Company Profile<br />
Limmer Laser GmbH is a German company, specialis<strong>in</strong>g <strong>in</strong> the design,<br />
manufacture <strong>and</strong> sale of medical lasers <strong>and</strong> accessories. Our products<br />
cover all the major discipl<strong>in</strong>es of human, dental <strong>and</strong> veter<strong>in</strong>ary medic<strong>in</strong>e.<br />
For each discipl<strong>in</strong>e a broad range of high quality accessories is available,<br />
such as the VACULAS smoke evacua<strong>to</strong>r. The product range <strong>in</strong>cludes CO2<br />
Lasers, Diode Lasers <strong>and</strong> Specialty Lasers.<br />
Instead of simply focus<strong>in</strong>g on separate devices, our philosophy is <strong>to</strong> create<br />
multipurpose, <strong>in</strong>tegrated <strong>and</strong> highly functional work stations. Work<strong>in</strong>g<br />
with our many loyal cus<strong>to</strong>mers all over the world, <strong>and</strong> our established<br />
network of suppliers <strong>and</strong> distribu<strong>to</strong>rs, we will cont<strong>in</strong>ue <strong>to</strong> provide<br />
<strong>in</strong>novative solutions for modern medic<strong>in</strong>e far <strong>in</strong><strong>to</strong> the future.<br />
We have a strong emphasis on research <strong>and</strong> development, production,<br />
service <strong>and</strong> tra<strong>in</strong><strong>in</strong>g. Work<strong>in</strong>g <strong>in</strong> conjunction with hospitals <strong>and</strong><br />
physicians is just as important as good communication. Product quality is<br />
our No. 1 priority: Our company is certified <strong>to</strong> the str<strong>in</strong>gent European<br />
Quality St<strong>and</strong>ard EN ISO 13485:2003.<br />
Limmer Laser GmbH<br />
Schwarzschildstr. 1 • D-12489 Berl<strong>in</strong> • Germany<br />
Tel. +49 (0)30 - 6392 5570 • Fax +49 (0)30 - 6392 5580<br />
<strong>in</strong>fo@limmerlaser. de • www.limmerlaser.de<br />
1110.1<br />
Lithotripsy Laser<br />
FREDDY<br />
400 plus<br />
LFD Volume
FREDDY 400 plus<br />
Speed - <strong>Safe</strong>ty - S<strong>to</strong>nefree<br />
The FREDDY 400 plus lithotripsy laser is the new<br />
st<strong>and</strong>ard for effective, safe <strong>and</strong> fast s<strong>to</strong>ne<br />
therapy. Us<strong>in</strong>g specialised, state of the art<br />
technology, this device guarantees<br />
tissue-protective treatment of even the hardest bladder, kidney or bile duct s<strong>to</strong>nes, <strong>in</strong> a faster <strong>and</strong><br />
more cost-effective way than any other s<strong>to</strong>ne therapy currently available.<br />
<strong>Highly</strong> flexible fibre probes allow <strong>in</strong>tracorporeal<br />
lithotripsy <strong>in</strong> bladder, ureter <strong>and</strong> kidney<br />
The <strong>in</strong>novative Antiperforation Mode<br />
avoids the coagulation or perforation of<br />
surround<strong>in</strong>g tissue. In contrast <strong>to</strong> traditional<br />
laser lithotripters, for example based on Ho:YAG<br />
lasers, FREDDY 400 plus only affects solid material.<br />
This extraord<strong>in</strong>ary safety feature results <strong>in</strong> shorter<br />
treatment <strong>and</strong> recovery times for the patient, as<br />
virtually no collateral damage can occur.<br />
The Ma<strong>in</strong> Advantages Technical Characteristics Overview<br />
Extremely effective<br />
Fragments even the hardest s<strong>to</strong>ne material, while softer s<strong>to</strong>nes can be selectively<br />
precision treated<br />
Extremely safe<br />
The laser’s Antiperforation Mode avoids any un<strong>in</strong>tentional coagulation or<br />
perforation of soft tissue<br />
Extremely versatile - with<strong>in</strong> its discipl<strong>in</strong>e<br />
This laser can only destroy s<strong>to</strong>nes - but does this remarkably well <strong>and</strong> without the<br />
many possible complications seen, for example, with Ho:YAG lithotripters<br />
Extremely flexible<br />
The special fibre probes are optimised for use <strong>in</strong> comb<strong>in</strong>ation with flexible<br />
Ureterenoscopes (URS) <strong>and</strong> can be applied <strong>in</strong> both ureter <strong>and</strong> kidney<br />
Easy <strong>to</strong> use<br />
The device is preconfigured <strong>and</strong> ready <strong>to</strong> use immediately after be<strong>in</strong>g switched on<br />
<strong>Highly</strong> <strong>Efficient</strong> <strong>and</strong> <strong>Safe</strong> <strong>to</strong> <strong>Use</strong> <strong>in</strong><br />
<strong>Urology</strong>, <strong>Gynaecology</strong> <strong>and</strong> Gastroenterology<br />
The energy of the FREDDY 400 plus is transmitted by highly flexible fibre<br />
probes, fragment<strong>in</strong>g s<strong>to</strong>nes by a sequence of shockwaves. The extraord<strong>in</strong>ary<br />
Dual Pulse of the device (see diagram) consists of a major <strong>in</strong>frared pulse with<br />
wavelength of 1.064 nm,<br />
along with a 532 nm green energy pulse which is<br />
highly absorbed by the s<strong>to</strong>ne material.<br />
Energy<br />
Time<br />
5 μs<br />
The FREDDY 400 plus lithotripsy laser uses an optimised<br />
Dual Pulse for maximum effect at the s<strong>to</strong>ne<br />
Endoscopic View<br />
of the<br />
Fragmentation of<br />
a Bladder S<strong>to</strong>ne<br />
Dur<strong>in</strong>g treatment, a high energy plasma beam is<br />
created between the fibre tip <strong>and</strong> the s<strong>to</strong>ne, which is<br />
converted <strong>in</strong><strong>to</strong> a mechanical shockwave dur<strong>in</strong>g<br />
contact with solid s<strong>to</strong>ne material. This effect is<br />
athermal <strong>and</strong> therefore guarantees the protection of<br />
soft tissue even on direct contact with the fibre probe.<br />
Laser Type FREDDY (Frequency-Doubled Dual Pulse Nd:YAG) Laser<br />
with a wavelength of 532 <strong>and</strong> 1.064 nm<br />
Operat<strong>in</strong>g Modes & S<strong>in</strong>gle pulse with 120/160 mJ, Antiperforation Mode<br />
Pulse Energy Double pulse with 240/320 mJ, Antiperforation Mode<br />
Pulse Duration 1,2 μs @ 1.064 nm<br />
Pulse Frequency Adjustable between 1, 3, 5, 10, 15 <strong>and</strong> 20 Hz<br />
Pilot Beam red (635 nm), 3 mW, adjustable <strong>in</strong> 5 steps<br />
Beam Delivery Fibre probes of 200 <strong>and</strong> 300 μm, featur<strong>in</strong>g<br />
<strong>in</strong>tegrated quality control of the fibre conditions<br />
Electrical Requirements 230 V (6 A) / 110 V (8 A), 50 / 60 Hz, s<strong>in</strong>gle-phase<br />
Weight & Dimensions 45 kg, 38 x 88 x 60 cm (W x H x D)<br />
Technical changes reserved.