07.12.2012 Views

LF-Hy-1 LF-Hy-1-DV - HANSA Klima

LF-Hy-1 LF-Hy-1-DV - HANSA Klima

LF-Hy-1 LF-Hy-1-DV - HANSA Klima

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Airscreen Devices for Fresh Produce Outlets<br />

You care for your fresh produce and present<br />

it to your customers following the regulations.<br />

We support you with our airscreen solutions<br />

<strong>LF</strong>-<strong>Hy</strong>-1 und <strong>LF</strong>-<strong>Hy</strong>-1-<strong>DV</strong>.<br />

Pioneering airscreen devices for fresh produce<br />

outlets, we significantly influenced the DIN<br />

10505 and continuously improve our systems.<br />

Since decades, we offer inexpensive devices<br />

meeting all regulations and optimized for low<br />

energy consumption.<br />

• efficient technology<br />

• low energy consumption<br />

• customizable<br />

• complies to DIN 10505<br />

• perfect hygiene<br />

Quality of air means quality of life [and food]<br />

<strong>LF</strong>-<strong>Hy</strong>-1<br />

<strong>LF</strong>-<strong>Hy</strong>-1-<strong>DV</strong><br />

<strong>HANSA</strong> aircreen devices make use of the Coanda effect, guiding<br />

the airflow along the inside of the glass panel. This way, your<br />

fresh produce will stay untainted while your customers not even<br />

notice the air screen.<br />

As a further advantage, the <strong>HANSA</strong> system requires less airflow<br />

than any other solution, leading to reduced energy consumption,<br />

and therefore keeps down costs.<br />

We are exclusively using recirculating air since usually no air handling<br />

except filtering is needed. Of course, if necessary the <strong>LF</strong>-HY-<br />

1-<strong>DV</strong> can be seamlessly integrated in your refrigerating plant (heat<br />

exchanger, thermostat, and three valves included).<br />

A HEPA filter ensures sterile air, supported by a prefilter to expand<br />

its durability.<br />

On top of everything:<br />

Our devices are engineered and made in Germany. For your safety.


The <strong>HANSA</strong> system:<br />

Our system requires a rig slot size of 3 mm and<br />

an airflow velocity of 6 m/s. It immediately follows<br />

a volume flow<br />

Technical Data<br />

V L = 0,003 m x 1 m x 6 m/s<br />

per meter to keep up the airscreen. To maintain<br />

overpressure required by the regulations, an additional<br />

volume flow<br />

V O = V L / 2.<br />

is necessary. Seperating the volume flows accordingly<br />

is done by ducting.<br />

We find for different counter lengths:<br />

Length [m] Volume flow [m3 /h]<br />

1 97<br />

2 194<br />

3 292<br />

4 389<br />

5 486<br />

6 583<br />

7 680<br />

8 778<br />

9 875<br />

10 972<br />

Please account for a pressure loss at maximum<br />

filter load.<br />

Ventilator<br />

Volume flow 100 - 1000 m3 /h<br />

Power consumption 0,54 kW<br />

Voltage 230 V, 50 Hz<br />

Prefilter<br />

Type F5<br />

Pressure loss 32 Pa at 1000 m3 /h<br />

HEPA<br />

Type H13<br />

Pressure loss 165 Pa at 1000 m3 Direct Heat Exchanger<br />

/h<br />

Type Cu / Al<br />

Refrigerant R404A<br />

Cooling capacity 5,71 kW<br />

Pressure loss 44 Pa<br />

Office North<br />

D-26969 Butjadingen-Stollhamm<br />

Ulmenstraße 2<br />

Tel.: +49 4735 810120<br />

Fax: +49 4735 810116<br />

Office East<br />

D-04431 Schkeuditz<br />

Paetzstraße 2<br />

Tel.: +49 34204 65585<br />

Fax: +49 34204 65586<br />

Office Bielefeld<br />

D-33803 Steinhagen<br />

Rote Erde 32<br />

Tel.: +49 5204 8002868<br />

Fax: +49 5204 8002869<br />

Office Central<br />

D-35305 Grünberg<br />

An der Stadtkirche 10<br />

Tel.: +49 6401 210324<br />

Fax: +49 6401 222560<br />

<strong>HANSA</strong> Ventilatoren und Maschinenbau Neumann GmbH<br />

Stockweg 19<br />

D-26683 Saterland / Strücklingen<br />

Tel. +49 449889 - 0<br />

Fax +49 4498687<br />

E-Mail info@hansa-klima.de<br />

Internet www.hansa-klima.de<br />

B72<br />

Wittensander Straße<br />

Stockweg<br />

outside<br />

air sterile primary airflow<br />

outer<br />

secondary<br />

airflow<br />

height of<br />

pass-through [m]<br />

(0,6 m at max.)<br />

Office West<br />

D-45731 Waltrop<br />

Dortmunder Straße 43<br />

Tel.: +49 2309 71071<br />

Fax: +49 2309 71826<br />

Office South-West<br />

D-66299 Friedrichsthal<br />

Saarbrücker Straße 75<br />

Tel.: +49 6897 812520<br />

Fax: +49 6897 812521<br />

Hauptstraße

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!