Hearing Solutions Catalog
Hearing Solutions Catalog - Precise Hearing
Hearing Solutions Catalog - Precise Hearing
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Spring 2009<br />
<strong>Hearing</strong> <strong>Solutions</strong> <strong>Catalog</strong><br />
S Series | E Series | Earmolds | Vents
Contents<br />
Introduction. ............................................... 1<br />
S Series <strong>Hearing</strong> Instruments<br />
S Series and Drive Architecture Introduction. .................... 4<br />
S Series Feature Summary. .................................... 6<br />
S Series Feature Chart. ...................................... 10<br />
S Series RIC <strong>Hearing</strong> Instruments<br />
S Series RIC................................................ 14<br />
S Series RIC Technical Specifications .. . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />
S Series RIC AP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
S Series RIC AP Technical Specifications. ........................ 20<br />
S Series Custom <strong>Hearing</strong> Instruments<br />
S Series Custom <strong>Hearing</strong> Instruments............................ 24<br />
S Series Custom <strong>Hearing</strong> Instruments Technical Specifications .. . . . . . . 26<br />
E Series <strong>Hearing</strong> Instruments<br />
E Series Introduction......................................... 30<br />
E Series RIC Technical Specifications .. . . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />
E Series RIC AP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
E Series RIC AP Technical Specifications. ........................ 35<br />
E Series Custom <strong>Hearing</strong> Instruments. .......................... 37<br />
E Series Custom <strong>Hearing</strong> Instruments Technical Specifications .. . . . . . . 38<br />
Earmold Selections<br />
Earmold Style Versus <strong>Hearing</strong> Loss.............................. 42<br />
Factors to Consider When Choosing Materials. ................... 42<br />
Custom Earmold Colors .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
Available Materials .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />
Custom Earmold Materials.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
Custom Earmold Styles....................................... 45<br />
Venting Guide<br />
Venting Options .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Today’s advances in multi-core, open<br />
architecture technology are making it possible<br />
for Starkey to invent hearing solutions more<br />
powerful and precise than ever before.<br />
More important, our next generation hearing<br />
instruments are creating broader appeal among<br />
a new generation of hearing professionals<br />
who place equal emphasis on technology and<br />
design for their patients. Why sacrifice when<br />
you can have it all?<br />
1
S Series<br />
<strong>Hearing</strong> Instruments<br />
<strong>Hearing</strong> System<br />
S Series and Drive Architecture Introduction 4<br />
S Series Feature Summary 6<br />
S Series Feature Chart 10
S Series<br />
<strong>Hearing</strong> Instruments<br />
S Series<br />
The Most Complete,<br />
Advanced Line of <strong>Hearing</strong> Instruments<br />
Thanks to Drive Architecture and the extraordinary new<br />
features it makes possible, S Series is the most complete<br />
and advanced line of hearing instruments, designed to fit the<br />
widest range of patients and lifestyles.<br />
4
Drive Architecture<br />
Proven Performance.<br />
Maximum Everything.<br />
At the heart of every S Series hearing instrument is Starkey’s<br />
newest, state-of-the-art integrated circuit platform, Drive<br />
Architecture, designed to deliver maximum performance,<br />
maximum power and maximum patient satisfaction.<br />
Powered by multi-core technology, Drive Architecture utilizes<br />
independent and fully programmable open architecture<br />
processors that efficiently carry out tasks in parallel by<br />
utilizing simultaneous multi-threading technology (SMT).<br />
Drive Architecture triples the processing power of previous<br />
platforms, allowing for super efficient, high-speed<br />
multitasking of signal processing algorithms for better<br />
performance. All this, while significantly improving battery life<br />
over our previous technology platform.<br />
5
S Series<br />
Feature Summary<br />
S Series boasts Starkey’s newest, best-in-class features, so your<br />
patients can experience more with superior comfort, greater clarity,<br />
improved directionality and speech audibility.<br />
Starkey’s industry-leading PureWave Feedback Eliminator puts S Series in a<br />
class all its own with more robust feedback cancellation and intelligent artifact<br />
elimination to ensure your patients get the best possible performance in every<br />
listening environment.<br />
Acoustic Scene Analyzer (ASA) is Starkey’s newest integrated system for<br />
maximizing performance in noise and preserving speech recognition. Able to<br />
instantly classify incoming signals based on unique acoustic characteristics,<br />
ASA can seamlessly select and implement the most appropriate algorithms<br />
individually or collectively, resulting in the best possible acoustic response at<br />
every moment in time. The result is the highest level of patient comfort and<br />
clarity in noise while emphasizing speech preservation.<br />
Based on clinical performance measures and patient proven results<br />
InVision Directionality, our industry-leading directional system, is designed<br />
to better perform in highly complex backgrounds of noise. S Series boasts the<br />
highest mean DI scores and the lowest operational noise floor, helping patients<br />
significantly increase their understanding in noise.<br />
In addition to superior directionality, Starkey’s new acoustic pattern recognition<br />
system, AudioScape, with patented, real-time environment detection and<br />
classification, adapts to any listening environment by seamlessly adjusting to<br />
the patient’s preferred settings. An important part of this patented classification<br />
process includes a channel-specific signal-to-noise ratio calculation to ensure<br />
that speech is always given priority.<br />
Starkey was the first company to integrate real-ear measurement into a hearing<br />
aid. Now Live Real Ear Measurement in the S Series takes this capability<br />
to the next level. With this system and the power of Inspire ® fitting software,<br />
