Notice<br />

d’utilisation / user guide<br />

Legrand cabling system LCS 2<br />

fibre optic<br />

fibre cables<br />

NEW<br />

customised<br />

fibre optic links<br />

FIBRES PRE-FITTED WITH CONNECTORS<br />

325 15<br />

325 06<br />

Length of link<br />

(from connector to connector in metres)<br />

Link supplied with protective sleeve<br />

and compression gland pull system<br />

to facilitate entry into the fibre optic<br />

enclosures<br />

Connectors:<br />

LC<br />

SC<br />

325 10<br />

Number of<br />

fibres:<br />

4, 6, 12<br />

ST<br />

325 08<br />

Fibre cables:<br />

• fibre colour code: FOTAG<br />

• standard: EN 50173-2, ISO IEC 11801<br />

Pack Cat.Nos OS 1 singlemode optical cables<br />

(9/125 µm)<br />

For 9/125 µm singlemode installations<br />

900 µm (OS 1)<br />

Loose tube Tight buffer Yellow jacket<br />

2000 (1) 325 12 Indoor/outdoor (universal)<br />

6 fibres<br />

2000 (1) 325 13 Outdoor, corrugated steel tape<br />

6 fibres<br />

2000 (1) 325 14 325 50 Indoor/outdoor (universal)<br />

12 fibres<br />

2000 (1) 325 15 Outdoor, corrugated steel tape<br />

12 fibres<br />

2000 (1) 325 51 Indoor/outdoor (universal) 24 fibres<br />

Type of sheath:<br />

Internal/External<br />

(glass anti-rodent protection)<br />

External (structure can be<br />

buried, reinforced ringed-steel<br />

protection)<br />

Fibre type<br />

Multimode: 62.5/125 µm<br />

Conforms with category OM1<br />

Multimode: 50/125 µm<br />

(ensured speed 1 Gbps)<br />

Conforms with category OM2<br />

Multimode: 50/125 µm<br />

(ensured speed 10 Gbps over 300m)<br />

Conforms with category OM3<br />

Monomode: 9/125 µm<br />

(ensured speed 10 Gbps)<br />

Conforms with category OS1<br />

OM 3 multimode optical cables<br />

(50/125 µm)<br />

For 50/125 µm multimode installations<br />

(OM 3)<br />

900 µm Green jacket<br />

Loose tube Tight buffer 10 Gigabit Ethernet compliant<br />

2000 (1) 325 10 Indoor/outdoor (universal)<br />

6 fibres<br />

2000 (1) 325 11 Indoor/outdoor (universal)<br />

12 fibres<br />

2000 (1) 325 53 325 52 Indoor/outdoor (universal)<br />

24 fibres<br />

OM 2 multimode optical cables<br />

(50/125 µm)<br />

For 50/125 µm multimode installations<br />

900 µm (OM 2)<br />

Loose tube Tight buffer Orange jacket<br />

2000 (1) 325 54 Indoor/outdoor (universal)<br />

2 fibres<br />

2000 (1) 325 59 325 55 Indoor/outdoor (universal)<br />

4 fibres<br />

2000 (1) 325 04 325 08 Indoor/outdoor (universal)<br />

6 fibres<br />

2000 (1) 325 05 Outdoor, corrugated steel tape<br />

6 fibres<br />

2000 (1) 325 06 325 09 Indoor/outdoor (universal)<br />

12 fibres<br />

2000 (1) 325 07 Outdoor, corrugated steel tape<br />

12 fibres<br />

2000 (1) 325 60 325 58 Indoor/outdoor (universal)<br />

24 fibres<br />

OM 1 multimode optical cables<br />

(62.5/125 µm)<br />

For 62.5/125 µm multimode installations<br />

(OM 1)<br />

900 µm Tight buffer Orange jacket<br />

2000 (1) 325 00 Indoor/outdoor (universal)<br />

6 fibres<br />

2000 (1) 325 01 Indoor/outdoor (universal)<br />

12 fibres<br />

DOCUMENTS<br />

Each link is supplied with a test report (fibre by fibre) and illustrated<br />

operating instructions<br />

Feuille de Contrôle / Control sheet<br />

Date : / / Code :<br />

Type : / Lg : M<br />

Int : Ext : Int - Ext<br />

Int : Interieur / Interior Ext : Exterieur / Exterior<br />

0, dB<br />

0, dB dB 0, 0, dB<br />

dB<br />

dB 0, dB<br />

dB 0, dB<br />

0, dB 0, dB<br />

0, dB 0, dB<br />

0, dB 0, dB<br />

0, B<br />

0, dB 0, dB<br />

0, dB 0, dB<br />

dB 0, dB<br />

0, 0, dB 0, dB<br />

0, 0, 0, dB fibre / fiber : FO ~850 nm<br />

A<br />

maximum ISO/CEI 11801 + TIA/EIA 568B3<br />

Ex. : lg 100m = 0,75. + (3,5 dB/km * 100)= 1,1dB<br />

Test TIA/EIA 455-171A méthode D1<br />

PACKAGING<br />

According to length of link:<br />

- packed<br />

on a reel<br />

- packed<br />

on a ring<br />

Connector protection by<br />

tube<br />

Reel<br />

(1) in metre(s)<br />

78