Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Notice<br />
d’utilisation / user guide<br />
Legrand cabling system LCS 2<br />
fibre optic<br />
fibre cables<br />
NEW<br />
customised<br />
fibre optic links<br />
FIBRES PRE-FITTED WITH CONNECTORS<br />
325 15<br />
325 06<br />
Length of link<br />
(from connector to connector in metres)<br />
Link supplied with protective sleeve<br />
and compression gland pull system<br />
to facilitate entry into the fibre optic<br />
enclosures<br />
Connectors:<br />
LC<br />
SC<br />
325 10<br />
Number of<br />
fibres:<br />
4, 6, 12<br />
ST<br />
325 08<br />
Fibre cables:<br />
• fibre colour code: FOTAG<br />
• standard: EN 50173-2, ISO IEC 11801<br />
Pack Cat.Nos OS 1 singlemode optical cables<br />
(9/125 µm)<br />
For 9/125 µm singlemode installations<br />
900 µm (OS 1)<br />
Loose tube Tight buffer Yellow jacket<br />
2000 (1) 325 12 Indoor/outdoor (universal)<br />
6 fibres<br />
2000 (1) 325 13 Outdoor, corrugated steel tape<br />
6 fibres<br />
2000 (1) 325 14 325 50 Indoor/outdoor (universal)<br />
12 fibres<br />
2000 (1) 325 15 Outdoor, corrugated steel tape<br />
12 fibres<br />
2000 (1) 325 51 Indoor/outdoor (universal) 24 fibres<br />
Type of sheath:<br />
Internal/External<br />
(glass anti-rodent protection)<br />
External (structure can be<br />
buried, reinforced ringed-steel<br />
protection)<br />
Fibre type<br />
Multimode: 62.5/125 µm<br />
Conforms with category OM1<br />
Multimode: 50/125 µm<br />
(ensured speed 1 Gbps)<br />
Conforms with category OM2<br />
Multimode: 50/125 µm<br />
(ensured speed 10 Gbps over 300m)<br />
Conforms with category OM3<br />
Monomode: 9/125 µm<br />
(ensured speed 10 Gbps)<br />
Conforms with category OS1<br />
OM 3 multimode optical cables<br />
(50/125 µm)<br />
For 50/125 µm multimode installations<br />
(OM 3)<br />
900 µm Green jacket<br />
Loose tube Tight buffer 10 Gigabit Ethernet compliant<br />
2000 (1) 325 10 Indoor/outdoor (universal)<br />
6 fibres<br />
2000 (1) 325 11 Indoor/outdoor (universal)<br />
12 fibres<br />
2000 (1) 325 53 325 52 Indoor/outdoor (universal)<br />
24 fibres<br />
OM 2 multimode optical cables<br />
(50/125 µm)<br />
For 50/125 µm multimode installations<br />
900 µm (OM 2)<br />
Loose tube Tight buffer Orange jacket<br />
2000 (1) 325 54 Indoor/outdoor (universal)<br />
2 fibres<br />
2000 (1) 325 59 325 55 Indoor/outdoor (universal)<br />
4 fibres<br />
2000 (1) 325 04 325 08 Indoor/outdoor (universal)<br />
6 fibres<br />
2000 (1) 325 05 Outdoor, corrugated steel tape<br />
6 fibres<br />
2000 (1) 325 06 325 09 Indoor/outdoor (universal)<br />
12 fibres<br />
2000 (1) 325 07 Outdoor, corrugated steel tape<br />
12 fibres<br />
2000 (1) 325 60 325 58 Indoor/outdoor (universal)<br />
24 fibres<br />
OM 1 multimode optical cables<br />
(62.5/125 µm)<br />
For 62.5/125 µm multimode installations<br />
(OM 1)<br />
900 µm Tight buffer Orange jacket<br />
2000 (1) 325 00 Indoor/outdoor (universal)<br />
6 fibres<br />
2000 (1) 325 01 Indoor/outdoor (universal)<br />
12 fibres<br />
DOCUMENTS<br />
Each link is supplied with a test report (fibre by fibre) and illustrated<br />
operating instructions<br />
Feuille de Contrôle / Control sheet<br />
Date : / / Code :<br />
Type : / Lg : M<br />
Int : Ext : Int - Ext<br />
Int : Interieur / Interior Ext : Exterieur / Exterior<br />
0, dB<br />
0, dB dB 0, 0, dB<br />
dB<br />
dB 0, dB<br />
dB 0, dB<br />
0, dB 0, dB<br />
0, dB 0, dB<br />
0, dB 0, dB<br />
0, B<br />
0, dB 0, dB<br />
0, dB 0, dB<br />
dB 0, dB<br />
0, 0, dB 0, dB<br />
0, 0, 0, dB fibre / fiber : FO ~850 nm<br />
A<br />
maximum ISO/CEI 11801 + TIA/EIA 568B3<br />
Ex. : lg 100m = 0,75. + (3,5 dB/km * 100)= 1,1dB<br />
Test TIA/EIA 455-171A méthode D1<br />
PACKAGING<br />
According to length of link:<br />
- packed<br />
on a reel<br />
- packed<br />
on a ring<br />
Connector protection by<br />
tube<br />
Reel<br />
(1) in metre(s)<br />
78