you can see the hearing aid output in your patient’s ear, in real-ear SPL, while<br />
the system evaluates the hearing aid response and matches to your selected<br />
target – providing you with the most precise fitting information available.<br />
6
T 2 is a new breakthrough technology from Starkey that allows your patients<br />
to control their hearing aids using any cell or touch-tone phone, avoiding the<br />
need to carry additional hardware. T 2 discreetly and instantly classifies the<br />
touch-tone signal and automatically adjusts.<br />
Voice Indicators alert your patient to the status of their hearing aid, low<br />
battery, memory and telephone modes in their choice of male or female voices<br />
in a wide variety of languages.<br />
Self Check allows you and your patients to perform a diagnostic check of the<br />
microphone, circuit and receiver by opening and closing the battery door three<br />
times. This information is then retained for you to view and use in counseling.<br />
Reminder offers you the option of programming audible voice or tone<br />
reminders for follow-up appointments and maintenance checks.<br />
Automatic Telephone <strong>Solutions</strong> (ATS) automatically detects telephone use<br />
and adjusts to the optimal acoustic frequency response for telephone listening.<br />
Music & Television Performance offers new memory programs designed for<br />
optimal performance for two of the most important environments based on<br />
patient feedback.<br />
With Inspire 2009 you now have a more personal, accurate way to fit and<br />
counsel your patient including enhanced Live Real Ear Measurement,<br />
Live Speech Mapping and e-STAT. A precise fitting is critical to creating<br />
successful patient outcomes, which is why this system is integrated into all<br />
S Series models and technology levels.<br />
Live 3D Speech Mapping allows you to verify how the hearing aid processes<br />
speech, or any live acoustic input, in real time. Additionally, the Live Speech<br />
Mapping display engages the patient and family in the fitting process, resulting<br />
in greater understanding and acceptance.<br />
7
S Series<br />
Feature Summary, cont’d<br />
With Lifestyle <strong>Solutions</strong>, you can discuss the various environments your<br />
patients experience throughout their daily lives to help determine the<br />
technology level that is most appropriate for their lifestyle.<br />
Let patients and their loved ones experience the impact hearing loss can<br />
have by giving a live demonstration with our <strong>Hearing</strong> Loss Simulator, which<br />
has been enhanced to feature writing tools that allow you to draw or make<br />
comments directly on the screen that can be printed out for your patients.<br />
Surround Town continues to be the best breakthrough audio simulator of<br />
its time and gives your patients a deeper understanding of real-world listening<br />
environments and challenges.<br />
8
9
Vibrant<br />
Active<br />
Sound Imaging<br />
PureWave Feedback<br />
Eliminator<br />
Optimal high-resolution sound<br />
imaging with frequency shaping<br />
in all 16 channels and 16 bands<br />
High-resolution sound imaging<br />
with frequency shaping in<br />
12 channels and 12 bands<br />
Acoustic Scene Analyzer Premium Advanced<br />
AudioScape Precision<br />
Comfort Control<br />
16-channel<br />
environmental adaptation<br />
12-channel<br />
environmental adaptation<br />
AudioScape<br />
Environments<br />
6 5<br />
Speech<br />
Machine Noise<br />
Speech and Noise<br />
Wind<br />
Other Noise<br />
Quiet<br />
Adaptation Levels 5 4<br />
Time Constant Adjustability<br />
InVision Directionality<br />
Automatic Telephone <strong>Solutions</strong><br />
T 2 (Touch-Tone)<br />
Live Real Ear Measurements<br />
3D Live Speech Mapping<br />
Live Speech Mapping<br />
Leisure Listening<br />
Music<br />
4 genres<br />
TV<br />
Reminder<br />
Indicators<br />
Level-Dependent Speech<br />
Level-Dependent Tone<br />
Self Check<br />
In-Situ Audiometry<br />
Auto Path<br />
Verify Comfort<br />
Data Logging<br />
Memories 4 4<br />
10
Social<br />
Calm<br />
Frequency shaping in<br />
8 channels and 8 bands<br />
6 channels and 6 bands<br />
Select<br />
8-channel<br />
environmental adaptation<br />
Standard<br />
6-channel<br />
environmental adaptation<br />
3 (on/off) 3 (on/off)<br />
4 4<br />
11
RIC <strong>Hearing</strong> Instruments<br />
S Series RIC 14<br />
S Series RIC Technical Specifications 16<br />
S Series RIC AP 18<br />
S Series RIC AP Technical Specifications 20<br />
S Series RIC<br />
<strong>Hearing</strong> Instruments
S Series RIC<br />
A RIC for Every Wearer,<br />
Every <strong>Hearing</strong> Loss<br />
S Series RIC<br />
<strong>Hearing</strong> Instruments<br />
The S Series is the first full receiver-in-canal (RIC)<br />
product line to offer a beautiful, comfortable option for<br />
all levels of hearing loss – from mild to severe.<br />
The extraordinary power and performance of Drive<br />
Architecture allows you to quickly and accurately fit<br />
more patients than ever before with a receiver-in-canal<br />
hearing solution that offers unparalleled feedback<br />
cancellation, directionality, environmental adaptation<br />
and comfort. When fit open, S Series has the widest<br />
fitting range and most usable high-frequency bandwidth<br />
of any open fit instrument in its class.<br />
14
FEATURES<br />
S Series RIC<br />
RIC 40 110/40<br />
RIC 50 115/50<br />
Maximum Output<br />
Up to 30dB Reduction in 2dB Steps<br />
(range varies by channel)<br />
Compression Threshold<br />
24dB Range in 4dB Steps<br />
Compression Ratio<br />
1:1 – 3:1<br />
(range varies by channel)<br />
Power-on Delay<br />
Standard<br />
Color Guide<br />
Sterling<br />
Champagne<br />
Slate<br />
Pearl<br />
Bronze<br />
Onyx<br />
15
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
RIC<br />
Receiver-In-Canal<br />
11 • 9 • 7 • 5<br />
S Series RIC 40 Gain Receiver<br />
S Series RIC 40 – 2cc<br />
0<br />
60<br />
OSPL90<br />
FOG 50<br />
120<br />
10<br />
20<br />
30<br />
50<br />
110<br />
40<br />
50<br />
60<br />
40<br />
100<br />
70<br />
80<br />
30<br />
90<br />
90<br />
100<br />
110<br />
20<br />
80<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
70<br />
100 1000 10000<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
S Series RIC 40 with open earbud<br />
(light blue), occluded earbud<br />
(dark blue), and custom occluded<br />
earmold (gray) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the S Series RIC at 110/40.<br />
