27.09.2015 Views

Kapitex…Adding Quality of Life to Airway Management

Specialist Laryngology - Kapitex Healthcare

Specialist Laryngology - Kapitex Healthcare

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

K a p i t e x h e a l t h c a r e - S p e c i a l i S t K n o w l e d g e , S u p p o r t a n d c a r e<br />

SpecialiSt airwaY<br />

<strong>Kapitex…Adding</strong> <strong>Quality</strong> <strong>of</strong> <strong>Life</strong><br />

<strong>to</strong> <strong>Airway</strong> <strong>Management</strong>


Kapitex have a comprehensive care package <strong>of</strong> products which have been<br />

specifically designed and produced <strong>to</strong> help manage all aspects <strong>of</strong> Specialist<br />

<strong>Airway</strong> <strong>Management</strong>.<br />

Our range <strong>of</strong> specialist airway products covered in this brochure include:<br />

Montgomery®<br />

Laryngeal Stent 3<br />

Montgomery®<br />

Laryngeal Keel 4<br />

Montgomery®<br />

Salivary Bypass Tube 5<br />

Montgomery®<br />

Har-El Pharyngeal Tube 6<br />

Montgomery®<br />

Esophageal Tube 7<br />

Montgomery® Thyroplasty<br />

Implant System 8<br />

2


3<br />

MontgomeryLaryngeal Stent<br />

Montgomery®<br />

Laryngeal Stent<br />

Description<br />

TheMontgomery®LaryngealStentisamouldedsilicone<br />

prosthesisdesigned<strong>to</strong>conform<strong>to</strong>thenormalendolaryngeal<br />

surface.Thestentisconstructed<strong>of</strong>radio-opaqueimplant<br />

gradesiliconethatisfirmenough<strong>to</strong>supporttheendolarynx<br />

pos<strong>to</strong>peratively,yetiss<strong>of</strong>tandflexibleenough<strong>to</strong>ensurea<br />

conformingfitwhileminimisinginjury<strong>to</strong>s<strong>of</strong>ttissues.<br />

Thestentmaybeutilisedasadirectsupportforintralaryngeal<br />

mucosalordermalgraphs<strong>to</strong>denudedareas<strong>of</strong>the<br />

endolarynx.EachMontgomery®LaryngealStentincludestwo<br />

siliconesuturebut<strong>to</strong>ns<strong>to</strong>supportthestentexternally.<br />

Indications for use<br />

Forthepreventionandtreatment<strong>of</strong>laryngealstenosiswhen<br />

theglotticstenosisinvolvesthemidglottis,posteriorglottis,<br />

supraglottis,andsubglottis,singularlyorincombination.<br />

Supplied<br />

• Sterile<br />

• 1stent,2suturebut<strong>to</strong>ns<br />

Dimensions, Product Codes & Accessories<br />

Order Description Dimensions<br />

Number<br />

(mm)<br />

A B C<br />

OSLST0001 Child 33 10 9<br />

OSLST0003 SmallAdult 37 10 11<br />

OSLST0004 MediumAdult 40 12 10<br />

OSLST0005 LargeAdult 47 15 16<br />

OSLST0002 StentBut<strong>to</strong>ns(pair)<br />

FEATURES<br />

• Implantgradesilicone<br />

• Non-adherentsmoothsurface<br />

• Integralremovalloop<br />

• Radio-opaquematerial<br />

For further details, please contact Kapitex Cus<strong>to</strong>mer Services on 01937 580211


MontgomeryLaryngeal Keel<br />

Montgomery®<br />

Laryngeal Keel<br />

Description<br />

TheMontgomery®LaryngealStentisamouldedsilicone<br />

prosthesisdesigned<strong>to</strong>conform<strong>to</strong>thenormalendolaryngeal<br />

surface.Thestentisconstructed<strong>of</strong>radio-opaqueimplant<br />

gradesiliconethatisfirmenough<strong>to</strong>supporttheendolarynx<br />

pos<strong>to</strong>peratively,yetiss<strong>of</strong>tandflexibleenough<strong>to</strong>ensurea<br />

conformingfitwhileminimisinginjury<strong>to</strong>s<strong>of</strong>ttissues.<br />

