12.09.2015 Views

Product note Nuovo Retrofitting kit SACE Modul – Tmax / Tmax XT

Brochure - Nuova Orsud

Brochure - Nuova Orsud

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Product</strong> <strong>note</strong><br />

<strong>Nuovo</strong> <strong>Retrofitting</strong> <strong>kit</strong><br />

<strong>SACE</strong> <strong>Modul</strong> <strong>–</strong> <strong>Tmax</strong> / <strong>Tmax</strong> <strong>XT</strong><br />

Conversion Kit <strong>Modul</strong><strong>–</strong> <strong>Tmax</strong>/ <strong>Tmax</strong> <strong>XT</strong><br />

È possibile sostituire la vecchia serie di interruttori <strong>Modul</strong><br />

rimovibili dal SN160 al SH400 con l’ultima serie <strong>Tmax</strong> e<br />

<strong>Tmax</strong> <strong>XT</strong> utilizzando il nuovo <strong>kit</strong> di retrofitting.<br />

Attraverso un <strong>kit</strong> di conversione si modifica l’interruttore<br />

fisso con terminali frontali e dotato di relè elettronico<br />

(rispettivamente Ekip per <strong>XT</strong>4 e PR22x per T5) in una<br />

speciale parte mobile.<br />

Un <strong>kit</strong> di adattamento consente la connessione tra la parte<br />

mobile speciale e la parte fissa del <strong>Modul</strong> già esistente:<br />

<strong>XT</strong>4S e <strong>XT</strong>4H fino a 250A con I1 fino a 250A<br />

T5N e T5H fino a 400A con I1 fino a 400A<br />

L’interruttore <strong>Tmax</strong>/ <strong>Tmax</strong> <strong>XT</strong>, alimentato dai terminali<br />

superiori, può essere corredato di tutti i numerosi accessori<br />

di cui è dotata la famiglia <strong>Tmax</strong>/ <strong>Tmax</strong> <strong>XT</strong>.<br />

<strong>Modul</strong><br />

Non occorre prevedere alcuna operazione di smontaggio della parte<br />

fissa esistente: grazie a questa soluzione, unica nel suo genere, i<br />

tempi di fuori servizio sono minimi e limitati alla singola utenza.<br />

<strong>Nuovo</strong> interruttore <strong>Tmax</strong> T/ <strong>Tmax</strong> <strong>XT</strong><br />

Interruttore<br />

Poli Esecuzione<br />

Tipologia di <strong>kit</strong><br />

Interruttore con relè<br />

elettronico<br />

Esecuzione<br />

da<br />

ordinare<br />

Codice d'ordine<br />

del <strong>kit</strong><br />

Preassemblato<br />

da ABB<br />

<strong>SACE</strong><br />

<strong>Modul</strong> SN 160 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SN 160 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SN 250 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SN 250 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SN 400 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SN 400 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 100 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 100 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 125 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 125 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 160 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 160 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 250 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 250 4p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 400 3p Rimovibile REPLACEMENT --><br />

<strong>Modul</strong> SH 400 4p Rimovibile REPLACEMENT --><br />

F F = fisso con terminali anteriori<br />

<strong>XT</strong>4S 160A (con Ekip…) F F + 1SDA069459R1 SI<br />

<strong>XT</strong>4S 160A (con Ekip…) F F + 1SDA069460R1 SI<br />

<strong>XT</strong>4S 250A (con Ekip…) F F + 1SDA069459R1 SI<br />

<strong>XT</strong>4S 250A (con Ekip…) F F + 1SDA069460R1 SI<br />

T5N 400A (con PR22x) F F + 1SDA069463R1 SI<br />

T5N 400A (con PR22x) F F + 1SDA069464R1 SI<br />

<strong>XT</strong>4H 160A (con Ekip…) F F + 1SDA069457R1 SI<br />

<strong>XT</strong>4H 160A (con Ekip…) F F + 1SDA069458R1 SI<br />

<strong>XT</strong>4H 160A (con Ekip…) F F + 1SDA069457R1 SI<br />

<strong>XT</strong>4H 160A (con Ekip…) F F + 1SDA069458R1 SI<br />

<strong>XT</strong>4H 160A (con Ekip…) F F + 1SDA069461R1 SI<br />

<strong>XT</strong>4H 160A (con Ekip…) F F + 1SDA069462R1 SI<br />

<strong>XT</strong>4H 250A (con Ekip…) F F + 1SDA069461R1 SI<br />

<strong>XT</strong>4H 250A (con Ekip…) F F + 1SDA069462R1 SI<br />

T5H 400A (con PR22x) F F + 1SDA069465R1 SI<br />

T5H 400A (con PR22x) F F + 1SDA069466R1 SI<br />

Per maggiori informazioni contattare:<br />

ABB <strong>SACE</strong><br />

A division of ABB S.p.A.<br />

L.V. Breakers<br />

Via Baioni, 35<br />

24123 Bergamo - Italy<br />

Tel.: +39 035 395 111<br />

Fax: +39 035 395306-433<br />

www.abb.com<br />

Page 2 of 2<br />

Prduct <strong>note</strong>_<strong>Modul</strong> - <strong>Tmax</strong> IT.doc

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!