07.12.2012 Views

Central Battery System - Lumentron Electronic Kft.

Central Battery System - Lumentron Electronic Kft.

Central Battery System - Lumentron Electronic Kft.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Central</strong> <strong>Battery</strong> <strong>System</strong><br />

Typ CPS 0/64/SV<br />

Catalogue<br />

CPS 220/64<br />

Sicherheitstechnik GmbH


INOTEC Sicherheitstechnik GmbH is a company<br />

with the target to create innovative and<br />

customer oriented solutions for the Emergency<br />

Lighting market.<br />

A dynamic team of highly professional and<br />

flexible employees covers all aspects regarding<br />

products, engineering and standards.<br />

Modern, technical advanced products set new<br />

standards world wide, i.e. JOKER technology for<br />

Emergency Lighting <strong>System</strong>s or the Dynamic<br />

Escape Routing concept realised in the D.E.R.-<br />

<strong>System</strong>.<br />

This catalogue contains the INOTEC Standard<br />

<strong>Central</strong> <strong>Battery</strong> Emergency Lighting <strong>System</strong>s<br />

CPS 0/64/SV and some complementing<br />

products. Should you require additional functions<br />

or special features please do not hesitate<br />

to ask our regional technical sales team for<br />

support.<br />

Copyright: INOTEC Sicherheitstechnik GmbH, Ense<br />

Publications and copies, even partial, only with<br />

manufacturers permission.<br />

Subject to technical changes.<br />

Content<br />

CPS 0/64/SV<br />

New standards allow new ideas!<br />

Page<br />

Function, design and features 3 - 5<br />

<strong>Central</strong> monitoring 6 / 7<br />

Technical data / system overview 8 - 10<br />

Joker - Technique 11<br />

<strong>System</strong> - components and options 12 - 17<br />

<strong>System</strong> planing and technical tables 18 - 19


CPS 0/64/SV<br />

Function, design and features<br />

The CPS 220 series covers various load<br />

requirements and housing sizes. Joker-Technology,<br />

individual lamp- and circuit monitoring<br />

are our standard<br />

<strong>System</strong> features<br />

� Modular design, various enclosure sizes for<br />

main-, substations, battery-racks and battery<br />

enclosures<br />

� Up to 1 circuits (64 out of the main system<br />

/ 64 out of substations) with 0 addresses<br />

can be supplied<br />

� Low maintenance and service costs due<br />

to central monitoring of stations and all<br />

connected luminaires<br />

� Automated or manually releasing function<br />

test facility with logbook for status and failure<br />

information<br />

� Earth failure measurement and test facility<br />

� Isolation terminals for easy earth failure<br />

measurements<br />

� Sealed lead acid gas recombination OGIbatteries<br />

with >10 year design life<br />

� Galvanically isolated internal- and external<br />

bus-system<br />

� Separated monitoring- and change-over<br />

devices for maintained-/non-maintained<br />

light<br />

�<br />

Patented “Joker-Technology” function for<br />

mixed operation of maintained, non-maintained<br />

and switched luminaires on one line<br />

Network-compatible, graphics based controller<br />

� 5,6’’ TFT- Display<br />

� Intuitive, single button operation<br />

� Password protected programming<br />

� Integrated network connection interface<br />

(InoWeb)<br />

� USB-interface to<br />

� load / safe the system confi guration<br />

� load / safe the circuit confi guration (operation<br />

mode, monitoring depth, destination texts…)<br />

� connect a standard printer (pcl-compatible) or key-board<br />

� Administration of up to 1 circuits (max. .560 luminaires – 0 addresses per circuit)<br />

� Automatic function monitoring of system including single luminaire- and circuit failures without<br />

additional data-line<br />

� Integrated logbook for central compilation and > year storage of all system related data<br />

� Circuit-/luminaire function modes free programmable<br />

� Various languages available<br />

3


4<br />

Staircase 2. OG<br />

Staircase<br />

E0<br />

CPUSB<br />

1. OG<br />

EG<br />

UG<br />

1 . . . 20<br />

1 . . . 20<br />

1 . . . 20<br />

CPS220<br />

E30<br />

1 . . . 20<br />

1 . . . 20<br />

MDB<br />

E30<br />

CPUSB<br />

CPUSB<br />

E30<br />

CPUSB<br />

CPUSB<br />

E30<br />

1 . . . 20<br />

1 . . . 20<br />

Sub DB<br />

Sub DB<br />

1 . . . 20 1 . . . 20<br />

CPUSB<br />

CPUSB<br />

CPS220<br />

E30<br />

CPUSB<br />

1 . . . 20<br />

1 . . . 20<br />

Staircase Staircase<br />

Sub DB<br />

MDB<br />

Sub DB<br />

Sub DB<br />

Sub DB<br />

Sub DB<br />

Sub DB<br />

E0<br />

CPS 0/64/SV<br />

Function, design and features<br />

Modular central power supply systems<br />

allow, depending on the building layout,<br />

the local building standards and the purpose/usage<br />

of the building, various design<br />

approaches for optimal cost efficiency.<br />

Essentially two well-defined systems can be<br />

found.<br />

The classic <strong>Central</strong> <strong>Battery</strong> <strong>System</strong>:<br />

Supplies the complete<br />

building via lighting circuits<br />

running into every part of<br />

the structure. All circuits are<br />

1 . . . 20<br />

terminated on one system<br />

only. This is an advantage in<br />

smaller objects but might<br />

not be the best solution as<br />

long cable runs and function<br />

1 . . . 20<br />

preservation of the circuits<br />

create higher costs.<br />

The adapted <strong>Central</strong> <strong>Battery</strong> <strong>System</strong>:<br />

UVA<br />

CPUSB<br />

Supplies the complete<br />

building via circuits run<br />

from main- and substations.<br />

Depending on the requirements<br />

of every floor or<br />

building segment, individually<br />

adapted substations<br />

are used. Load and specific<br />

luminaire requirements,<br />

i.e. luminaires in protection<br />

class III (SELV – safety extra<br />

low voltage) are taken care<br />

of and lead to new system<br />

concepts with 0V and/or<br />

4V output circuits.


