<strong>ATEX</strong> <strong>Pocket</strong> <strong>Guide</strong><br />

<strong>Equipment</strong> <strong>for</strong> <strong>potentially</strong><br />

<strong>explosive</strong> atmospheres<br />

For the benefit of business and people


Introduction<br />

<strong>LCIE</strong> has produced this booklet to help its<br />

clients and provide useful in<strong>for</strong>mation<br />

<strong>for</strong> manufacturers, technicians, engineers,<br />

fitters, marketing staff and end users.<br />

This handy guide has been designed <strong>for</strong> quick<br />

and easy reference. Readers will find concise<br />

answers to any queries they may have about<br />

the regulations concerning equipment <strong>for</strong><br />

<strong>potentially</strong> <strong>explosive</strong> atmospheres.<br />

To cover certain aspects in more depth, <strong>LCIE</strong> has<br />

also created a number of technical assistance<br />

modules, ASSIST PRESS, together with a<br />

series of FORM<strong>ATEX</strong> training sessions. These<br />

have been developed to provide clients with<br />

relevant and up-to-date in<strong>for</strong>mation.


Contents<br />

Contents<br />

Introduction<br />

Services provided by <strong>LCIE</strong> 2<br />

➜ Certification<br />

➜ Examination in accordance with<br />

2<br />

<strong>ATEX</strong> 94/9/EC Directive 2<br />

➜ Special tests or tests to <strong>for</strong>eign standards 2<br />

➜ Training 2<br />

➜ Audits, expert analysis, studies, assessment 3<br />

➜ Site inspection and control 3<br />

➜ Technical assistance 3<br />

➜ Fields covered 3<br />

<strong>ATEX</strong> directives 4<br />

➜ The Directive 99/92/EC 4<br />

➜ The <strong>ATEX</strong> 94/9/EC Directive 4<br />

➜ <strong>ATEX</strong> assemblies and installations 5<br />

Certification 6<br />

➜ Standards and types of protection 6<br />

➜ Meaning of marking codes 7<br />

➜ Marking temperatures, gas groups, hazardous areas<br />

➜ Degrees of protection, correlation with NEMA<br />

8<br />

standards 9<br />

<strong>ATEX</strong> 94/9/EC Directive (March 23 1994)<br />

➜ Classification of equipment by group<br />

10<br />

and category 10<br />

➜ Con<strong>for</strong>mity assessment procedures 11<br />

➜ Marking of equipment 12<br />

➜ Essential safety requirements 13<br />

➜ Other applicable directives 13<br />

<strong>LCIE</strong>’s clients 14<br />

Services offered by <strong>LCIE</strong> 15<br />

Index 16<br />

1


Services provided by <strong>LCIE</strong><br />

Services provided by <strong>LCIE</strong><br />

Certification<br />

<strong>LCIE</strong> is approved by the French Ministry of Industry to certify a<br />

wide range of electrical equipment.<br />

Examination in accordance with<br />

<strong>ATEX</strong> 94/9/EC Directive<br />

<strong>LCIE</strong> is recognized by the European Commission as a notified<br />

body (identification no. 0081) <strong>for</strong> all modules of this directive, and<br />

as such may examine equipment, protective systems, components,<br />

safety devices, controlling devices and regulating devices.<br />

<strong>LCIE</strong> is approved by French accreditation committee<br />

COFRAC - Laboratory section (Test sector) <strong>for</strong> tests on<br />

equipment <strong>for</strong> <strong>potentially</strong> <strong>explosive</strong> atmospheres<br />

(accreditation No. 1-0311).<br />

Special tests or tests to <strong>for</strong>eign standards<br />

<strong>LCIE</strong> per<strong>for</strong>ms equipment tests to international (IEC) or <strong>for</strong>eign<br />

standards.<br />

In the framework of reciprocal agreements, <strong>LCIE</strong> carries out<br />

verifications and tests according to the standards in effect<br />

in the following countries:<br />

- Canada: CSA<br />

®<br />

- U.S.A.: UL - FM<br />

- Australia: QAS - Test Safe - Simtars<br />

- Brazil: UCIEE<br />

- Argentina: BVA<br />

<strong>LCIE</strong> is also authorized to per<strong>for</strong>m tests by the Japanese<br />

