />

OPTION M RETURN FILTER-SINGLE ELEMENT<br />

OPTION N RETURN FILTER-DUAL ELEMENT<br />

OPTION R* COMBINATION LEVEL/TEMPERATURE SWITCH<br />

OPTION S* FILTER RESERVOIR BREATHER<br />

OPTION V SPIN-ON RETURN FILTER<br />

OPTION W* PRESSURE SWITCH<br />

OPTION Y LEVEL SWITCH<br />

OPTION Z TEMPERATURE SWITCH<br />

Hydraulics<br />

B51<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


SAFETY RELIEF<br />

DO NOT ADJUST<br />

SAFETY RELIEF<br />

DO NOT ADJUST<br />

Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Dimensions - Accessories<br />

V8 reservoir with "Omit" manifold shown<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

Ordering Note: Units with PVP76 pumps and requiring options "A", "B" or "C" can only be ordered with<br />

V8 (302.8 L/80 Gal.) reservoir.<br />

HEAT REMOVAL<br />

HEAT REMOVAL<br />

O PTION A .6 KW (.80 HP* )<br />

O PTION B 1.1 KW (1.5 HP* )<br />

*Performance data are based on 100SSU oil leaving the cooler 4°C (40°F) higher than the ambient air temperature used for cooling.<br />

PUMP PRIME<br />

PUMP PRIME<br />

PUMP COMPENSATOR<br />

CONTROL<br />

PUMP COMPENSATOR<br />

CONTROL<br />

T<br />

T<br />

P<br />

P<br />

129.8<br />

(5.11)<br />

85.9<br />

(3.38)<br />

V-PAK<br />

V-PAK<br />

Option "A" Cooling Loop<br />

5.6 KW - 18.6 KW (7.5 HP - 25 HP) ONLY<br />

Option "B" Cooling Loop<br />

Hydraulics<br />

B52<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


OUT<br />

IN<br />

SAFETY RELIEF<br />

DO NOT ADJUST<br />

Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Dimensions - Accessories<br />

V8 reservoir with "Omit" manifold shown<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

Ordering Note: Units with PVP76 pumps and requiring options "A", "B" or "C" can only be ordered with<br />

V8 (302.8 L/80 Gal.) reservoir.<br />

HEAT REMOVAL<br />

O PTION C 3.4 KW (4.5 HP* )<br />

*Performance data are based on 100SSU oil leaving the cooler 4°C (40°F) higher than the ambient air temperature used for cooling.<br />

B<br />

PUMP PRIME<br />

PUMP COMPENSATOR<br />

CONTROL<br />

T<br />

P<br />

415.3<br />

(16.35)<br />

V-PAK<br />

Option "C" System Cooling/Filter Loop<br />

Hydraulics<br />

B53<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


q<br />

OUT<br />

IN<br />

SAFETY RELIEF<br />

DO NOT ADJUST<br />

Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Dimensions - Accessories<br />

V8 reservoir with "Omit" manifold shown<br />

Inch equivalents for millimeters dimensions are shown in (**)<br />

"S1" OPTION<br />

12 AT FILTER<br />

"S2" OPTION<br />

12 AT FILTER<br />

OPTION "G"<br />

HEAT EXCH.<br />

AIR FLOW<br />

OPTION "D" OR "E"<br />

WATER/OIL<br />

HEAT ECHANGER<br />

PUMP PRIME<br />

PUMP COMPENSATOR<br />

CONTROL<br />

T<br />

OPTION "R" OR "Y"<br />

COMBINATION TEMP/LEVEL<br />

SWITCH (1/2 NPT ELEC. CONN.) "OPTION W"<br />

PRESSURE SWITCH<br />

P<br />

OPTION "M", "N", OR<br />

"V" RETURN FILTER<br />

OPTION "H"<br />

PRESSURE FILTER<br />

OPTION "Z"<br />

TEMPERATURE SWITCH<br />

60˚-90˚F ADJ.<br />

V-PAK<br />

OPTION "F"<br />

WATER TEMP.<br />

ODULATING VALVE<br />

OPTION "J"<br />

IMMERSION<br />

HEATER<br />

195.6<br />

(7.7)<br />

Hydraulics<br />

B54<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Performance Data- Maximum Working Pressure<br />

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum<br />

relief valve or compensator setting.<br />

**** Represents maximum operating pressure with pump/motor combination. When used on power unit<br />

products this will represent a 207 bar (3000 psi) relief valve or compensator setting.<br />