CPS 0/64/SV<br />

Function, design and features<br />

Substation CPUSB 220 / 64 / 24V<br />

for 24V INOTEC LED - Safety- and Exit luminaires<br />

� Automatic function monitoring of all<br />

connected luminaires<br />

� Independent system with “Joker-Technique”<br />

function: mixed operation of maintained,<br />

non-maintained and switched luminaires<br />

� 4V luminaires individually programmable,<br />

dimmable and addressable via controller<br />

� Controller with 4 x 0 characters; various<br />

languages settable<br />

� Control, administration and failure display<br />

for 0 luminaires addresses per output<br />

� 4 output circuits in protection class III (SELV)<br />

for 0 luminaires / each output<br />

� Two programmable switch inputs for each<br />

luminaire<br />

� Dimmlevel setting for each individual luminaire<br />

or single circuits<br />

� Luminaire addressing via search-and-store<br />

controller function or manually<br />

� Statusinfo for system and luminaires via<br />

display and LEDs<br />

� Voltfree contacts for external status display<br />

� Switch contact for remote blocking facility<br />

Substation CPUSB 220 / 64 / 1…<br />

Decentral substation for standard LED- / FL<br />

- Safety- and Exit luminaires<br />

� Substations for 30V AC / 0V DC luminaires<br />

� Standardised panel sizes<br />

� For local AC supply<br />

� Outputs for 4x A and x4A<br />

� Joker Technique, mixed operation maintained,<br />

non-maintained and switched<br />

programmable<br />

� Three switch input per circuit<br />

� Modular, allowing fl exibility for special<br />

applications<br />

Emergency lighting bus-substation with<br />

controller<br />

Technical data:<br />

Mains operation: 30V AC +/-10%<br />

<strong>Battery</strong> operation: 0V DC +10%/-15%<br />

Output voltage: 4V DC +/- 0%<br />

<strong>System</strong> protection class: I / IP 0<br />

Emergency lighting bus-substation without<br />

controller<br />

Technical data:<br />

Mains operation: 30V AC +/-10%<br />

<strong>Battery</strong> operation: 0V DC +10%/-15%<br />

<strong>System</strong> protection class: I / IP 0<br />

5


6<br />

InoWeb – Control – Functionality<br />

� For up to 3 INOTEC CPS- /<br />

CLS- systems<br />

� Automatic function test-/<br />

battery duration test cycles<br />

programmable<br />

� Logbook function for all<br />

connected systems<br />

� Automatically triggered e-mail,<br />

preset depending on programmable<br />

cycles, tests or failures<br />

� <strong>System</strong> tray list icon for general<br />

system info (all systems)<br />

<strong>System</strong> requirements:<br />

Operating system: Win / 000/<br />

XP/Vista<br />

Screen: VGA (640 x 4 0), 56<br />

colours<br />

00 MB free hard disc capacity ( 5<br />

MB without logbook)<br />

Network-interface: Ethernet, TCP/<br />

IPv4, HTTP<br />

Internetbrowser: MS Internet<br />

Explorer, Firefox, Opera,…)<br />

Switch<br />

Switch<br />

Netz<br />

16AT<br />

Ladeteil 220V/7,5A<br />

CPS 0/64/SV<br />

Function, design and features<br />

The administration and control of complex installations, even fi tted with different systems<br />

like CLS24/SV, CPS 220/48/SV and CPS 220/64/SV, can be easily achieved with INOTECs Software<br />

InoWeb – Control.<br />

To access all systems information it is only necessary to connect the TFT-controller of the<br />

CPS 220/64/SV to an already existing network.<br />

Main Hotelbuilding Operation <strong>System</strong>fail.: noner<br />

First floor Test <strong>System</strong>fail.<br />

First floor Failure Failure<br />

[no location text] blocked [NM und M]<br />

Intranet / Company network<br />

CPS 220/64/11KW<br />

with TFT incl. InoWeb<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

CPS 220 / 64<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

CPS 220 / 64<br />

Netz<br />

16AT<br />

Ladeteil 220V/7,5A<br />

Ein<br />

Ein<br />

10AT<br />

10AT<br />

Batterie<br />

Batterie<br />

CPS 220/64/11KW<br />

with TFT incl. InoWeb<br />

CPS 220/64/11KW<br />

with TFT incl. InoWeb<br />

Router<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

CPS 220 / 64<br />

Netz<br />

Netz<br />

16AT<br />

Ladeteil 220V/7,5A<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

3,15A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

CPS 220 / 64<br />

16AT<br />

Ladeteil 220V/7,5A<br />

Ein<br />

Ein<br />

10AT<br />

10AT<br />

Batterie<br />

Batterie<br />

CPS 220/64/11KW<br />

with TFT incl. InoWeb


CPS 0/64/SV<br />

Function, design and features<br />

Individual emergency lighting systems<br />

can be administered without<br />

any special software from every<br />

network compatible / internet<br />

compatible PC.<br />

The TFT-controller allows (optional<br />

password-protected) monitoring<br />

and display of the system, the<br />

circuits and every individual luminaire.<br />

If an internet connection exists,<br />

this complete functionality can be<br />

achieved from a remote internet<br />

connected PC.<br />

To demonstrate / access an existing<br />

installation please contact our<br />

regional offi ces.<br />

Internet<br />

InoWeb functionality to monitor a single<br />

panel<br />

� Included in TFT-controller<br />

� Network interface part of TFT-controller<br />

� Visualisation of panel/luminaire status via<br />

HTML-page with Standard-Webbrowser (MS<br />

Internet Explorer, Firefox, Opera….)<br />

�<br />

Manual or dynamic network settings (via<br />

DHCP)<br />

7


CPS 0/64/SV<br />

Technical data: CPS 220 / 64 / 11kW-1 CPS 220 / 64 / 11kW-2 CPS 220 / 64 / 11kW-1<br />

3-phasig<br />

Protection class: I<br />

Protection category: IP 0<br />

Perm. ambient temperature<br />

for system: -5°C bis +35°C<br />

for battery: see battery data sheet<br />

<strong>Battery</strong> voltage: 0V DC<br />

Housing color: RAL 7035<br />

Plinth (optional) 100mm or 00mm<br />

30 mm<br />

1 00 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

CPS 220 / 64<br />

16AT<br />

Ladeteil 220V/7,5A<br />

INOTEC<br />

Betrieb<br />

Depth<br />

400 mm<br />

Batt.-Betrieb<br />

Störung<br />

Lade-<br />

Störung<br />

Drucker Centronics<br />

Key-Board<br />

Reset<br />

R T<br />

00 mm<br />

Ein<br />

10AT<br />

Batterie<br />

Technical data, systems overview<br />

CPS 220 / 64 / 11kW<br />

3-phasig<br />

Rated voltage: 1~N/PE, 230V AC 1~N/PE, 230V AC 3~N/PE, 400V AC 3~N/PE, 400V AC<br />