Thestentmaybeutilisedasadirectsupportforintralaryngeal<br />

mucosalordermalgrafts<strong>to</strong>denudedareas<strong>of</strong>theendolarynx.<br />

EachMontgomery®LaryngealStentincludestwosilicone<br />

suturebut<strong>to</strong>ns<strong>to</strong>supportthestentexternally.<br />

Indications for use<br />

Forthepreventionandtreatment<strong>of</strong>laryngealstenosiswhen<br />

theglotticstenosisinvolvesthemidglottis,posteriorglottis,<br />

supraglottis,andsubglottis,singularlyorincombination.<br />

Supplied<br />

• Sterile<br />

• 1stent,2suturebut<strong>to</strong>ns<br />

FEATURES<br />

• Implantgradesilicone<br />

• Non-adherentsmoothsurface<br />

• Availableinclearorradio-opaquematerial<br />

Dimensions, Product Codes & Accessories<br />

SIZE REF Dimensions<br />

(mm)<br />

clear radio-opaque A<br />

12 OSLST0006 OSLST0009 12<br />

14 OSLST0007 OSLST0010 14<br />

16 OSLST0008 OSLST0011 16<br />

For further details, please contact Kapitex Cus<strong>to</strong>mer Services on 01937 580211<br />

4


5<br />

MontgomerySalivary Bypass Tube<br />

Montgomery®<br />

Salivary Bypass Tube<br />

Description<br />

TheMontgomery®SalivaryBypassTubemaybeused<strong>to</strong>stent<br />

repair<strong>of</strong>cervicalesophagealandhypopharyngealstrictures<br />

ort<strong>of</strong>acilitatethemanagement<strong>of</strong>fistulaeresultingfroma<br />

variety<strong>of</strong>causesincludingadvancedmalignancy,surgery,<br />

radiation,trauma,andcausticingestion.Theconstantbathing<br />

bysaliva<strong>to</strong>thetissuesalteredbysurgery,infection,or<br />

radiationtherapyisaprimefac<strong>to</strong>rinretardingtheprogress<strong>of</strong><br />

healingandfistulaclosure.<br />

TheMontgomery®SalivaryBypassTubedirectsthesalivain<strong>to</strong><br />

thedistalesophagusandallowsforspontaneousclosure<strong>of</strong><br />

thefistula,oratleastpermitsthetissue<strong>to</strong>recoversufficiently<br />

<strong>to</strong>beanimprovedrecipientformoreformidablemeasures<br />

suchasrepairusingpedicledskinflaptissue.Afeedingtube<br />

maybeinsertedthroughthesalivarybypasstube.Impending<br />

fistulaeandstricturesmaybepreventedbytubeplacement<br />

aloneorfollowingbougienagedilation.<br />

Indications for use<br />

Repair<strong>of</strong>cervicalesophagealandhypopharyngealstrictures.<br />

<strong>Management</strong><strong>of</strong>esophagealandhypopharyngealfistulae.<br />

Supplied<br />

• Sterile<br />

• 1tube<br />

Dimensions, Product Codes & Accessories<br />

Order Size Dimensions<br />

Number<br />

(mm)<br />

A B C<br />

OSMST0002 08 34 191 8<br />

OSMST0003 10 36 191 10<br />

OSMST0004 12 38 191 12<br />

OSMST0005 14 40 191 14<br />

OSMST0006 16 42 191 16<br />

SpecialOrder 18 44 191 18<br />

SpecialOrder 20 46 191 20<br />

Alsoavailableinradio-opaque-pleasecontactKapitexfor<br />

moreinformation.<br />

FEATURES<br />

• Implantgradesilicone<br />

• Non-adherentsmoothsurface<br />

• Availableinclearorradio-opaquematerial


MontgomeryHar-El Pharyngeal Tube<br />

Montgomery®<br />

Har-El Pharyngeal Tube<br />

Description<br />

TheHar-ElPharyngealSalivaryBypassTubeallowsthe<br />

surgeon<strong>to</strong>handleawidervariety<strong>of</strong>indicationsfortreatment<br />