B<br />

V-Pak - Pump/Motor Combinations Maximum Operating Pressure<br />

PUMP<br />

FLOW LPM (GPM)<br />

@ 1725 RPM<br />

5.6 KW<br />

(7.5 HP)<br />

7.5 KW<br />

(10 HP)<br />

11.2 KW<br />

(15 HP)<br />

14.9 KW<br />

(20 HP)<br />

18.6 KW<br />

(25 HP)<br />

22.3 KW<br />

(30 HP)<br />

29.8 KW<br />

(40 HP)<br />

P VP33 41.6 (11.0)<br />

75.2<br />

(1090)<br />

98.6<br />

(1430)<br />

146.9<br />

(2130)<br />

194.4<br />

(2820)<br />

239.2<br />

(3470)<br />

P VP33 43.5 (11.5)<br />

72.4<br />

(1050)<br />

95.1<br />

(1380)<br />

141.3<br />

(2050)<br />

186.8<br />

(2710)<br />

230.3<br />

(3340)<br />

P VP33 45.4 (12.0)<br />

69.6<br />

(1010)<br />

91.7<br />

(1330)<br />

135.8<br />

(1970)<br />

180<br />

(2610)<br />

222<br />

(3220)<br />

P VP33 47.3 (12.5)<br />

66.9<br />

(970)<br />

88.3<br />

(1280)<br />

131<br />

(1900)<br />

173.7<br />

(2520)<br />

213.7<br />

(3100)<br />

P VP33 49.2 (13.0)<br />

64.8<br />

(940)<br />

85.5<br />

(1240)<br />

126.9<br />

(1840)<br />

167.5<br />

(2430)<br />

206.8<br />

(3000)<br />

247.5<br />

(3590)<br />

P VP33 51.1 (13.5)<br />

62.7<br />

(910)<br />

82.7<br />

(1200)<br />

122.7<br />

(1780)<br />

162<br />

(2350)<br />

200<br />

(2900)<br />

239.2<br />

(3470)<br />

P VP33 52.9 (14.0)<br />

60.7<br />

(880)<br />

80<br />

(1160)<br />

118.6<br />

(1720)<br />

157.2<br />

(2280)<br />

193.7<br />

(2810)<br />

232.4<br />

(3370)<br />

P VP33 54.8 (14.5)<br />

59.3<br />

(860)<br />

77.9<br />

(1130)<br />

115.1<br />

(1670)<br />

152.4<br />

(2210)<br />

188.2<br />

(2730)<br />

224.8<br />

(3260)<br />

P VP33 56.7 (15.0)<br />

57.2<br />

(830)<br />

75.2<br />

(1090)<br />

111.7<br />

(1620)<br />

147.5<br />

(2140)<br />

182.7<br />

(2650)<br />

218.6<br />

(3170)<br />

Hydraulics<br />

B55<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Performance Data- Maximum Working Pressure<br />

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum<br />

relief valve or compensator setting.<br />

**** Represents maximum operating pressure with pump/motor combination. When used on power unit<br />

products this will represent a 207 bar (3000 psi) relief valve or compensator setting.<br />