10%, 50/60Hz 10%, 50/60Hz 10%, 50/60Hz 10%, 50/60Hz<br />

<strong>System</strong> current: Intern 50 A 50 A 50 A 50 A<br />

total 50 A 50 A 50 A 50 A<br />

max. Load 11 kW 11 kW 11 kW 11 kW<br />

Max. installed battery capacity 75 Ah 75 Ah 75 Ah -<br />

Charger<br />

Circuit modules (4x2 A, 2x4 A, 1x6 A)<br />

1 x 3 A or 7,5 A 2 x 3 A or 7,5 A 1 x 3 A or 7,5 A max. 4 x 3A or 7,5A<br />

max. intern 16 16 16 16<br />

max. extern 16 16 16 16<br />

Mains supply 35 35 35 35<br />

<strong>Battery</strong> supply 35 35 35 35<br />

Outgoing to luminaires 4 4 4 4<br />

Data line (RTG) 4 4 4 4<br />

4V monitoring 4 4 4 4<br />

Supply cable 35 35 35 35<br />

BUS-line IB 4 4 4 4<br />

Mains to CPUS 35 35 35 35<br />

<strong>Battery</strong> to CPUS 35 35 35 35<br />

Dimensions H x W x D (mm) 2030 x 800 x 400 2230 x 800 x 400 2230 x 800 x 400 2000 x 800 x 400<br />

With function preservation (option) - - - -<br />

- with function preservation - - - -<br />

Cable inlets 22 x M 20 22 x M 20 22 x M 20 20 x M 20<br />

64 x M 25 64 x M 25 64 x M 25 50 x M 25<br />

6 x M 32 6 x M 32 6 x M 32 4 x M 40<br />

2 x M 50 2 x M 50 2 xM 50<br />

Termination box US-BUS<br />

Neozed 4 Outgoings *1 4 Outgoings *1 in option slot in option slot<br />

NH00 fuse 1 Outgoing *1 1 Outgoing *1 1 Outgoing *2 1 Outgoing *2<br />

Space for options 2 x 8 TE 2 x 8 TE 8 TE 1 x 27 TE *3<br />

1 x 4 TE 1 x 4 TE 1 x 6 TE<br />

Space required for battery fuses NH00<br />

- - - 2 TE<br />

Cable inlets top top top top or bottom<br />

1030 mm<br />

1 00 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

Netz<br />

CPS 220 / 64<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

INOTEC<br />

Betrieb<br />

Depth<br />

400 mm<br />

Batt.-Betrieb<br />

Störung<br />

Lade-<br />

Störung<br />

Drucker Centronics<br />

Key-Board<br />

Reset<br />

R T<br />

00 mm<br />

Ein<br />

Ein<br />

10AT<br />

10AT<br />

Batterie<br />

Batterie<br />

1030 mm<br />

1 00 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

CPS 220 / 64<br />

16AT<br />

Ladeteil 220V/7,5A<br />

INOTEC<br />

Betrieb<br />

Depth<br />

400 mm<br />

Batt.-Betrieb<br />

Störung<br />

Lade-<br />

Störung<br />

Drucker Centronics<br />

Key-Board<br />

Reset<br />

R T<br />

00 mm<br />

Ein<br />

10AT<br />

Batterie<br />

000 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

Netz<br />

Netz<br />

Netz<br />

CPS 220 / 64<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

INOTEC<br />

Betrieb<br />

Depth<br />

400 mm<br />

Batt.-Betrieb<br />

Störung<br />

Lade-<br />

Störung<br />

Drucker Centronics<br />

Key-Board<br />

Reset<br />

R T<br />

00 mm<br />

Ein<br />

Ein<br />

Ein<br />

Ein<br />

10AT<br />

10AT<br />

10AT<br />

10AT<br />

Batterie<br />

Batterie<br />

Batterie<br />

Batterie


CPS 0/64/SV<br />

Technical data, systems overview<br />

CPS 220 / 64 / 22kW<br />

3-phasig<br />

000 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

Netz<br />

Netz<br />

Netz<br />

CPS 220 / 64<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

16AT<br />

Ladeteil 220V/7,5A<br />

INOTEC<br />

Betrieb<br />

Depth<br />

400 mm<br />

Batt.-Betrieb<br />

Störung<br />

Lade-<br />

Störung<br />

Drucker Centronics<br />

Key-Board<br />

Reset<br />

R T<br />

00 mm<br />

Ein<br />

Ein<br />

Ein<br />

Ein<br />

10AT<br />

10AT<br />

10AT<br />

10AT<br />

Batterie<br />

Batterie<br />

Batterie<br />

Batterie<br />

CPS 220 / 20 / 1,2A CPS 220 / 20 / 3A CPS 220 / 20 / 5,5kW<br />

/ 3A<br />

600 mm<br />

1000 mm<br />

1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

Depth<br />

300 mm<br />

CPS 220/20<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A AIF CPS 220/20 LT 220V / 1,2A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M<br />

600 mm<br />

CPS 220 / 20 / 5,5kW<br />

/ 7,5A<br />

CPUS 220 / 64 / 11kW<br />

3~N/PE, 400V AC 1~N/PE, 230V AC 1~N/PE, 230V AC 1~N/PE, 230V AC 1~N/PE, 230V AC 1~N/PE, 230V AC<br />

10%, 50/60Hz 10%, 50/60Hz 10%, 50/60Hz 10%, 50/60Hz 10%, 50/60Hz 10%, 50/60Hz<br />

63 A 7 A 7 A 25 A 25 A 50 A<br />

100 A 7 A 7 A 25 A 25 A 50 A<br />

22 kW 1,5 kW 1,5 kW 5,5 kW 5,5 kW 11 kW<br />

- 18,1 Ah 27,8 Ah 27,8 Ah 75 Ah -<br />

max. 4 x 3A or 7,5A 1,2 A 3 A 3 A 7,5 A -<br />

16 5 5 5 5 16<br />

16 - - 16 16 16<br />

35 4 4 4 4 35<br />

35 35 35 35 35 35<br />

4 4 4 4 4 4<br />

4 - - - - 4<br />

4 4 4 4 4 4<br />

35 - - 4 4 35<br />

4 - - 2,5 2,5 4<br />

35 - - - - -<br />

35 - - - - -<br />

2000 x 800 x 400 1600 x 600 x 300 1800 x 600 x 300 1800 x 600 x 300 2030 x 600 x 400 830 x 800 x 400<br />