<strong>of</strong>esophagealfistulae.Thetubefeaturesauniquesuperior<br />

funnelshapedesignedforanchoringatthelevel<strong>of</strong>the<br />

<strong>to</strong>nguebase.<br />

Thetubehasapplicationsfor:1)thetreatment<strong>of</strong><br />

orocutaneousandpharyngocutaneousfistulaefollowing<br />

headandneckoncologicresection,2)placementinpatients<br />

withanexistingfistulaprior<strong>to</strong>reconstructiveprocedures,and<br />

3)prophylacticplacementinpatientswhoareathighriskfor<br />

development<strong>of</strong>afistula.<br />

Indications for use<br />

Treatment<strong>of</strong>esophagealfistulae.<br />

Supplied<br />

• Sterile<br />

• 1tube<br />

FEATURES<br />

• Implantgradesilicone<br />

• Non-adherentsmoothsurface<br />

• Availableinclearorradio-opaquematerial<br />

Dimensions, Product Codes & Accessories<br />

OrderNumbers<br />

SIZE clear radio-opaque<br />

12 OSMPT0001 OSMPT0002<br />

For further details, please contact Kapitex Cus<strong>to</strong>mer Services on 01937 580211<br />

6


Montgomery®<br />

Esophageal Tube<br />

Description<br />

TheMontgomery®EsophagealTubeisused<strong>to</strong>bridgethegap<br />

betweenthepharyngos<strong>to</strong>meandesophagos<strong>to</strong>mefollowing<br />

laryngoesophagec<strong>to</strong>myandfirststagereconstruction<strong>of</strong>the<br />

cervicalesophagus.Thetubefeaturesafunnel-shaped<br />

superiorend<strong>to</strong>conform<strong>to</strong>thehypopharynx,andtw<strong>of</strong>irm<br />

ovalbandsdesigned<strong>to</strong>ensureproperpositioningand<strong>to</strong><br />

preventleakage<strong>of</strong>salivaafterlaryngoesophagec<strong>to</strong>my.<br />

MontgomeryEsophageal Tube<br />

TheMontgomery®EsophagealTubehasthreefunctions:<br />

1)ittends<strong>to</strong>eliminatetheproblem<strong>of</strong>pr<strong>of</strong>usesalivaryleakage<br />

byway<strong>of</strong>thepharyngos<strong>to</strong>me,2)itmaintainsawidelypatent<br />

pharyngos<strong>to</strong>meandesophagos<strong>to</strong>me,and3)itcreatesa<br />

troughbetweenthepharyngos<strong>to</strong>meandesophagos<strong>to</strong>me<br />

facilitatingthesecondstageprocedure.<br />

Indications for use<br />

Fortwo-stagereconstruction<strong>of</strong>thecervicalesophagus.<br />

FEATURES<br />

• Implantgradesilicone<br />

• Non-adherentsmoothsurface<br />

• Availableinclearorradio-opaquematerial<br />

Supplied<br />

• Sterile<br />

• 1tube<br />

Dimensions, Product Codes & Accessories<br />

REF<br />

clear<br />

OSMET0001<br />

radio-opaque<br />

OSMET0002<br />

For further details, please contact Kapitex Cus<strong>to</strong>mer Services on 01937 580211<br />

57


MontgomeryThyroplasty Implant System<br />

Montgomery®<br />

Thyroplasty Implant System<br />

The Montgomery® Thyroplasty Implant System is the<br />

result <strong>of</strong> over a decade <strong>of</strong> research and development.<br />

Description<br />

Designed<strong>to</strong>treatunilateralvocalcordparalysis,this<br />

revolutionarynewsystemisstandardised,eliminatingthe<br />

time-consumingprocess<strong>of</strong>cus<strong>to</strong>misingimplantsatthetime<br />

<strong>of</strong>surgery.Standardisationtranslates<strong>to</strong>consistentresults.<br />