S Series RIC 50 Gain Receiver<br />
S Series RIC 50 – 2cc<br />
0<br />
60<br />
OSPL90<br />
FOG 50<br />
120<br />
10<br />
20<br />
30<br />
50<br />
110<br />
40<br />
50<br />
40<br />
100<br />
60<br />
70<br />
80<br />
30<br />
90<br />
90<br />
100<br />
20<br />
80<br />
110<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
70<br />
100 1000 10000<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
S Series RIC 50 with open earbud<br />
(light blue), occluded earbud<br />
(dark blue), and custom occluded<br />
earmold (gray) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the S Series RIC at 115/50.<br />
Measurement Conditions and Recommendations<br />
The data for S Series are obtained and performance is expressed according to ANSI S3.22 (2003), IEC 60118-7<br />
(2005) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer as<br />
well as the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment.<br />
Data may be subject to change with product refinement.<br />
Because of the adaptive signal processing capabilities of S Series hearing instruments, the hearing instrument<br />
must be set to test mode to compare the actual performance of the hearing instrument with these specifications.<br />
S Series hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting<br />
the “<strong>Hearing</strong> Aid Test” screen from the menu on the left side of the Inspire window, then selecting the<br />
“Full On Gain” button.<br />
RF IMMUNITY LEVEL: These hearing instruments have a cell phone immunity rating of M4. For your cell phone<br />
to be compatible with these hearing instruments, the cell phone needs an immunity rating of M1 or higher.<br />
Please consult your cell phone specifications for your cell phone immunity rating.<br />
16
S Series RIC<br />
ANSI/IEC Data<br />
40 Gain Data 50 Gain Data<br />
Measurement<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
Peak OSPL90 (dB SPL) 110 122 115 126<br />
HFA OSPL90 (dB SPL) 102 NA 108 NA<br />
RTF OSPL90 (dB SPL) NA 110 NA 116<br />
Peak Gain (dB) 40 51 50 61<br />
HFA Full-On Gain (dB) 31 NA 44 NA<br />
RTF Full-On Gain (dB) NA 39 NA 51<br />
Frequency Range (Hz) 100 - 7900 NA 100 - 7300 NA<br />
Reference Test Frequency (kHz) NA 1.6 NA 1.6<br />
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA<br />
Reference Test Gain (dB) 26 32 31 41<br />
Harmonic Distortion<br />
500 Hz (%)
S Series RIC AP<br />
ABSOLUTE POWER<br />
Our newest innovation is the S Series AP – our<br />
Absolute Power hearing instrument – the best<br />
performing, most powerful RIC on the market.<br />
S Series AP is patient proven and offers<br />
between 60 and 71dB of peak gain. Now even<br />
your patients with severe hearing loss can enjoy<br />
the discreet style, design and comfort of a RIC<br />
without sacrificing power and performance.<br />
18
FEATURES<br />
S Series RIC AP<br />
RIC 60 123/60<br />
RIC 71 131/71<br />
Maximum Output<br />
Up to 30dB Reduction in 2dB Steps<br />
(range varies by channel)<br />
Compression Threshold<br />
24dB Range in 4dB Steps<br />
Compression Ratio<br />
1:1 – 3:1<br />
(range varies by channel)<br />
Power-on Delay<br />
Standard<br />
Color Guide<br />
Sterling<br />
Champagne<br />
Slate<br />
Pearl<br />
Bronze<br />
Onyx<br />
19
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
RIC AP<br />
Receiver-In-Canal<br />
11 • 9 • 7 • 5<br />
S Series RIC AP 60 Gain Receiver<br />
S Series RIC AP 60 – 2cc<br />
0<br />
70<br />
OSPL90<br />
FOG 50<br />
130<br />
10<br />
20<br />
60<br />
120<br />
30<br />
40<br />
50<br />
50<br />
110<br />
60<br />
70<br />
80<br />
90<br />
100<br />
110<br />
40<br />
30<br />
20<br />
100<br />
90<br />
80<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
100 1000 10000<br />
70<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
S Series RIC AP 60 with custom<br />
occluded earmold fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the S Series RIC AP at 123/60.<br />
S Series RIC AP 71 Gain Receiver<br />
S Series RIC AP 71 – 2cc<br />
0<br />
OSPL90<br />
FOG 50<br />
10<br />
70<br />
130<br />
20<br />
30<br />
60<br />
120<br />
40<br />
50<br />
50<br />
110<br />
60<br />
70<br />
80<br />
90<br />
100<br />
110<br />
40<br />
30<br />
20<br />
100<br />
90<br />
80<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
100 1000 10000<br />
70<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
S Series RIC AP 71 with custom<br />
occluded earmold fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the S Series RIC AP at 131/71.<br />
Measurement Conditions and Recommendations<br />
The data for S Series are obtained and performance is expressed according to ANSI S3.22 (2003), IEC 60118-7<br />
(2005) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer as<br />
well as the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment.<br />
Data may be subject to change with product refinement.<br />
Because of the adaptive signal processing capabilities of S Series hearing instruments, the hearing instrument<br />
must be set to test mode to compare the actual performance of the hearing instrument with these specifications.<br />
S Series hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting<br />
the “<strong>Hearing</strong> Aid Test” screen from the menu on the left side of the Inspire window, then selecting the<br />
“Full On Gain” button.<br />
RF IMMUNITY LEVEL: These hearing instruments have a cell phone immunity rating of M4. For your cell phone<br />
to be compatible with these hearing instruments, the cell phone needs an immunity rating of M1 or higher.<br />
Please consult your cell phone specifications for your cell phone immunity rating.<br />
20
S Series RIC AP<br />
ANSI/IEC Data<br />
60 Gain Data 71 Gain Data<br />
Measurement<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
Peak OSPL90 (dB SPL) 123 130 131 139<br />
HFA OSPL90 (dB SPL) 115 NA 125 NA<br />
RTF OSPL90 (dB SPL) NA 127 NA 136<br />
Peak Gain (dB) 60 69 71 79<br />
HFA Full-On Gain (dB) 52 NA 64 NA<br />
RTF Full-On Gain (dB) NA 63 NA 75<br />
Frequency Range (Hz) 100 - 5400 NA 100 - 5300 NA<br />
Reference Test Frequency (kHz) NA 1.6 NA 1.6<br />
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA<br />
Reference Test Gain (dB) 39 52 48 61<br />
Harmonic Distortion<br />
500 Hz (%)
Custom <strong>Hearing</strong> Instruments<br />
S Series Custom <strong>Hearing</strong> Instuments 24<br />
S Series Custom <strong>Hearing</strong> Instruments Technical Specifications 26<br />
S Series Custom<br />
<strong>Hearing</strong> Instruments