Ministry of Labour (TIIS) by the SIPAI, the CQST, the PCEC<br />

(China), and by the KGS (Korea)..<br />

Training<br />

FORM<strong>ATEX</strong> training sessions are regularly run by <strong>LCIE</strong> or<br />

on company premises. The main subjects covered are:<br />

■ regulations, protection principles, hazardous areas,<br />

use and installation of equipment<br />

■ manufacture according to standardized types of protection:<br />

d, i, e, p, m, o, q, dust<br />

■ Directive 94/9/EC: principle, classification of equipment,<br />

con<strong>for</strong>mity assessment procedures, marking,<br />

specific marking.<br />

The organisation of the training sessions is run by BV.<br />

FM<br />

APPROVED<br />

2


Audits, expert analysis, studies, assessment<br />

Fields covered include standardization development,<br />

special explosion tests, numerical simulation, risk research<br />

(thermodynamics, heat science, mechanics, chemistry, etc.),<br />

quality assurance and electrostatics.<br />

Site inspection and control<br />

Inspections which are generally per<strong>for</strong>med on-site are based<br />

on the following documents:<br />

■ National regulations<br />

■ European standards EN 50014 and above<br />

■ French standard NFC 15100 (risk BE3)<br />

■ European standard EN 60079-14<br />

■ International standard IEC 60079.14<br />

Technical assistance<br />

Technical assistance provided by <strong>LCIE</strong> particularly concerns:<br />

■ identification of hazardous areas<br />

■ verification of equipment with respect to hazardous areas<br />

■ ASSIST PRESS<br />

Fields covered<br />

Under the certification procedure, <strong>LCIE</strong> examines<br />

all types of electrical and electronic equipment<br />

in the following fields:<br />

■ rotating machines<br />

■ trans<strong>for</strong>mers<br />

■ telecommunications<br />

■ detection, measurement, analysis<br />

■ control and signalling<br />

■ lighting<br />

■ electrical connections<br />

■ heating<br />

Over 5,000 certificates have been issued, to very<br />

different kinds of manufacturers.<br />

3


<strong>ATEX</strong> directives<br />

The Directive 99/92/EC concerns the end-users e.g..:<br />

Refineries, gas compressing-units.<br />

This Directive stipulates that as of June 2003 new<br />

equipment bought by the end user shall be con<strong>for</strong>ming to<br />

Directive 94/9/EC. For equipment already in place end-users<br />

have three years to assess their Ex safety level in order to<br />

determine whether it can be kept in operation as such or need<br />

to be updated or partially retested, or replaced. Be<strong>for</strong>e starting<br />

up, new equipment should have proven their compliance with<br />

the 94/9/EC Directive.<br />

It is defined that the zoning responsibility lies on the shoulder<br />

of the end-user. This means he must update the zoning of its<br />

premises every time a change affecting the zoning occurs<br />

e.g.: changing its progress, changing the organisation, of its<br />

units, revamping them or putting in operation assemblies that<br />

due to their intended use bring their own zoning.<br />

This, of course includes the new assemblies in relation<br />

to the conditions that may affect them e.g.: existing zoning,<br />

temperature condition.<br />

The <strong>ATEX</strong> 94/9/EC concerns the manufacturers e.g.:<br />

of products, of small, medium big size assembly. They have<br />

to determine whether their equipment have to be submitted<br />

to the Directive. The Directive 94/9/EC <strong>ATEX</strong> <strong>Guide</strong> <strong>for</strong> this<br />

