108"<br />

<strong>TECHNICAL</strong> <strong>DATA</strong><br />

<strong>Elevator</strong> Qty. 1<br />

Type<br />

Traction MRL Gearless 2:1 /HDC<br />

Rated load / Weight Cab<br />

<strong>Co</strong>unterweight<br />

Surface<br />

750 LBS / 1600 lbs<br />

1975 lbs<br />

12 Sq Ft<br />

Persons<br />

Voltage 220 / 1 /60<br />

Speed<br />

Operation<br />

50 ft per min.<br />

Automatic<br />

Leveling Type<br />

Automatic<br />

Limits Switches<br />

OMRON<br />

Landings / Openings ______/______<br />

Hositway Doors<br />

Automatic<br />

Car Rails<br />

8 lbs/ft – 11.9 kg/m<br />

Cwt Rails Unistrut 1” X 1 5/8”<br />

Type of Guide<br />

Rollers<br />

Cab Steadier<br />

Fixe<br />

<strong>Co</strong>ntroller GT-Tektronic SRX 500<br />

<strong>Co</strong>ntroller Type<br />

Microprocessor<br />

Car Safety Type<br />

SAFGT01<br />

CWT Safety Type N/A<br />

Car Governor:<br />

Type<br />

PFB R5R Type with contact<br />

Cable ¼”<br />

Tripping Speed 61.2 ft per min. 0.24m/s<br />

CWT Governor:<br />

Type<br />

N/A<br />

Cable<br />

N/A<br />

Tripping Speed N/A<br />

Car Sheave Diameter 12”<br />

Cwt Sheave Diameter 12”<br />

Cables<br />

2 Cables 3/8” Class 8x19<br />

Breaking Strength 13,570 lbs / 6169 kg<br />

Security Factor 14.8<br />

<strong>MACHINE</strong> <strong>DATA</strong><br />

Machine<br />

Machine Capacity 4600 lbs<br />

Motor Speed (rpm)<br />

Motor Data (v/ph/hz) 220 / 3 / 60<br />

Motor Starting<br />

amp<br />

Motor Full Load<br />

6.5amps<br />

Motor HP<br />

¾ HP<br />

Drive Sheave 11 ¼ ”<br />

Emergency Brake On Machine<br />

Rope Pitch 0.625”<br />

Transformer BTU N/A<br />

<strong>Co</strong>ntrol Space Total BTU BTU/H<br />

Hoistway Total BTU/H BTU/H<br />

Notes:<br />

GTMO1-14-30<br />

8" [203.20]<br />

_____<br />

_______________________<br />

<strong>Universal</strong> <strong>Elevator</strong> <strong>Co</strong>.<br />

P.O. Box 848 1-800-547-0747<br />

452 Yacht Club Dr. Fax: 1-877-810-7806<br />

Rockwall, TX 75087 USA<br />

452A Yacht Club Dr P.O.Box 848 Rockwall,Texas 75087<br />

Toll Free1-800-547-0747 972-722-8001<br />

_____<br />

This drawing is the property of UEC. It is furnished only<br />

for information purpose on a confidential basic, and neither<br />

the drawing or items thereon be reproduce or used in any<br />

manner not authorized in writing by a corporate officer.<br />

_______________________<br />

REV” Date: Description BY<br />

Drawing Name:<br />

Details:<br />

Project Name:<br />

Address:<br />

<strong>Elevator</strong> Layout<br />

Entrance Front & Rear<br />

UEC MAG LULA F & R<br />

With Safety SAFGT01<br />

O<br />

R<br />

__________________________<br />

<strong>Universal</strong> <strong>Elevator</strong><br />

Specializing in Custom <strong>Elevator</strong>s<br />

http://www.universalelevator.com<br />

Drawing by: Check by: Date: Scale: N.T.S.<br />

Ref: Drawing # Sheets: Rev:


Hoistway <strong>Co</strong>nstruct ion Notes<br />

<strong>Universal</strong> <strong>Elevator</strong><br />

______________________________________________________________<br />

Specializing in Custom <strong>Elevator</strong>s<br />

http://www.universalelevator.com/<br />

• A load bearing wall is required to sustain rail reactions.<br />

See Rail Reac tions and Guide Rail Backing <strong>Co</strong>nstruction below.<br />