- BRS 10 BRS 10 BRS 10 BRS 10 BRS 08<br />

- 2460 x 1200 x 595 2460 x 1200 x 595 2460 x 1200 x 595 2460 x 1200 x 595 1374 x 624 x 334<br />

20 x M 20 10 x M 20 10 x M 20 10 x M 20 22 x M 20 22 x M 20<br />

50 x M 25 33 x M 25 33 x M 25 33 x M 25 64 x M 25 64 x M 25<br />

4 x M 40 4 x M 32 4 x M 32 4 x M 32 6 x M 32 6 x M 32<br />

2 x M 50 2 x M 50<br />

in option slot - - 1 Outgoing *2 1 Outgoing *2 in option slot<br />

1 Outgoing *2 - - 1 Outgoing *2 1 Outgoing *2 1 Outgoing *2<br />

1 x 27 TE *3 13 TE 13 TE 13 TE 24 TE 2 x 8 TE<br />

1 x 6 TE 1 x 4 TE<br />

2 TE - - - - -<br />

top or bottom top top top top top<br />

*1 not in option slot<br />

* in option slot<br />

*3 1 x 31 TE supply bottom side<br />

DC –<br />

3,15A<br />

AC ~<br />

00<br />

I<br />

DC – U<br />

AC ~<br />

3,15A<br />

Achtung!! Sicherungen im Gerät nicht unter Last ziehen.<br />

Anlage blockieren.<br />

10A<br />

10A<br />

Batteriesicherung<br />

hin ter d er B lende<br />

mm<br />

1000 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

16AT<br />

Ladeteil 220V/7,5A<br />

Depth<br />

300 mm<br />

CPS 220/20<br />

Achtung!! Sicherungen im Gerät nicht unter Last ziehen.<br />

Anlage blockieren.<br />

Batteriesicherung<br />

hinter d er B lende<br />

600 mm<br />

10A<br />

10A<br />

Ein<br />

10AT<br />

Batterie<br />

00 mm<br />

1000 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

16AT<br />

Ladeteil 220V/7,5A<br />

Depth<br />

300 mm<br />

CPS 220/20<br />

Achtung!! Sicherungen im Gerät nicht unter Last ziehen.<br />

Anlage blockieren.<br />

Batteriesicherung<br />

hinter d er B lende<br />

600 mm<br />

10A<br />

10A<br />

Ein<br />

10AT<br />

Batterie<br />

1000 mm<br />

1 00 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M<br />

Netz<br />

16AT<br />

Ladeteil 220V/7,5A<br />

CPS 220/20<br />

Achtung!! Sicherungen im Gerät nicht unter Last ziehen.<br />

Anlage blockieren.<br />

10A<br />

10A<br />

Batteriesicherung<br />

hinter d er B lende<br />

Depth<br />

400 mm<br />

00 mm<br />

Ein<br />

10AT<br />

Batterie<br />

00 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

CPS 220 / 64<br />

Depth<br />

400 mm<br />

00 mm


10<br />

Technical data: CPUSB 220 / 64 / 16 CPUSB 220 / 64 / 8-1 CPUSB 220 /<br />

64 / 24V<br />

Protection class: I<br />

Protection category: IP 0<br />

Perm. ambient temperature<br />

for system: -5°C bis +35°C<br />

for battery: see battery data sheet<br />

<strong>Battery</strong> voltage: 0V DC<br />

Housing color: RAL 7035<br />

Plinth (optional) 100mm or 00mm<br />

Rated voltage:<br />

600 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Depth<br />

300 mm<br />

600 mm<br />

CPUSB 220 / 64 / 8 - 9<br />

Powered by central battery system<br />

CPS 0/64/SV<br />

Technical data, systems overview<br />

CPUSB 220 /<br />

64 / 1 - 2A<br />

CPUSB 220 /<br />

64 / 1 - 4A<br />

<strong>System</strong> current: Intern - - 12 A 8 A 8 A<br />

total - - 12 A 8 A 8 A<br />

Circuit separating module - - - Yes Yes<br />

Circuit modules (4x2 A, 2x4 A, 1x6 A)<br />

Conductor cross section, max. (mm²):<br />

max. 16 max. 8 4 x 3 A 1 (je 2 A) 1 (je 4A)<br />

Outgoing to luminaires 4 4 4 4 4<br />

4V monitoring - - 2,5 4 4<br />

Supply cable 35 35 4 4 4<br />

BUS-line IB 4 4 2,5 4 4<br />

Dimensions H x W x D (mm) 600 x 600 x 300 600 x 600 x 300<br />

466 x 253 x<br />

116,5<br />

378 x 181 x 82 378 x 181 x 82<br />

With function preservation (option) BRS 08 BRS 08 BRS 08 BRS 06 BRS 06<br />

- with function preservation 1374 x 624 x 334 1374 x 624 x 334<br />

1374 x 624 x<br />

334<br />

1074 x 624 x<br />

334<br />

1074 x 624 x<br />

334<br />

Cable inlets 10 x M 20 10 x M 20 6 x M16 11 x M20 11 x M20<br />

33 x M 25 33 x M 25 9 x M 20<br />

4 x M 35 4 x M 35<br />

Space for options 4 TE 13 TE - - -<br />

Required space for options<br />

0 TE 1 TE TE 4 TE 6 TE 7 TE<br />

Mains terminals for substation<br />

(single-phase system)<br />

DPÜ DPÜ / B.1 LSA .1 LSA .1 4, incl.<br />

4 terminals<br />

Fuse protection <strong>Battery</strong><br />

NH00<br />

RIF 5 Fuse output NH00 for<br />

substation<br />

PSU 4<br />

600 mm<br />

600 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Fuse output Neozed for<br />

substation<br />

Mains terminals for substation<br />

(3-phase system)<br />

Depth<br />

300 mm<br />

600 mm<br />

CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A CP 4x2A<br />

1 1 1 1 1 1 1 1<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

2 2 2 2 2 2 2 2<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3 3 3 3 3 3 3 3<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