Directive gives the way to conduct this assessment.<br />

A manufacturer is the person responsible <strong>for</strong> the design,<br />

the construction and <strong>for</strong> the progress of certification.<br />

All these tasks may be subcontracted provided the<br />

manufacturer keeps the whole responsibility. When producing<br />

product or assembly the manufacturer has the duty to<br />

determine the conditions applicable to the equipment.<br />

When it is a product made in serie, he defines the category<br />

applicable to its product. When he produces a specific<br />

product, he shall obtain the necessary in<strong>for</strong>mation<br />

(ex. existing zoning), from its customer, who generally<br />

is the end-user.<br />

<strong>ATEX</strong> directives Two <strong>ATEX</strong> directives are existing.<br />

4


<strong>ATEX</strong> directives<br />

<strong>ATEX</strong> assemblies and installations<br />

Scope of the<br />

99/92/EC Directive<br />

Scope of the Directive <strong>ATEX</strong> 94/9/EC*<br />

The manufacturer is responsible <strong>for</strong> evaluate the con<strong>for</strong>mity of his product<br />

Component Equipement Assembly Installations<br />

The end user must certify the component<br />

after inclusion of additional parts<br />

WARNING!<br />

The manufacturer may per<strong>for</strong>m<br />

the assembling at end user facilities<br />

Others Parts**<br />

EX<br />

Responsability limit between the manufacturer and the end user:<br />

(Manufacturer, assembly manufacturer, installer, …)<br />

The end user has the responsibility<br />

of the explosion risk analysis (zoning)<br />

* If the end user makes <strong>for</strong> its own use he has the same responsibilities as a manufacturer<br />

** Parts not certified (To be certified or not)<br />

5


Certification<br />

Standards and types of protection<br />

ELECTRICAL PRODUCTS<br />

Gas Dusts<br />

Cenelec IEC Type of protection symbol Cenelec/IEC Type of protection symbol<br />

- general requirements<br />

tD - protection by<br />

enclosure<br />

pD - protection by<br />

overpressurization<br />

iD - protection by<br />

intrinsic safe<br />

mD - protection by<br />

encapsulation<br />

EN/CEI 61241-0<br />

EN/CEI 61241-1<br />

- general requirements<br />

o - oil immersion<br />

CEI 60079-0<br />

CEI 60079-6<br />

EN 60079-0<br />

EN 50015<br />

EN/CEI 61241-4<br />

p - pressurized apparatus<br />

CEI 60079-2<br />

EN 50016<br />

It is essential to know which<br />

standards apply to equipment<br />

according to the type of protection<br />

chosen.<br />

EN/CEI 61241-11<br />

q - powder filling<br />

CEI 60079-5<br />

EN 50017<br />

EN/CEI 61241-18<br />

d - flameproof enclosure<br />

e - increased safety<br />

i - intrinsic safety<br />

n - concept category 3 apparatus<br />

m - encapsulation<br />

- cap lights (mines)<br />

syst. – intrinsically safe systems<br />

- electrostatic spraying equipment<br />

- equipment <strong>for</strong> zone 0<br />

EN 60079-1 CEI 60079-1<br />

EN 60079-7 CEI 60079-7<br />

EN 50020 CEI 60079-11<br />

EN 60079-15 CEI 60079-15<br />

EN 60079-18 CEI 60079-18<br />

EN 62013-1<br />

EN 60079-25 CEI 60079-25<br />

EN 50050<br />

CEI 60079-26<br />

Each type of protection corresponds<br />

to a specific concept.<br />

PRODUITS NON ELECTRIQUES<br />

CEN Type of protection symbol Concept<br />

- flow restriction enclosure<br />

- flameproof enclosure<br />

- inherent safety<br />

- constructional safety<br />

- control of ignition source<br />

- pressurization<br />

- liquid immersion<br />

general requirements<br />

fr<br />

d<br />

g<br />

c<br />

b<br />

p<br />

k<br />

EN 13463-1<br />

EN 13463-2<br />

EN 13463-3<br />

EN 13463-4<br />

EN 13463-5<br />

EN 13463-6<br />

EN 13463-7<br />

EN 13463-8<br />

CENELEC: European Committee <strong>for</strong> Electrotechnical Standardization - IEC: International Electrotechnical Commission - CEN: European Committee <strong>for</strong> Standardization<br />