Solidclinicalexperienceinvolvingthousands<strong>of</strong>patientshas<br />

producedoutstandingvoiceimprovementwhilereducing<br />

longproceduresandcomplicationsassociatedwithhandcarvedimplantsandinjectiontechniques.<br />

Indications for use<br />

Formedialisationthyroplastyinpatientswithunilateralvocal<br />

cordparalysis<strong>to</strong>improvevoicequality.<br />

FEATURES<br />

• Completestandardisedsystem<br />

• Eliminatesneed<strong>to</strong>hand-fashionimplants<br />

• Self-retainingimplantdesign<br />

• Nosuturingisnecessary<br />

• Reducedtraumaandsurgerytime<br />

• Reversible<br />

• Provenclinicalsuccess<br />

For further details, please contact Kapitex Cus<strong>to</strong>mer Services on 01937 580211<br />

8


9<br />

MontgomeryThyroplasty Implant System<br />

The Design<br />

Thesystemconsists<strong>of</strong>speciallydesignedsurgical<br />

instruments,devicesformeasuringmedialisationdistance<br />

prior<strong>to</strong>implantinsertion,andarange<strong>of</strong>fiveimplantsizesfor<br />

femalepatientsandfivesizesformales.Theimplantsare<br />

constructedusingimplantgradesiliconewhichhas<br />

undergoneextensivebiocompatibilitytesting.<br />

Thesurgicalprocedurehasbeenfine-tunedandinvolvesa<br />

step-by-stepprocessforlocatingthethyroplastywindow,<br />

creatingthewindow,determiningimplantsize,andinserting<br />

theimplant.Theprocedurereducessurgerytimeandis<br />

completelyreversible.A procedural CD demonstrating the<br />

surgical procedure is available.<br />

Theuniquedesign<strong>of</strong>theMontgomery®ThyroplastyImplant<br />

consists<strong>of</strong>twomajorcomponents:therectangularbaseand<br />

thetriangular<strong>to</strong>p.Thebaseisconstructed<strong>of</strong>firmsiliconeand<br />

featuresthreetiers.Thelateral,oroutertier,remainsonthe<br />

outersurface<strong>of</strong>thethyroidlaminaandpreventsmedial<br />

displacement<strong>of</strong>theimplant.Themiddletierstabilisesthe<br />

implantandpreventsrotation.Theinnertierrestsagainstthe<br />

innersurface<strong>of</strong>thethyroidlaminaandpreventsoutward<br />

displacement.Thereisacommonbaseforfemalesanda<br />

commonbaseformales.<br />

Thetriangularportionismadeusings<strong>of</strong>tsiliconeandserves<br />

<strong>to</strong>medialisethevocalcordandthevocalprocess<strong>of</strong>the<br />

arytenoid.Thehypotenuse<strong>of</strong>thetrianglecorresponds<strong>to</strong>the<br />

longaxis<strong>of</strong>thevocalcord.Theheight<strong>of</strong>thetriangleis<br />

measuredinmillimetersandisavailablein6,7,8,9and10mm<br />

forfemalesand8,9,10,11and12mmformales.<br />

Specialmeasuringdeviceshavebeendesigned<strong>to</strong>accurately<br />

simulatevocalcordmedialisationeliminatingtheneed<strong>to</strong><br />

insertandreplacemultipleimplants.Thisresultsinlesstrauma<br />

<strong>to</strong>thepatientandreducedsurgerytime.Thedisposableset<br />

includesallfivesizes<strong>to</strong>correspond<strong>to</strong>theimplantsandis<br />

availableinbothfemaleandmalekits.<br />

Cus<strong>to</strong>msurgicalinstrumentst<strong>of</strong>acilitatelocating,designing,<br />

andcreatingthewindowandinsertingtheimplantare<br />

availableindividually,orasacomplete13-piecesetwith<br />

sterilisationtray.<br />

ASingleProcedureKitisnowavailableandincludes<br />

everythingyouneed<strong>to</strong>performonethyroplastyprocedure.<br />

Wewillsendyouacompleteinstrumentset,measuringkit,<br />

andfiveimplants.Afterperformingthecase,simplysendback<br />

theinstrumentsandunusedimplantsintheconvenient<br />

suppliedcontainer.Bos<strong>to</strong>nMedicalProductsnowmakesit<br />

eveneasier<strong>to</strong>usetheMontgomeryThyroplastyImplant<br />

System!<br />

For further details, please contact Kapitex Cus<strong>to</strong>mer Services on 01937 580211