4 4 4 4 4 4 4 4<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

F<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

3,15 A<br />

= BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM = BL / NM<br />

= DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M = DL / M<br />

Depth<br />

300 mm<br />

600 mm<br />

116,5<br />

53<br />

466<br />

Depth<br />

82<br />

1 1<br />

37<br />

Depth<br />

82<br />

1 1<br />

37


CPS 0/64/SV<br />

Advantages and function of Joker-technology<br />

Joker-technology - a cost saving innovation<br />

� Each INOTEC CPS emergency lighting<br />

system can be built-up to three different<br />

supply luminaire switching modes on the<br />

same output at the same time. Luminaires<br />

with Joker high frequency electronic ballast<br />

(common standard on INOTEC-SV lumnaires)<br />

or Joker switch modules, for third party<br />

electronic ballast, must be used. These<br />

components allow an easy setting of the<br />

monitoring address and luminaire mode.<br />

� The patented JOKER-technology of INOTEC<br />

reduces the design- and installation time<br />

and cuts down on material cost.<br />

� The sample pictured shows the kind of<br />

installation savings which can be achieved.<br />

� Conventional systems and installations<br />

with the switching modes maintained-,<br />

non-maintained- and switched maintained<br />

mode, require 6 final end circuits to feed<br />

lumnaires in a part of the building shown.<br />

� The Joker-technology reduces the number<br />

of circuits required. Our sample needs only<br />

final end circuits to feed the same number of<br />

luminaires due to the fact that the operation<br />

of all switching modes on one circuit is<br />

possible.<br />

� The maintained and switched maintained<br />

luminaires are active during mains presence.<br />

During mains failure, however, all luminaires,<br />

regardless of their operation mode, will be<br />

switched on and supplied by the central<br />

battery system.<br />

German Patentnumber:<br />

DE 19807844<br />

European Patentnumber:<br />

EP 0939476<br />

Advantages of the Joker - technology<br />

� Simple design and engineering<br />

� Reduced installation material content<br />

� Cut down on installation time<br />

� Higher load level for final end circuits<br />

� Switching mode settable on each luminaire<br />

Conventional<br />

installation<br />

requires<br />

6 final end circuits<br />

Circuit 5<br />

Circuit 6<br />

Joker technology with<br />

2 final end circuits<br />

Circuit 1<br />

Circuit 3 Circuit4<br />

Circuit 2<br />

Circuit 1 Circuit 2<br />

Maintained Non-maintained Switched maintained<br />

11


1<br />

CPS-comfort TFT-controller<br />

� Graphic user interface<br />

� Administration of up to 1 circuits (max.<br />

.560 luminaires – 0 addresses per circuit)<br />

� Intuitive, single button operation<br />

� Detailed status- and failure display<br />

� Integrated network interface with webserver<br />

(InoWeb)<br />

� USB-interface<br />

� Load / store / change system-, circuit-,<br />

luminaire-confi guration<br />

� For standard printer (pcl-compatible) and<br />

keyboard<br />

� Free programmable, non-volatile memory<br />

� Password protection<br />

� Automatic time adjustment via network<br />

� Blocking function for complete system or<br />

mains lighting<br />

� Interface for BMS or other superior monitoring<br />

system<br />

� Helptext for all system functions<br />

� Various languages available<br />

Accessible display information:<br />

� All available status information for the complete<br />

CPS-system<br />

� Fault information for every circuit or individual<br />

luminaire with location text-info<br />

� Achieved battery duration (in minutes) during the<br />

last endurance test<br />

� Available battery capacity<br />

� Logbook entries > years<br />

Programming possibilities:<br />

� Single luminaire- / circuit monitoring<br />

� Automatic function test - / duration test cycles<br />

� Time delay on mains return<br />

� Deep discharge protection settings with display<br />

Optional:<br />

Standard 4-line liquid crystal display with functional<br />

limitations available.<br />

CPS 0/64/SV<br />

External supervision and display<br />

Circuit modules<br />

� Individual slide-in circuit modules with pole<br />

fuse-protection for every circuit<br />

� Single luminaire- and circuit- monitoring with<br />

JOKER function<br />

� Monitoring without data-line<br />

� LEDs in the front for circuit status info and circuit<br />

mode<br />

� Complete wired to terminals 4mm²<br />

� Available types:<br />

� 4 circuits á A (4x )<br />

� circuits á 4A ( x4)<br />

� 1 circuit á 6A (1x6)<br />

Charger 220 V/3,0 A and 220 V/7,5 A<br />

� For all available 16V lead-acid accumulators<br />

� Service-friendly 1 ‘‘ - housing<br />

� Modern, microprocessor controlled design with<br />

� high effi ciency<br />

� low weight<br />

� <strong>Battery</strong> charge- and discharge current information<br />

is permanently available at the CPS controller<br />

� Constant charger- and battery circuit monitoring<br />

with fault display at the CPS controller in case of<br />

� blown battery fuse<br />

� missing or defect battery block<br />

� faulty charger<br />

� open battery circuit<br />

� battery voltage to high / low<br />

�<br />

Temperature controlled charging to ensure<br />

longer battery life


CPS 0/64/SV<br />

<strong>System</strong> components and options<br />

Fully monitored, self suffi cient<br />

