27.11.2015 Views

Simscape Reference

Pipe (TL)

Pipe (TL)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Constant Area Pneumatic Orifice (ISO 6358)<br />

• Cv coefficient (USCU) — Provide value for the flow coefficient specified in<br />

US units. This value is internally converted by the block into an equivalent value<br />

for the orifice effective area.<br />

• Kv coefficient (SI) — Provide value for the flow coefficient specified in SI<br />

units. This value is internally converted by the block into an equivalent value for<br />

the orifice effective area.<br />

Sonic conductance<br />

Specify the sonic conductance of the orifice, that is, the ratio between the mass<br />

flow rate and the product of upstream pressure and the mass density at standard<br />

conditions when the flow is choked. This value depends on the geometrical properties<br />

of the orifice, and usually is provided in textbooks or manufacturer data sheets. The<br />

default value is 1.6 l/s/bar. This parameter appears in the dialog box if Orifice is<br />

specified with parameter is set to Sonic conductance.<br />

Effective area<br />

Specify the orifice cross-sectional area. The default value is 1e-5 m^2. This<br />

parameter appears in the dialog box if Orifice is specified with parameter is set to<br />

Effective area.<br />

Cv coefficient<br />

Specify the value for the flow coefficient in US units. The default value is 0.6. This<br />

parameter appears in the dialog box if Orifice is specified with parameter is set to<br />

Cv coefficient (USCU).<br />

Kv coefficient<br />

Specify the value for the flow coefficient in SI units. The default value is 8.5. This<br />

parameter appears in the dialog box if Orifice is specified with parameter is set to<br />

Kv coefficient (SI).<br />

Critical pressure ratio<br />

Specify the critical pressure ratio, that is, the ratio between the downstream pressure<br />

and the upstream pressure at which the gas velocity achieves sonic speed. The<br />

default value is 0.528.<br />

Pressure ratio at laminar flow<br />

Specify the ratio between the downstream pressure and the upstream pressure at<br />

laminar flow. This value can be in the range between 0.995 and 0.999. The default<br />

value is 0.999.<br />

<strong>Reference</strong> temperature<br />

1-41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!