LargeFixture<br />

OrderInformation<br />

1 2 3 4 5 6 7<br />

Fixture Decorative Style <strong>Globe</strong> Style Optical System Lamp/Ballast Options Color<br />

FGL RB SLG CCO 100MH ALF BLK<br />

1. fixture<br />

FGL<br />

3. GLOBE STYLE<br />

6. Options<br />

<strong>Federal</strong> <strong>Globe</strong> Large. Post top mount.<br />

Slips over a 5"/125mm O.D. pole<br />

LL3 Lindy ® Lens <strong>Globe</strong> type 3. Not available with CCO. (Max 250 watt)<br />

LL5 Lindy ® Lens <strong>Globe</strong> type 5. Not available with CCO. (Max 250 watt)<br />

PA3 Prismatic Acorn <strong>Globe</strong> type 3.<br />

PA5 Prismatic Acorn <strong>Globe</strong> type 5.<br />

SLG Standard Lens <strong>Globe</strong>. Only available with CCO. Two piece globe.<br />

SAL Standard Acorn <strong>Globe</strong>. One piece globe. Available with LED.<br />

5. LAMP/BALLAST<br />

55LED-BW 42 LED array. (52.4 total input watts) Bright white (5000K).<br />

Class 1, 120 thru 277 volt.<br />

100MH 100 watt metal halide 120/208/240/277 volt ballast.<br />

Use a medium base, ED-17 lamp<br />

150PSMH Pulse start 150 watt metal halide 120/208/240/277 volt ballast.<br />

Use medium base, ED-17 lamp.<br />

200PSMH Pulse Start 200 watt metal halide 120/208/240/277<br />

volt ballast. Use mogul base, ED-28 lamps*.<br />

Not available with GR3 or GR5<br />

250PSMH Pulse Start 250 watt metal halide 120/208/240/277<br />

volt ballast. Use mogul base, ED-28 lamps*.<br />

Not available with GR3 or GR5<br />

320PSMH Pulse Start 320 watt metal halide 120/208/240/277<br />

volt ballast. Use mogul base, ED-28 lamp*.<br />

Not available with GR3 or GR5<br />

350PSMH Pulse Start 350 watt metal halide 120/208/240/277<br />

volt ballast. Use mogul base, ED-28 lamp*.<br />

Not available with GR3 or GR5<br />

400PSMH Pulse Start 400 watt metal halide 120/208/240/277<br />

volt ballast. Use mogul base, ED-28 lamp*.<br />

Not available with GR3 or GR5<br />

FS1 Single Fuse Holder (fuse by others)<br />

FS2 Double Fuse Holder (fuse by others)<br />

347 347 volt ballast (120/277/347V)<br />

ASY Asymmetric reflector - field installed. For CCO only.<br />

HSS House side shield, field installed. Includes asymmetric assembly<br />

For CCO only.<br />

TA3 Tenon adaptor slips over a 3"/75mm o.d. by 4"/100mm long.<br />

Secures to the pole with four stainless steel set screws<br />

TA4 Tenon adaptor slips over a 4"/100mm O.D. by 4"/100mm<br />

long. Secures to the pole with four stainless steel set screws<br />

2. DECORATIVE STYLE<br />

RB<br />

LF<br />

Rib Fitter Design<br />

Leaf Fitter Design<br />

4. OPTICAL SYSTEM<br />

T3<br />

T5<br />

CCO<br />

GR3<br />

GR5<br />

BLO<br />

Type 3 distribution. LED only.<br />

Type 5 distribution. LED only.<br />

ContraCline® Optic<br />

Type 3 distribution. Glass Refractor Optic (max 150PSMH & 150HPS)<br />

Type 5 distribution. Glass Refractor Optic (max 150PSMH & 150HPS)<br />

Bare Lamp Optic<br />

70HPS 70 watt high pressure sodium 120/208/240/277<br />

volt ballast. Use medium base, ED-17 lamp.<br />

100HPS 100 watt high pressure sodium 120/208/240/277<br />

volt ballast. Use medium base, ED-17 lamp.<br />

150HPS 150 watt high pressure sodium 120/208/240/277<br />

volt ballast. Use medium base, ED-17 lamp.<br />

250HPS 250 watt high pressure sodium multitap ballast<br />

120/208/240/277 volt. Use mogul base ED-18 lamp.<br />

Not available with GR3 or GR5<br />

400HPS 400 watt high pressure sodium multitap ballast<br />

120/208/240/277 volt. Use mogul base ED-18 lamp.<br />

Not available with GR3 or GR5<br />

IL55 55 watt induction lamp system with high frequency generator.<br />

Specify 120, 208, 240 or 277 volt. -25°C start temp. For BLO only.<br />

IL85 85 watt induction lamp system with high frequency generator.<br />

Specify 120, 208, 240 or 277 volt. -25°C start temp. For BLO only.<br />

*For all Pulse Start Ballasts be certain to use lamps rated for vertical burning<br />

All ballasts are factory wired for 277 volts, unless specified. Lamps not included.<br />

All applicable ballasts are EISA compliant.<br />

TA23<br />

ALF<br />

COS<br />

PHC<br />

Tenon adaptor slips over a 2 3/8" o.d. by 4" long.<br />

Secures to the pole with four stainless steel set screws.<br />

Cast filigree basket. For SLG globe only.<br />

Cut off shield - reduces uplight. Factory installed.<br />

(Not available with GR3 or GR5).<br />

Photo control kit. Not available for 347V ballast.<br />

Specify line voltage.<br />

7. COLOR<br />

All standard AAL colors available.<br />

For RAL & custom colors, please submit a four-digit RAL number or color chip for custom colors.<br />