230V Bus-Substation<br />

The usage of this self suffi cient 30V bus-substation<br />

allows maximum fl exibility and gives a high<br />

safety standard in combination with cost saving<br />

for the installation.<br />

Local mains supply / lighting circuit monitoring<br />

and the standard INOTEC features like Joker-Technique<br />

give the design and planning all technical<br />

possibilities.<br />

<strong>Central</strong> programming, monitoring and detailed<br />

status-/failure- display of all connected bus-substations<br />

is achieved via the TFT-controller.<br />

Standard sizes:<br />

4x A and x4A for 30V AC / 0V DC<br />

Individual setting of monitoring-/operation-mode<br />

for every circuit<br />

� Single luminaire monitoring<br />

� Circuit monitoring<br />

� Non-maintained mode<br />

� Maintained mode<br />

� Switched maintained mode<br />

� Joker Technique<br />

� Modular, allowing fl exibility for special<br />

applications<br />

�<br />

<strong>Central</strong> programming via TFT-controller of main<br />

panel<br />

Monitoring loop for local mains failure detection<br />

LEDs for local status information on circuit mode<br />

and failures<br />

Fully monitored, self suffi cient<br />

24V Bus-Substation<br />

The 4V bus-substation, connected to a CPS<br />

0/64 SV system, operates fully self suffi cient but<br />

is fully monitored via the main emergency lighting<br />

panel. In addition to the information available<br />

on the TFT of the main panel all local status- and<br />

luminaire information is available on the LCD of<br />

the substation.<br />

The station offers the following standard features<br />

along with the proven Joker-Technique:<br />

� Supply of 4V INOTEC LED luminaires<br />

� 4 output circuits in protection class III (SELV) for<br />

0 luminaires / each output<br />

� Controller with 4 x 0 characters; individual luminaire<br />

text info<br />

� Various languages settable<br />

� Automatic function monitoring of all connected<br />

circuits and luminaires without additional<br />

data-line<br />

� individual dimmlevels settable for each individual<br />

luminaire on the substation controller<br />

� Automatic / manual luminaire addressing via<br />

substation controller<br />

� Statusinfo for system and luminaires via display<br />

and LEDs<br />

� Voltfree contacts for external status display<br />

� Switch contact for remote blocking facility<br />

� LSA 4 built in for individual luminaire switching<br />

� Monitoring loop for local mains failure detection<br />

� <strong>Central</strong> dimming possibility for individual<br />

luminaires or complete circuit via internal pushbutton<br />

or external 0-10V interface<br />

13


14<br />

Relay contacts<br />

4V DC<br />

max.100mA<br />

single phase<br />

supply monitor<br />

battery voltage<br />

RIF 5<br />

Interface for remote status indication and system<br />

blocking function.<br />

Free programmable, in connection to a switch, for<br />

� maintained and non maintained emergency light<br />

ON/OFF<br />

� maintained emergency light ON/OFF<br />

With or without loop monitoring<br />

5 voltfree contacts for<br />

� operation<br />

� battery operation<br />

� failure (general)<br />

� free programmable<br />

Terminals battery sensor for temperature controlled<br />

charging<br />

With phase monitor (sub-db or main-db), single<br />

phase<br />

Contacts: 4V / 1A<br />

EMC protected to EN 55015<br />

Dimension: H = 5 , W = 71.5, D = 0 (mm)<br />

<strong>System</strong> status<br />

Operation Sum- <strong>Battery</strong><br />

failure operation<br />

Failure 1- close open close<br />

Operation 3-4 close open open<br />

<strong>Battery</strong> open open close<br />

operation 5-6<br />

Option 1 selectable<br />

Option selectable<br />

Volt free contacts<br />

internal wiring<br />

Remote switch<br />

850 009<br />

4V<br />

Monitoring loop<br />

Temp. sensor<br />

MTB<br />

CPS 0/64/SV<br />

External supervision and display<br />

The MTB-remote mimic panel (MTB/AP = wall<br />

mounting, MTB/UP = recessed wall-/panel mounting)<br />

are used for external status- and failure indication<br />

of emergency lighting systems. Furthermore<br />

it allows to block the system via the integrated<br />

key-switch.<br />

Functions:<br />

Key-switch free programmable for:<br />

� maintained and non maintained light ON / OFF<br />

� maintained light ON / OFF<br />

Displayed:<br />

� Green LED - operation<br />

� Yellow LED - battery operation<br />

� Red LED - failure (battery / luminaire)<br />

Connection to RIF-module of CPS-system; max<br />

cable length with 0, mm² 500m<br />

Voltage: UN= 4V DC +/-10%<br />

Mode: Permanent operation<br />

Temp.-range: -15°C ... +40°C<br />

Protection: IP 0 MTB/UP; IP 54 MTB/AP<br />

Housing: Stainless steel/polycarbonate MTB/UP<br />

Thermoplast MTB/AP<br />

EMC protection to EN 55015<br />

Wall mounting:<br />

00<br />

Recessed wall mounting:<br />

0<br />

Notlicht<br />

Betrieb<br />

Störung Batt.-Betrieb<br />

Ein<br />

INOTEC<br />

Aus<br />

5<br />

74<br />

105<br />

70<br />

115<br />

165 101


CPS 0/64/SV<br />

<strong>System</strong> components and options<br />

LSA 3.1<br />

Light switch monitor, 3 channels<br />

For the common switching (on/off ) of safety luminaires<br />

along with the mains lighting<br />

Up to three channels can be allocated to every<br />

individual, or a number of CPS output circuits. This<br />

switch/channel allocation happens during the<br />

set-up/commissioning and is programmable on the<br />