V-Pak - Pump/Motor Combinations Maximum Operating Pressure<br />

PUMP<br />

FLOW LPM (GPM)<br />

@1725 RPM<br />

5.6 KW<br />

(7.5 HP)<br />

7.5 KW<br />

(10 HP)<br />

11.2 KW<br />

(15 HP)<br />

14.9 KW<br />

(20 HP)<br />

18.6 KW<br />

(25 HP)<br />

22.3 KW<br />

(30 HP)<br />

29.8 KW<br />

(40 HP)<br />

P VP48 58.6 (15.5)<br />

53.8<br />

(780)<br />

70.3<br />

(1020)<br />

103.4<br />

(1500)<br />

137.9<br />

(2000)<br />

170.3<br />

(2470)<br />

203.4<br />

(2950)<br />

270.2<br />

(3920)<br />

P VP48 60.5 (16.0)<br />

53.1<br />

(770)<br />

68.9<br />

(1000)<br />

101.4<br />

(1470)<br />

133.8<br />

(1940)<br />

166.2<br />

(2410)<br />

198.6<br />

(2880)<br />

263.4<br />

(3820)<br />

P VP48 62.4 (16.5)<br />

57.1<br />

(750)<br />

67.6<br />

(980)<br />

98.6<br />

(1430)<br />

130.3<br />

(1890)<br />

162<br />

(2350)<br />

193.1<br />

(2800)<br />

256.5<br />

(3720)<br />

P VP48 64.3 (17.0)<br />

50.3<br />

(730)<br />

65.5<br />

(950)<br />

96.5<br />

(1400)<br />

126.9<br />

(1840)<br />

157.9<br />

(2290)<br />

188.2<br />

(2730)<br />

249.6<br />

(3620)<br />

P VP48 66.2 (17.5)<br />

49<br />

(710)<br />

64.1<br />

(930)<br />

93.8<br />

(1360)<br />

124.1<br />

(1800)<br />

153.8<br />

(2230)<br />

183.4<br />

(2660)<br />

243.4<br />

(3530)<br />

P VP48 68.1 (18.0)<br />

48.3<br />

(700)<br />

62.8<br />

(910)<br />

91.7<br />

(1330)<br />

121.3<br />

(1760)<br />

150.3<br />

(2180)<br />

179.3<br />

(2600)<br />

237.9<br />

(3450)<br />

P VP48 70.0 (18.5)<br />

46.9<br />

(680)<br />

61.4<br />

(890)<br />

89.6<br />

(1300)<br />

118.6<br />

(1720)<br />

146.9<br />

(2130)<br />

175.1<br />

(2540)<br />

232.4<br />

(3370)<br />

P VP48 71.9 (19.0)<br />

46.2<br />

(670)<br />

60<br />

(870)<br />

87.6<br />

(1270)<br />

115.8<br />

(1270)<br />

143.4<br />

(2080)<br />

171<br />

(2480)<br />

226.8<br />

(3290)<br />

P VP48 73.8 (19.5)<br />

45.5<br />

(660)<br />

58.6<br />

(850)<br />

86.2<br />

(1250)<br />

113.1<br />

(1640)<br />

140<br />

(2030)<br />

167.5<br />

(2430)<br />

222<br />

(3220)<br />

P VP48 75.7 (20.0)<br />

44.1<br />

(640)<br />

57.2<br />

(830)<br />

84.1<br />

(1220)<br />

110.3<br />

(1600)<br />

137.2<br />

(1990)<br />

163.4<br />

(2370)<br />

216.5<br />

(3140)<br />

P VP48 77.6 (20.5)<br />

43.4<br />

(630)<br />

56.5<br />

(820)<br />

82<br />

(1190)<br />

108.2<br />

(1570)<br />

134.4<br />

(1950)<br />

160<br />

(2320)<br />

212.4<br />

(3080)<br />

P VP48 79.4 (21.0)<br />

42.7<br />

(620)<br />

55.2<br />

(800)<br />

80.7<br />

(1170)<br />

106.2<br />

(1540)<br />

131.7<br />

(1910)<br />

157.2<br />

(2280)<br />

206.8<br />

(3000)<br />

P VP48 81.3 (21.5)<br />

42.1<br />

(610)<br />

54.5<br />

(790)<br />

79.3<br />

(1150)<br />

104.1<br />

(1510)<br />

128.9<br />

(1870)<br />

153.8<br />

(2230)<br />

203.4<br />

(2950)<br />

P VP48 83.2 (22.0)<br />

41.4<br />

(600)<br />

53.8<br />

(780)<br />

77.9<br />

(1130)<br />

102<br />

(1480)<br />

126.2<br />

(1830)<br />

151<br />

(2190)<br />

199.3<br />

(2890)<br />

P VP48 85.1 (22.5)<br />

40.7<br />

(590)<br />

52.4<br />

(760)<br />

75.8<br />

(1100)<br />

100<br />

(1450)<br />

124.1<br />

(1800)<br />

147.5<br />

(2140)<br />

195.8<br />

(2840)<br />

P VP48 87.0 (23.0)<br />

40<br />

(580)<br />

51.7<br />

(750)<br />

74.5<br />

(1080)<br />

97.9<br />

(1420)<br />

121.3<br />

(1760)<br />

144.8<br />

(2100)<br />

191.7<br />

(2780)<br />

Hydraulics<br />

B56<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Performance Data- Maximum Working Pressure<br />

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum<br />

relief valve or compensator setting.<br />

**** Represents maximum operating pressure with pump/motor combination. When used on power unit<br />

products this will represent a 207 bar (3000 psi) relief valve or compensator setting.<br />

