Legrand cabling system LCS 2<br />

19" LCS 2 enclosures and server enclosures<br />

n General characteristics<br />

Metallic extendable enclosures. RAL 7016 textured polyester coating providing excellent resistance to corrosion and scratching<br />

Front glass safety door, front and rear microperforated metal doors for server enclosures<br />

Protection index (weatherproof) against solid objects and liquids: IP 20. Protection index against mechanical shocks: IK 08<br />

Perforations in 19" uprights: 9.5 x 9.5 mm. Permissible load: 10 kg/U (or 420 kg for a 42 U enclosure), 15 kg/U for server enclosure<br />

n Compliance with standards<br />

LCS 2 enclosures comply with the following standards:<br />

IEC 60529<br />

EN 60529<br />

IEC 62262<br />

EN 62262<br />

IEC 60950-1<br />

EN 60950-1<br />

C 77-210-1<br />

EIA-310-D<br />

IEC 60297-1 and 2<br />

DIN 41414-7<br />

IEC 60917-1<br />

EN 60917-1<br />

IEC 60917-2-1<br />

EN 60917-2-1<br />

(NF C 20-010) Degrees of protection provided by enclosures<br />

(IP code)<br />

(NF EN 50102, NF C 20-015) Degree of protection provided by enclosures<br />

of electrical equipment against external mechanical impacts (IK code)<br />

Safety of data processing equipment<br />

Cabinets, enclosures, panels and associated equipment<br />

(ANSI/EIA/310-D-1992)<br />

(NF C 20-150, NF C 20-151) Sizes of mechanical structures<br />

of the 482.6 mm (19 in) series<br />

Modular order for the development of mechanical structures for<br />

electronic infrastructures<br />

Modular order for the development of mechanical structures<br />

for electronic infrastructures Coordination dimensions for infrastructure<br />

interfaces in widths of 25 mm (enclosure and frame dimensions)<br />

LCS 2 enclosures can be integrated into installations complying with the<br />

following standards:<br />

EN 50173-1<br />

EN 50174-1 & 2<br />

C 90-480-1 & 2<br />

ISO IEC 11801<br />

NF C 15-100<br />

Part 4-41<br />

Information technology - Generic cabling systems<br />

Information technology - Cabling installation<br />

Information technology - Generic cabling for customer premises<br />

Low voltage electrical installations - Recommendations<br />

D<br />

P<br />

H<br />

H<br />

L<br />

n Overall dimensions (mm)<br />

L<br />

A<br />

A<br />

B<br />

B<br />

Cat.Nos Capacity H (1) L D A B<br />

463 00 24 U 1226<br />

463 06 29 U 1448<br />

659<br />

463 12 33 U 1626 610 1138 1208<br />

463 18/30<br />

160° 463 19 859<br />

160°<br />

463 21 42 U 2026 657<br />

1408<br />

463 22/33 857 1608<br />

463 23 810 1057 1525 1808<br />

463 28<br />

857 1608<br />

47 U 2248<br />

463 29 1057 1808<br />

Server enclosures<br />

Cat.Nos Capacity H (1) L D A B<br />

463 85 42 U 2026 610 1092 1138 1608<br />

463 86 42 U 2026 810 1092 1525 1808<br />

n Useable dimensions<br />

600<br />

800<br />

Cat.Nos Capacity A<br />

463 00 24 U<br />

Usable area<br />

F (2)<br />

E<br />

B C D Min. Max.<br />

1086<br />

G<br />

A<br />

A<br />

463 06 29 U 1308<br />

659<br />

463 12 33 U 1486<br />

463 18/30<br />

490<br />

490 425<br />

118 193 41<br />

463 19 859 690 625<br />

D<br />

C<br />

D<br />

C<br />

463 21 42 U 657 1886 490 425<br />

463 22/33 857 690 625<br />

463 23 1057 690 890 825<br />

122 197 141<br />

87 (2)<br />

(maximum 162)<br />

G<br />

E<br />

450<br />

Usable<br />

area<br />

465<br />

Distance<br />

B<br />

87 (2)<br />

(maximum 162)<br />

G<br />

E<br />

450<br />

Usable<br />

area<br />

465<br />

Distance<br />

B<br />

463 28<br />

857 690 625<br />

47 U 2108<br />

463 29 1057 890 825<br />

Server enclosures<br />

Cat.Nos Capacity A<br />

Usable area<br />

F (2)<br />

E<br />

B C D Min. Max.<br />

G<br />

463 85 42 U 1092 1886 490 890 825 122 197 41<br />

463 86 42 U 1092 1886 690 890 825 122 197 141<br />

F (2)<br />

Min/Max<br />

F (2)<br />

Min/Max<br />

(1) Without adjustment levelling feet (+15 to 45 mm with feet)<br />

(2) Continuous adjustment with adjustments in widths of 12.5 mm<br />