3. Brooding<br />

3.1. Ventilation<br />

●<br />

●<br />

●<br />

Minimum ventilation controls air quality via fans which<br />

must work on a timer and inlets controlled by pressure and<br />

both independent of temperature control. The minimum<br />

ventilation system operates any time the house temperature<br />

is at or below the house set point temperature.<br />

The timer should provide a minimum air exchange value of<br />

12.5% (1/8) of house volume. The minimum run time needs<br />

to be at least 60 seconds to ensure that the incoming cold,<br />

outside air has properly mixed and heated with the internal<br />

air before reaching chick level.<br />

Inlets are vital in achieving good air volume and uniform air<br />

distribution.<br />

●<br />

The inlets should completely seal when closed.<br />

●<br />

●<br />

●<br />

The inlets should react to the fans and work on pressure,<br />

NOT on percentage of opening or temperature.<br />

The inlet capacity should match the fan capacity at the<br />

fans working pressure based on the width of the house.<br />

Automatic calculation of minimum ventilation requirements for your house can be made on our website<br />

www.cobb-vantress.com