S Series<br />
Custom <strong>Hearing</strong><br />
Instruments<br />
As the recognized expert in custom hearing instruments,<br />
Starkey has integrated breakthrough features directly<br />
into hearing instruments and fitting software so even<br />
our custom hearing instruments are built for maximum<br />
comfort and guaranteed to fit the first time.<br />
S Series Custom<br />
<strong>Hearing</strong> Instruments<br />
Our master craftsmanship in custom fittings and<br />
proprietary open vent options combined with our<br />
industry-leading feedback cancellation result in<br />
custom instruments that deliver an accurate fitting<br />
with superior comfort and performance on patients<br />
you never thought possible.<br />
24
FEATURES<br />
S Series Custom <strong>Hearing</strong> Instruments<br />
ITE Up to 131/71<br />
HS/ITC Up to 131/71<br />
CIC Up to 131/71<br />
Maximum Output<br />
Up to 20dB Reduction in 2dB Steps<br />
(range varies by channel)<br />
Compression Threshold<br />
24dB Range in 4dB Steps<br />
Compression Ratio<br />
1:1 – 3:1<br />
(range varies by channel)<br />
Power-on Delay<br />
Standard<br />
Color Guide<br />
Faceplate Colors<br />
Pink<br />
Light Brown<br />
Medium Brown<br />
Chestnut<br />
Dark Brown<br />
Shell Colors<br />
Pink<br />
Light Brown<br />
Clear<br />
Blue/Red<br />
Dark Brown<br />
25
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
FOG 50 (dB)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
OSPL90 (dBSPL)<br />
ITE, HS, ITC, CIC<br />
In-The-Ear, Half-Shell,<br />
In-The-Canal, Completely-In-Canal<br />
11 • 9 • 7 • 5<br />
S Series Custom Products Fitting Ranges<br />
S Series ITC 71 – 2cc<br />
0<br />
80<br />
OSPL90<br />
FOG 50<br />
140<br />
10<br />
20<br />
30<br />
70<br />
130<br />
40<br />
50<br />
60<br />
120<br />
60<br />
70<br />
80<br />
50<br />
110<br />
90<br />
100<br />
40<br />
100<br />
110<br />
120<br />
250 500 1K 2K 4K 8K<br />
30<br />
90<br />
100 1000 10000<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
S Series ITE (light blue) and HS/ITC,<br />
CIC (dark blue) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for the<br />
S Series HS/ITC at the highest matrix of 131/71.<br />
S Series ITE 71 – 2cc<br />
S Series CIC 71 – 2cc<br />
80<br />
OSPL90<br />
FOG 50<br />
140<br />
80<br />
OSPL90<br />
FOG 50<br />
140<br />
70<br />
130<br />
70<br />
130<br />
60<br />
120<br />
60<br />
120<br />
50<br />
110<br />
50<br />
110<br />
40<br />
100<br />
40<br />
100<br />
30<br />
100 1000 10000<br />
90<br />
30<br />
100 1000 10000<br />
90<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the S Series ITE at the highest matrix of 131/71.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the S Series CIC at the highest matrix of 131/71.<br />
Measurement Conditions and Recommendations<br />
The data for S Series are obtained and performance is expressed according to ANSI S3.22 (2003), IEC 60118-7<br />
(2005) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer as<br />
well as the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment.<br />
Data may be subject to change with product refinement.<br />
Because of the adaptive signal processing capabilities of S Series hearing instruments, the hearing instrument<br />
must be set to test mode to compare the actual performance of the hearing instrument with these specifications.<br />
S Series hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting<br />
the “<strong>Hearing</strong> Aid Test” screen from the menu on the left side of the Inspire window, then selecting the<br />
“Full On Gain” button.<br />
RF IMMUNITY LEVEL: These hearing instruments have a cell phone immunity rating of M4/T4. For your cell phone<br />
to be compatible with these hearing instruments, the cell phone needs an immunity rating of M1/T1 or higher.<br />
Please consult your cell phone specifications for your cell phone immunity rating.<br />
26
S Series Custom <strong>Hearing</strong> Instruments<br />
ANSI/IEC Data<br />
ITE HS/ITC CIC<br />
Measurement<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
Peak OSPL90 (dB SPL) 115-131 124-139 110-131 119-139 110-131 119-139<br />
HFA OSPL90 (dB SPL) 111-126 NA 106-126 NA 106-126 NA<br />
RTF OSPL90 (dB SPL) NA 118-138 NA 114-138 NA 114-138<br />
Peak Gain (dB) 45-71 54-79 40-71 50-79 35-71 50-79<br />
HFA Full-On Gain (dB) 41-65 NA 36-65 NA 31-65 NA<br />
RTF Full-On Gain (dB) NA 47-79 NA 43-78 NA 43-78<br />
Frequency Range (Hz) 100 - 7000 NA 100 - 7000 NA 100 - 7000 NA<br />
Reference Test Frequency (kHz) NA 1.6 NA 1.6 NA 1.6<br />
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA<br />
Reference Test Gain (dB) 34-49 40-64 29-49 36-63 29-49 36-63<br />
Harmonic Distortion<br />
500 Hz (%)
<strong>Hearing</strong> Instruments<br />
E Series Introduction 30<br />
E Series RIC 31<br />
E Series RIC Technical Specifications 32<br />
E Series RIC AP 34<br />
E Series RIC AP Technical Specifications 35<br />
E Series Custom <strong>Hearing</strong> Instruments 37<br />
E Series Custom <strong>Hearing</strong> Instruments Technical Specifications 38<br />
E Series<br />
<strong>Hearing</strong> Instruments
E Series<br />
E Series is Starkey’s latest line of economy<br />
hearing instruments, designed with Starkey’s<br />
high standards for quality and performance.<br />
E Series includes the most important features<br />
for providing a hearing experience that<br />
delivers quality sound and increased comfort.<br />
E Series 3 hearing instruments are 4 channel<br />
and 4 band devices. They include a feedback<br />
canceller, environmental adaptation and<br />
directional microphone.<br />
E Series<br />
<strong>Hearing</strong> Instruments<br />
30
FEATURES<br />
E Series 3 RIC<br />
RIC 40 110/40<br />
RIC 50 115/50<br />
Maximum Output<br />
Up to 30dB Reduction in 2dB Steps<br />
(range varies by channel)<br />
Compression Threshold<br />
24dB Range in 4dB Steps<br />
Compression Ratio<br />
1:1 – 3:1<br />
(range varies by channel)<br />
Power-on Delay<br />
Standard<br />
Color Guide<br />
Sterling<br />
Champagne<br />
Slate<br />
Pearl<br />
Bronze<br />
Onyx<br />
31
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
RIC<br />
Receiver-In-Canal<br />
E Series 3<br />
E Series RIC 40 Gain Receiver<br />
E Series RIC 40 – 2cc<br />
0<br />
60<br />
OSPL90<br />
FOG 50<br />
120<br />
10<br />
20<br />
30<br />
50<br />
110<br />
40<br />
50<br />
40<br />
100<br />
60<br />
70<br />
80<br />
30<br />
90<br />
90<br />
100<br />
110<br />
20<br />
80<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