CPS-controller.<br />

Attention: common neutral!<br />

Supply voltage: 30V AC 50/60 Hz<br />

EMC protected to EN 55015<br />

Dimensions: H = 5 , W = 17,5, D = 0(mm)<br />

PE<br />

N<br />

L<br />

General lighting<br />

PE<br />

N<br />

L<br />

General lighting<br />

Internal wiring<br />

PE<br />

N<br />

L<br />

850 008<br />

LSA 8.1 mit DPÜ/BUS<br />

Light switch monitor, 8 channels<br />

For the common switching (on/off ) of safety luminaires<br />

along with the mains lighting and for phase<br />

monitoring.<br />

Each channel is galvanic separated.<br />

Up to three channels can be allocated to every<br />

individual, or a number of CPS output circuits. This<br />

switch/channel allocation happens during the setup/<br />

commissioning and is programmable on the<br />

CPS controller.<br />

Three-phase-monitor, DPÜ/BUS<br />

� free selectable phase connections<br />

� 1 change-over contact<br />

� monitoring low voltage and mains failure<br />

� for single-phase monitoring too<br />

� voltage 30V AC, 400V AC<br />

� threshold 0, 5 x UN<br />

� deactivation switch<br />

Failure info at the CPS-controller with location<br />

Supply voltage:<br />

Available in 30V AC 50/60 Hz or 4V DC<br />

EMC protected to EN 55015<br />

Dimension: H = 5 , W = 71,5, D = 0(mm)<br />

PE<br />

N<br />

L<br />

General lighting<br />

15


16<br />

DPÜ<br />

Three Phase Monitor<br />

To detect phase- or circuit failures in general lighting<br />

sub-distribution panels<br />

With volt-free failure indication contact<br />

� LED-indication for L1, L , L3<br />

� free selectable phase connections<br />

� monitoring low voltage and mains failure in threephase<br />

networks<br />

� for single-phase monitoring too<br />

� acc. to IEC 55<br />

� for DIN rail mounting<br />

For the connection to INOTEC central- and group<br />

supply battery systems.<br />

Voltage: 30V/400V AC 50/60 Hz<br />

Threshold: 0, 5 UN<br />

Perm. temp.: - 0°C ... +60°C<br />

EMC protected to 55015<br />

Dimension: H =5 , W = 17,5, D = 0(mm)<br />

SL -<br />

L1<br />

L2<br />

L3<br />

N<br />

PE<br />

+24V<br />

BUS<br />

2T<br />

N L1 L2 L3<br />

Adresse<br />

L1 L2 L3 1 bis 31<br />

DPÜ / B.1<br />

890 414<br />

INOTEC<br />

5<br />

Kontakte (1 / 2) + (3 / 4) 5<br />

öffnen bei Netzausfall<br />

gem. VDE 0108<br />

ta: -15 bis 40°C<br />

EMC: gem. EN 55015<br />

1 +24V BUS<br />

3 4<br />

From CPS 0 / 64<br />

DB 1 DB DB ...<br />

3<br />

2<br />

3<br />

2<br />

4<br />

1<br />

4<br />

1<br />

0<br />

0<br />

6<br />

9<br />

6<br />

9<br />

7<br />

8<br />

7<br />

8<br />

T<br />

Einer<br />

Zehner<br />

L1<br />

L2<br />

L3<br />

N<br />

PE<br />

CPS 0/64/SV<br />

<strong>System</strong> components and options<br />

DPÜ/B.1<br />

Three Phase Monitor with BUS, addressable<br />

To detect phase- or circuit failures in general lighting<br />

sub-distribution panels. With location info at<br />

CPS-controller of monitored sub-distribution panel<br />

in case of phase failure.<br />

With volt-free failure indication contact.<br />

� LED-indication for L1, L , L3<br />

� free selectable phase connections<br />

� x n/o contacts<br />

� monitoring low voltage and mains failure in three<br />

-phase networks<br />

� for single-phase monitoring too acc. to IEC 55<br />

� for DIN rail mounting<br />

� Detailed phase failure with location info of the<br />

sub-db at CPS controller<br />

For the connection to INOTEC central- and<br />

group supply battery systems.<br />

Voltage: 30V/400V AC 50/60 Hz<br />

Threshold: 0, 5 UN<br />

Perm. temp.: -15°C ... +40°C<br />

EMC protected to 55015<br />

Dimension: H = 5 , W = 36, D = 0(mm)<br />

2T<br />

N L1 L2 L3<br />

Adresse<br />

L1 L2 L3 1 bis 31<br />

DPÜ / B.1<br />

890 414<br />

INOTEC<br />

5<br />

Kontakte (1 / 2) + (3 / 4) 5<br />

öffnen bei Netzausfall<br />

gem. VDE 0108<br />

ta: -15 bis 40°C<br />

EMC: gem. EN 55015<br />

1 +24V BUS<br />

3 4<br />

Address setting is mandatory<br />

for full functionality<br />

3<br />

2<br />

3<br />

2<br />

4<br />

1<br />

4<br />

1<br />

0<br />

0<br />

6<br />

9<br />

6<br />

9<br />

7<br />

8<br />

7<br />

8<br />

T<br />

Einer<br />

Zehner<br />

L1<br />

L2<br />

L3<br />

N<br />

PE<br />

2T<br />

N L1 L2 L3<br />

Adresse<br />

L1 L2 L3 1 bis 31<br />

DPÜ / B.1<br />

890 414<br />

INOTEC<br />

5<br />

Kontakte (1 / 2) + (3 / 4) 5<br />

öffnen bei Netzausfall<br />

gem. VDE 0108<br />

ta: -15 bis 40°C<br />

EMC: gem. EN 55015<br />

1 +24V BUS<br />

3 4<br />

3<br />

2<br />

3<br />

2<br />

4<br />

1<br />

4<br />

1<br />

0<br />

0<br />

6<br />

9<br />

6<br />

9<br />

7<br />

8<br />

7<br />

8<br />

T<br />

Einer<br />

Zehner<br />

Wire link on<br />

last DPÜ/B.1<br />

mandatory


CPS 0/64/SV<br />

Luminaire monitoring and supply modules<br />

J-SV-Modul/S<br />

J-SV-Modul.2/S<br />

J-SV-Modul.3/S<br />

J-SV-Modul.4/S<br />

J-SV-Modul.L/S<br />

Single luminaire monitoring module<br />

for fl uorescent- (T16/T5…) compact fl uorescent,<br />

halogen and incandescent lamps. With easy accessible<br />

address switch, JOKER function and individual<br />

lamp monitoring. This module features a sense-input<br />

or an inverted phase monitor too.<br />

The JOKER/S function allows luminaires to be<br />

operated via these J-SV-modules in maintained,<br />

non-maintained and switched mode on the same<br />

fi nal end circuit.<br />

Suitable for emergency lighting systems to EN<br />

50171 / EN 5017 .<br />

