13.02.2017 Views

AC-B_leaf_en

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Modular F.R.L. Units<br />

Series <strong>AC</strong>-B<br />

How to Order<br />

Air Combination: Filter Regulator + Mist Separator<br />

Series <strong>AC</strong>20D-B to <strong>AC</strong>40D-B<br />

1<br />

2<br />

<strong>AC</strong><br />

30 D 03 DE<br />

q w e r t y<br />

B<br />

L<br />

Symbol<br />

L<br />

<strong>AC</strong>20D-B<br />

<strong>AC</strong>40D-B<br />

• Option/Semi-standard: Select one each for a to j.<br />

• Option/Attachm<strong>en</strong>t/Semi-standard symbol: Wh<strong>en</strong> more than one<br />

specification is required, indicate in alphanumeric order.<br />

Example) <strong>AC</strong>30D-F03DE1-SV-16NR-B<br />

y<br />

20<br />

Option 3)<br />

Attachm<strong>en</strong>t<br />

Semi-standard<br />

Pipe thread type<br />

a<br />

b<br />

c<br />

d<br />

e<br />

Port size<br />

Float type<br />

auto drain<br />

Symbol Description Body size<br />

20 30 40<br />

— Rc<br />

N 1)<br />

NPT<br />

F 2)<br />

G<br />

+<br />

01 1/8 — —<br />

02 1/4<br />

03 3/8 —<br />

04 1/2 — —<br />

06 3/4 — —<br />

+<br />

— Without auto drain<br />

C 4) N.C. (Normally closed) Drain port is closed wh<strong>en</strong> pressure is not applied<br />

D 5) N.O. (Normally op<strong>en</strong>) Drain port is op<strong>en</strong> wh<strong>en</strong> pressure is not applied —<br />

+<br />

gauge 6) G Round type pressure gauge (with limit indicator)<br />

— Without pressure gauge<br />

Pressure E Square embedded type pressure gauge (with limit indicator)<br />

M Round type pressure gauge (with colour zone)<br />

E1 Output: NPN output/Electrical <strong>en</strong>try: Wiring bottom <strong>en</strong>try<br />

Digital<br />

E2 Output: NPN output/Electrical <strong>en</strong>try: Wiring top <strong>en</strong>try<br />

pressure<br />

switch E3 Output: PNP output/Electrical <strong>en</strong>try: Wiring bottom <strong>en</strong>try<br />

E4 Output: PNP output/Electrical <strong>en</strong>try: Wiring top <strong>en</strong>try<br />

Pressure<br />

switch<br />

Pressure relief<br />

3 port valve<br />

+<br />

— Without attachm<strong>en</strong>t<br />

Mounting position: AW+S+AFM<br />

S 7)<br />

+<br />

— Without attachm<strong>en</strong>t<br />

V Mounting position: AW+AFM+V<br />

Mounting position: V+AWK+AFM<br />

V1 8)<br />

+<br />

Set — 0.05 to 0.85 MPa setting<br />

pressure 9) 1 0.02 to 0.2 MPa setting<br />

+<br />

f Bowl 10) 6 Nylon bowl<br />

8 Metal bowl with level gauge —<br />

— Polycarbonate bowl<br />

2 Metal bowl<br />

C With bowl guard — 11) — 11)<br />

6C Nylon bowl with bowl guard — 12) — 12)<br />

+<br />

— With drain cock<br />

Filter regulator<br />

Drain guide 1/8<br />

g Mist separator J 14)<br />

drain port 13) Drain guide 1/4 —<br />

— —<br />

W 15) Drain cock with barb fitting: For ø 6 x ø 4 nylon tube —<br />

For dim<strong>en</strong>sions and other details refer to g<strong>en</strong>eral catalogue series <strong>AC</strong>-B in our website http://www.smc.eu

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!