70<br />
100 1000 10000<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
E Series 3 RIC 40 with open<br />
earbud (gray), occluded earbud<br />
(light blue), and custom occluded<br />
earmold (dark blue) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the E Series 3 RIC at 110/40.<br />
E Series RIC 50 Gain Receiver<br />
E Series RIC 50 – 2cc<br />
0<br />
60<br />
OSPL90<br />
FOG 50<br />
120<br />
10<br />
20<br />
30<br />
50<br />
110<br />
40<br />
50<br />
40<br />
100<br />
60<br />
70<br />
80<br />
30<br />
90<br />
90<br />
100<br />
20<br />
80<br />
110<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
70<br />
100 1000 10000<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
E Series 3 RIC 50 with open<br />
earbud (gray), occluded earbud<br />
(light blue), and custom occluded<br />
earmold (dark blue) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the E Series 3 RIC at 115/50.<br />
Measurement Conditions and Recommendations<br />
The data for E Series are obtained and performance is expressed according to ANSI S3.22 (2003), IEC 60118-7<br />
(2005) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer as<br />
well as the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment.<br />
Data may be subject to change with product refinement.<br />
Because of the adaptive signal processing capabilities of E Series hearing instruments, the hearing instrument<br />
must be set to test mode to compare the actual performance of the hearing instrument with these specifications.<br />
E Series hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting the<br />
“<strong>Hearing</strong> Aid Test” screen from the menu on the left side of the Inspire window, then selecting the<br />
“Full On Gain” button.<br />
RF IMMUNITY LEVEL: These hearing instruments have a cell phone immunity rating of M4. For your cell phone<br />
to be compatible with these hearing instruments, the cell phone needs an immunity rating of M1 or higher.<br />
Please consult your cell phone specifications for your cell phone immunity rating.<br />
32
E Series 3 RIC<br />
ANSI/IEC Data<br />
40 Gain Data 50 Gain Data<br />
Measurement<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
Peak OSPL90 (dB SPL) 110 122 115 126<br />
HFA OSPL90 (dB SPL) 102 NA 108 NA<br />
RTF OSPL90 (dB SPL) NA 110 NA 116<br />
Peak Gain (dB) 40 51 50 61<br />
HFA Full-On Gain (dB) 31 NA 44 NA<br />
RTF Full-On Gain (dB) NA 39 NA 51<br />
Frequency Range (Hz) 100 - 7900 NA 100 - 7300 NA<br />
Reference Test Frequency (kHz) NA 1.6 NA 1.6<br />
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA<br />
Reference Test Gain (dB) 26 32 31 41<br />
Harmonic Distortion<br />
500 Hz (%)
E Series 3 RIC AP<br />
FEATURES<br />
E Series 3 RIC AP<br />
RIC 60 123/60<br />
RIC 71 131/71<br />
Maximum Output<br />
Up to 30dB Reduction in 2dB Steps<br />
(range varies by channel)<br />
Compression Threshold<br />
24dB Range in 4dB Steps<br />
Compression Ratio<br />
1:1 – 3:1<br />
(range varies by channel)<br />
Power-on Delay<br />
Standard<br />
Color Guide<br />
Sterling<br />
Champagne<br />
Slate<br />
Pearl<br />
Bronze<br />
Onyx<br />
34
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
RIC AP<br />
Receiver-In-Canal<br />
E Series 3<br />
E Series RIC AP 60 Gain Receiver<br />
E Series 3 AP 60 – 2cc<br />
0<br />
70<br />
OSPL90<br />
FOG 50<br />
130<br />
10<br />
20<br />
60<br />
120<br />
30<br />
40<br />
50<br />
50<br />
110<br />
60<br />
70<br />
80<br />
90<br />
100<br />
110<br />
40<br />
30<br />
20<br />
100<br />
90<br />
80<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
100 1000 10000<br />
70<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
E Series 3 RIC AP 60 with<br />
custom occluded earmold<br />
(gray) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the E Series 3 RIC AP at 123/60.<br />
E Series RIC AP 71 Gain Receiver<br />
E Series 3 AP 71 – 2cc<br />
0<br />
OSPL90<br />
FOG 50<br />
10<br />
70<br />
130<br />
20<br />
30<br />
60<br />
120<br />
40<br />
50<br />
50<br />
110<br />
60<br />
70<br />
80<br />
90<br />
100<br />
110<br />
40<br />
30<br />
20<br />
100<br />
90<br />
80<br />
120<br />
250 500 1K 2K 4K 8K<br />
10<br />
100 1000 10000<br />
70<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
E Series 3 RIC AP 71 with<br />
custom occluded earmold<br />
(gray) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the E Series 3 RIC AP at 131/71.<br />
Measurement Conditions and Recommendations<br />
The data for E Series are obtained and performance is expressed according to ANSI S3.22 (2003), IEC 60118-7<br />
(2005) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer as<br />
well as the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment.<br />
Data may be subject to change with product refinement.<br />
Because of the adaptive signal processing capabilities of E Series hearing instruments, the hearing instrument<br />
must be set to test mode to compare the actual performance of the hearing instrument with these specifications.<br />
E Series hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting<br />
the “<strong>Hearing</strong> Aid Test” screen from the menu on the left side of the Inspire window, then selecting the<br />
“Full On Gain” button.<br />
RF IMMUNITY LEVEL: These hearing instruments have a cell phone immunity rating of M4. For your cell phone<br />
to be compatible with these hearing instruments, the cell phone needs an immunity rating of M1 or higher.<br />
Please consult your cell phone specifications for your cell phone immunity rating.<br />
35
E Series 3 RIC AP<br />
ANSI/IEC Data<br />
60 Gain Data 71 Gain Data<br />
Measurement<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
Peak OSPL90 (dB SPL) 123 130 131 139<br />
HFA OSPL90 (dB SPL) 115 NA 125 NA<br />
RTF OSPL90 (dB SPL) NA 127 NA 136<br />
Peak Gain (dB) 60 69 71 79<br />
HFA Full-On Gain (dB) 52 NA 64 NA<br />
RTF Full-On Gain (dB) NA 63 NA 75<br />
Frequency Range (Hz) 100 - 5400 NA 100 - 5300 NA<br />
Reference Test Frequency (kHz) NA 1.6 NA 1.6<br />
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA<br />
Reference Test Gain (dB) 39 52 48 61<br />
Harmonic Distortion<br />
500 Hz (%)
E Series 3 Custom <strong>Hearing</strong> Instruments<br />
FEATURES<br />
E Series 3 Custom <strong>Hearing</strong> Instruments<br />
ITE Up to 131/71<br />
ITC/HS Up to 131/71<br />
CIC Up to 131/71<br />
Maximum Output<br />
Up to 20dB Reduction in 2dB Steps<br />
(range varies by channel)<br />
Compression Threshold<br />