6


Certification<br />

Meaning of marking codes<br />

EEx de II C T6<br />

The Community marking is of<br />

fundamental importance as it<br />

indicates the suitability of<br />

equipment <strong>for</strong> use in the hazardous<br />

areas concerned.<br />

Temperature class:<br />

maximum 85°C <strong>for</strong><br />

an ambient<br />

temperature of 40°C<br />

Gas subdivision:<br />

most critical category,<br />

including hydrogen,<br />

acetylene and carbon<br />

disulphide<br />

Used in:<br />

surface<br />

industries<br />

Types of protection<br />

used:<br />

d: flameproof<br />

enclosure<br />

e: increased safety<br />

<strong>Equipment</strong> complies<br />

with to types of protection<br />

standardized<br />

by CENELEC<br />

(European standards)<br />

Its full meaning must there<strong>for</strong>e<br />

be understood.<br />

SYST II<br />

EEx p[ia] II C T6<br />

Intrinsically safe system<br />

<strong>for</strong> surface industries.<br />

<strong>Equipment</strong> protected by pressurized enclosure<br />

and containing intrinsically safe associated apparatus<br />

7


Marking temperatures, gas groups and hazardous areas<br />

Certification<br />

Gas groups<br />

Place of use Group :<br />

CENELEC / IEC<br />

I Gaseous mines Methane<br />

II A Propane<br />

II B Ethylene<br />

II C Hydrogen<br />

Acetylene<br />

Group/class/zone<br />

Representative<br />

Canada and USA<br />

gas<br />

Mines susceptible to firedamp<br />

Surface industries D-CI I Div 1/2 II A-CI I Zone 0/1/2<br />

C-CI I Div 1/2 II B-CI I Zone 0/1/2<br />

B-CI I Div 1/2<br />

II C-CI I Zone 0/1/2<br />

A-CI I Div 1/2<br />

To ensure equipment can be safely used in hazardous areas, its gas<br />

group must be known and its temperature class must be compared<br />

with the spontaneous ignition temperature of the gas mixtures<br />

concerned.<br />

Classification of hazardous locations<br />

Marking temperatures<br />

Occasional<br />

presence<br />

(abnormal operation<br />

conditions)<br />

Intermittent<br />

presence<br />

(normal operation<br />

conditions)<br />

Continuous<br />

presence<br />

Explosive<br />

atmosphere<br />

Zone 2 (gas)<br />

Zone 22 (dust)<br />

Zone 1 (gas)<br />

Zone 21 (dust)<br />

IEC,Europe, France Zone 0 (gas)<br />

Zone 20 (dust)<br />

Temperature class<br />

(CENELEC / IEC) Group II T1 T2 T3 T4 T5 T6<br />

Maximum surface<br />

temperature 450°C 300°C 200°C 135°C 100°C 85°C<br />

The maximum surface temperature of equipment must always be lower than<br />

the ignition temperature of the gas present in the hazardous area.<br />

Cl I Div 2 / Cl I Zone 2 (gas)<br />

Cl II Div 2 (dust)<br />

Cl III Div 2 (fibres)<br />

Cl I Div 1 / Cl I Zone 1 (gas)<br />

Cl II Div 1 (dust)<br />

Cl III Div 1 (fibres)<br />

Cl I Div 1 / Cl I Zone 0 (gas)<br />

Cl II Div 1 (dust)<br />

Cl III Div 1 (fibres)<br />

Canada (CEC) 1<br />

USA (NEC) 2<br />

(1) CEC : Canadien Electricity Code / (2) NEC : National Electrical Code<br />

8


Certification<br />

Degrees of protection<br />

Enclosure protection<br />

indices IEC 60529<br />

Index IP Index Second figure indicates protection<br />

against water penetration<br />

First figure indicates protection<br />

against dangerous access and<br />

solid <strong>for</strong>eign objects<br />

Full enclosure protection is often required, either in the standards concerning<br />

