10.02.2016 Views

Up-to-Date 350-080 Exam BrainDumps

Test4Direct provides latest PDF questions of Cisco 350-080 exam. You have an opportunity to pass the Cisco 350-080 exam in one go. Test4Direct is most accurate source to prepare Cisco 350-080 exam as your success will become site’s responsibility after purchasing 350-080 exam product. There are also lots of discounts and promotion offers that you can avail. Let’s try a free demo http://www.test4direct.com/350-080.html

Test4Direct provides latest PDF questions of Cisco 350-080 exam. You have an opportunity to pass the Cisco 350-080 exam in one go. Test4Direct is most accurate source to prepare Cisco 350-080 exam as your success will become site’s responsibility after purchasing 350-080 exam product. There are also lots of discounts and promotion offers that you can avail. Let’s try a free demo http://www.test4direct.com/350-080.html

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The port channel pro<strong>to</strong>col expands the port channel functional model in Cisco SAN switches. It uses<br />

the exchange peer parameters (EPP) services <strong>to</strong> communicate across peer ports in an ISL. Each switch<br />

uses the information received from the peer ports along with its local configuration and operational<br />

values <strong>to</strong> decide if it should be part of a SAN port channel. The pro<strong>to</strong>col ensures that a set of ports<br />

are eligible <strong>to</strong> be part of the same SAN port channel. They are only eligible <strong>to</strong> be part of the same<br />

port channel if all the ports have a compatible partner.<br />

Explanation:<br />

Reference:<br />

http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/san_switching/b_Cisco<br />

_Nexus_5000_Series_NX-OS_SAN_Switching_Configuration_Guide/Cisco_Nexus_5000_Series_NX -<br />

OS_SAN_Switching_Configuration_Guide_chapter7.html (san port channel pro<strong>to</strong>col)<br />

Question: 7<br />

Which statement about SAN port channels configured on Cisco Nexus 5000 Series Switches is true?<br />

A. A single SAN port channel can have both Fibre Channel and virtual Fibre Channel interfaces.<br />

B. SAN port channels can include up <strong>to</strong> 16 interfaces.<br />

C. SAN port channels distribute traffic across all links in the port channel when source ID and<br />

destination ID load balancing are used.<br />

D. The links in SAN port channels can be connected <strong>to</strong> different sets of switches.<br />

E. The On mode of operation means ports only operate as part of a SAN port channel or remain<br />

inactive.<br />

Question: 8<br />

Answer: E<br />

Explanation:<br />

You can configure each SAN port channel with a channel group mode parameter <strong>to</strong> determine the<br />

port channel pro<strong>to</strong>col behavior for all member ports in this channel group. The possible values for a<br />

channel group mode are as follows:<br />

On (default)—The member ports only operate as part of a SAN port channel or remain inactive. In<br />

this mode, the port channel pro<strong>to</strong>col is not initiated. However, if a port channel pro<strong>to</strong>col frame is<br />

received from a peer port, the software indicates its nonnegotiable status. Port channels configured<br />

in the On mode require you <strong>to</strong> explicitly enable and disable the port channel member ports at either<br />

end if you add or remove ports from the port channel configuration. You must physically verify that<br />

the local and remote ports are connected <strong>to</strong> each other.<br />

Active—The member ports initiate port channel pro<strong>to</strong>col negotiation with the peer port(s) regardless<br />

of the channel group mode of the peer port. If the peer port, while configured in a channel group,<br />

does not support the port channel pro<strong>to</strong>col, or responds with a nonnegotiable status, it will default<br />

<strong>to</strong> the On mode behavior. The Active port channel mode allows au<strong>to</strong>matic recovery without explicitly<br />

enabling and disabling the port channel member ports at either end.<br />

Explanation:<br />

Reference:<br />

http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/san_switching/b_Cisco<br />

_Nexus_5000_Series_NX-OS_SAN_Switching_Configuration_Guide/Cisco_Nexus_5000_Series_NX -<br />

OS_SAN_Switching_Configuration_Guide_chapter7.html<br />

Which capabilities are not supported in DCNM device manager?

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!