24dB Range in 4dB Steps<br />
Compression Ratio<br />
1:1 – 3:1<br />
(range varies by channel)<br />
Power-on Delay<br />
Standard<br />
Color Guide<br />
Faceplate Colors<br />
Pink<br />
Light Brown<br />
Medium Brown<br />
Chestnut<br />
Dark Brown<br />
Shell Colors<br />
Pink<br />
Light Brown<br />
Clear<br />
Blue/Red<br />
Dark Brown<br />
37
<strong>Hearing</strong> Level in dB (HL)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
FOG 50 (dB)<br />
FOG 50 (dB)<br />
OSPL90 (dBSPL)<br />
OSPL90 (dBSPL)<br />
ITE, HS, ITC, CIC<br />
In-The-Ear, Half-Shell,<br />
In-The-Canal, Completely-In-Canal<br />
E Series 3<br />
E Series Custom Products Fitting Ranges<br />
E Series ITC 71 – 2cc<br />
0<br />
80<br />
OSPL90<br />
FOG 50<br />
140<br />
10<br />
20<br />
30<br />
70<br />
130<br />
40<br />
50<br />
60<br />
120<br />
60<br />
70<br />
80<br />
50<br />
110<br />
90<br />
100<br />
110<br />
40<br />
100<br />
120<br />
250 500 1K 2K 4K 8K<br />
30<br />
90<br />
100 1000 10000<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
E Series 3 ITE (gray) and HS/ITC,<br />
CIC (light blue) fitting range.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for the<br />
E Series 3 HS/ITC at the highest matrix of 131/71.<br />
E Series ITE 71 – 2cc<br />
E Series CIC 71 – 2cc<br />
80<br />
OSPL90<br />
FOG 50<br />
140<br />
80<br />
OSPL90<br />
FOG 50<br />
140<br />
70<br />
130<br />
70<br />
130<br />
60<br />
120<br />
60<br />
120<br />
50<br />
110<br />
50<br />
110<br />
40<br />
100<br />
40<br />
100<br />
30<br />
100 1000 10000<br />
90<br />
30<br />
100 1000 10000<br />
90<br />
Frequency (Hz)<br />
Frequency (Hz)<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the E Series 3 ITE at the highest matrix of 131/71.<br />
OSPL90 (blue) and Full-On Gain (gray) curves for<br />
the E Series 3 CIC at the highest matrix of 131/71.<br />
Measurement Conditions and Recommendations<br />
The data for E Series are obtained and performance is expressed according to ANSI S3.22 (2003), IEC 60118-7<br />
(2005) and IEC 60118-0 (1983) with Amendment 1 (1994-01). The Starkey proprietary Real Time Analyzer as<br />
well as the Starkey Automated Design Verification Test System (SADVTS) comprise the basic test equipment.<br />
Data may be subject to change with product refinement.<br />
Because of the adaptive signal processing capabilities of E Series hearing instruments, the hearing instrument<br />
must be set to test mode to compare the actual performance of the hearing instrument with these specifications.<br />
E Series hearing instruments may be set to test mode with Inspire by reading the hearing aid and selecting<br />
the “<strong>Hearing</strong> Aid Test” screen from the menu on the left side of the Inspire window, then selecting the<br />
“Full On Gain” button.<br />
RF IMMUNITY LEVEL: These hearing instruments have a cell phone immunity rating of M4/T4. For your cell phone<br />
to be compatible with these hearing instruments, the cell phone needs an immunity rating of M1/T1 or higher.<br />
Please consult your cell phone specifications for your cell phone immunity rating.<br />
38
E Series 3 Custom <strong>Hearing</strong> Instruments<br />
ANSI/IEC Data<br />
ITE HS/ITC CIC<br />
Measurement<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
ANSI/IEC<br />
2cc Coupler<br />
IEC OES<br />
Coupler<br />
Peak OSPL90 (dB SPL) 115-131 124-139 110-131 119-139 110-131 119-139<br />
HFA OSPL90 (dB SPL) 111-126 NA 106-126 NA 106-126 NA<br />
RTF OSPL90 (dB SPL) NA 118-138 NA 114-138 NA 114-138<br />
Peak Gain (dB) 45-71 54-79 40-71 50-79 35-71 50-79<br />
HFA Full-On Gain (dB) 41-65 NA 36-65 NA 31-65 NA<br />
RTF Full-On Gain (dB) NA 47-79 NA 43-78 NA 43-78<br />
Frequency Range (Hz) 100 - 7000 NA 100 - 7000 NA 100 - 7000 NA<br />
Reference Test Frequency (kHz) NA 1.6 NA 1.6 NA 1.6<br />
HFA Frequencies (kHz) 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA 1.0, 1.6, 2.5 NA<br />
Reference Test Gain (dB) 34-49 40-64 29-49 36-63 29-49 36-63<br />
Harmonic Distortion<br />
500 Hz (%)
Earmold Selections<br />
Earmold Style Versus <strong>Hearing</strong> Loss 42<br />
Factors to Consider When Choosing Materials 42<br />
Custom Earmold Colors 42<br />
Available Materials 43<br />
Custom Earmold Materials 44<br />
Custom Earmold Styles 45<br />
Earmold Selections
Earmold Selection<br />
Earmold Style Versus <strong>Hearing</strong> Loss<br />
When selecting the style of earmold, consider the type of hearing instrument<br />
prescribed. Please note that high gain instruments require a tighter seal than mild<br />
gain instruments. Shell and Skeleton molds generally provide the best acoustic seal.<br />
Severity of <strong>Hearing</strong> Loss<br />
Earmold Style Mild Moderate Severe-Profound<br />
Receiver • •<br />
Shell • • •<br />
Half Shell • •<br />
Canal • •<br />
Canal Lock • •<br />
Skeleton • • •<br />
Semi-Skeleton • •<br />
Non-Occluding • •<br />
Factors to Consider When Choosing Materials<br />
Texture of the ear: A soft ear will make insertion of an earmold more difficult. In this<br />
case, a rigid mold would be a better choice.<br />
Possible allergies to material: There are a variety of materials that are less likely to<br />
cause an allergic reaction. These non-allergenic materials can be either rigid or soft.<br />
Power of hearing instrument: A high power hearing instrument will have more of a<br />
tendency to feed back than a mild gain instrument. A softer material will tend to seal<br />
better than a rigid material. There are several materials available offering a range<br />
of softness.<br />
Earmold Selections<br />
Custom Earmold Colors<br />
Please note that color availability and appearance will vary according to material and<br />
specific style. Camouflage and glitter–based colors are also available. Please consult<br />
the order form or your sales representative for specific ordering instructions. Custom<br />
colors can also be created using a mixing process. Contact your sales representative<br />
for additional information.<br />
42
Available Materials<br />
Most Rigid<br />
Lucite<br />
Lucite is a clear, rigid acrylic<br />
material. It is the most<br />
commonly used earmold<br />
material. It is cosmetically<br />
appealing and available<br />
in all styles and various<br />
colors. Lucite is easily<br />
modified by the hearing<br />
care professional.<br />
Digital SLS<br />
Earmolds made by scanning<br />
and modeling in a virtual<br />
setting of stereolithography<br />
are known as Digital SLS.<br />
Digital SLS is a process<br />