<strong>potentially</strong> <strong>explosive</strong> atmospheres or <strong>for</strong> other specific needs.<br />

Non-protected<br />

Vertically falling water drops<br />

0<br />

1<br />

2<br />

0<br />

1<br />

2<br />

Vertically falling water drops when<br />

enclosure tilted up to 15 °<br />

Spraying water up to 60 ° from vertical<br />

3<br />

3<br />

Splashing water from any direction<br />

4<br />

4<br />

5 4<br />

Jets of water from any direction<br />

5<br />

5<br />

Powerful jets of water from any direction<br />

6<br />

6<br />

Non-protected<br />

Back of a hand<br />

solid objects 50 mm Ø or more<br />

Finger<br />

solid objects 12.5 mm Ø or more<br />

Tool<br />

solid objects 2.5 mm Ø or more<br />

Wire 1 mm<br />

solid objects 1 mm Ø or more<br />

Wire 1 mm<br />

Dust-protected<br />

Wire 1 mm<br />

Dust-tight<br />

Immersion<br />

Continuous immersion<br />

7<br />

8<br />

Correlation between IP (IEC)<br />

and NEMA1 250 standards<br />

IP 10<br />

NEMA 1<br />

IP 11<br />

NEMA 2<br />

IP 14<br />

NEMA 3R<br />

IP 52<br />

NEMA 5-12-12K<br />

IP 54<br />

NEMA 3-3S-13<br />

IP 56<br />

NEMA 4-4X<br />

IP 67<br />

NEMA 6-6P<br />

(1) National Electrical Manufacturers Association (US)<br />

Note: enclosures to NEMA standards 7 to 10 concern equipment<br />

<strong>for</strong> hazardous areas.<br />

9


For the benefit of business and people<br />

33, av du Général Leclerc - 92260 Fontenay-aux-Roses - France<br />

Tel: +33 1 40 95 60 60 - Fax: +33 1 40 95 86 56<br />

contact@lcie.fr - www.lcie.com<br />

Design and production: Inventive — Photograph: Le Square des Photographes - © <strong>LCIE</strong> - All rights reserved - 10/2004


Classification<br />

<strong>ATEX</strong> 94/9/EC Directive<br />

<strong>Equipment</strong> is classified by group and category according to its intended use<br />

Comparison with<br />

present practice and IEC<br />

Level of<br />

Fault<br />

protection<br />

protection<br />

Very high level 2 types of protection or<br />

2 independent faults<br />

High level<br />

1 type of protection<br />

Normal operation<br />

Very high level 2 types of protection<br />

or 2 independent faults<br />

High level 1 type of protection<br />

Habitual frequent malfunction<br />

Normal Required level<br />

of protection<br />

Inflammable<br />

substances<br />

Methane,<br />

dust<br />

Methane,<br />

dust<br />

Gas, vapours,<br />

mist, dust<br />

Gas, vapours,<br />

mist, dust<br />

Gas, vapours,<br />

mist, dust<br />

Category of<br />

equipment<br />

Group I<br />

Group I<br />

M1<br />

M2<br />

1<br />

2<br />

3<br />

Apparatus<br />

group I<br />

(mines)<br />

<strong>LCIE</strong> is notified <strong>for</strong> all modules<br />

of this new approach Directive<br />

(annexes III to IX).<br />

(<strong>LCIE</strong> identification no. 0081).<br />

Group II<br />

Z 0 (gas) / Z20 (dust)<br />

Group II<br />

Z 1 (gas) / Z21 (dust)<br />

Group II<br />

Z 2 (gas) / Z22 (dust)<br />

Apparatus<br />

group II<br />

(surface)<br />

10


(March 23 1994)<br />

Con<strong>for</strong>mity assessment procedures<br />

Procedures <strong>for</strong> assessment of con<strong>for</strong>mity (various possible cases)<br />

