„<strong>UMTS</strong> <strong>Signaling</strong>“ – Abstract – Wiley & Sons, 2005 – ISBN 0-470-01351-6<br />

|**b136** |1.1.2 nas-Message |c4 40 01 69 10 80 e7 19 00 44 52... |<br />

|TS 24.008 Call Control V3.8.0 (CC-DMTAP) SETUP (= Setup) |<br />

|Setup |<br />

|----0011 |Protocol Discriminator |call control, call related SS messag|<br />

|-000---- |Transaction Id value (TIO) |TI value 0 |<br />

|CaLleD party BCD number |<br />

|01011110 |IE Name |CaLleD party BCD number |<br />

|00000111 |IE Length |7 |<br />

|----0000 |Number plan |Unknown |<br />

|-000---- |Type of number |Unknown |<br />

|1------- |Extension bit |No Extension |<br />

|**b44*** |Called party number |`0800123456` |<br />

|1111---- |Filler |15 |<br />

|Stream Identifier |<br />

|00101101 |IE Name |Stream Identifier |<br />

|00000001 |IE Length |1 |<br />

|00000001 |Stream Identifier |1 |<br />

----------------------------------------------------------------------------------------------<br />

Message Example 1-2: Call Control SETUP (MOC)<br />

In the message example it is further shown on which channels the message is transported. Physical<br />

transport bearer on Iub interface is an AAL2 SVC with VPI/VCI/CID = 10/26/183. On this physical<br />

transport bearer a dedicated (transport) channel (DCH) is running and because SETUP is a NAS<br />

signaling message it is carried by a logical DCCH with logical channel ID = 3, which is identical with<br />

signaling radio bearer ID = 3 (NAS signaling with high priority). The CN-DomainIdentity of RRC Uplink<br />

Direct Transfer message indicates that the message will be forwarded to CS core network domain<br />

represented by MSC (Rel. 99) or MSC Server (Rel. 4 and higher). Since type of number and number<br />

plan of called party number are unknown it is sure that the called party number string contains all<br />

digits as they have been dialed by subscriber.<br />

Reception of SETUP is answered by core network with<br />

DownlinkDirectTransfer CPROC – This message indicates that the call is being processed by core<br />

network entities. On UE side the call control state is changed when this message is received. With<br />

entering the new state it becomes impossible to send any additional dialing information.<br />

Now Radio Resources for dedicated traffic channels (DTCHs) need to be provided by (C)RNC. A<br />

dedicated physical channel in uplink and downlink direction already exists and it is identified by UL<br />

scrambling code number and DL channelisation code number. Hence, this channel needs to be<br />

reconfigured, because more data traffic between UE and network is expected when DTCHs are<br />

mapped on this physical channel. The higher the data transfer rate on radio interface is the lower must<br />

be the chosen spreading factor assigned with channelisation code. So a new downlink channelisation<br />

code with lower spreading factor than before is found in the Synchronized Radio Link Reconfiguration<br />

Preparation message as well as a new minimum uplink channelisation code length (minULChCdLen),<br />

which value is also smaller than in Radio Link Setup message before (λ