PUMP<br />

V-Pak - Pump/Motor Combinations Maximum Operating Pressure<br />

FLOW LPM (GPM)<br />

@ 1725 RPM<br />

5.6 KW<br />

(7.5 HP)<br />

7.5 KW<br />

(10 HP)<br />

11.2 KW<br />

(15 HP)<br />

14.9 KW<br />

(20 HP)<br />

18.6 KW<br />

(25 HP)<br />

22.3 KW<br />

(30 HP)<br />

29.8 KW<br />

(40 HP)<br />

B<br />

P VP76 90.8 (24.0)<br />

20.7<br />

(300)<br />

31.7<br />

(460)<br />

55.2<br />

(800)<br />

78.6<br />

(1140)<br />

100<br />

(1450)<br />

121.3<br />

(1760)<br />

167.2<br />

(2425)<br />

P VP76 94.6 (25.0)<br />

20<br />

(290)<br />

31<br />

(450)<br />

53.4<br />

(775)<br />

75.8<br />

(1100)<br />

96.5<br />

(1400)<br />

117.2<br />

(1700)<br />

160.3<br />

(2325)<br />

P VP76 98.4 (26.0)<br />

18.6<br />

(270)<br />

29.6<br />

(430)<br />

52.4<br />

(760)<br />

73.8<br />

(1070)<br />

94.5<br />

(1370)<br />

113.8<br />

(1650)<br />

155.8<br />

(2260)<br />

P VP76 102.2 (27.0)<br />

17.9<br />

(260)<br />

29.3<br />

(425)<br />

50.3<br />

(730)<br />

71<br />

(1030)<br />

91.4<br />

(1325)<br />

113.8<br />

(1650)<br />

155.8<br />

(2260)<br />

P VP76 106.0 (28.0)<br />

17.6<br />

(255)<br />

27.6<br />

(400)<br />

48.3<br />

(700)<br />

68.3<br />

(990)<br />

88.3<br />

(1280)<br />

106.5<br />

(1545)<br />

144.1<br />

(2090)<br />

P VP76 109.8 (29.0)<br />

17.2<br />

(250)<br />

26.9<br />

(390)<br />

46.5<br />

(675)<br />

65.5<br />

(950)<br />

86.9<br />

(1260)<br />

104.5<br />

(1515)<br />

140.7<br />

(2040)<br />

P VP76 113.6<br />

(30.0)<br />

-<br />

26.9<br />

(390)<br />

45.5<br />

(660)<br />

63.8<br />

(925)<br />

83.4<br />

(1210)<br />

103.4<br />

(1500)<br />

137.9<br />

(2000)<br />

P VP76 117.3<br />

(31.0)<br />

-<br />

25.9<br />

(375)<br />

43.8<br />

(635)<br />

61.4<br />

(890)<br />

80.7<br />

(1170)<br />

97.9<br />

(1420)<br />

132.4<br />

(1920)<br />

P VP76 121.1<br />

(32.0)<br />

-<br />

24.8<br />

(360)<br />

42.7<br />

(620)<br />

60.3<br />

(875)<br />

78.6<br />

(1140)<br />

95.1<br />

(1380)<br />

128.6<br />

(1865)<br />

P VP76 124.9<br />

(33.0)<br />

-<br />

23.4<br />

(-340)<br />

41.4<br />

(600)<br />

57.9<br />

(840)<br />

75.8<br />

(1100)<br />

92.4<br />

(1340)<br />

124.8<br />

(1840)<br />

P VP76 128.7<br />

(34.0)<br />

-<br />

22.4<br />

(325)<br />

39.6<br />

(575)<br />

56.9<br />

(825)<br />

74.1<br />

(1075)<br />

90.3<br />

(1310)<br />

121.7<br />

(1765)<br />

P VP76 132.5<br />

(35.0)<br />

-<br />

21.4<br />

(310)<br />

36.5<br />

(530)<br />

55.2<br />

(800)<br />

70.7<br />

(1025)<br />

87.9<br />

(1275)<br />

118.9<br />

(1725)<br />

P VP76 136.7<br />

(36.0)<br />

-<br />

20.7<br />

(300)<br />

35.2<br />

(510)<br />

53.1<br />

(770)<br />

68.9<br />

(1000)<br />

84.8<br />

(1230)<br />

111<br />

(1610)<br />

Hydraulics<br />

B57<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Performance Data<br />

Fluid Standard Hydraulics Oil 100 SSU @ 49°C (120°F)<br />

Flow, Horsepower and Efficiency Charts<br />

Efficiency - %<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

Flow<br />

LPM<br />

75.7<br />

68.2<br />

60.6<br />

53.0<br />

45.4<br />

37.9<br />

30.3<br />

22.7<br />

15.1<br />

7.6<br />

GPM<br />

20<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0 0<br />

Bar 0<br />

PSI 0<br />

PVP33 @ 1800 RPM<br />

69<br />

1000<br />

Volumetric Efficiency<br />

Overall Efficiency<br />

Flow<br />

Input Power at Full Flow<br />

Compensated Power<br />

138<br />

2000<br />

Pressure<br />

207<br />

3000<br />

KW<br />

29.8<br />

23.9<br />

17.9<br />

11.9<br />

6.0<br />

0<br />

275<br />

4000<br />

HP<br />

40.0<br />

32.0<br />

24.0<br />

16.0<br />

8.0<br />

0<br />

Power<br />

Efficiency - %<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

Flow<br />

LPM GPM<br />

90.9<br />

79.5<br />

68.1<br />

60.6<br />

45.4<br />

34.1<br />

22.7<br />

11.4<br />

24<br />

21<br />

18<br />

16<br />

12<br />

9<br />

6<br />

3<br />

0 0<br />

Bar 0<br />

PSI 0<br />

PVP48 @ 1800 RPM<br />

Flow<br />

Efficiency<br />

Full Flow Power<br />

Compensated Power<br />

69 138 207<br />

1000 2000 3000<br />

Pressure<br />

KW<br />

44.8<br />

33.6<br />

22.4<br />

11.2<br />

0<br />

275<br />

4000<br />

HP<br />

60.0<br />

45.0<br />

30.0<br />

15.0<br />

0<br />

Power<br />

100<br />

LPM GPM<br />

227.2 60<br />

PVP76 @ 1800 RPM<br />

Volumetric Efficiency<br />

KW<br />

119.4<br />

HP<br />

160.0<br />

NOTE: The efficiencies and data in the graph are<br />

good only for pumps running at 1800 RPM and stroked<br />

to maximum. To calculate approximate horsepower<br />

for the other conditions, use the following formula:<br />

Efficiency - %<br />

75<br />

50<br />

Flow<br />

170.4<br />

113.6<br />

56.8<br />

45<br />

30<br />

15<br />

0 0<br />

Bar 0<br />

PSI 0<br />

Flow<br />

69<br />

1000<br />

Overall Efficiency<br />

Full Flow Power<br />

Compensated Power<br />

138<br />

2000<br />

Pressure<br />

207<br />

3000<br />

89.5<br />

59.7<br />

29.8<br />

0<br />

275<br />

4000<br />

120.0<br />

80.0<br />

40.0<br />

0<br />

Power<br />

HP =[ Q x (PSI) ] + (CHp)<br />

1714<br />

Actual GPM is directly proportional to drive speed<br />

and maximum volume setting. Flow loss, however, is<br />

a function of pressure only.<br />

WHERE:<br />

Q = Actual Output Flow in GPM<br />

PSI = Pressure at Pump Outlet<br />

CHp = Input Horsepower @ Full Compensation @<br />

1800 RPM (from graph read at operating<br />

pressure)<br />

NOTE: Maximum input HP to the pump may exceed<br />

electric motor drive capability. Select motor size (HP)<br />

to exceed application requirements (HP).<br />

Hydraulics<br />

B58<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Technical Information<br />