Inspection of production<br />

quality insurance by NB 1 Annex IV<br />

and<br />

or<br />

EC type examination<br />

by NB 1 Annex III<br />

Product sample<br />

inspection by NB 1 Annex V<br />

or<br />

I / II<br />

M1 (mines)<br />

1 (surface)<br />

EC inspection of<br />

each unit by NB 1<br />

Annex IX<br />

<strong>LCIE</strong> is competent to per<strong>for</strong>m EC type<br />

examinations and to assess<br />

production and product quality<br />

assurance systems.<br />

Inspection of product<br />

quality insurance by NB 1 Annex VII<br />

or<br />

and<br />

Con<strong>for</strong>mity to type<br />

Tests under responsibility of NB 1<br />

Annex VI<br />

Internal production inspection<br />

File sent to NB 1 Annex VIII<br />

EC type examination<br />

by NB 1 Annex III<br />

Electrical equipment or<br />

internal combustion engines<br />

or<br />

I / II<br />

M2 (mines)<br />

2 (surface)<br />

Non-electrical equipment<br />

EC inspection of<br />

each unit by NB 1<br />

Annex IX<br />

Internal production inspection<br />

Annex VIII<br />

II<br />

3 (surface)<br />

For the latter, notified bodies use<br />

identical specific reference systems<br />

like EN 13980.<br />

These reference standards are based<br />

on ISO standards: ISO 9000(1994) or<br />

ISO 9001(2000).<br />

EC inspection of<br />

each unit by NB 1<br />

Annex IX<br />

or<br />

Marking<br />

EC declaration of con<strong>for</strong>mity<br />

by manufacturer or representative<br />

Con<strong>for</strong>mity assessment procedure<br />

Involvement of (NB) 1<br />

1 NB: notified body<br />

11


Marking of equipment<br />

II 2 G and D<br />

Example<br />

…<br />

<strong>ATEX</strong> 94/9/EC Directive<br />

Gas Dust<br />

<strong>Equipment</strong> category:<br />

present zone 1<br />

<strong>Equipment</strong> group:<br />

<strong>for</strong> surface<br />

Use of equipment in <strong>potentially</strong><br />

<strong>explosive</strong> atmospheres<br />

Identification number of<br />

notified body (where appropriate)<br />

(<strong>LCIE</strong>: 0081)<br />

In addition to the required<br />

marking, equipment<br />

must carry specific marking<br />

<strong>for</strong> <strong>potentially</strong> <strong>explosive</strong><br />

atmospheres.<br />

marking<br />

This marking is to be supplemented by all relevant in<strong>for</strong>mation, in particular by specific marking <strong>for</strong> types of protection, e.g.: EEx d II C T6<br />

12


(March 23 1994)<br />

These cover a wide field, fully detailed in annex II<br />

of the new Directive.<br />

➜ Integrated safety principle<br />

➜ Specific conditions of inspection and maintenance<br />

➜ Environmental conditions<br />

➜ Marking<br />

➜ Instructions <strong>for</strong> use<br />

➜ Choice of materials<br />

➜ Design and manufacture<br />

➜ Potential ignition sources<br />

■ sparks<br />

■ flames<br />

■ electric arcs<br />

■ high surface temperatures<br />

■ acoustic energy<br />

■ radiation: optical, electromagnetic or other sources<br />

➜ Risks caused by software<br />

➜ Explosive atmospheres caused by the presence of gas,<br />

vapours and mist<br />

➜ Explosive atmospheres caused by the presence of air-dust<br />

mixtures.<br />

<strong>Equipment</strong> covered by the Directive 94/9/EC must also<br />

meet the requirements of the other relevant Directives:<br />

➜ Electromagnetic Compatibility Directive (EMC)<br />

89/336/EEC, modified by 92/31/EEC and 93/68/EEC<br />

mandatory application as from January 1, 1996.<br />

<strong>LCIE</strong> is a competent and notified body <strong>for</strong> this directive.<br />