MontgomeryThyroplasty Implant System<br />

The Procedure<br />

TheMontgomery®ThyroplastyImplant<br />

Systemprocedurehasbeenstandardised<br />

andrefinedthroughyears<strong>of</strong>researchand<br />

development.Thefollowingillustrations<br />

summarisethebasicstepsinperforming<br />

theprocedure.Fordetailedinstructions,<br />

refer<strong>to</strong>theMontgomery®Thyroplasty<br />

ImplantSystemSurgeon’sImplantGuide.<br />

a. Prep and Drape b. Expose Thyroid Cartilage<br />

c. Locate key point after having defined a<br />

connecting line<br />

d. Apply Outline Instrument on the key point e. Window Outline<br />

f. Create Window g. Remove Cartilage h. Confirm Window Size<br />

10<br />

i. Apply Measuring Devices j. Insert Implant with implant inserter k. Implant in Place


System Options<br />

Option 1 - Individual System Components<br />

Montgomery®ThyroplastyImplants,suppliedsterile,oneimplantper<br />

car<strong>to</strong>n.<br />

OrderNo.<br />

OSMTF0001<br />

OSMTF0002<br />

OSMTF0003<br />

OSMTF0004<br />

OSMTF0005<br />

OSMTF0006<br />

Montgomery®ThyroplastyMeasuringDeviceKits<br />

Suppliedsterile,disposable.Kitsincludeone<strong>of</strong>eachsizemeasuring<br />