• All points of the pit floor must be a minimum of 8" below the lower landing finish floor(12" if optional bufer springs are used).<br />

• Hoistway pit ßoor construction should consist of an 8" concrete slab poured on a natural or compacted soil with<br />

a minimum allowable bearing pressure of 1.0 K S F. T he minimum compressive strength of the concrete at 28<br />

days must be no less than 3000 P S I. #5 reinforcing steel (grade 60) must be placed at the bottom of the slab in<br />

2 traverse directions and at a spacing of 12".<br />

• Hoistway pit ßoor must resist a dynamic force of 6400 lbs.<br />

• 108" overhead clearance required above the top landing F inish . F loor.<br />

• Hoistway sizes reflect running and acc ess clearances only. <strong>Co</strong>nsult your local authority to assure compliance with state and<br />

local codes.<br />

• Minimum overhead clearance is 108" above the top landing finished floor<br />

(Optional 84" car height requires 112", 96" car height requires 124").<br />

• Due to limited clearance it is imperative that the walls are square and plumb throughout the hoistwa.y The finished hoistway<br />

must be within 1 /4" tolerance from top to bottom.<br />

• Hoistway door provided by others. We recommend a 3'-0" x 6'-8 " door.<br />

Automatic doors by UEC.<br />

• Hoistway is requir ed to be f ree of all pipes, wiring and obstructions not related to the operation of the <strong>Elevator</strong>. .<br />

• Service access hatch is required in the controller / drive assembly area.<br />

• Building structure must provide for a means of a chain hoist for hoisting rail and elevator materials to the top of the hositway<br />

during installation.<br />

Guide Rail Backing <strong>Co</strong>nstruction Details:<br />

• Laminate (2) 2x12’s and (2) 2x4’ s with glue and #8 x 2 1 /4"<br />

wood screws (minimum).<br />

• Overlap joints of the lumber as necessary for structural<br />

rigidity.<br />

• Guide rail backing must be tied to a horizontal structure<br />

member (header or floor plate) at top, bottom and a<br />

maximum of 10' between.<br />

Rail Reactions<br />

R 1 = 210 LBF.<br />

R 2 = 543 LBF.<br />

O<br />

R<br />

t 452A Yacht Club Dr. P.O.Box 848 Rockwall,Texas 75087 USA<br />

Toll Free.1-800-547-0747 1-972-722-8001<br />

Sales1@universalelevator.com<br />

Rail reactions do not include safety factors. Applicable<br />

safety factors must be considered in hoistway design.<br />

Wall attachment pull-out force is 147 LBF. per fastener.<br />

12"<br />

3"<br />

2x4<br />

3"<br />

2x12’s<br />

2x4<br />

Space screws 12"<br />

vertically and 3" on<br />

each side of centerline<br />

of 2x12<br />

Wall Board<br />

-Shown partially


<strong>Co</strong>mpany:<br />

Attention of:<br />

Telephone:<br />

<strong>Universal</strong> <strong>Elevator</strong><br />

______________________________________________________________<br />

Fax:<br />

E-Mail:<br />

O<br />

R<br />

Specializing in Custom <strong>Elevator</strong>s<br />

http://www.universalelevator.com/<br />

t 452A Yacht Club Dr. P.O.Box 848 Rockwall,Texas 75087 USA<br />

Toll Free.1-800-547-0747 1-972-722-8001<br />

MRL MAG-LUX Gearless <strong>Elevator</strong><br />

To:<br />

Request Date:<br />

Quote required date:<br />

Sales1@universalelevator.com<br />

Job Name<br />

Location:<br />

Check your <strong>Elevator</strong> <strong>Co</strong>nfiguration<br />

Hoistway<br />

l<br />

l<br />

l<br />

l<br />

l<br />

l l<br />

l<br />

9' -0" [2743mm]<br />

8" [381mm]<br />

Q<br />

Required selections to complete <strong>Elevator</strong> design<br />

**Car sizes<br />

36" x 54" 36" x 48"<br />

Maximum 18 sq. ft.<br />

l<br />

illustrations shown below.<br />

I<br />

750 lbs (340 kg) 950 lbs(430 kg)