➜ Machinery Directive<br />

98/37/EC, 89/392/EEC, modified by 91/368/EEC,<br />

93/44/EEC and 93/68/EEC<br />

application as from January 1, 1995.<br />

<strong>LCIE</strong> is a notified body (B1-B2 safety components)<br />

Other Directives must also be taken into account in certain<br />

cases, such as those concerning simple pressure vessels<br />

(87/404/EEC) and gas appliances (90/396/EEC), along with<br />

others presently being drawn up. It should be noted that the<br />

Low Voltage Directive (73/23/EEC, modified by Directive<br />

93/68/EEC) explicitly excludes equipment <strong>for</strong> <strong>potentially</strong><br />

<strong>explosive</strong> atmospheres. Manufacturers must nevertheless<br />

guarantee that their equipment fully complies with current safety<br />

regulations. The rules defined in the Low Voltage Directive may<br />

serve as a guideline.<br />

Essential safety requirements Essential safety requirements:<br />

13


<strong>LCIE</strong> provides certification<br />

and assessment <strong>for</strong> companies<br />

all around the world<br />

We certify and evaluate<br />

... Belgium - Canada - Denmark - European Union - Finland<br />

France - Germany - Hungary - Indonesia - Italy - Japan<br />

The Netherlands - Norway - Russia - Singapore - Sweden<br />

Switzerland - United Kingdom - USA …<br />

… 3M France - ABB - ABB Process Analytics - Air Liquide - Alfa Laval<br />

Alstom/ACEC - Ametek - A puissance 3 - ASCO - Atlas Copco - Atochem<br />

A.T.X. - Auxitrol - Balston - Barksdale - Bartec - Bovar - BP - Butagaz<br />

Capri Codec - CDF Chimie - CEA - Cégélec - CE Nancy - Cetal - Ciba Geigy<br />

Clemessy - Cray Valley - Crouzet - DCAN - DTS - Du Pont de Nemours - Ecans<br />

Eckardt - EI - ELF - Elsag Bailey - Endress & Hauser - Enraf - Entrelec<br />

Esso - Etirex - Exxon - Fillon Pichon - FIR - Fisher Controls - Fluidystème<br />

Foster Wheeler - Foxboro - Gaz de France - GEC Alsthom - Georgin - Gorse<br />

GTIE - Hartmann & Braun - Haver & Boecker - Hewlett Packard - Hoechst<br />

Honeywell - Icare - ICI - IFP - Intertechnique - Jeumont Schneider<br />

Joucomatic - KEM - Kestner - Kienzle - Kodak Pathé - Krohne - KSB - Landia<br />

Leroy Somer - Le Las - Litwin - L’Oréal - Lorilleux - Mc Dermott<br />

Mannesman - Maréchal - Masoneilan - Matsushima - Merlin Gérin - Mettler<br />

Mobil Oil - Montabert - Motorola - Naphtachimie - Nippon Steel - Nuovo Pignone<br />

Otic Fisher et Porter - Parker - Peperl und Fuchs - Petrel - Philips - Pompes<br />