HORSEPOWER REMOVED<br />

BY COOLER<br />

76<br />

(20)<br />

38<br />

(10)<br />

19<br />

(5)<br />

AIR COOLED<br />

OIL HEAT EXCHANGER<br />

227 & 303 LITER (60 & 80 GALLON) OPTION "G"<br />

26<br />

(7)<br />

30<br />

(8)<br />

34 38<br />

(9) (10)<br />

57<br />

(15)<br />

76<br />

(20)<br />

95<br />

(25)<br />

OIL FLOW-LPM (GPM)<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

114<br />

(30)<br />

151<br />

(40)<br />

"G" - Return Line HT. EX. 30 LPM - 136 LPM (8 GPM - 36 GPM MAX.)<br />

Performance data is based on 100 SSU oil leaving the cooler<br />

4.4°C (40°F) higher than the ambient air temperature used for cooling.<br />

189<br />

(50)<br />

OIL PRESSURE DROP<br />

AT 100 SSU<br />

= .34 BAR (5 PSI)<br />

= .69 BAR (10 PSI)<br />

= 1.0 BAR (15 PSI)<br />

= 1.4 BAR (20 PSI)<br />

B<br />

114 (30)<br />

OIL/WATER HEAT EXCHANGERS<br />

"D" OPTION (2:1 OIL/WATER RATIO)<br />

"E" OPTION (4:1 OIL/WATER RATIO)<br />

227 & 303 LITER (60 & 80 GALLON)<br />

95 (25)<br />

HORSEPOWER REMOVED<br />

BY COOLER<br />

76 (20)<br />

57 (15)<br />

38 (10)<br />

34 (9)<br />

30 (8)<br />

26 (7)<br />

23 (6)<br />

19 (5)<br />

15 (4)<br />

11 (3)<br />

8 (2)<br />

15<br />

(4)<br />

19<br />

(5)<br />

23<br />

(6)<br />

26 30 34 38<br />

(7) (8)(9)(10)<br />

"D"<br />

57<br />

(15)<br />

"E"<br />

76<br />

(20)<br />

95<br />

(25)<br />

OIL FLOW-LPM (GPM)<br />

114<br />

(30)<br />

151<br />

(40)<br />

189<br />

(50)<br />

OIL PRESSURE DROP<br />

AT 100 SSU<br />

= .34 BAR (5 PSI)<br />

= .69 BAR (10 PSI)<br />

"D" Option - Return line ht. ex. 30 LPM - 136 LPM (8.0 GPM - 36 GPM Max.) max. water flow not to exceed 45 LPM (12 GPM).<br />

"E" Option - Return line ht. ex. (15.0 GPM - 36 GPM Max.) max. water flow not to exceed 45 LPM (12 GPM).<br />

"---------" - Represents max. horsepower removal at max. pump flow rate.<br />

Heat removal is based on 4.4°C (40°F) differential between transfer medium using 29°C (85°F) cooling water.<br />

The oil/water ratio 2:1 means that for every 7.5 liters (2 gallons) of oil through the cooler, a minimum of 3.8 liters (1 gallon) of 29°C (85°F)<br />

water must be circulated to achieve curve results.<br />

RESERVOIR SIZE LITERS (GALLONS)<br />

227 (60)<br />

303 (80)<br />

Heat removal is based on static<br />

ambient air of 29°C (85°F) and max. oil<br />

temperature of 57°C (135°F).<br />

KW (HP) REMOVAL<br />

4.2 (1.1)<br />

4.5 (1.2)<br />

Hydraulics<br />

B59<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Ordering Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Omit If Not Omit If Not Omit If Not<br />