Designed to be installed inside of luminaires. For<br />

the connection to INOTEC low power- or central<br />

power battery systems.<br />

Voltage: 30 V AC, 50/60 Hz<br />

0 V DC, ± 0 %<br />

Perm. temp.: -15°C ... +50°C<br />

EMC protected to EN 55015<br />

Input<br />

PE<br />

N<br />

L<br />

From CPS 0<br />

Light switch<br />

N- J-SV-Modul/S LS<br />

N-<br />

NS<br />

J-SV-Modul. /S<br />

L+ J-SV-Modul.3/S N-<br />

L+ J-SV-Modul.4/S L+<br />

NS<br />

LS<br />

N-<br />

L+<br />

J-SV-Modul.L/S<br />

General lighting<br />

Fluorescent lamps with<br />

high frequency electronic ballast<br />

standard bulbs or halogen lamps<br />

N-<br />

L+<br />

N-<br />

N-<br />

L+<br />

L+<br />

LS<br />

NS<br />

1<br />

J-EVG4-6/SV-S 2<br />

J-EVG 4-13/SV-S 3<br />

J-EVG 1 /SV-S 4<br />

Fluorescent lamps with<br />

high frequency<br />

electronic ballast<br />

standard bulbs<br />

or halogen<br />

lamps<br />

Out<br />

17


1<br />

<strong>Battery</strong> current for lamps used for emergency<br />

/ safety lights<br />

Table 1<br />

Data for INOTEC high frequency ballasts during<br />

mains- and battery operation.<br />

Lamp Base INOTEC EVG Lamp I Bat. Mains<br />

type [mA] load [VA]<br />

T 16 G5 4-6W / 4-13W 4W 0 4,<br />

4-6W / 4-13W 6W 5 6,3<br />

4-13W W 33 ,4<br />

4-13W 13W 44 14<br />

TC-SEL G7 4-13W 5W 4 5,3<br />

4-13W 7W 6 7,4<br />

4-13W W 33 10<br />

4-13W 11W 44 1<br />

TC-DEL G 4 q1 4-13W 10W 35 11<br />

4-13W 13W 44 14<br />

G 4 q 1 W 1 W 0 1<br />

TC-TEL GX 4 q1 13W 13W 44 14<br />

GX 4 q 1 W 1 W 0 1<br />

T 6 G 13 1 W 1 W 0 1<br />

36W 36W 100 / 150 37<br />

(50% / 100% Light output)<br />

5 W 5 W 140 / 35 60<br />

(50% / 100% Light output)<br />

TC-F G 10 1 W 1 W 0 1<br />

TC-L G 11 1 W 1 W 0 1<br />

Qty. LED<br />

24V<br />

IBat. [mA]<br />

6x0,5W 1 5<br />

4x0,5W 100<br />

4x1W 00<br />

3x1W 150<br />

x1W 1 5<br />

1x W 150<br />

CPS 0/64/SV<br />

<strong>System</strong> design and tables<br />

Table 2<br />

Data for INOTEC LED luminaire with<br />

Power LED. (J-ET / 4 ... SV) For specific luminaire<br />

details see luminaire catalogues.<br />

Qty. LED<br />

230V<br />

DC-load IBat. [mA]<br />

Mainload<br />

[VA]<br />

1 3,1W 1 4,<br />

4, W 17 ,3<br />

3 5,3W 4 ,<br />

4 6,4W 11,1<br />

5 7,6W 37 13,<br />

6 7,7W 4 14,0<br />

Table 3<br />

Data for glow wire lamps (AGL) and halogen<br />

lamps with electronic transformer.<br />

0V Glow<br />

wire lamp<br />

I<br />

Bat.<br />

[mA]<br />

Halogen<br />

lamp<br />

I<br />

Bat.<br />

[mA]<br />

7 W 30 0 W 115<br />

15 W 70 35 W 10<br />

5 W 110 50 W 5<br />

40 W 1 0 75 W 4 0<br />

60 W 70 100 W 560<br />

75 W 340<br />

100 W 450


CPS 0/64/SV<br />

<strong>System</strong> design and tables<br />

Table 4<br />

<strong>Battery</strong> data<br />

Capacity Weight [kg] Housing Max. discharge current [A]<br />

5,0<br />

,0<br />

1 ,0<br />

1 ,1<br />

,7<br />

33,0<br />

45,4<br />

50,<br />

6 ,<br />

74,0<br />

75,3<br />

Block<br />

,5<br />

3,6<br />

5,6<br />

5,<br />

10,0<br />

11,<br />

14,<br />

1 ,<br />

6,1<br />

31,3<br />

4,1<br />

Total<br />

45,0<br />

64,<br />

100,<br />

106,<br />

1 0,0<br />

1 ,4<br />

6 ,<br />

3 7,6<br />

46 ,<br />

563,4<br />

433,<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

1*1<br />

h<br />

0,7<br />

1,0<br />

1,3<br />

,0<br />

3,4<br />

4,0<br />

5,3<br />

6,<br />

,4<br />

,<br />

,7<br />

3h<br />

1,5<br />

,1<br />

,<br />

4,<br />

,3<br />

,<br />

1 ,0<br />

14,5<br />

1 ,6<br />

0,3<br />

1 ,<br />

h<br />

,1<br />

,<br />

3,7<br />

7,6<br />

11,4<br />

1 ,6<br />

16,3<br />

0,<br />

7,0<br />

,5<br />

6,3<br />

1h<br />

3,<br />

4,5<br />

6,<br />

11,0<br />

0,<br />

,<br />

,<br />

35,<br />

46,5<br />

51,0<br />

47,5<br />

1,4 6,4 475, * ,6 1,6 , 55,1<br />

1, 30,1 541, * 10, 4,1 33,0 60,3<br />

1,0 37, 66 ,6 * 11,1 5,3 35,7 64,0<br />

10 ,1 33,1 5 5, * 1 , ,6 3 , 6 ,<br />

134,0 4 ,5 765,0 * 15, 35, 45, 7 ,0<br />

153,6 47,0 46,0 1 , 41,4 56,5 10 ,<br />

05, 67, 1 0 ,6 4,7 5 , 7 , 143,<br />

*1 <strong>Battery</strong> housing included in CPS assembly<br />

* 1 <strong>Battery</strong> housing included in CPS assembly<br />

Table 5<br />

Chargers and ventilation<br />

Recharging 1 hours / 0%<br />

Capacity Qty. charger Free airflow Ventilation<br />

C 10 -1, V/Z 3,0A 7,5A [m³/h] [cm²]<br />

5,0 1 0,03 0, 0<br />

,0 1 0,04 1, 0<br />

1 ,0 1 0,06 1,70<br />

1 ,1 1 0,10 , 0<br />

,7 1 0,15 4, 0<br />

33,0 1 0,1 5,10<br />

45,4 1 0, 5 7,00<br />

50, 1 0, 7 7,60<br />

6 , 1 0,37 10,40<br />

74,0 1 0,40 11, 0<br />

75,3 1 0,41 11,50<br />

1,4 1 0,44 1 ,40<br />

1, 1 0,50 14,00<br />

1,0 1 0,4 13, 0<br />

10 ,1 1 0,55 15,40<br />

134,0 1 1 0,7 0, 0<br />

153,6 1 1 0, 3 3,30<br />

05, 1,11 31,10<br />

Table 6<br />

Fuse protection mains supply<br />

Over all connection power to kVA - 11 kVA 11 - 14 kVA 14 - 1 kVA 1 - kVA<br />

Fuse protection 35A 50A 63A 0A 100A<br />

Min. conductur cross-section 6mm² 10mm² 16mm² 5mm² 35mm²<br />

The specification are min. conductur cross-sections. For the max. permissible line drop the dimensioning<br />

of the conductor is to be made according to the distance and the connection power. (max.<br />

line drop: 3%)<br />

1


0<br />

INOTEC Sicherheitstechnik GmbH<br />

Am Buschgarten 17<br />

D - 5 46 Ense<br />

Tel +4 3 / 7 30-0<br />

Fax +4 3 / 7 30-<br />

info@inotec-licht.de<br />

www.inotec-licht.de<br />

Sicherheitstechnik GmbH<br />

707 075 0 / 00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!