Mouvex - Primagaz - Procon - Raychem - Rhône Poulenc - Rolls Royce<br />

Rosemount Analytical - Rotork - Roussel Uclaf - Saab Marine - Sammode<br />

Sanofi - Saunier Duval - SBM - Schulz und Heinisch - Sereg Schlumberger<br />

Serete - SFIM - Shell - Sicme Motori - Siemens - SNPE - Sogelerg<br />

Solar Turbines - Solvay - Sony - Souriau - SPIE Trindel - Stahl - Technip<br />

Technor - Télémécanique - Telxon - Thermodyn - Thermon France - Tokheim<br />

Total - Tuboméca - VeederRoot - Whessoe Varec - Woodward Governor<br />

Yaskawa…<br />

Industry trusts these companies...<br />

They have all trusted <strong>LCIE</strong>...<br />

Join them in full confidence...<br />

14


Services offered by <strong>LCIE</strong><br />

Services offered by <strong>LCIE</strong><br />

Testing according to <strong>for</strong>eign standards<br />

■ CSA, UL, FM, BS, IEC, MIL, others.<br />

Certification / EC type examination<br />

■ <strong>Equipment</strong>, assemblies, systems, components.<br />

Audits, surveys, studies, assessments, training<br />

■ Quality insurance, standardization development,<br />

risk analysis, zoning, site inspection, electrostatics,<br />

special explosion tests. FORM<strong>ATEX</strong> sessions,<br />

at <strong>LCIE</strong> or on site.<br />

Technical assistance<br />

■ Certification procedures.<br />

■ Identification of standards.<br />

Further in<strong>for</strong>mation:<br />

Customer Service Department<br />

<strong>ATEX</strong> Contact:<br />

Tel : +33 1 40 95 63 11<br />

Fax : +33 1 40 95 89 37<br />

www.lcie.com<br />

15


Index<br />

Index<br />

Approved body 2<br />

ASSIST PRESS 3<br />

<strong>ATEX</strong> 100A directive 10<br />

Canada, USA, Japan, Australia, Brazil, Argentina 2<br />

Categories of equipment 10<br />

EC declaration of con<strong>for</strong>mity 11<br />

EC type examination 11<br />

marking 2, 12<br />

Certification 2<br />

Classification under New Directive 94/9/EC 10<br />

Con<strong>for</strong>mity assessment procedures 11<br />

Correlation between IEC (IP) and NEMA standards 9<br />

Directive 94/9/EC (<strong>ATEX</strong> 100A) 10-13<br />

Electromagnetic compatibility directive (EMC) 13<br />

Enclosure protection degrees (indices) 9<br />

<strong>Equipment</strong> <strong>for</strong> hazardous areas 3<br />

<strong>Equipment</strong> groups 10<br />

Essential safety requirements 13<br />

Gas groups 8<br />

Hazardous areas 3, 7, 8<br />

IP degrees (IEC 60529) 9<br />

ISO 9000(1994) or ISO 9001(2000) standards 11<br />

<strong>LCIE</strong> - electrostatics, quality assurance, special tests 2<br />

<strong>LCIE</strong> - fields of activity 3<br />

<strong>LCIE</strong> - references 14<br />

<strong>LCIE</strong> - services provided 2, 15<br />

<strong>LCIE</strong> - site inspection 3<br />

<strong>LCIE</strong> - expert analysis, studies, assessment 3<br />

<strong>LCIE</strong> - technical assistance 3, 15<br />

16


<strong>LCIE</strong> - tests to <strong>for</strong>eign standards 2<br />

<strong>LCIE</strong> - training 2<br />

Low Voltage Directive 13<br />

Machinery Directive 13<br />

Marking codes 7<br />

Marking temperatures 8<br />

Modules (annexes to Directive 94/9/EC) 2, 10<br />

NEMA standards (correlation with IP indices) 9<br />

Notified body 2, 10, 11, 13<br />

Protection indices (IP) 9<br />

Quality assurance (production and product) 11<br />

Reciprocal agreements with CSA, TIIS and FM 2<br />

Rotating machines, trans<strong>for</strong>mers 3<br />

Special tests 2<br />

Standards and types of protection 6<br />

Zoning 4, 5<br />

17


Notes<br />

Notes<br />

18


Notes<br />

Notes<br />

19


Notes<br />

Notes<br />

20


This booklet has been prepared with care<br />

and the in<strong>for</strong>mation provided in it is given<br />

in good faith.<br />

<strong>LCIE</strong> cannot be held responsible <strong>for</strong> any<br />

errors or omissions it may contain.<br />

The use or interpretation of the in<strong>for</strong>mation<br />

contained in this booklet is the sole<br />

responsibility of the user.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!