VH 2 <strong>Milling</strong> spindle performance diagrams Dimensions<br />

n [min-1 Permanent greasing Torque Md Power P<br />

Md [Nm] P [kW]<br />

200<br />

70<br />

60<br />

150<br />

100<br />

40 kW<br />

50<br />

40<br />

30<br />

48<br />

48 Nm<br />

20<br />

10<br />

0<br />

0<br />

0 8000 15000 20000 25000 30000 35000<br />

]<br />

n [min-1 Oil-air lubrication Torque Md Power P<br />

Md [Nm] P [kW]<br />

200<br />

70<br />

60<br />

150<br />

100<br />

40 kW<br />

50<br />

40<br />

30<br />

48<br />

48 Nm<br />

20<br />

10<br />

0<br />

0<br />

0 8000 15000 20000 25000 30000 35000<br />

]<br />

X-axis approx. 3 000 – 6 000 mm<br />

Y-axis approx. 2 360 – 3 360 mm<br />

Worktable length 4 500 – 8 000 mm<br />

Worktable width<br />

2 000 – 3 000 mm<br />

Length approx. ca. 5 466 – 9 966 mm<br />

All dimensions shown are examples of the FZ 32 in the minimum<br />

and maximum configurations. Special variations within this<br />

range are also possible.<br />

Options 5 axes 3+1 axes 3 axes<br />

Water cooling rotary axes ■<br />

Safety guarding ■ ■ ■<br />

Control cabinet air-conditioning ■ ■<br />

Permanent grease with automatic greasing system ■<br />

A-axis: adjustable position axis ■<br />

Coolant system ■ ■ ■<br />

Minimum quantity lubrication ■ ■ ■<br />

12-, 18- or 20-tool toolchanger ■ ■ ■<br />

Measuring touch probe ■ ■ ■<br />

Tool measurement ■ ■ ■<br />

Chip conveyor ■ ■ ■<br />

Special painting ■ ■ ■<br />

A- and C-axis clamping ■<br />

Subject to technical changes.<br />

Height approx. 3 650 – 5 235 mm<br />

Z-axis 1 000 – 1 500 mm<br />

Width 3 420 – 4 420 mm<br />

■ Standard<br />

■ Option<br />