Required Required Required<br />

OR Reduced<br />

Flow W<br />

Reservoir Remote Pump Pump No Motor Electric Manifold<br />

Compensator Control Flow (See Note) Motor<br />

Options<br />

**<br />

Ordering<br />

Code<br />

Ordering<br />

Code<br />

Omit<br />

B<br />

C<br />

D<br />

E<br />

Reservoir Size<br />

(Gallons)<br />

V6 60<br />

V8 80<br />

Compensator<br />

Description<br />

Single Pressure<br />

Remote<br />

Compensator<br />

Single Pressure<br />

Remote<br />

Compensator With<br />

Low Pressure<br />

Standby<br />

Bi-Pressure Remote<br />

Compensator<br />

Bi-Pressure Remote<br />

Compensator With<br />

Low Pressure<br />

Standby<br />

Provision For<br />

Customer Supplied<br />

Remote Control<br />

Relief Valve<br />

* Consult factory for<br />

electrohydraulic pressure control<br />

and driver card options.<br />

Ordering<br />

Code<br />

Omit<br />

A*<br />

Pump Control<br />

Option<br />

Std. Remote<br />

Compensator<br />

Load Sense<br />

(Flow Control)<br />

* Unless otherwise<br />

specified, a SAE-6 37°<br />

flared port will be<br />

supplied for customer<br />

connection.<br />

When shuttle check<br />

option (7 or 8) is<br />

specified on S5, S6, or<br />

S8 manifold, sense<br />

line will be plumbed to<br />

shuttle check.<br />

** Consult factory for<br />

horsepower and hi-lo<br />

pump control options.<br />

Lead time is four<br />

weeks.<br />

Ordering<br />

Code<br />

OMIT<br />

S5<br />

Ordering Code<br />

M<br />

N<br />

P<br />

S<br />

Q<br />

R<br />

Motor Description (HP-RPM-Frame-Type)<br />

7 1 /2-1800-213TC-TEFC<br />

10-1800-215TC-TEFC<br />

15-1800-254TC-TEFC<br />

20-1800-256TC-TEFC<br />

25-1800-284TC-TEFC<br />

30-1800-286T-TEFC<br />

V<br />

40-1800-324T-TEFC<br />

Electric motors are 230/460V, 60Hz, 3PH. Consult factory<br />

for other motor speeds (RPM) and voltages.<br />

** Use “W” prefix when no motor is required on unit. When<br />

ordering, “W” must be followed by motor model code<br />

equivalent to frame size of motor to be used.<br />

**Example: V815WM***=80 Gallon reservoir, std PVP33 unit to<br />

accept a 7.5 HP/213TC C-face frame motor.<br />

Ordering Pump Flow Rate Pump Used and Description<br />

Code @ 1800 RPM<br />

15 15.6 PVP33 - Std. Remote Compensator<br />

23 23.0 PVP48 - Std. Remote Compensator<br />

36 36.1 PVP 76-STD Remote Compensator<br />

* Specify in GPM Destroked (Reduced) Flow<br />

* Unless otherwise specified, units are shipped at max. flow rate (GPM)<br />

at 1800 RPM. When reduced flow setting is required,<br />

Reduced flows from 22.5 to 8.0 GPM, specify in 0.5 GPM increments.<br />

Reduced flows from 35.0 to 24.0 GPM, specify in 1.0 GPM increments.<br />

Example: V*9.5**-- = PVP33 Pump Destroked to 9.5 GPM<br />

V*A31**-- = PVP76 Load Sense Pump Destroked to 31.0 GPM<br />

Pump Control/Mounting<br />

Pressure and Return Port Block with<br />

Safety Relief and Pump Compensator Control Valves<br />

D05 Single Station Subplate with<br />

Safety Relief and Pump Compensator Control Valves<br />

Supply/Return Port<br />

Actuator Port Size<br />

“P” Port SAE-16<br />

“T” Port SAE-20<br />

“A” & “B” Ports<br />

SAE-10 Str. Thr’d<br />

Other<br />

None<br />

None<br />

S6<br />

S8<br />

D05H/D05HE Single Station Subplate with “A” & “B” Ports “X” & “Y” Ports<br />

Safety Relief and Pump Compensator Control Valves SAE-10 Str. Thr’d SAE-4 Str. Thr’d<br />

D08 Single Station Subplate with “A” & “B” Ports “X” & “Y” Ports<br />

Safety Relief and Pump Compensator Control Valves SAE-16 Str. Thr’d SAE-6 Str. Thr’d<br />

Note:<br />

1. Manifolds are mounted<br />

vertically bottom station<br />

is number 1.<br />

2. M5 & M6 -2 thru 5 stations<br />

available M8-2 & 3 stations<br />

available. (Other manifolds-<br />

Consult factory)<br />

M5 *<br />

M6 *<br />

M8 *<br />

D05 Multistation Parallel Circuit Manifold with<br />

Safety Relief and Pump Compensator Control Valves<br />

D05H Multistation Parallel Circuit Manifold with<br />

Safety Relief and Pump Compensator Control Valves<br />

“A” & “B” Ports<br />

SAE-8 Str. Thr’d<br />

“A” & “B” Ports<br />

SAE-12 Str. Thr’d<br />

None<br />

None<br />

D08 Multistation Parallel Circuit Manifold with “A” & “B” Ports “Y” Port<br />

Safety Relief and Pump Compensator Control Valves SAE-16 Str. Thr’d SAE-8 Str. Thr’d<br />

* When ordering Multi-Station Manifolds, the number of stations must be specified. If valves are to be mounted,<br />

specify the valves and sequence, if the model code exceeds 25 digits, utilize the special ordering code X.<br />

Example: V615QM53EFG4<br />

Example: V615QM54B1B1CB4<br />

3 Station D05 Manifold 4. Station D05 Manifold<br />

Station #1: E Station #1: B1<br />

Station #2: F Station #2: B1<br />

Station #3: G4 Station #3: C<br />

Station #4: B4<br />

Hydraulics<br />

B60<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

➤<br />

Catalog HY13-1552-001/NA,EU<br />

Ordering Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Omit If Not Omit If Not Omit If Not Omit If Not Not Required<br />

