10.2 Dining Room<br />
During our PCA, we found that there were structural walls removed to give the main floor an open concept feel.<br />
On the ceilings where the old walls were located, there are cracks in the drywall. With no permits obtained for this<br />
structural modification, it is obvious that something is not correct. We have been informed that these cracks have<br />
been repaired 2 times already and they are still coming back.<br />
Also to note, the walls and ceiling were only primed and did not have any paint on them.<br />
Recommendations: We advise that the ceilings be opened up and the engineered beam be inspected to make sure<br />
the work was completed correctly.<br />
We also suggest that the concrete base of the support posts holding up these beams be x-rayed to determine that<br />
the thickness of the concrete slab is sufficient to support the weight of the posts and beams.<br />
After all of the inspections have been made, we suggest that the smooth finish drywall ceilings be repaired and all of<br />
the walls and ceiling be primed and painted.<br />
10.3 Kitchen<br />
During our PCA and onsite interview, we found that the kitchen walls and ceiling are only lightly primed and not<br />
painted.<br />
On inspection of the new kitchen cabinets, we noticed that they are not installed flush and level. Because of the<br />
rustic finished look of the cabinets, this is not very noticeable.<br />
In order to fit a larger refrigerator, the exterior wall was sectioned out and moved back. It is unclear that this work<br />
done to a loadbearing wall was in fact performed correctly due to the fact that no permits were pulled for this<br />
project.<br />
The kitchen electrical also has issues. See section 7.2 Kitchen Electrical for details.<br />
Recommendations: We advise that the new exterior build-out be opened up on the inside of the house to properly<br />
inspect and make sure the work was completed correctly.<br />
We also recommend that the walls and ceilings be painted 10.4 Small TV Area – Off Kitchen.<br />
During our PCA, and under visual inspection only, we noticed that there was cracks in the walls as well as poorly<br />
finished drywall. All of the walls and ceilings were only lightly primed and not painted.<br />
Recommendations: We advise that the drywall be repaired and completed to a smooth wall finish. Also that the<br />
walls and ceiling be primed and painted.<br />
10.4 Utility Rooms/Areas<br />
Laundry Room: During our PCA, we noticed that there are no baseboards on the walls in the laundry room.<br />
We also noticed that the laundry room dryer vent is plumbed into the mudroom and then out to the exterior of the<br />
house. As it sits, the exterior vent is too close to the ground.<br />
Recommendations: We advise that new baseboards are installed to match the rest of the home.<br />
Also, we recommend that the dryer duct and exterior vent be relocated to a higher position.<br />