technology that optimizes<br />
earmold fit for comfort and<br />
performance. It is available<br />
in a Lucite, clear form on the<br />
following selected styles:<br />
direct tube, shell, ¾ shell,<br />
half shell, canal, canal lock,<br />
and non-occluding type G.<br />
Lucite with Flex Canal<br />
The Flex Canal mold<br />
combines the cosmetic<br />
and convenient properties<br />
of Lucite with the comfort<br />
and sealing properties of<br />
Starflex. It is recommended<br />
for fitting moderate to<br />
severe hearing losses. It is<br />
available in all styles except<br />
non-occluding. Flex Canals<br />
are not compatible with<br />
acoustic modifiers.<br />
Polyethylene<br />
Polyethylene is a smooth,<br />
waxy, non-allergenic material<br />
which is fairly rigid. White<br />
is the only color available.<br />
Modification of polyethylene<br />
is not recommended. This<br />
material is recommended<br />
only for cases where<br />
an allergy problem has<br />
been determined. Also, it is<br />
recommended that an<br />
elbow attachment be used<br />
for polyethylene molds.<br />
Starflex<br />
Starflex is a translucent,<br />
flexible plastic. It conforms<br />
to the shape of the ear and<br />
becomes softer at body<br />
temperature. It provides<br />
a good acoustic seal for<br />
high gain instruments.<br />
Modification of Starflex is<br />
more difficult than Lucite<br />
and this material may harden<br />
after several months of use.<br />
Ultraflex<br />
Ultraflex is a very soft, yet<br />
durable vinyl material.<br />
It gives a good acoustic<br />
seal for high gain<br />
hearing instruments. It is<br />
recommended for fitting<br />
severe losses, pediatric<br />
molds or for patients who<br />
cannot tolerate hard<br />
materials.<br />
Modification is not<br />
recommended.<br />
Silicone<br />
Silicone (medical grade)<br />
shares the softness<br />
and durability qualities<br />
of Ultraflex, but is<br />
non-allergenic. It is<br />
recommended when a<br />
soft material is needed<br />
and an allergy problem<br />
has been determined. As<br />
with Ultraflex, modification<br />
is not recommended. A<br />
Vinyl Anchor is also a<br />
suggested option.<br />
Floatable swim plugs are<br />
available for children and<br />
adults of all ages. There are<br />
11 colors available. Floatable<br />
swim plugs are not available<br />
in Clear.<br />
Heat cured (non-floatable)<br />
silicone is available for<br />
earplugs and earmolds.<br />
These are very comfortable<br />
to wear, especially for ear<br />
protection in industrial areas,<br />
at home or at play. Pediatric<br />
earmolds are made from<br />
this material because it<br />
is soft. It is available in<br />
11 vibrant colors.<br />
Biopore silicone works<br />
well for canal and half<br />
shell fittings and is very<br />
comfortable for both<br />
earmolds and earplugs.<br />
Available colors include<br />
Clear, Flesh, Red and Blue.<br />
ProSeal<br />
Softest<br />
ProSeal is the softest<br />
earmold material available,<br />
but because of its extreme<br />
softness, ProSeal molds can<br />
be difficult to insert. This<br />
durable material provides<br />
an excellent seal and is<br />
recommended for fitting<br />
severe hearing losses. As<br />
with other soft materials,<br />
modifications are not<br />
recommended. A Vinyl<br />
Anchor is recommended<br />
to help retain the tubing.<br />
ProSeal molds are available<br />
in translucent Flesh, Clear<br />
and Brown colors.<br />
43
Custom Earmold Materials<br />
Material<br />
Options Lucite<br />
Lucite<br />
w/Flex<br />
Canal<br />
Starflex<br />
Ultraflex<br />
(Vinyl)<br />
Silicone<br />
Floatable<br />
Silicone<br />
Non-<br />
Floatable<br />
Silicone<br />
Biopore<br />
Silicone<br />
ProSeal<br />
Silicone<br />
Polyethylene<br />
Push Pull Elbow • • • • • • • • • •<br />
Starquick • • • • • • • • • •<br />
Plastic Tube Lock<br />
(13H only)<br />
• • • • • • •<br />
Gold Tube Lock (13H) • • • • •<br />
Barb Lock • • • • •<br />
Dry Tubes • • • • • • • • • •<br />
R & L Handles • • • • • • • • •<br />
Slot Handle • • • •<br />
Nubbin Handle • • • • • • • • •<br />
String Handle • • • • • • • • •<br />
Initials • • • • •<br />
CFA Adaptor • • • •<br />
Several earmold styles are shown on the following pages. For more detailed<br />
information and a complete selection of earmolds, refer to the ListenHear<br />
Conservation, Enhancement and Earmold <strong>Solutions</strong> <strong>Catalog</strong> (83553-007).<br />
44
Custom Earmold Styles<br />
NO<br />
RIC Earmold<br />
RIC Open Earmolds are a hollow<br />
canal style shell in hard acrylic created<br />
with stereolithography scanning.<br />
These earmolds fit all Starkey RIC<br />
hearing instruments. Additional RIC<br />
earmold options include: canal locks,<br />
occluded earmolds, and soft material.<br />
Shown in Clear Lucite.<br />
RECEIVER<br />
CANAL<br />
NON-O<br />
JANSSEN<br />
Open Fit EF Mold<br />
Open Fit EF Molds are a hollow<br />
canal shell style in hard acrylic that<br />
supports thin tube fittings done with<br />
stereolithography scanning. Tubing<br />
fits standard hearing instruments.<br />
Some other custom tube holders<br />
may be used depending on size. A<br />
Canal Lock version is also available<br />
for added retention. Select-a-vent<br />
option also available. Shown in<br />
Clear Lucite.<br />
Shell Mold<br />
CANAL LOCK<br />
HALF SHELL<br />
ASPECT EF<br />
ARISTA-LITE MOLD<br />
DIRECT TUBE<br />
The Shell Mold (sculpted) is<br />
exceptionally sturdy and lightweight<br />
and is recommended for fitting<br />
moderate and severe hearing<br />
losses. It provides an effective seal<br />
to reduce the likelihood of feedback<br />
and occlusion. Shown in Blue Lucite.<br />
CIC<br />
EARPLUGS<br />
SHELL<br />
3/4 Shell Mold<br />
SKELETON<br />
This earmold has the helix tip cut<br />
back for ease of insertion and is<br />
available in the same materials as<br />
the Shell Mold. Shown in Red Lucite.<br />
HOCKS NOISE BRAKER<br />
3/4 SHELL<br />
SEMI-SKELETON<br />
CORDED EAR PLUG<br />
45<br />
NON-OCCLUDING
CANAL<br />
Custom Earmold Styles, cont’d<br />
Half Shell Mold<br />
The Half Shell Mold offers a<br />
comfortable and lightweight fit. Its<br />
size provides easy insertion and<br />
removal. Because of its smaller size<br />
and lack of a helix area, the Half<br />
Shell is not recommended for fitting<br />
severe hearing losses. Shown in<br />
Brown Lucite.<br />
CANAL LOCK<br />
HALF SHELL<br />
RECEIVER<br />
Canal Mold<br />