device(5sizesperkit).<br />

OrderNo.<br />

OSMTK0001<br />

OSMTK0002<br />

FemaleSize6<br />

FemaleSize7<br />

FemaleSize8<br />

FemaleSize9<br />

FemaleSize10<br />

FemaleSize11<br />

OrderNo.<br />

OSMTM0001<br />

OSMTM0002<br />

OSMTM0003<br />

OSMTM0004<br />

OSMTM0005<br />

OSMTM0006<br />

FemaleMeasuringDeviceKit<br />

MaleMeasuringDeviceKit<br />

MaleSize8<br />

MaleSize9<br />

MaleSize10<br />

MaleSize11<br />

MaleSize12<br />

MaleSize13<br />

16-ImplantDispenserSets,contains16implants.<br />

Significantsavingsoverpurchasingindividualimplants.<br />

REF<br />

MTC-01<br />

MTF-01<br />

MTM-01<br />

OrderNo.<br />

OSMTT0001<br />

MaleandFemaleCombination<br />

ImplantSet,contains16implants:<br />

1ea.femalesizes6,7/2ea.femalesizes8,9,10<br />

1ea.malesizes8,9/2ea.malesizes10,11,12<br />

FemaleImplantSet,contains16implants:<br />

2ea.femalesizes6,7/4ea.femalesizes8,9,10<br />

MaleImplantSet,contains16implants:<br />

2ea.malesizes8,9/4ea.malesizes10,11,12<br />

13-pieceSurgicalInstrumentsSetwith<br />

Cus<strong>to</strong>mSterilisationTray<br />

MontgomeryThyroplasty Implant System<br />

Montgomery®ThyroplastySurgicalInstruments,suppliednonsterile.<br />

OrderNo.<br />

OSMTT0201 A 7mmFemaleWindowCaliper<br />

OSMTT0202 B 9mmMaleWindowCaliper<br />

OSMTT0203 C FemaleWindowOutlineInstrument<br />

OSMTT0204 D MaleWindowOutlineInstrument<br />

OSMTT0205 E SmallCurvedHook<br />

OSMTT0206 F LargeCurvedHook<br />

OSMTT0207 G SmallSharpHook<br />

OSMTT0208 H LargeSharpHook<br />

OSMTT0209 I 3mmDuckbillEleva<strong>to</strong>r<br />

OSMTT0210 J 5mmDuckbillEleva<strong>to</strong>r<br />

OSMTT0211 K ChiselEleva<strong>to</strong>r<br />

OSMTT0212 L FemaleImplantInserter<br />

OSMTT0213 M MaleImplantInserter<br />

A<br />

B<br />

C D E F G H I J K L M<br />

Option 2 - Single Procedure Thyroplasty Kit<br />

Acost-effectiveandconvenien<strong>to</strong>ptiondesignedforsurgeonswhoperformalimitednumber<strong>of</strong>thyroplastyprocedures.Chooseeitherafemale<br />

ormalekit.Bos<strong>to</strong>nMedicalProductswillsendyouthecomplete13-pieceinstrumentsetinsterilisationtray,onedisposablemeasuringdevicekit,<br />

andfivethyroplastyimplants.Followingthesurgery,simplyreturntheinstrumentsetandfourunusedimplants.<br />

Montgomery®ThyroplastySurgicalInstruments,suppliednonsterile.<br />

OrderNo.<br />

OrderNo.<br />

OSMTS0001<br />

FemaleSingleProcedureKit<br />

OSMTS0002<br />

MaleSingleProcedureKit<br />

11


K A P I T E X H E A L T H C A R E - S P E C I A L I S T K N O W L E D G E , S U P P O R T A N D C A R E<br />

K A P I T E X H E A L T H C A R E - S P E C I A L I S T K N O W L E D G E , S U P P O R T A N D C A R E<br />

K a p i t e x h e a l t h c a r e - S p e c i a l i S t K n o w l e d g e , S u p p o r t a n d c a r e<br />

www.kapitex.com<br />

Visit our comprehensive website for the latest product information,<br />

news and resources.<br />

Also available from Kapitex…<br />

Specialist <strong>Airway</strong><br />

STENTING SOLUTIONS<br />

Tracheos<strong>to</strong>my<br />

CARE & MANAGEMENT SOLUTIONS<br />

<strong>Kapitex…Adding</strong> <strong>Quality</strong> <strong>of</strong> <strong>Life</strong><br />

<strong>to</strong> <strong>Airway</strong> <strong>Management</strong><br />

Effective Tracheos<strong>to</strong>my Care and<br />

<strong>Management</strong> Solutions<br />

Kapitex - Adding <strong>Quality</strong> <strong>of</strong> <strong>Life</strong> <strong>to</strong> <strong>Airway</strong> <strong>Management</strong><br />

Kapitex Healthcare provide a wide range <strong>of</strong> products dedicated <strong>to</strong> laryngec<strong>to</strong>my and tracheos<strong>to</strong>my care. You can depend on our<br />

experience, our product quality – and our quality <strong>of</strong> aftersales service. To order any <strong>of</strong> the products in this brochure or for details <strong>of</strong><br />

other Kapitex products contact Kapitex on 01937 580211, or by fax on 01937 580796 or write <strong>to</strong> us at the address below.<br />

Kapitex Healthcare Ltd.<br />

Kapitex House, 1 Sandbeck Way, Wetherby,<br />

West Yorkshire LS22 7GH, England.<br />

Tel: 01937 580211<br />

Fax: 01937 580796<br />

Email: sales@kapitex.com<br />

If dialling from outside the UK –<br />

Tel: +44 (0)1937 580 211 • Fax: +44 (0)1937 580796<br />

Due <strong>to</strong> continuous product<br />

developments it may be necessary <strong>to</strong><br />

alter without notice products within<br />

our range. We endeavour <strong>to</strong> keep all<br />

cus<strong>to</strong>mers informed <strong>of</strong> product<br />

improvements.<br />

Cert No 257<br />

© Kapitex Healthcare Ltd. 2012 PBOS0060 03/12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!