Required Required Required Required When Ordering<br />

P X<br />

Directional Manapak Accessories Special Modifications<br />

Control Valve<br />

Control Valves<br />

Indicates special modification has been specified.<br />

Design Series<br />

Order<br />

Code<br />

Function<br />

Model<br />

Number<br />

Technical<br />

Data<br />

Ordering<br />

Code<br />

Ordering<br />

Code<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7*<br />

Valve NFPA Nominal<br />

Circuit<br />

Function Model Mounting Flow LPM Symbol<br />

Number Pad (GPM)<br />

Flow Control<br />

(Meter Out)<br />

Flow Control<br />

(Meter Out)<br />

Pilot Operator<br />

Check<br />

Pilot Operator<br />

Check<br />

“P” Port Pressure PRM3PA25KN<br />

Reducing (150-3500)<br />

“P” Port Pressure PRM6PA25KN<br />

Reducing (150-3000)<br />

Shuttle Check<br />

(Load Sense)<br />

Valve NFPA Nominal Solenoid<br />

Model Mounting Flow LPM Operator<br />

Number Pad (GPM) -110 VAC<br />

A D3W20BNYK D05 78 (20)<br />

B D3W1CNYK D05 78 (20)<br />

C D3W4CNYK D05 57 (15)<br />

D D3W20DNYK D05 78 (20)<br />

E D31VW20B4NYCF D05H 78 (20)<br />

F D31VW1C4NYCF D05H 78 (20)<br />

G D31VW4C4NYCF D05H 78 (20)<br />

H D31VW20D4NYCF D05H 78 (20)<br />

J D61VW1B4NYCF D08 189 (50)<br />

K D61VW1C4NYCF D08 189 (50)<br />

L D61VW4C4NYCF D08 189 (50)<br />

M D61VW1D4NYCF D08 189 (50)<br />

FM3DDKN D05 45 (12)<br />

FM6DDKN D08 151 (40)<br />

CPOM3DDN D05 45 (12)<br />

CPOM6DDN D08 189 (50)<br />

Single<br />

(Spr. Ret)<br />

Double<br />

(Spr. Ctr)<br />

Double<br />

(Spr. Ctr)<br />

Double<br />

(Detent)<br />

Single<br />

(Spr. Ret)<br />

Double<br />

(Spr. Ctr)<br />

Double<br />

(Spr. Ctr)<br />

Double<br />

(Detent)<br />

Single<br />

(Spr. Ret)<br />

Double<br />

(Spr. Ctr)<br />

Double<br />

(Spr. Ctr)<br />

Double<br />

(Detent)<br />

N Cover Plate D05 – –<br />

R Cover Plate D08 – –<br />

D05 45 (12)<br />

D08 189 (50)<br />

– D05 –<br />

Circuit<br />

Symbol<br />

A B<br />

P T<br />

A B<br />

P T<br />

A B<br />

P T<br />

A B<br />

P T<br />

A B<br />

P T<br />

A B<br />

P<br />

A B<br />

P T<br />

A B<br />

P T<br />

A<br />

P<br />

A B<br />

P T<br />

A B<br />

P T<br />

A<br />

P<br />

A B<br />

P T<br />

A B<br />

P T<br />

T<br />

B<br />

T<br />

B<br />

T<br />

Pressure<br />

Filter<br />

30P210QM250NN-1<br />

-VALVE-<br />

-ACTUATOR-<br />

A B<br />

-VALVE-<br />

-ACTUATOR-<br />

A B<br />

P<br />

-SUPPLY-<br />

-VALVE-<br />

Shuttle Check<br />

8*<br />

– D08 –<br />

(Load Sense)<br />

-VALVE-<br />

* Use in combination with load sense pump control “A” and<br />

flow control valve option (1 or 2).<br />

Manapak valves mounted in order of callout. First valve will be nearest DCV;<br />

