■ EVA Audio-Management System, certified to EN54<br />

■ EVA 8 EN Audio-Management<br />

EVA 8 EN is an innovative compact public address <strong>and</strong><br />

voice alarm system. EVA 8 EN manages the signal <strong>and</strong><br />

message diffusion <strong>and</strong> monitors the emergency<br />

microphones, the stored emergency <strong>and</strong> evacuation<br />

announcements, also the connected amplifiers included<br />

spare amplifier, also all the relevant security signal<br />

paths <strong>and</strong> communicates with possibly installed UPS<br />

units to control by switching off or over not required<br />

components. Furthermore, EVA 8 EN permanently<br />

&&<br />

monitors the connected loudspeaker lines for inter-<br />

GRÄF MEYER<br />

Kurzübersicht<br />

Einstellmöglichkeiten ■ 1 audio input with für separate Volumen/Treble/Bass level control for separat any für<br />

jeden NF-Ausgang.<br />

AF output<br />

■<br />

Überwachung Up to 8 loudspeaker-lines eines angeschlossenen (4 a/b), continuously 100V-Havarieverstärkers;<br />

monitoring Ansteuerung for disconnection, des Havarieverstärkers impedance variation, über<br />

trafosymmetrischen short circuits <strong>and</strong> NF-Ausgang. ground failures.<br />

■ 1 additional audio input (AUX) with separate level<br />

Überwachung von bis zu 4 Lautsprecherlinien, jeweils<br />

control, dem<strong>and</strong> over contacts, (switching to ground),<br />

unterteilt in Kreis A und B (insgesamt 8 Prüfkreise). Über-<br />

for any AF output (e.g. commercial).<br />

wachung jedes angeschlossenen Prüfkreises auf Unter-<br />

■ brechung, 4 balanced Impedanzabweichung, AF outputs (plus one Kurz- for the und spare Erdschluss. amplifier)<br />

Abtrennen – each with entsprechender volume, treble Lautsprecherkreise <strong>and</strong> bass control – to control bei<br />

festgestelltem the power Kurzschluss.<br />

amplifier<br />

■ 4 AF-outputs, which are supplied simultaneously, each<br />

Anschluss von 2 Feuerwehr-System-Sprechstellen (EVA 8<br />

with different audio sources.<br />

SYS FT) an der Geräterück- oder auch als H<strong>and</strong>mikrofon<br />

direkt an der Frontseite (EVA 8 SYS FH). Mikrofonkapseln<br />

sowie Anforderungsleitungen werden auf Bruch und<br />

ruptions, impedance deviations, short circuits <strong>and</strong><br />

ground faults. EVA 8 EN has been developed from a<br />

practical point of view for the needs <strong>and</strong> an easy use in<br />

public buildings, where a lot of people may have to be<br />

evacuated, such as shopping centers, administrative<br />

buildings, industrial facilities, railway stations, airports,<br />

schools <strong>and</strong> hotels.<br />

Monitored interface for connection to <strong>NSC</strong>-Fire Control<br />

Panels.<br />

EVA 8 Audio-Management nach DIN EN 60849 (VDE 0828)<br />

Überwachung von angeschlossenen 100V-Endver- Wahlfreie Zuteilung des Musikprogrammes zu jedem NFstärkern;<br />

Ansteuerung der Endverstärker über 4 trafo-<br />

EVA 8 EN system can be managed the following Ausgang; modules separate Pegeleinstellung or systems:<br />

für jeden Matrixsymmetrische<br />

NF-Ausgänge.<br />

Knoten.<br />

■ Zuspielung 2 monitored von fire 2 microphones Texten (z. B. according Räumungstexte) to DIN EN 60849 selektiv<br />

über (VDE0828) potentialfreie Anforderungskontakte (Melder),<br />

■ wahlfreie Unlimited Zuordnung number of und call jeweils stations separate of the type Pegeleinstellung<br />

S01230-00 /<br />

für S01240-00. jeden NF-Ausgang.<br />

■ 1 4 über monitored externen request Kontakt contact abrufbaren, lines for überwachten evacuation Text mit<br />

wahlfreier announcements Zuordnung und separater Pegeleinstellung für<br />

jeden ■ 1 additional<br />

NF-Ausgang<br />

text space<br />

(z.<br />

for<br />

B. Ladenschluss<br />

common information<br />

per Uhrenkontakt<br />

that can<br />

oder be started Gongeinspielung).<br />

from a contact (switching to ground)<br />

■ Textmeldungen Texts are stored on werden SD / MMC auf card MMC-Flash- in .mp3 size; the oder player SD-<br />

Speicher-karten module <strong>and</strong> signal im paths MP3-Format are continuously abgelegt; monitored. Playermodul<br />

und Signalpfade permanent überwacht.<br />

Einfache CE-Certificate: Programmierung 1438-CPD-0235 direkt an der Zentraleinheit über<br />

Taster und Display; Schnittstelle für PC-Anbindung<br />

vorh<strong>and</strong>en, PC für die Inbetriebnahme nicht erforderlich.