The Canal Mold is the second<br />
smallest mold available and offers<br />
superior comfort and cosmetic<br />
appeal. Canal earmolds require a<br />
long ear canal for good retention.<br />
Because of its size, the Canal Mold<br />
is not recommended for fitting<br />
severe hearing losses. Shown in<br />
Clear Lucite.<br />
Canal Lock Mold<br />
The Canal Lock Mold is similar to the<br />
Canal Mold with an added protrusion in<br />
the concha. It is designed to be small<br />
and inconspicuous like a Canal Mold,<br />
but with better retention. The Canal<br />
Lock is also not recommended for<br />
fitting severe hearing losses. Shown in<br />
Brown Lucite.<br />
Skeleton Mold<br />
The Skeleton Mold is the most<br />
popular earmold available because<br />
it provides maximum comfort and<br />
retention. It is appropriate for fitting<br />
mild to severe hearing losses and<br />
can be easily modified to other<br />
styles. Shown in Red Lucite.<br />
DIRECT TUBE<br />
RECEIVER<br />
CANAL<br />
SHELL<br />
CANAL<br />
CANAL LOCK<br />
RECEIVER<br />
SKELETON<br />
CANAL LOCK<br />
HALF CANAL SHELL<br />
SEMI-SKELETON<br />
HALF<br />
CANAL<br />
SHELL<br />
LOCK<br />
DIRECT TUBE<br />
DIRECT TUBE<br />
NON-OCCLUDING<br />
SHELL HALF SHELL A<br />
SHELL<br />
NON-OCCLUDING DIRECT TUBE B<br />
SKELETON<br />
46<br />
SKELETON<br />
SEMI-SKELETON<br />
SHELL<br />
JANSSEN
SHELL<br />
HALF JANSSEN SHELL<br />
Custom Earmold Styles, cont’d<br />
Semi-Skeleton Mold<br />
The Semi-Skeleton Mold is<br />
inconspicuous and lightweight and<br />
provides good retention for most ears.<br />
It is recommended for ears with distorted<br />
or flat concha areas or for those with<br />
limited dexterity who require easier<br />
insertion. Shown in Orange Lucite.<br />
CIC Mold<br />
CIC (completely-in-canal) Earmolds are<br />
hidden in the ear canal and provide<br />
for discreet fittings. This is the smallest<br />
earmold available. Available in all<br />
materials. Shown in Clear Lucite.<br />
HALF SHELL<br />
SKELETON<br />
DIRECT TUBE<br />
ARISTA-LITE MOLD<br />
DIRECT TUBE<br />
SEMI-SKELETON<br />
SHELL<br />
SHELL<br />
ASPECT EF<br />
SKELETON<br />
NON-OCCLUDING A<br />
SKELETON<br />
CIC<br />
Non-Occluding A Mold<br />
Non-Occluding A Molds provide a<br />
retention ring for the tube without<br />
occluding the ear. Style A differs from B<br />
in that the canal portion is finished with<br />
material the length of the tube. Non-<br />
Occluding A Molds are recommended<br />
for patients with normal hearing to<br />
1500 Hz, or for patients who use<br />
tinnitus maskers or CROS instruments.<br />
Shown in Flesh Lucite.<br />
SEMI-SKELETON<br />
NON-OCCLUDING B<br />
SEMI-SKELETON<br />
EARPLUGS<br />
NON-OCCLUDING<br />
JANSSEN<br />
A<br />
NON-OCCLUDING HOCKS NOISE BRAKA<br />
Non-Occluding B Mold<br />
Non-Occluding B Molds provide a<br />
retention ring for the tube without<br />
occluding the ear. Non-Occluding B<br />
Molds are recommended for patients<br />
with normal hearing to 1500 Hz, or for<br />
patients who use tinnitus maskers or<br />
cross instruments. Shown in Red Lucite.<br />
Receiver Mold<br />
The Receiver Mold is used with an<br />
external receiver that is snapped into<br />
the mold. Appropriate applications<br />
include: body aids, stethoscopes,<br />
anesthesiologists scopes and other<br />
listening devices. Shown in Blue Lucite.<br />
NON-OCCLUDING ARISTA-LITE MOLDB<br />
NON-OCCLUDING B<br />
CORDED EAR PLUG<br />
JANSSEN<br />
ASPECT EF<br />
JANSSEN<br />
NON-OCCLUDING J<br />
RECEIVER<br />
ARISTA-LITE MOLD<br />
CIC<br />
ARISTA-LITE MOLD<br />
CANAL 47
Venting Guide<br />
Venting Options 50<br />
Venting Guide
Venting Guide<br />
Venting Options<br />
Vents are typically parallel depending on room availability.<br />
Pressure vent. ........................................ 0.08 mm<br />
Small vent.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 mm<br />
Medium vent.......................................... 1.6 mm<br />
Large vent............................................ 2.3 mm<br />
X-Large vent.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0 mm<br />
Select–a–vent .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.37 mm<br />
IROS venting is stepped back at the canal tip and opened to 3 mm all the<br />
way through.<br />
Trench venting is external venting. Size varies.<br />
Select-a-vents provide five different sizes to choose from. The outside dimension is<br />
.144 mm. Inside dimensions are .096 mm, .078 mm, .067 mm, .058 mm and .041 mm.<br />
Select-a-Vent (VV)<br />
~4 mm diameter vent (ITE) or ~3 mm diameter vent<br />
(HS/ITC), supplied with a tree of variable sized vent plugs.<br />
This is the most flexible and most preferred venting option<br />
for ITEs with up to 45dB of gain.<br />
Mini Vent (MV)<br />
~2 mm diameter vent, supplied with a tree of variable sized<br />
vent plugs. Standard on Half Shell and ITC instruments with<br />
up to 40dB of gain.<br />
DV Vent (DV)<br />
Variable vent with a tapered tip 1/4 inch, supplied with<br />
a tree of variable sized vent plugs.<br />
2 Vent (2V)<br />
~2 mm diameter vent, standard on CICs with up to<br />
40dB of gain. No vent plugs.<br />
Venting Guide<br />
50
1 Vent/Pressure Vent (1V)<br />
~1 mm diameter vent. No vent plugs.<br />
IROS B (IB) Vent<br />
Standard IROS Vent in ITEs. Tapered from the faceplate<br />
1/4 inch. Open 4 mm or larger as shell size permits.<br />
IROS C (IC)<br />
Standard IROS for ITCs. Also available on ITEs.<br />
Tapered from both ends 1/4 inch. Open as large<br />
as shell size permits.<br />
IROS CIC (IT)<br />
IROS for Tympanettes (CICs). Canal tip is tapered 1/8 - 1/4<br />
inch dependent on canal length. The faceplate is opened<br />
up as much as shell size permits.<br />
BILL AUSTIN VENT (BAV)<br />
IROS vent located on bottom of CIC shell. Available on<br />
CICs up to 40dB. Availability dependent on size of canal.<br />
IROS OPEN (IO)<br />
Largest IROS vent available on 30dB CICs, clear shell only.<br />
Availability dependent on size of canal.<br />
VSN (I2)<br />
Largest dual IROS vent available on 35dB CICs, clear shell<br />
only. Availability dependent on size of canal.<br />
51
A global hearing technology<br />
company headquartered in<br />
Eden Prairie, Minnesota, U.S.A.<br />
Starkey Laboratories, Inc.<br />
6700 Washington Avenue South<br />
Eden Prairie, MN 55344-3476<br />
800.328.8602<br />
StarkeyPro.com<br />
© 2009 Starkey Laboratories, Inc. All Rights Reserved.<br />
84061-000 3/09 BKLT0111-00-EE-ST