last valve will be on manifold.<br />

-ACTUATOR-<br />

A<br />

B<br />

T<br />

LS<br />

A**<br />

B**<br />

C**<br />

D<br />

E<br />

F<br />

G<br />

H<br />

J<br />

K<br />

L<br />

M<br />

N<br />

R1<br />

R2<br />

S1<br />

S2<br />

V<br />

W1<br />

W2<br />

Y<br />

Z<br />

Continuous<br />

Cooling<br />

Continuous<br />

Cooling<br />

Filter Cooling<br />

Loop<br />

Oil/Water<br />

Heat Exchanger<br />

Oil/Water<br />

Heat Exchanger<br />

Water Temp.<br />

Modulating<br />

Valve<br />

Air Cooled<br />

Oil Heat<br />

Exchanger<br />

RM-08-2-2<br />

RM-19-2-2<br />

AOC-22-2-1PH<br />

40CN205Q<br />

N701B6F<br />

EKS-708-T<br />

V47AC-6<br />

AOVH-15-3PH<br />

Immersion<br />

Heater<br />

Check Valve<br />

Pump Outlet<br />

KB-3T2-0193-M1<br />

Bypass<br />

Check<br />

C2020S65<br />

Return<br />

Filter<br />

Return<br />

Filter<br />

Combination<br />

Float/Temp. SW<br />

N.O. Float Up<br />

Combination<br />

Float/Temp. SW<br />

N.C. Float Up<br />

12AT Canister<br />

Breather<br />

Triceptor<br />

Breather<br />

Return<br />

Filter<br />

Pressure Switch<br />

10-160 BAR<br />

(150-2320 PSI)<br />

Pressure Switch<br />

25-248 BAR<br />

(360-3600 PSI)<br />

*Air/Oil: Max<br />

Oil Flow 17 LPM (4.5 GPM)<br />

.6 KW (.8 HP) Heat Rejection<br />

*Air/Oil: Max<br />

Oil Flow 17 LPM (4.5 GPM)<br />

1.1 KW (1.5 HP) Heat Rejection<br />

*Air/Oil W1 PH Motor<br />

Max Oil Flow 32 LPM (8.5 GPM)<br />

3.3 KW (4.5 HP) Heat Rejection<br />

Oil/Water (2:1)<br />

Max.95 LPM ( 25 GPM)<br />

Oil/Water (4:1)<br />

Max. 144 LPM (38 GPM)<br />

24°-57°C (75°F-135°F) Adj. Range<br />

Cross Ambient Sensing<br />

3/4" NPT Inlet<br />

Air Cooled-3 Phase<br />

Motor 9 KW (12 HP) Removal<br />

@ Max. 136 LPM (36 GPM)<br />

10 Micron-Microglass<br />

Dual Element<br />

Mech. Indicator<br />

3KW-480V-3PH<br />

-17°-38°C (0°-100°F) ADJ.<br />

W/Thermostat<br />

493-16-D1-2<br />

.3 BAR (5 PSI) Cracking Pressure<br />

40CN110Q<br />

40CN210Q<br />

877501<br />

877502<br />

4.5 BAR (65 PSI) Cracking Pressure<br />

10 Micron Microglass<br />

Single Element Mech. Indicator<br />

***(13 PSID)<br />

10 Micron Microglass<br />

Dual Element Mech. Indicator<br />

*** (8 PSID)<br />

Fixed Temp @ 65°C (149°F)<br />

Close @ Low Level<br />

and/or 65°C (149°F) (N.C.)<br />

Fixed Temp. @ 65°C (149°F)<br />

Open @ Low Level<br />

and/or 65°C (149°F) (N.C.)<br />

926169<br />

2 Micron Cellulose Media<br />

934331<br />

Silica Gel Desiccant<br />

50AT10CN1500LI<br />

876731-03<br />

876731-02<br />

Cellulose Element Ind.<br />

Guage-1 BAR (15 PSI) Bypass<br />

132 LPM (35 GPM) Max. Oil Flow<br />

N.O. & N.C. Contacts<br />

(SPDT Switch)<br />

DIN 43650 Connector<br />

N.O. & N.C. Contacts<br />

(SPDT Switch)<br />

DIN 43650 Connector<br />

Level<br />

Switch<br />

877004<br />

Open @ Low Level<br />

Adjustable<br />

Temperature<br />

Switch<br />

837-A4A NEMA 1<br />

16°-88°C (60°F-190°F) Range<br />

Adjust.<br />

Differential N.O. & N.C. Contacts<br />

* Heat rejection data are based on 100SSU oil leaving the cooler 4°C (40°F)<br />

higher than the ambient air temperature used for cooling.<br />

**Units with PVP76 pumps and requiring options "A", "B" or "C" can only be<br />

ordered with V8 (302.8 L/80 Gal.) reservoir.<br />

Option "A" available from 5.6 KW (7.5 HP) thru 18.5 KW (25 HP)<br />

Option "C" not available with option "A" or "B".<br />

***Based on max 136 LPM (36 GPM) w/ 150SUS oil.<br />

B<br />

Hydraulics<br />

B61<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee


Catalog HY13-1552-001/NA,EU<br />

Installation Information<br />

Low Profile Power Units<br />

Volume Control Series V-Paks<br />

Operating Notes<br />

• Jog the electric motor once and verify that the<br />

electric motor is rotating in the same direction as<br />

the arrow on the electric motor housing. If direction<br />

is incorrect, reverse two of the three leads on a 3-<br />

phase electric motor.<br />

• V-Pak power units are tested and pressure control<br />

valves are factory preset. If adjustments are needed,<br />

follow the procedure below: Begin adjusting relief<br />

valve and pump compensator control valve to<br />

increase pressure gradually. (NOTE: Always set relief<br />

valve 28-31 bar (400-450 psi) higher than pump<br />

compensator pressure control valve or severe<br />

overheating will occur.)<br />

• If pump fails to prime, vent pump discharge to<br />

atmosphere to establish fluid flow.<br />

• Reservoir temperature should not exceed 66°C<br />

(150°F). System reliability and component service<br />

life will be reduced when system is operated at<br />

higher temperature.<br />

• Clean fluid = improved system reliability and longer<br />

component service life, change filter elements<br />

whenever filter indicators indicate a dirty element<br />

condition.<br />

• It is recommended that every 4,000 operating hours<br />

or once a year, whichever occurs first, the filler/<br />

breather cap and suction strainer should be replaced.<br />

Fluid Recommendations<br />

Premium quality hydraulic oil with a viscosity range<br />

between 150-250 SSU (30-50 cst.) at 38°C (100°F).<br />

Normal operating viscosity range between 80-1000 SSU<br />

(17-180 cst.). Maximum start-up viscosity is 4000 SSU<br />

(1000 cst.).<br />

NOTE: Consult Parker when exceeding 71°C (160°F)<br />

operation. Oil should have maximum anti-wear<br />

properties, rust and oxidation treatment.<br />

Filtration<br />

For maximum pump and system component life, the<br />

system should be protected from contamination at a<br />

level not to exceed 125 particles greater than 10 microns<br />

per milliliter of fluid. (SAE Class 4 / ISO 16/13.) Due to<br />

the nature of variable displacement pumps, variations<br />

in pump inlet conditions, fluid acceleration losses,<br />

system aeration, and duty cycle must be carefully<br />

considered before specifying suction line filtration.<br />

Contact your Parker representative for assistance.<br />

Hydraulics<br />

B62<br />

Parker Hannifin Corporation<br />

Hydraulic Pump/Motor Division<br />

Greeneville, Tennessee

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!